• Title/Summary/Keyword: Diagnostic error

Search Result 224, Processing Time 0.025 seconds

Diagnostic System of Modeling Errors Generated from IGES CAD Data Exchange (IGES CAD 데이터의 교환에서 오류 진단 시스템)

  • Park, Sang-Ho;Park, Jong-Wook;Han, Soon-Heung;Choi, Young;Yang, Jung-Sam;Lee, Byung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.218-225
    • /
    • 2003
  • A diagnostic system has been developed which reports modeling errors generated when exchanging CAD data using IGES (Initial Graphics Exchange Specification) format. The system determines whether the CAD data contains errors. It also helps to define the criteria for determining the integrity and interoperability of CAD data with downstream applications of another CAD/CAM/CAE/PDM systems. The methodology of our algorithms is to analyze IGES model data by identifying errors and anomalies with respect to the diagnosis of geometry and topology. The GUI (Graphic User Interface) of the developed system helps users to input values and to visualize diagnostic results at real time.

A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis (이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구)

  • ;;;Zeung Nam Bien
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

Effects of Intelligence Ability on Continuous Performance Test (지적 능력이 연속수행과제(CPT) 수행에 미치는 영향)

  • Lee Ji-Yeon;Cho A-Ra;Kim Bong-Seog;Kim Joo-Hee
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.17 no.2
    • /
    • pp.163-169
    • /
    • 2006
  • Objectives : The study was conducted to investigate the effect of intelligence ability on attention using Continuous Performance Test (CPT). Methods : 56 children with ADHD (52 boys, 4 girls) and 41 children in normal (28 boys, 13 girls) were sampled, their age range was 7 to 15. They performed IQ test and ADHD Diagnostic System (ADS) in order to examine intelligence and attention. Participants were divided into normal group and ADHD group, average IQ level children and superior IQ level children. Then ADS variables (omission error, commission error, reaction time, reaction time deviation, response sensitivity, and response criterion) were analyzed. Results : There was no significant interaction effect between group (normal, ADHD) and intelligence (average, superior). But there was significant difference between normal group and ADHD group in omission error, commission error, reaction time deviation, and response sensitivity. Also average level IQ group had significantly showed more omission, greater reaction time deviation, and lower response sensitivity than superior level IQ group. Conclusion : ADHD group has attention deficit than normal group, and CPT is available tool to detect attention problems. These findings indicate that intelligence can contaminate inattention and cognitive impulsivity thus it compensates for attention deficit. And it suggests that intelligence effect is considered in analyzing CPT in ADHD children.

  • PDF

Diagnostic Accuracy of Cervicovaginal Cytology in the Detection of Squamous Epithelial Lesions of the Uterine Cervix; Cytologic/Histologic Correlation of 481 Cases (자궁경부 편평상피병변에서 자궁경부질도말 세포검사의 진단정확도 : 481예의 세포-조직 상관관계)

  • Jin, So-Young;Park, Sang-Mo;Kim, Mee-Sun;Jeen, Yoon-Mi;Kim, Dong-Won;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.111-118
    • /
    • 2008
  • Background : Cervicovaginal cytology is a screening test of uterine cervical cancer. The sensitivity of cervicovaginal cytology is less than 50%, but studies of cytologic/histologic correlation are limited. We analyzed the diagnostic accuracy of cervicovaginal cytology in the detection of the squamous epithelial lesions of the uterine cervix and investigate the cause of diagnostic discordance. Materials and Methods : We collected a total of 481 sets of cervicovaginal cytology and biopsies over 5 years. The cytologic diagnoses were categorized based on The Bethesda System and the histologic diagnoses were classified as negative, flat condyloma, cervical intraepithelial neoplasia (CIN) I, CIN II, CIN III, or squamous cell carcinoma. Cytohistologic discrepancies were reviewed. Results: The concordance rate between the cytological and the histological diagnosis was 79.0%. The sensitivity and specificity of cervicovaginal cytology were 80.6% and 92.6%, respectively. Its positive predictive value and negative predictive value were 93.7% and 77.7%, respectively. The false negative rate was 19.4%. Among 54 false negative cytology cases, they were confirmed by histology as 50 flat condylomas, 2 CIN I, 1 CIN III, and 1 squamous cell carcinoma. The causes of false negative cytology were sampling errors in 75.6% and interpretation errors in 24.4%. The false positive rate was 7.4%. Among 15 false positive cytology cases, they were confirmed by histology as 12 atypical squamous cells of undetermined significance (ASCUS) and 3 low grade squamous intraepithelial lesions (LSIL). The cause of error was interpretation error in all cases. The overall diagnostic accuracy of cervicovaginal cytology was 85.7%. Conclusions : Cervicovaginal cytology shows high overall diagnostic accuracy and is a useful primary screen of uterine cervical cancer.

Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity (지능형 대용량 비례유량제어밸브 서보컨트롤러 설계)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

Inter-Process Correlation Model based Hybrid Framework for Fault Diagnosis in Wireless Sensor Networks

  • Zafar, Amna;Akbar, Ali Hammad;Akram, Beenish Ayesha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.2
    • /
    • pp.536-564
    • /
    • 2019
  • Soft faults are inherent in wireless sensor networks (WSNs) due to external and internal errors. The failure of processes in a protocol stack are caused by errors on various layers. In this work, impact of errors and channel misbehavior on process execution is investigated to provide an error classification mechanism. Considering implementation of WSN protocol stack, inter-process correlations of stacked and peer layer processes are modeled. The proposed model is realized through local and global decision trees for fault diagnosis. A hybrid framework is proposed to implement local decision tree on sensor nodes and global decision tree on diagnostic cluster head. Local decision tree is employed to diagnose critical failures due to errors in stacked processes at node level. Global decision tree, diagnoses critical failures due to errors in peer layer processes at network level. The proposed model has been analyzed using fault tree analysis. The framework implementation has been done in Castalia. Simulation results validate the inter-process correlation model-based fault diagnosis. The hybrid framework distributes processing load on sensor nodes and diagnostic cluster head in a decentralized way, reducing communication overhead.

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

Comparison of Fine Needle Aspiration Cytologic Diagnoses and Histologic Diagnoses in 256 Breast Lesions (유방 병변 256례의 세침흡인 세포학적 진단 및 조직학적 진단과의 비교연구)

  • Kang, Mi-Seon;Jung, Soo-Jin;Yoon, Hye-Kyoung
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.2
    • /
    • pp.120-128
    • /
    • 1997
  • Fine needle aspiration cytology of breast lesion is well known as a simple, economic and effective diagnostic modality. For the evaluation of cytohistologic correlation, 256 cases of cytologic smears and subsequent histologic sections during 2-year period from Jan. 1995 to Dec. 1996 were reviewed. 1. Fifteen cases(5.9%) were proven as insufficient for evaluation, and 13 of them were fibrocystic change histologically. One case of carcinoma exhibiting sufficient amount of aspirates with no malignant cells on smear was regarded as inadequate. 2. Cytohistologic correlation of 240 cases revealed sensitivity 87.0%, specificity 100.0%, positive predictive value 100.0%, negative predictive value 97.0%, false positive rate 0.0% and false negative rate 13.0%. Total diagnostic accuracy is 95.7%. 3. Total 6 cases of negative were due to small amount of aspirates containing scantiness of malignant cells in two and underestimation in four. 4. Diagnostic concordance rates of fibrocystic change and fibroadenoma were 95.5% and 80.0%, respectively. Diagnostic discrepancies were noted in 7 cases of fibrocystic change and 6 cases of fibroadenoma, however, cytologic discrimination of two entities was not easy in seven of them. 5. In a case of phyllodes tumor and a case of duct ectasia, the discrepancy was due to targeting error. Other three cases(lymphoma, adenomyoepithelioma and granulomatous mastitis) were misinterpreted because of poor acquaintance with those entities. Diagnostic accuracy of fine needle aspiration cytology of breast lesions are relatively high. However, good technique on aspiration and adequate interpretation are necessary to reduce the false negative rate and the discrepancy between cytologic and histologic diagnoses.

  • PDF

Study on the K-scale reflecting the confidence of survey responses (설문 응답에 대한 신뢰도를 반영한 K-척도에 관한 연구)

  • Park, Hye Jung;Pi, Su Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.1
    • /
    • pp.41-51
    • /
    • 2013
  • In the Information age, internet addiction has been a big issue in a modern society. The adverse effects of the internet addiction have been increasing at an exponential speed. Along with a great variety of internet-connected device supplies, K-scale diagnostic criteria have been used for the internet addiction self-diagnose tests in the high-speed wireless Internet service, netbooks, and smart phones, etc. The K-scale diagnostic criteria needed to be changed to meet the changing times, and the diagnostic criteria of K-scale was changed in March, 2012. In this paper, we analyze the internet addiction and K-scale features on the actual condition of Gyeongbuk collegiate areas using the revised K-scale diagnostic criteria in 2012. The diagnostic method on internet addiction is measured by the respondents' subjective estimation. Willful error of the respondents can be occurred to hide their truth. In this paper, we add the survey response to the trusted reliability values to reduce response errors on the K-scale on the K-scale, and enhance the reliability of the analysis.