• 제목/요약/키워드: Diagnostic specificity

검색결과 962건 처리시간 0.02초

Diagnostic value of eosinopenia and neutrophil to lymphocyte ratio on early onset neonatal sepsis

  • Wilar, Rocky
    • Clinical and Experimental Pediatrics
    • /
    • 제62권6호
    • /
    • pp.217-223
    • /
    • 2019
  • Purpose: To determine the diagnostic value of eosinopenia and the neutrophil-to-lymphocyte ratio (NLR) in the diagnosis of early onset neonatal sepsis (EONS). Methods: This cross-sectional study was conducted in the Neonatology Ward of R.D. Kandou General Hospital Manado between July and October 2017. Samples were obtained from all neonates meeting the inclusion criteria for EONS. Data were encoded using logistic regression analysis, the point-biserial correlation coefficient, chi-square test, and receiver operating characteristic curve analysis, with a P value <0.05 considered significant. Results: Of 120 neonates who met the inclusion criteria, 73 (60.8%) were males and 47 (39.2%) were females. Ninety (75%) were included in the sepsis group and 30 (25%) in the nonsepsis group. The mean eosinophil count in EONS and non-EONS groups was $169.8{\pm}197.1cells/mm^3$ and $405.7{\pm}288.9cells/mm^3$, respectively, with statistically significant difference (P<0.001). The diagnostic value of eosinopenia in the EONS group (cutoff point: $140cells/mm^3$) showed 60.0% sensitivity and 90.0% specificity. The mean NLR in EONS and non-EONS groups was $2.82{\pm}2.29$ and $0.82{\pm}0.32$, respectively, with statistically significant difference (P<0.001). The diagnostic value of NLR in the EONS group (cutoff point, 1.24) showed 83.3% sensitivity and 93.3% specificity. Conclusion: Eosinopenia has high specificity as a diagnostic marker for EONS and an increased NLR has high sensitivity and specificity as a diagnostic marker for EONS.

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • 제29권6호
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

Diagnostic performance of enzyme-linked immnosorbent assays for diagnosing paratuberculosis in cattle: a meta-analysis

  • Pak, Son-Il
    • 대한수의학회지
    • /
    • 제44권4호
    • /
    • pp.669-676
    • /
    • 2004
  • To evaluate the diagnostic accuracy of two commercial ELISA tests (Allied- and CSL-ELISA) for the diagnosis of Mycobacterium paratuberculosis in cattle, Meta-analysis using English language papers published during 1990-2001 was performed. Diagnostic odds ratios (DOR) were analyzed using regression analysis together with summary receiver operating characteristic (ROC) curves. The difference in diagnostic performance between the two ELISA systems was evaluated by using linear regression. Publication bias was assessed by funnel plot and linear regression. The pooled sensitivity and specificity were 44% (95% CI, 38 to 51) and 98% (95% CI, 96 to 99) for the random-effect model. The DOR between studies was heterogeneous. The area under the fitted ROC curve (AUC) was 0.72 for the unweighted and 0.77 for the weighted model. Maximum joint sensitivity and specificity for the unweighted and weighted model from their summary ROC curve were 70% and 75%, respectively. Based on the fitted model, at a specificity of 95%, sensitivity was estimated to be 52% for the unweighted and 57% for the weighted model. From the final multivariable model study characteristic, the country was the only significant variable with an explained component variance of 13.3%. There were no significant differences in discriminatory power, sensitivity, and specificity between the two ELISA tests. The overall diagnostic accuracy of two commercial ELISA tests was moderate, as judged by the AUC, maximum joint sensitivity and specificity, and estimates from the fitted model and clinical usefulness of the tests for screening program is limited because of low sensitivity and heterogeneous of DOR. It is, therefore, recommended to use ELISA tests as a parallel testing with other diagnostic tests together to increase test sensitivity in the screening program.

상악동의 점막비후에 대한 WATERS방사선사진과 파노라마방사선사진 및 전산화단층사진의 진단능 비교 (Comparison of Waters′ radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening)

  • 현영민;이삼선;최순철
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.261-269
    • /
    • 1998
  • With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation point was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed : 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05), 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05).

  • PDF

코로나19 신속진단검사는 얼마나 정확한가? (How accurate are rapid diagnostic tests for covid-19?)

  • 여인권
    • 응용통계연구
    • /
    • 제35권3호
    • /
    • pp.435-443
    • /
    • 2022
  • 이 논문에서는 질병관리청에서 제공한 코로나 진단검사 관련 자료를 이용하여 신속진단키트의 민감도 및 특이도에 따른 확진 비율과 신속검사에서 음성이 나왔을 때 실제로는 확진이었을 확률에 대해 알아본다. 또한 양성 반응 중 실제 확진의 확률을 알 때 민감도와 특이도 간의 관계를 유도하고 이를 통해 질병관리청의 자료에 따른 신속진단키트의 실제 민감도가 얼마나 되는지 알아 본다.

