• 제목/요약/키워드: Diagnostic accuracy rate

검색결과 167건 처리시간 0.03초

일본인용 사상체질진단지의 타당화 연구 (A Validation Study of the Sasang Constitution Questionnaire for Japanese(SSCQ-J))

  • 조훈석;전수형;정종훈;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제25권4호
    • /
    • pp.289-296
    • /
    • 2013
  • Objectives This study was aimed to validate Sasang Constitution Questionnaire for Japanese (SSCQ-J). Methods Sasang Constitution Questionnaire for Patients (SSCQ-P) was developed by joint researches between the Society of Sasang Constitutional Medicine and Korea Institute of Oriental Medicine. We translated SSCQ-P into Japanese and modified some items of that for Japanese. By getting approval from the Institutional Review Board(IRB)of School of Medicine, Keio University, we conducted a questionnaire survey of patients who visited Oriental Medicine Center from early January until mid-February 2011. The total of 364 patients filled out that Questionnaire and gave an interview with a Sasang constitution specialist. Using this Questionnaire data, we made Sasang constitutional classification functions and calculated diagnostic accuracy rate of SSCQ-J using discrimination analysis. Results 1. Male group's diagnostic accuracy rate of SSCQ-J was 77.01% and female was 78.10%. 2. Diagnostic accuracy of SSCQ-J was a little higher than SSCQ-P Conclusions 1. SSCQ-J can be considered to have good discriminant power compared with SSCQ-P 2. Further research with SSCQ-J will be helpful in the comparison study on the usual symptoms between Korean and Japanese as well as development of good discriminant function.

유방암에서 PET의 응용 (Application of PET in Breast Cancer)

  • 노동영
    • 대한핵의학회지
    • /
    • 제36권1호
    • /
    • pp.34-38
    • /
    • 2002
  • Positron emission tomography(PET) is an imaging method that employs radionuclide and tomography techniques. Since 1995, we applied PET not only to the diagnosis of breast cancer but also to the detection of abnormalities in the augmented breast and to the detection of metastasis. Until 2001, we evaluated 242 breast cases by PET at PET center of Seoul National University Hospital. Our group has reported serially at the international journals. In the first report, PET showed high sensitivity for detecting breast cancer, both the primary and axillary node metastasis. A total of 27 patients underwent breast operations based on PET results at Seoul National University Hospital from 1995 to 1996. The diagnostic accuracy of PET were 97% for the primary tumor mass and 96% for axillary lymph node metastasis. In case of the breast augmented, PET also showed excellent diagnostic results for primary breast cancer and axillary lymph node metastasis where mammography and ultrasound could not diagnose properly. PET also had outstanding results in the detection of recurrent or metastatic breast cancer(sensitivity 94%, specificity 80%, accuracy 89%). In addition, our study gave some evidence that PET could be applied further to evaluate the growth rate of tumors by measuring SUV, and finally to prognosticated the disease. PET could also be applied to evaluate the response after chemotherapy to measure its metabolic rate and size. In conclsion, PET is a highly sensitive, accurate diagnostic tool for breast cancer of primary lesion in various conditions including metastasis.

Urinary Concentrations of Human Epidydimis Secretory Protein 4 (He4) in The Diagnosis of Ovarian Cancer: A Case-Control Study

