• 제목/요약/키워드: Diagnostic Tool

검색결과 1,043건 처리시간 0.028초

유전자 알고리듬을 이용한 다중이상치 탐색

  • 고영현;이혜선;전치혁
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2000년도 추계학술발표회 논문집
    • /
    • pp.173-179
    • /
    • 2000
  • Genetic algorithm(GA) is applied for detecting multiple outliers. GA is a heuristic optimization tool solving for near optimal solution. We compare the performance of GA and the other diagnostic measures commonly used for detecting outliers in regression model. The results show that GA seems to have better performance than the others for the detection of multiple outliers.

  • PDF

소각장과 펌프의 이상소음 제어 (A Noise Control of the Incineration Plant and the Pump)

  • 주원호;박진화;배종국;정균양
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.741-746
    • /
    • 1998
  • A severe noise in industrial field can be sometimes generated from unexpected installation error and misunderstanding of industrial machinery. To solve the noise problem, the diagnostic tool is generally applied to identify the noise source and to detect the fault of machinery. And then, the suitable control countermeasure corresponding to the diagnostic results is presented. In this paper, two control cases an noise problem of the Incineration Plant and the Pump are introduced.

  • PDF

Comparative Assessment of Diagnostic Performances of Two Commercial Rapid Diagnostic Test Kits for Detection of Plasmodium spp. in Ugandan Patients with Malaria

  • Bahk, Young Yil;Park, Seo Hye;Lee, Woojoo;Jin, Kyoung;Ahn, Seong Kyu;Na, Byoung-Kuk;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • 제56권5호
    • /
    • pp.447-452
    • /
    • 2018
  • Prompt diagnosis of malaria cases with rapid diagnostic tests (RDTs) has been widely adopted as an effective malaria diagnostic tool in many malaria endemic countries, primarily due to their easy operation, fast result output, and straightforward interpretation. However, there has been controversy about the diagnostic accuracy of RDTs. This study was conducted to evaluate the diagnostic performances of the 2 commercially available malaria RDT kits, RapiGEN Malaria Ag Pf/Pv (pLDH/pLDH) and Asan $EasyTest^{TM}$ Malaria Ag Pf/Pv (HRP-2/pLDH) for their abilities to detect Plasmodium species in blood samples collected from Ugandan patients with malaria. To evaluate the diagnostic performances of these 2 RDT kits, 229 blood samples were tested for malaria infection by microscopic examination and a species-specific nested polymerase chain reaction. The detection sensitivities for P. falciparum of Malaria Ag Pf/Pv (pLDH/pLDH) and Asan $EasyTest^{TM}$ Malaria Ag Pf/Pv (HRP-2/pLDH) were 87.83% and 89.57%, respectively. The specificities of the 2 RDTs were 100% for P. falciparum and mixed P. falciparum/P. vivax infections. These results suggest that the 2 RDT kits showed reasonable levels of diagnostic performances for detection of the malaria parasites from Ugandan patients. However, neither kit could effectively detect P. falciparum infections with low parasitaemia (<$500parasites/{\mu}l$).

림프절 세침흡인 세포검사의 진단적 유용성과 한계 - 생검으로 확진한 176 예의 분석 - (Diagnostic Usefulness and Limitation of Fine Needle Aspiration Cytology of Lymph Node - Analysis of 176 Cases Confirmed by Biopsy -)

  • 김희성;김대수;오영륜;고영혜;이회정
    • 대한세포병리학회지
    • /
    • 제10권1호
    • /
    • pp.35-42
    • /
    • 1999
  • The accuracy of fine needle aspiration cytology(FNAC) of the lymph node was investigated through a review of 176 FNAC cases and the corresponding biopsies. We chose 157 FNAC cases after the exclusion of 19 inadequate ones. Sensitivity of malignancy was 94.0%, specificity 100%, false negativity 6.0%, and false positivity 0.0%. The overall diagnostic accuracy was 96.8%. Sensitivity of metastatic carcinoma was 98.0% and that of malignant lymphoma was 87.9%. False negative cases included one metastatic carcinoma and four malignant lymphomas. The aspirates of metastatic carcinoma with false negativity exhibited a diffuse smear of keratin debris without viable cells, which led to the difficulty in differentiation from benign epithelial cyst. The cases of malignant lymphoma with false negative diagnosis were two Hodgkin diseases, one Lennert's lymphoma, and one peripheral T cell lymphoma in the histologic sections. On the analysis of 39 cases of tuberculosis, 17 cases(43.6%) were diagnosed as tuberculosis, 4(10.3%) as granulomatous lymphadenitis, 3(7.7%) as necrotizing lymphadenitis, and 15(38.5%) as reactive hyperplasia or pyogenic inflammation. Sensitivity of tuberculosis was 53.9%. In conclusion, lymph node FNAC is an excellent non-invasive diagnostic tool for the diagnosis of metastatic carcinoma. The diagnostic accuracy of malignant lymphoma could be improved with flow cytometry or polymerase chain reaction for antigen receptor genes. For the FNAC diagnosis of tuberculosis, AFB stain, culture, and PCR would be helpful as adjuvant techniques.

