• Title/Summary/Keyword: Diagnostic monitor

Search Result 151, Processing Time 0.026 seconds

Implementation of on Expert System to Supervise GIS Arrester Facilities (GIS 피뢰설비 관리를 위한 전문가 시스템 구현)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon;Moon, Seung-Bo;Kwon, Jang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.75-81
    • /
    • 2007
  • This paper dealt with the design and implementation of an expert system to monitor and diagnose the lightning arresters in GIS substations. The expert system consists of a data acquisition module(DAM) based on microprocessor and diagnostic algorithms. The DAM measures and analyzes several parameters necessary for the arrester diagnosis such as system voltages, leakage current components, and temperatures. Also, it includes an intelligent surge counter which can record the date and tin, the polarity, and the amplitude of surge currents. All the data acquired is transmitted to a remote computer by a low rate wireless network specified in IEEE 802.15.4 to avoid electromagnetic intereference under high voltage and large current environments. The decision-making for the arrester diagnosis completes with a Java Expert System Shell(JESS) which is composed of a knowledge base, an inference engine and a graphic user interface(GUI).

Study on Vacuum Pump Monitoring Using MPCA Statistical Method (MPCA 기반의 통계기법을 이용한 진공펌프 상태진단에 관한 연구)

  • Sung D.;Kim J.;Jung W.;Lee S.;Cheung W.;Lim J.;Chung K.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.338-346
    • /
    • 2006
  • In semiconductor process, it is so hard to predict an exact failure point of the vacuum pump due to its harsh operation conditions and nonlinear properties, which may causes many problems, such as production of inferior goods or waste of unnecessary materials. Therefore it is very urgent and serious problem to develop diagnostic models which can monitor the operation conditions appropriately and recognize the failure point exactly, indicating when to replace the vacuum pump. In this study, many influencing factors are totally considered and eventually the monitoring model using multivariate statistical methods is suggested. The pivotal algorithms are Multiway Principal Component Analysis(MPCA), Dynamic Time Warping Algorithm(DTW Algorithm), etc.

A Study on the Infrared Thermographic Imaging in Diagnosis of the Central Type of Herniated Disc (중앙형 추간판탈출증의 진단에서 체열촬영의 의의)

  • Song Bong-Keun;Lee Jong-Duk;Pak Yong-Hyun;Song Un-Yong;Kim Jung-Gyl
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.301-310
    • /
    • 1998
  • Infrared thermographic imaging visualizes noninvasively various abnormal condition by detecting the skin temperature. As the imaging represents the objective condition by the changes in blood flow under the control of autonomic nervous system, it is used to diagnosis and monitor the lumboscral radiculopathy. And asymmetry is important in the diagnosis of disc herniation. The most common type of disc herniation occurs psoterolaterally. This frequently causes nerve root compression leading to a radiculopathy in the distribution of the involved nerve root, most of which also provoke the asymmetric changes in thermography. Central disc herniation, which accounts for 5% to 35% of disc herniation, is typically associated with low back pain. But radiculopathy is usually abscent unless central disc heriniaton is large enough to cause compression of the cauda equina. To evalute the diagnostic value of the thermographic imaging in the diagnosis of central disc herniation, the imaging of 15 normal subjects and 48 patients with central disc herniation documented by CT scan were analyzed. The patients had either bilateral radiculophathy or no radiculopathy. The imaging of patient group with non rediculopathy did not show any significant thermal difference to control. While bilateral radiculopathy group reveled hypothermic pattern compared twith control. Thermal difference between left and right side did not present any significance in non radiculopathy group but hypothermia in bilateral radiculopathy group. Large herniation group demonstrated hyperthemic pattern while the others showed no significant change. Cranial caudal thermal difference did not show any difference between experiment groups. These results shows that infrared thermographic imaging can be used central disc herniation with bilateral radiculopathy, while it seems to little useful on the diagnosis of non radiculopathic disc herniation.