  • Macuks, Ronalds;Baidekalna, Ieva;Donina, Simona
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권9호
    • /
    • pp.4695-4698
    • /
    • 2012
  • Objective: To analyze differential diagnostic accuracy of urinary human epidydimis secretory protein 4 (HE4) in patients with ovarian tumors. Materials and methods: In the case-control study 23 patients with ovarian cancer, 37 patients with benign ovarian tumors and 18 women in the control group were included. Serum CA125 values and urinary concentrations of HE4were assessed quantitatively. Urinary creatinine concentrations and glomerular filtration rate were also determined and used to calculate ratios to HE4. Results: Higher urinary HE4 concentrations were observed in patients with late stage ovarian cancer (p=0.001) and also in patients with early stage ovarian cancer when compared to patients with benign ovarian tumors (p=0.044). On analysis where all ovarian cancer patients were included, higher diagnostic accuracy was observed with calculated ratio of HE4 to glomerular filtration rate (GFR) to unchanged urinary HE4 concentrations -AUC 0.861 vs. 0.858. When discriminatory accuracy was calculated for urinary HE4/GFR ratio and unchanged urinary HE4 concentrations, the last demonstrated a higher area under the curve - 0.701 vs. 0.602. The urinary HE4/creatinine ratio had lower discriminatory characteristics than unchanged concentrations of urinary HE4. However, HE4 serum concentration was more accurate for discrimination of patients with benign and malignant ovarian tumors when compared to urinary HE4 and CA125 in sera (AUCs were 0.868 for serum HE4 and 0.856 and 0.653 for urinary HE4 and CA125, respectively). Conclusions: Ovarian cancer patients have higher urinary concentrations of human epidydimis secretory protein 4 than patients with benign ovarian tumors. Urinary HE4 has comparable discriminatory accuracy with serum HE4 for benign and malignant ovarian tumors and can be recommended as a non-invasive ovarian cancer risk assessment method.

환자용 사상체질설문지(SSCQ-P) 축소화에 관한 연구 (A Study about a Short-form of the Sasang Constitution Questionnaire for Patient (SSCQ-P))

  • 정종훈;전수형;나영주;강석환;동상옥;이시우;김규곤;김종원;김상혁
    • 사상체질의학회지
    • /
    • 제26권4호
    • /
    • pp.339-349
    • /
    • 2014
  • Objectives This study was performed to make a short-form of Sasang Constitution Questionnaire for Patient(SSCQ-P). Methods In order to select important questions of SSCQ-P, we got advice from 10 professors of Oriental Medicine. As a result, we chose 37 questions. In addition, we selected 69 questions which had been used more than 12 times in SSCQ-P as the variable. We used some statistical methods to reduce questions. Finally, a total of 40 questions were selected. To find diagnostic accuracy rate of this short-form, discriminant analysis was performed. We used 1378 cases which was collect ed from February 2008 to June 2013 by online system(Sasang-medi data which has selected by web site, http://www.sasangmedi.or.kr), and 68 cases which was collected from November 2006 to September 2007 by the research "Construction of a biological information collection system for the Constitutional scientific diagnosis"(Korea Constitutional Multicenter Bank data, KCMB data) Results We made a short-form of SSCQ-P consisting of 40 questions. Diagnostic accuracy rate of short-form is 66.18% using Sasang-medi data, and 42.65% using KCMB data. Conclusions More cases are needed to improve the diagnostic accuracy rate of this short-form.

갑상선 병변의 세침흡인 세포검사의 유용성에 관한 연구 (A Study of Usefulness of Fine Needle Aspiration Cytology of the Thyroid Lesions)

  • 진계현;진소영;이동화
    • 대한세포병리학회지
    • /
    • 제7권2호
    • /
    • pp.111-121
    • /
    • 1996
  • Fine needle aspiration cytology(FNAC) is preferred because of simplicity, safety, and reliability in the evaluation of patients with thyroid nodule or hyperplasia. However, there are a few limitations such as false-negative or false-positive cases and non-diagnostic material. To evaluate the usefulness of FNAC in thyroid lesions, we reviewed 704 FNAC cases of thyroid nodules from 1988 to 1994 at Soonchunhyang University Hospital. The results are as follows. 1. Among 704 FNAC cases of thyroid gland, 571(81.1%) cases were benign, 12(1.7%) were suspicious, 71(10.1%) were malignancy, and 50(7.1%) were material insufficiency. The cytologic diagnoses of the benign lesions included 168 cases of follicular neoplasm, 139 cases of adenomatous goiter, 162 cases of follicular lesion such as follicular neoplasm or adenomatous goiter, 61 cases of Hashimoto's thyroiditis, 13 cases of subacute thyroiditis, and 28 cases of colloidal nodule or benign nodule. The malignant lesions included 68 cases of papillary carcinona, two medullary carcinomas and a case of metastatic colon cancer. 2. The average number of cytologic smear slides was $4.12{\pm}1.81$ in material insufficiency and $5.63{\pm}1.79$ in diagnostic cases. This difference was statistically significant(p<0.00001). 3. Histological assessment of 150 cases revealed 2 false negative and 1 false positive cases. The false negative cases were a case of marked sclerosis in papillary carcinoma and an occult case of papillary carcinoma. The false positive case resulted from pseudo-ground glass nuclei due to marked dry artifact. 4. Comparison between the FNAC and the histologic diagnosis revealed that FNAC had a sensitivity of 93.5%, a specificity of 99.2%, a false negative rate of 6.6%, a false positive rate of 0.8%, and an overall diagnostic accuracy of 98.0%. Therefore, FNAC of thyroid gland is a very reliable diagnostic method with excellent accuracy rate.