  • PDF

Usefulness of MR Imaging for Diseases of the Small Intestine: Comparison with CT

  • Ji-Hoon Kim;Hyun Kwon Ha;Min Jee Sohn;Byung Suck Shin;Young Suk Lee;Soo Yoon Chung;Pyo Nyun Kim;Moon-Gyu Lee;Yong-Ho Auh
    • Korean Journal of Radiology
    • /
    • 제1권1호
    • /
    • pp.43-50
    • /
    • 2000
  • Objective: To evaluate the usefulness of MR imaging for diseases of the small intestine, emphasizing a comparison with CT. Materials and Methods: Thirty-four patients who underwent both CT and MR imaging using FLASH 2D and HASTE sequences were analyzed. All patients had various small bowel diseases with variable association of peritoneal lesions. We compared the detectabilities of CT and MR imaging using different MR pulse sequences. The capability for analyzing the characteristics of small intestinal disease was also compared. Results: MR imaging was nearly equal to CT for detecting intraluminal or peritoneal masses, lesions in the bowel and mesentery, and small bowel obstruction, but was definitely inferior for detecting omental lesions. The most successful MR imaging sequence was HASTE for demonstrating bowel wall thickening, coronal FLASH 2D for mesenteric lesions, and axial FLASH 2D for omental lesions. MR imaging yielded greater information than CT in six of 12 inflammatory bowel diseases, while it was equal to CT in six of seven neoplasms and inferior in five of seven mesenteric ischemia. In determining the primary causes of 15 intestinal obstructions, MR imaging was correct in 11 (73%) and CT in nine (60%) patients. Conclusion: MR imaging can serve as an alternative diagnostic tool for patients with suspected inflammatory bowel disease, small intestinal neoplasm or obstruction.

  • PDF

치매 한의진단 평가도구 적용 연구 (Study on the Application of Oriental Medical Evaluation to Dementia)

  • 김가나;배현수;황의완;조성훈
    • 동의신경정신과학회지
    • /
    • 제25권4호
    • /
    • pp.383-388
    • /
    • 2014
  • Objectives: Patients with dementia are increasing in Korea. So the importance of accurate diagnosis and treatment of dementia is growing. In this paper, we evaluated the result of employing the Korean medical diagnostic pattern as a tool in clinics. Methods: Patients diagnosed with Alzheimer's disease were evaluated using the Korean medical diagnostic pattern tool. Results: The number of patients with liver-kidney yin deficiency pattern/syndrome was 35. Analyzing the ratio difference between the 'liver-kidney yin deficiency' group and the 'not liver-kidney yin deficiency' group revealed that the ratio of the responses to the fourth question was less than zero. The ratio of the responses to the fifth, seventh, and eight questions were all less than 10%. The ratio of the responses to the first and second questions were greater than 30%. Conclusions: Of the six diagnostic patterns, liver-kidney yin deficiency was the greatest in the study subjects. The fourth question in the liver-kidney yin deficiency tool tests for the lack of appropriateness whereas the fifth, seventh, and eight questions test for lack of discrimination. Applying more weight to the first and second questions was an excellent choice to increase the discrimination.

A New Cancer Cell Detection Method Using an Infectivity-enhanced Adenoviral Vector

