• Title/Summary/Keyword: Diagnostic ratio

Search Result 812, Processing Time 0.026 seconds

Study on the Application of Oriental Medical Evaluation to Dementia (치매 한의진단 평가도구 적용 연구)

  • Kim, Ka-Na;Bae, Hyunsu;Hwang, Wei-Wan;Cho, Seung-Hun
    • Journal of Oriental Neuropsychiatry
    • /
    • v.25 no.4
    • /
    • pp.383-388
    • /
    • 2014
  • Objectives: Patients with dementia are increasing in Korea. So the importance of accurate diagnosis and treatment of dementia is growing. In this paper, we evaluated the result of employing the Korean medical diagnostic pattern as a tool in clinics. Methods: Patients diagnosed with Alzheimer's disease were evaluated using the Korean medical diagnostic pattern tool. Results: The number of patients with liver-kidney yin deficiency pattern/syndrome was 35. Analyzing the ratio difference between the 'liver-kidney yin deficiency' group and the 'not liver-kidney yin deficiency' group revealed that the ratio of the responses to the fourth question was less than zero. The ratio of the responses to the fifth, seventh, and eight questions were all less than 10%. The ratio of the responses to the first and second questions were greater than 30%. Conclusions: Of the six diagnostic patterns, liver-kidney yin deficiency was the greatest in the study subjects. The fourth question in the liver-kidney yin deficiency tool tests for the lack of appropriateness whereas the fifth, seventh, and eight questions test for lack of discrimination. Applying more weight to the first and second questions was an excellent choice to increase the discrimination.

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue;Takeshi Nakaura;Yasunori Nagayama;Hiroyuki Uetani;Osamu Ikeda;Yasuyuki Yamashita
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.951-958
    • /
    • 2021
  • Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.

Non-Invasive Diagnostic Singature Extraction for Motor-Operated Valves (모터 구동 밸브의 비침투 진단 신호 추출에 관한 연구)

  • ;Richard H. Lyon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.360-364
    • /
    • 1994
  • This paper is concerned with extracting the diagnostic signature for motor-operated valves (MOV's) noninvasively. A torque estimator is developed and tested to obtain electical torque of the induction motors which are attached to the MOV's. Inverse filter is used to recover the gear meshing forces from the measured actuator housing vibration, which contain the gear rotation information. Frequency demodulation techniques are performed and an adaptive linear bandpass filter is implemented to improve signal-to-noise ratio. Finally, stand-alone valve experiments are carried out to validate the signature extraction scheme.

  • PDF

Diagnostic Paper Chip for Reliable Quantitative Detection of Albumin using Retention Factor (체류 인자를 이용한, 알부민의 정량 분석용 종이 칩)

  • Jeong, Seong-Geun;Lee, Sang-Ho;Lee, Chang-Soo
    • KSBB Journal
    • /
    • v.28 no.4
    • /
    • pp.254-259
    • /
    • 2013
  • Herein we present a diagnostic paper chip that can quantitatively detect albumin without external electronic reader and dispensing apparatus. We fabricated a diagnostic paper chip device by printing wax barrier on the paper and wicking it with citrate buffer and tetrabromophenol blue to detect albumin in sample solution. The paper chip is so simple that we dropped a sample solution at sample pad and measure the ratio of two travel distances of the sample solvent and albumin under the name of retention factor. Our result confirmed that the retention factor was constant in the samples with same concentration of albumin and useful determinant for the measurement of albumin concentration. The paper chip is affordable and equipment-free, and close to ideal point-of-care test in accordance with the assured criteria, outlined by the World Health Organization. We assume that this diagnostic paper chip will expand the concept of colorimetric determination and provide a inexpensive diagnostic method to aging society and developing country.

Exploration and Development of SERVQUAL

  • Kim, Yong-Pil;Kim, Kye-Wan;Yun, Deok-Gyun
    • International Journal of Quality Innovation
    • /
    • v.4 no.1
    • /
    • pp.116-130
    • /
    • 2003
  • The gap-based SERVQUAL model is a popular service quality determinant due to its superior diagnostic capacity over alternative explanatory frameworks. However, some researchers criticize the performance of the SERVQUAL model and propose alternative service Quality measurement constructs. Nevertheless, it is argued that the superior diagnostic capacity of SERVQUAL is its key strength; and that any criticism made of it when making comparison with alternative models does not reflect the differing nature of scales of statistical analysis. Arguably, the only limitation of a gap-based model is misinterpretation of customers' evaluation and perception of a service. In this research, the gap score is transformed into a ratio score. Also, empirical tests and implications are presented to support this alternative contribution to the body of knowledge.