  • PDF

정위적 뇌생검의 임상분석 (Clinical Analysis of Stereotactic Biopsy in Brain Lesions)

  • 김영욱;김재휴;서승권;이정길;김태선;정신;김수한;강삼석;이제혁
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권1호
    • /
    • pp.15-22
    • /
    • 2000
  • Objective : This study was undertaken to evaluate the benefits and risks of the stereotactic biopsy in brain lesions. We assessed the diagnostic accuracy and morbidity rate associated with the stereotactic biopsy. Methods : The authors present a review of 47 patients, who underwent stereotactic biopsy using Cosman-Roberts-Wells(CRW) stereotactic apparatus during last six years. Results : Target locations were supratentorial in 36 cases, infratentorial in 9 and multiple in 2. According to pathological diagnosis, the largest group was neoplasm(29) followed by infection(9), infarction(2), cyst(2), and non-specific(5). Definitive diagnosis could be made in 42 of 47 cases(89.4%). When the mass lesion had been suspected as neoplastic condition, the diagnostic rate was 96.7%(29/30). It was being much higher than that of non-neoplastic lesion, 76.5%(13/17). The treatment modality was changed in 15 cases(32%) because the result of stereotactic biopsy was different from clinical diagnosis. Subsequent craniotomy after stereotactic biopsy was then performed in 6 cases, and the pathological diagnoses were precisely coincident in all of these cases. There were two complications(4.3%) : One intratumoral hemorrhage in glioblastoma and a transient hemiparesis in benign astrocytoma. There was no mortality in this series. Conclusion : The precise histological verification is crucial to determine the adequate treatment modality in intracranial lesions. Stereotactic biopsy is a safe and accurate diagnostic procedure for intracranial lesions with a low complication rate.

  • PDF

성별을 고려한 중풍 변증진단 판별모형개발(V) (Discriminant Model V for Syndrome Differentiation Diagnosis based on Sex in Stroke Patients)

  • 강병갑;이정섭;고미미;권세혁;방옥선
    • 동의생리병리학회지
    • /
    • 제25권1호
    • /
    • pp.138-143
    • /
    • 2011
  • In spite of abundant clinical resources of stroke patients, the objective and logical data analyses or diagnostic systems were not established in oriental medicine. As a part of researches for standardization and objectification of differentiation of syndromes for stroke, in this present study, we tried to develop the statistical diagnostic tool discriminating the 4 subtypes of syndrome differentiation using the essential indices considering the sex. Discriminant analysis was carried out using clinical data collected from 1,448 stroke patients who was identically diagnosed for the syndrome differentiation subtypes diagnosed by two clinical experts with more than 3 year experiences. Empirical discriminant model(V) for different sex was constructed using 61 significant symptoms and sign indices selected by stepwise selection. We comparison. We make comparison a between discriminant model(V) and discriminant model(IV) using 33 significant symptoms and sign indices selected by stepwise selection. Development of statistical diagnostic tool discriminating 4 subtypes by sex : The discriminant model with the 24 significant indices in women and the 19 significant indices in men was developed for discriminating the 4 subtypes of syndrome differentiation including phlegm-dampness, qi-deficiency, yin-deficiency and fire-heat. Diagnostic accuracy and prediction rate of syndrome differentiation by sex : The overall diagnostic accuracy and prediction rate of 4 syndrome differentiation subtypes using 24 symptom and sign indices was 74.63%(403/540) and 68.46%(89/130) in women, 19 symptom and sign indices was 72.05%(446/619) and 70.44%(112/159) in men. These results are almost same as those of that the overall diagnostic accuracy(73.68%) and prediction rate(70.59%) are analyzed by the discriminant model(IV) using 33 symptom and sign indices selected by stepwise selection. Considering sex, the statistical discriminant model(V) with significant 24 symptom and sign indices in women and 19 symptom and sign indices in men, instead of 33 indices would be used in the field of oriental medicine contributing to the objectification of syndrome differentiation with parsimony rule.