  • PDF

Factors Predictive of Treatment by Australian Breast Surgeons of Invasive Female Breast Cancer by Mastectomy rather than Breast Conserving Surgery

  • Roder, David;Zorbas, Helen;Kollias, James;Pyke, Chris;Walters, David;Campbell, Ian;Taylor, Corey;Webster, Fleur
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.539-545
    • /
    • 2013
  • Background: The National Breast Cancer Audit Database of the Society of Breast Surgeons of Australia and New Zealand is used by surgeons to monitor treatment quality and for research. About 60% of early invasive female breast cancers in Australia are recorded. The objectives of this study are: (1) to investigate associations of socio-demographic, health-system and clinical characteristics with treatment of invasive female breast cancer by mastectomy compared with breast conserving surgery; and (2) to consider service delivery implications. Materials and Methods: Bi-variable and multivariable analyses of associations of characteristics with surgery type for cancers diagnosed in 1998-2010. Results: Of 30,299 invasive cases analysed, 11,729 (39%) were treated by mastectomy as opposed to breast conserving surgery. This proportion did not vary by diagnostic year (p>0.200). With major city residence as the reference category, the relative rate (95% confidence limits) of mastectomy was 1.03 (0.99, 1.07) for women from inner regional areas and 1.05 (1.01, 1.10) for those from more remote areas. Low annual surgeon case load (${\leq}10$) was predictive of mastectomy, with a relative rate of 1.08 (1.03, 1.14) when compared with higher case loads. Tumour size was also predictive, with a relative rate of 1.05 (1.01, 1.10) for large cancers (40+ mm) compared with smaller cancers (<30 mm). These associations were confirmed in multiple logistic regression analysis. Conclusions: Results confirm previous studies showing higher mastectomy rates for residents of more remote areas, those treated by surgeons with low case loads, and those with large cancers. Reasons require further study, including possible effects of surgeon and woman's choice and access to radiotherapy services.

Full mouth prosthodontic reconstruction on patient with occlusion collapse & decreased vertical dimension (교합 붕괴 환자의 수직고경거상을 동반한 완전 구강회복 증례)

  • Yoo, H.J.;Choi, M.H.;Kim, C.H.;Park, Y.R.;Kang, D.W.
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.115-124
    • /
    • 2003
  • One of the important things in the full mouth reconstruction is the determination of therapeutic position. Centric jaw relation is used as a therapeutic position for the full mouth reconstruction. There are several techniques associated with recording this position. Five clinically acceptable techniques are as follows: 1) Swallowing or free closure, 2) Chin point guidance, 3) Bimanual method 4) Myo-monitor technique, 5) Anterior deprogrammer. Centric relation obtained utilizing the anterior acrylic resin platform in this case. Another important thing in full mouth reconstruction is provisional restoration. Provisional restorations are an excellent diagnostic instrument, especially in full remain esthetics, phonetics, function, parafunction, and dysfunction after evaluation and acceptance through clinical trial with the provisional restorations should be accurately transferred to the final restorations to ensure the same clinical success. Especially, anterior guidance should be accurately transferred to the final restorations. An accurate anterior guidance is critical for optimal esthetics, phonetics, comfort, function, stress minimization, and longevity of teeth and restorations. To record optimum anterior guidance, customized anterior guide table is used in this case. Considering previously mentioned points, we did successive treatment. And it resulted in a better situation esthetically and functionally. Followings are what we cared in treating a patient in this case. 1) Accurate centric relation recording 2) Accurate transference of anterior guidance to the final restorations.

Decision on Compression Ratios for Real-Time Transfer of Ultrasound Sequences

  • Lee, Jae-Hoon;Sung, Min-Mo;Kim, Hee-Joung;Yoo, Sun-Kwook;Kim, Eun-Kyung;Kim, Dong-Keun;Jung, Suk-Myung;Yoo, Hyung-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.489-491
    • /
    • 2002
  • The need for video diagnosis in medicine has been increased and real-time transfer of digital video will be an important component in PACS and telemedicine. But, Network environment has certain limitations that the required throughput can not satisfy quality of service (QoS). MPEG-4 ratified as a moving video standard by the ISO/IEC provides very efficient video coding covering the various ranges of low bit-rate in network environment. We implemented MPEG-4 CODEC (coder/decoder) and applied various compression ratios to moving ultrasound images. These images were displayed in random order on a client monitor passed through network. Radiologists determined subjective opinion scores for evaluating clinically acceptable image quality and then these were statistically processed in the t-Test method. Moreover the MPEG-4 decoded images were quantitatively analyzed by computing peak signal-to-noise ratio (PSNR) to objectively evaluate image quality. The bit-rate to maintain clinically acceptable image quality was up to 0.8Mbps. We successfully implemented the adaptive throughput or bit-rate relative to the image quality of ultrasound sequences used MPEG-4 that can be applied for diagnostic performance in real-time.