Traumatic Diaphragmatic Injuries (Report of 22 Cases) (외상성 횡경막 손상 -22례 보고-)

  • 두홍서
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.364-370
    • /
    • 1989
  • 22 Cases of traumatic diaphragmatic injuries treated at the Department of Thoracic and Cardiovascular Surgery in Chon-Buk National University Hospital from Jan. 1979 to Oct. 1988 were reviewed in this study. Of the 22 cases, 18 were male and 3 were female, a ratio of 4.5:1. This ratio revealed high incidence in male patient. The age distribution ranged from 2 to 60 years and mean age was 31 years. The modes of injury were as follows: 11 stab wound, 5 traffic accident, 2 fall down, 2 fighting injury, 1 compression wound by sand bag, and 1 slip down injury. Useful diagnostic tools were chest X-ray with or without radiopaque dye swallowing, which was the most commonly diagnostic, UGI series, and thoracoscope. Operations were performed in 22 cases, and 18 cases were through thoracotomy. The herniated organs through the ruptured diaphragm were stomach, omentum, liver, spleen, colon, and small bowel. There were associated injuries, and the most commonly associated was rib fracture. There was no postoperative death.

  • PDF

Regression Diagnostic Using Residual Plots

  • Oh, Kwang-Sik
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.2
    • /
    • pp.311-317
    • /
    • 2001
  • It is necessary to check the linearity of selected covariates in regression diagnostics. There are various graphical methods using residual plots such as partial residual plots, augmented partial residual plots and combining conditional expectation and residual plots. In this paper, we propose the modified pseudolikelihood ratio test statistics based on these residual plots to test linearity of selected covariate. These test statistics which measure the distance between the nonparametric and parametric models are derived as a ratio of quadratic forms. The approximate distribution of these statistics is calculated numerically by using three moments. The power comparison of these statistics is given.

  • PDF

Influence Measures for the Likelihood Ratio Test on Independence of Two Random Vectors

  • Jung, Kang-Mo
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.13-16
    • /
    • 2001
  • We compare methods for detecting influential observations that have a large influence on the likelihood ratio test statistics that the two sets of variables are uncorrelated with one another. For this purpose we derive results of the deletion diagnostic, the influence function, the standardized influence matrix and the local influence. An illustrative example is given.

  • PDF

Diagnostics for Heteroscedasticity in Mixed Linear Models

  • Ahn, Chul-Hwan
    • Journal of the Korean Statistical Society
    • /
    • v.19 no.2
    • /
    • pp.171-175
    • /
    • 1990
  • A diagnostic test for detecting nonconstant variance in mixed linear models based on the score statistic is derived through the technique of model expansion, and compared to the log likelihood ratio test.

  • PDF

Exposure to Cerium Oxide Nanoparticles Is Associated With Activation of Mitogen-activated Protein Kinases Signaling and Apoptosis in Rat Lungs

  • Rice, Kevin M.;Nalabotu, Siva K.;Manne, Nandini D.P.K.;Kolli, Madhukar B.;Nandyala, Geeta;Arvapalli, Ravikumar;Ma, Jane Y.;Blough, Eric R.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.3
    • /
    • pp.132-141
    • /
    • 2015
  • Objectives: With recent advances in nanoparticle manufacturing and applications, potential exposure to nanoparticles in various settings is becoming increasing likely. No investigation has yet been performed to assess whether respiratory tract exposure to cerium oxide ($CeO_2$) nanoparticles is associated with alterations in protein signaling, inflammation, and apoptosis in rat lungs. Methods: Specific-pathogen-free male Sprague-Dawley rats were instilled with either vehicle (saline) or $CeO_2$ nanoparticles at a dosage of 7.0 mg/kg and euthanized 1, 3, 14, 28, 56, or 90 days after exposure. Lung tissues were collected and evaluated for the expression of proteins associated with inflammation and cellular apoptosis. Results: No change in lung weight was detected over the course of the study; however, cerium accumulation in the lungs, gross histological changes, an increased Bax to Bcl-2 ratio, elevated cleaved caspase-3 protein levels, increased phosphorylation of p38 MAPK, and diminished phosphorylation of ERK-1/2-MAPK were detected after $CeO_2$ instillation (p<0.05). Conclusions: Taken together, these data suggest that high-dose respiratory exposure to $CeO_2$ nanoparticles is associated with lung inflammation, the activation of signaling protein kinases, and cellular apoptosis, which may be indicative of a long-term localized inflammatory response.