유방 세침흡인 세포검사의 진단적 함정: 위양성과 위음성 (Diagnostic Pitfalls in Breast Fine Needle Aspiration Cytology: False Positive and False Negative)

  • 박경미
    • 대한세포병리학회지
    • /
    • 제18권2호
    • /
    • pp.112-118
    • /
    • 2007
  • Fine needle aspiration cytology (FNAC) has become a highly preferred, minimally invasive diagnostic tool of choice in the diagnosis of a palpable breast mass owing to its sensitivity, specificity, cost-effectiveness, and expediency. Although breast needle biopsies have been widely employed recently due to the increased detection rate of non-palpable early lesions, the importance of the use of FNAC cannot be underestimated. It comprises part of the diagnostic triad for the breast along with a physical examination and mammography, which together contribute to an increasing diagnostic accuracy. The differential diagnosis of a benign and malignant lesion is of the utmost importance in the diagnosis of breast lesions, and therefore the understanding of the possible diagnostic pitfalls is of great importance.

구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구 (CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS)

  • 김재환;김경욱;김용각
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle - a Clinical Trial

  • Sanam, Moradan;Majid, Mir Mohammad Khani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.4971-4975
    • /
    • 2015
  • Background: Several methods have been presented for the evaluation of the endometrium in patients with abnormal uterine bleeding, which include minimal invasive and invasive approaches such as diagnostic curettage or endometrial biopsy by Pipelle. Many studies have been performed in order to compare two methods; diagnostic curettage and outpatient endometrial biopsy. This investigation compared sampling adequacy, endometrial histopathology, failure rates, duration and costs between diagnostic curettage in a hospital and endometrial biopsy. Materials and Methods: This single blind clinical trial was performed on 130 patients older than 35 years who was referred to Amir training hospital in 2013 for elective diagnostic curettage because of abnormal uterine bleeding. For all patients eligible for the study, an endometrial sample by Pipelle was taken without anesthesia or dilatation. Then under general anesthesia diagnostic curettage was performed by sharp curette. Sampling duration was calculated and both samples were sent to the same pathologist. The diagnostic values of two methods in the diagnosis of normal endometrium, endometrial hyperplasia and carcinoma were compared. The costs of these two methods were also compared. Data analysis was performed by SPSS (version 16.0) software. Chi-Square, Fisher, and Pearson tests were used and were considered statistically significant at P values less than 0.05. Results: Two methods were agreed upon 88% of sampling adequacy and 94% of pathological results. Specificity of 100% and sensitivity of 90% for detection of proliferative endometrium, secretory endometrium, simple hyperplasia without atypia and 100% for cancer were recorded. Pipelle diagnostic accuracy in comparison with curettage, have been reported over 97%, so the failure rate in this study was below 5%. Sensitivity of Pipelle for detection of atrophic endometrium was reported below 50%. Duration and cost was lower in Pipelle versus curettage. Conclusions: It is concluded that due to high agreement and cohesion coefficient between curettage and Pipelle on the issue of sampling adequacy, histopathology finding (except atrophic endometrium), low failure rate, duration of sampling and cost, Pipelle can be introduced as a suitable alternative of diagnostic curettage.