  • PDF

A Study on the assessment of stress using Wireless ECG (무선 심전도측정을 통한 스트레스 평가에 관한 연구)

  • Lim, Chae-Young;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2011
  • In this paper, daily life stress monitoring system is proposed. The proposed wireless ECG module, reducing the noise and increasing the size of signal, amplification circuit was designed for. Using HRV(Heart Rate Variability), extracted by measuring R-wave, stress diagnostic algorithms to assess the stress of human emotion were developed. For monitoring the activities, the proposed system is consist of small rectangular size for portable and by simple measurement it is possible to measure at any time. Through experiments, the proposed approach to represent user's stress level can be confirmed. Through that, it can see appropriate structure to obtain R-wave for stress assess as well as high resemblance to the clinical electrocardiogram. In this paper, performed experiments was developed nonrestraint measuring and wearable wireless biometric scanner that is able to monitor the heart's electrical activity of everyday life.Using this, the algorithm system, that is able to assess stress index through time-domain and frequency-domain analysis of the front and the rear of performing stress load protocol, was developed,

Grid Noise Removal in Computed Radiography Images Using the Combined Wavelet Packet-Fourier Method (CR영상에서 웨이블릿 패킷-푸리에 방법을 이용한 그리드 잡음 제거)

  • Lee, A Young;Kim, Dong Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.175-182
    • /
    • 2012
  • The scattered radiation always occurs when X-ray strikes the object. To absorb the scattered X-rays, the antiscatter grids are used, however these grids images are superimposed in the projection radiography images. When those images are displayed on the monitor, moir$\acute{e}$ patterns are overlapped over the images and disturb the anatomical informations. Most of the researches performed to date removed the grid noises by calculating or observing those frequencies in one dimensional frequency domain, two dimensional wavelet transform or Fourier transform. Those methods filtered not only the grid noises but also diagnostic informations. In this paper, we proposed the combined wavelet packet-Fourier method to remove the grid artifact in CR images. For the phantom image, the proposed method achieved from 5.2 to 7.4 dB better than others in SNR and for CR images by rejecting the grid noise bands effectively while leaving the remaining bands unchanged, the loss of images could get minimal results.

Improvement Research of BLE-based System for Monitoring the cause of Breakdown of Automatic Doors (자동문의 고장원인을 모니터링하기 위한 BLE 기반의 시스템 개선연구)

  • Kim, Gi-Doo;Won, Seo-Yeon;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.93-102
    • /
    • 2017
  • Recently increasing usage of smartphones makes the Internet of Things (IoT) a leading technology that can collect and share data through sensor networks and wireless communication such as low-power Bluetooth (BLE). BLE-based application can provide operators more precise information on Automatic Door system by remotely diagnosing the system faults through wireless sensor networks and sensors around the Automatic Door. In this paper, a smart device with extended BLE module is implemented which can monitor and Control the system states and faults remotely without on-site diagnostic. while maintaining system integrity so that increase efficiency of time and costs for system management. We can use the results of this research as a basis in evaluating reliability of data between devices, extending communication module in Controller of obsolete Door systems, and establishing centralized monitoring systems in near future with multi-channel Door Controls.

Prevalence and Risk Factors of Anxiety, Depression, and Post-Traumatic Stress Disorder in Critical Care Survivors (중환자실 퇴원 환자의 불안, 우울, 외상 후 스트레스 장애 유병률 및 위험요인)

  • Kang, Ji Yeon;An, Geum Ju
    • Journal of Korean Critical Care Nursing
    • /
    • v.13 no.3
    • /
    • pp.62-74
    • /
    • 2020
  • Purpose : This study aimed to investigate the prevalence and risk factors of mental health problems in patients discharged from the intensive care unit (ICU). Methods : This was a secondary analysis study using data from a multicenter prospective cohort of post-ICU patients. We analyzed data of 311 patients enrolled in the primary cohort study who responded to the mental health questionnaire three months after the discharge. Anxiety and depression were measured on the Hospital Anxiety-Depression Scale, and post-traumatic stress disorder (PTSD) was measured on the Posttraumatic Diagnostic Scale. Results : The prevalence of anxiety, depression, and PTSD in patients at three months after ICU discharge were 25.7%, 17.4%, and 18.0%, respectively, and 7.7% of them experienced all three problems. Unemployment (OR=1.99, p=.033) and unplanned ICU admission (OR=2.28, p=.017) were risk factors for depression, while women gender (OR=2.34, p=.009), comorbid diseases (OR=2.88, p=.004), non-surgical ICUs (trauma ICU: OR=7.31, p=.002, medical ICU: OR=3.72, p=.007, neurological ICU: OR=2.95, p=.019) and delirium (OR=2.89, p=.009) were risk factors for PTSD. Conclusion : ICU nurses should proactively monitor risk factors for post-ICU mental health problems. In particular, guidelines on the detection and management of delirium in critically ill patients should be observed.