  • Uchino, Junji;Takayama, Koichi;Nakagaki, Noriaki;Shuo, Wang;Hisasue, Junko;Nakatom, Keita;Ohta, Keiichi;Hirano, Ryosuke;Tashiro, Naoki;Miiru, Izumi;Fujita, Masaki;Watanabe, Kentaro;Nakanishi, Yoichi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권11호
    • /
    • pp.5551-5556
    • /
    • 2012
  • Cytological examination is widely used as a diagnostic tool because of the ease of collecting cells from the involved area. However, the diagnostic yield of cytological examination is unsatisfactory; the reasons include sampling error, poorly prepared samples, small numbers of malignant cells, and low grades of cellular atypia. In this study, we focused on the high infectivity of adenovirus towards epithelial cells and applied the luciferase-expressing adenoviral vector to a new cancer cell detection tool. In addition, adenoviral infectivity was enhanced by modifying viral fiber proteins. The sensitivity of the diagnostic tool was tested using the NCI-H1299 lung cancer cell line, and validated in body fluid samples from cancer patients with a variety of etiology. Results showed that the adenovirus efficiently transfected NCI-H1299 with high sensitivity. Only 10 cancer cells were sufficient for detection of luciferase signals. In body fluid samples, the adenovirus confirmed the diagnosis for malignant and benign cancer, but not in non-epithelial cell derived samples. This study provides proof-of-concept for a more reliable and sensitive diagnostic tool for epithelium-derived cancer.

국내 노인의 근감소증과 운동기능저하증후군에 대한 분석 연구 (Analysis of the Correlation Between Sarcopenia and Locomotive Syndrome in the Elderly in Korea)

  • 김명철;천지연;김해인;정동근;배원식
    • 대한통합의학회지
    • /
    • 제10권2호
    • /
    • pp.1-11
    • /
    • 2022
  • Purpose : This study was conducted to assess the status of sarcopenia and locomotive syndrome in the Korean elderly population over 65 years of age by applying the recently updated screening tool for diagnostic evaluation of sarcopenia and locomotive syndrome. Methods : Sarcopenia and locomotive syndrome (LS) were diagnosed and evaluated in 210 Korean elderly people over 65 years of age. There were 36 patients in the "sarcopenia group", 164 in the "locomotive syndrome group", and 10 in the "normal group". The collected data were analyzed using the chi-square and Kruskal-Wallis tests. Results : The diagnostic evaluation of sarcopenia and LS showed the presence of sarcopenia in 9.05 % of males and 8.10% females among the Korean elderly population over 65 years of age. Prevalence of stage 1 locomotive syndrome (LS 1) was 95.24 %; stage 2, (LS 2) 36.19 %; and stage 3 (LS 3), 16.19 % among the study population. Both the sarcopenia diagnostic indicator and the LS evaluation indicators showed significant differences between the three groups. All the subjects in the sarcopenia group had LS; further, on comparison of the detailed composition ratio of each patient with LS, the prevalence of LS in the sarcopenia group was found to be: LS 1 41.67 %, LS 2 41.67 %, and LS 3 16.67 %, whereas in the LS group, it was found to be: LS 1 66.46 %, LS 2 16.46 %, and LS 3 17.07 %. The difference between the two groups was statistically significant. Conclusion : It was confirmed that sarcopenia is correlated with LS incidence. This suggests that the evaluation of motor LS can be used as a tool for the early diagnosis and prevention of sarcopenia in cases of functional decline due to aging in the elderly population.

Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis

  • Paula Lambert;Sergio Augusto Quevedo Miguens Jr;Caroline Solda;Juliana Tomaz Sganzerla;Leandro Azambuja Reichert;Carlos Estrela;Fernando Branco Barletta
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.48.1-48.11
    • /
    • 2020
  • Objectives: This systematic review aimed to identify mean oxygen saturation values (SpO2) using pulse oximetry in permanent maxillary anterior teeth. Materials and Methods: The MEDLINE, Scientific Electronic Library Online, Cochrane Central Register of Controlled Trials, EMBASE, and Literatura Latino Americana em Ciências da Saúde electronic databases were searched. Combinations and variations of "oximetry" AND "dental pulp test" were used as search terms. Studies reporting means and standard deviations of SpO2 values were included. Two reviewers independently extracted data following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Heterogeneity was assessed using the I2 statistic, and all analyses were performed using R software. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool and the Newcastle-Ottawa scale. Results: Of the 251 studies identified, 19 met the eligibility criteria and were included (total sample, 4,541 teeth). In the meta-analysis, the mean SpO2 values were 84.94% (95% confidence interval [CI], 84.85%-85.04%) for the central incisors, 89.29% (95% CI, 89.22%-89.35%) for the lateral incisors, and 89.20% (95% CI, 89.05%-89.34%) for the canines. The studies were predominantly low-quality due to the high risk of bias associated with the index test, unclear risk regarding patient selection, and concerns about outcome assessment. Conclusions: Although most studies were low-quality, the oxygen saturation levels in normal pulp could be established (minimum saturation, 77.52%). Despite the risk of bias of the included studies, the reference values reported herein are clinically relevant for assessments of changes in pulp status.