Use of Likelihood Ratios in Evidence-based Clinical Decision Making

  • Kim, Eu-Tteum;Pak, Son-Il
    • 한국임상수의학회지
    • /
    • 제25권3호
    • /
    • pp.146-151
    • /
    • 2008
  • During the clinical decision making practitioners are often faced with performing diagnostic tests to solve the presenting problems seen in the patients. The diagnostic utility of a test has traditionally been described by technical terms such as sensitivity, specificity, and positive (PPV) and negative predictive value (NPV). Although well known, clinicians are frequently unclear about the concept and application of these terms in everyday evidence-based clinical decision making. Sensitivity and specificity, which are intrinsic properties of diagnostic tests, summarizes the characteristics of the test over a population. The PPV and NPV are greatly dependent on the population prevalence of disease, and thus they do not transferable to different patients or clinical settings. Besides, considering the fact that clinicians more often interested in knowing the extent to which a test result could confirm or exclude of a condition under consideration (posttest probability), these measures do not provide answers on this question. The likelihood ratios (LR) using the information contained in sensitivity and specificity are becoming increasingly popular for reporting the usefulness of diagnostic tests because this term provide an indication of posttest probability as a function of the pretest probability. In this article, clinical applications of LR are illustrated with some practical examples. Discussion is also included of the inherent limitations regarding diagnostic test characteristics.

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.

Reliability of Stool Antigen Tests: Investigation of the Diagnostic Value of a New Immunochromatographic Helicobacter pylori Approach in Dyspeptic Patients

  • Korkmaz, Huseyin;Findik, Duygu;Ugurluoglu, Ceyha;Terzi, Yuksel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권2호
    • /
    • pp.657-660
    • /
    • 2015
  • Background: A diagnosis of H. pylori infection can be made by invasive or non-invasive methods. Several noninvasive diagnostic tests based on the detection of H. pylori stool antigen (HpSA) have been developed. The Genx H. pylori stool antigen card test is a new rapid, non-invasive test that is based on monoclonal immunochromatographic assay. The aim of this study was to determine its sensitivity, specificity, and diagnostic accuracy for diagnosing H. pylori infection in adult patients. Materials and Methods: A total of 162 patients were included in the study. A gastric biopsy was collected for histopathology and rapid urease testing. Stool specimens for HpSA testing were also collected. Patients were considered H. pylori positive if two invasive tests (histological and rapid urease tests) were positive. Results: Using the reference test, 50.6% of the samples were positive for H. pylori infection. The Genx H. pylori antigen test was positive in 19.7% of patients. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the Genx H. pylori antigen test were 51.6%, 96.0%, 88.8%, 76.1%, and 79.0%, respectively. Conclusions: The Genx H. pylori stool antigen card test is a new non-invasive method that is fast and simple to perform but provides less reliable results.

천장관절 기능부전에 대한 검사방법들의 진단적 가치 : 정형도수치료적 평가를 중심으로 (Diagnostic Value on the Orthopaedic Tests for Sacroiliac Joint Dysfunction)

  • 윤홍일;심현보
    • 대한정형도수물리치료학회지
    • /
    • 제16권1호
    • /
    • pp.64-76
    • /
    • 2010
  • The sacroiliac joint is difficult to appropriately examine and treat because it is extremely complex and also is difficult to distinguish dysfunctions from those of the spine and hip which are highly intergrated functionally. In addition generally traditional x-rays and CT scans also are not beneficial in detecting sacroiliac joint dysfunction. The manipulative physiotherapist should seek to establish a series of relevant finding that build into a case implicating the sacroiliac joint. When deciding to use these diagnostic tests, the examiner must determine if the test will give reliable and useful information that will help in the diagnosis and subsequent treatment. To be useful diagnostic tests must give reliable data and be valid and the most useful methods of determining whether a test is a good test for pathology under consideration are sensitivity and specificity. In the ideal world, one would want a test that has both high sensitivity and high specificity. The purpose of this review is to ascertain diagnostic value on the tests for sacroiliac joint dysfunction by literature.

  • PDF

Comparison of 99mTc-DMSA Renal Scan and Power Doppler Ultrasonography for the Detection of Acute Pyelonephritis and Vesicoureteral Reflux

  • Bae, Hee Jung;Park, Yong-Hoon;Cho, Jae Ho;Jang, Kyung Mi
    • Childhood Kidney Diseases
    • /
    • 제22권2호
    • /
    • pp.47-51
    • /
    • 2018
  • Purpose: Urinary tract infection (UTI) is one of the common infectious diseases in children. Several imaging modalities can be used to confirm the presence of acute pyelonephritis (APN). Among them the 99mTcdimercaptosuccinic acid renal scan (DMSA scan) is used as a gold standard for diagnosis. Ultrasonography technology is evolving. Therefore, in this study, we investigated the sensitivity and specificity of Power Doppler ultrasonography (PDU) compared to the results from the previous study. Methods: There were 260 patients included in this study, aged between 1 and 12 months old. The patients were admitted to the Yeungnam University Medical Center between January 2008 and December 2015. All patients underwent both DMSA scan and PDU within 5days of admission. Voiding cystourethrography (VCUG) was performed in 195 patients with abnormal DMSA scan or PDU. Results: The diagnostic sensitivity of APN using PDU was 45.5% and specificity was 85.5% in 260 patients following detection of a defect on DMSA scan that was defined as APN. The diagnostic sensitivity and specificity of PDU for VUR were 65.5 % and 60.1%, respectively. The diagnostic sensitivity and specificity of DMSA scan for VUR were 95.7% and 14.1%, respectively. Conclusion: PDU has a high specificity but low sensitivity, so there are limitations in using it to replace a DMSA scan for the diagnosis of APN in children. DMSA scan and PDU have different sensitivity and specificity in diagnosis of VUR, respectively. Therefore, we suggest that the sensitivity and specificity of each test can be helpful in diagnosing APN and VUR when used in conjunction.