• 제목/요약/키워드: Diagnostic Sensitivity

검색결과 1,247건 처리시간 0.031초

Diagnostic Value of Immunoglobulin G Anti-Deamidated Gliadin Peptide Antibody for Diagnosis of Pediatric Celiac Disease: A Study from Shiraz, Iran

  • Anbardar, Mohammad Hossein;Haghighi, Fatemeh Golbon;Honar, Naser;Zahmatkeshan, Mozhgan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제25권4호
    • /
    • pp.312-320
    • /
    • 2022
  • Purpose: Screening serologic tests are important tools for the diagnosis of celiac disease (CD). Immunoglobulin (Ig)G anti-deamidated gliadin peptide (anti-DGP) is a relatively new autoantibody thought to have good diagnostic accuracy, comparable to that of anti-tissue transglutaminase (anti-tTG) antibody. Methods: Pediatric patients (n=86) with a clinical suspicion of CD were included. Duodenal biopsy, anti-tTG, and IgG anti-DGP antibody tests were performed. The patients were divided into CD and control groups based on the pathological evaluation of duodenal biopsies. The diagnostic accuracy of serological tests was determined. Results: IgA anti-tTG and IgG anti-DGP antibodies were positive in 86.3% and 95.4% of patients, respectively. The sensitivity, specificity, and diagnostic accuracy of the IgA anti-tTG test were 86.3%, 50.0%, and 68.6%, respectively, and those of the IgG anti-DGP test were 95.4%, 85.7%, and 90.7%, respectively. The area under the receiver operating characteristic (ROC) curve was 0.84 (95% confidence interval [CI], 0.74-0.91) for IgA anti-tTG test and 0.93 (95% CI, 0.86-0.97) for IgG anti-DGP test. The comparison of IgA anti-tTG and IgG anti-DGP ROC curves showed a higher sensitivity and specificity of the IgG anti-DGP test. Conclusion: IgG anti-DGP is a reliable serological test for CD diagnosis in children. High tTG and DGP titers in the serum are suggestive of severe duodenal atrophy. The combined use of IgA anti-tTG and IgG anti-DGP tests for the initial screening of CD can improve diagnostic sensitivity.

The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis

  • Tae-Hyung Kim;Sungmin Woo;Sangwon Han;Chong Hyun Suh;Soleen Ghafoor;Hedvig Hricak;Hebert Alberto Vargas
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.684-694
    • /
    • 2020
  • Objective: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). Materials and Methods: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. Results: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. Conclusion: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2

  • Chiao-Hsu Ke;Mao-Yuan Du;Wang-Ju Hsieh;Chiu-Chiao Lin;James Mingjuh Ting;Ming-Tang Chiou;Chao-Nan Lin
    • Journal of Veterinary Science
    • /
    • 제25권2호
    • /
    • pp.28.1-28.11
    • /
    • 2024
  • Background: Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. Objectives: This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. Methods: We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. Results: The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. Conclusions: The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.

Aberrant Methylation of Genes in Sputum Samples as Diagnostic Biomarkers for Non-small Cell Lung Cancer: a Meta-analysis

  • Wang, Xu;Ling, Li;Su, Hong;Cheng, Jian;Jin, Liu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4467-4474
    • /
    • 2014
  • Background: We aimed to comprehensively review the evidence for using sputum DNA to detect non-small cell lung cancer (NSCLC). Materials and Methods: We searched PubMed, Science Direct, Web of Science, Chinese Biological Medicine (CBM), Chinese National Knowledge Infrastructure (CNKI), Wanfang, Vip Databases and Google Scholar from 2003 to 2013. The meta-analysis was carried out using a random-effect model with sensitivity, specificity, diagnostic odd ratios (DOR), summary receiver operating characteristic curves (ROC curves), area under the curve (AUC), and 95% confidence intervals (CI) as effect measurements. Results: There were twenty-two studies meeting the inclusion criteria for the meta-analysis. Combined sensitivity and specificity were 0.62 (95%CI: 0.59-0.65) and 0.73 (95%CI: 0.70-0.75), respectively. The DOR was 10.3 (95%CI: 5.88-18.1) and the AUC was 0.78. Conclusions: The overall accuracy of the test was currently not strong enough for the detection of NSCLC for clinical application. Dscovery and evaluation of additional biomarkers with improved sensitivity and specificity from studies rated high quality deserve further attention.

적외선 체온의 진단 정확도 평가 연구: 체계적 문헌고찰 (Reliability and Accuracy of Infrared Temperature: A Systematic Review)

  • 박성희
    • 성인간호학회지
    • /
    • 제26권6호
    • /
    • pp.668-680
    • /
    • 2014
  • Purpose: The aim of this study was to investigate the accuracy of infrared temperature measurements compared to axillary temperature in order to detect fever in patients. Methods: Studies published between 1946 and 2012 from periodicals indexed in Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected using the following key words: "infrared thermometer". QUADAS-II was utilized to assess the internal validity of the diagnostic studies. Selected studies were analyzed through a meta-analysis using MetaDisc 1.4. Results: Twenty-one diagnostic studies with high methodological quality were included representing 3,623 subjects in total. Results of the meta-analysis showed that the pooled sensitivity, specificity, and area under the curve (AUC) of infrared tympanic thermometers were 0.73 (95% CI 0.70~0.75), 0.92 (95% CI 0.91~0.92), and 0.90, respectively. For axillary temperature readings, the pooled sensitivity was 0.67 (95% CI 0.62~0.73), the pooled specificity was 0.87 (95% CI 0.85~0.90), and the AUC was 0.80. Conclusion: Infrared tympanic temperature can predict axillary temperature in normothermic and in febrile patients with an acceptable level of diagnostic accuracy. However, further research is necessary to substantiate this finding in patients with hyperthermia.

Meta-analysis of the Diagnostic Test Accuracy of Pediatric Inpatient Fall Risk Assessment Scales

  • Kim, Eun Joo;Lim, Ji Young;Kim, Geun Myun;Lee, Mi Kyung
    • Child Health Nursing Research
    • /
    • 제25권1호
    • /
    • pp.56-64
    • /
    • 2019
  • Purpose: This study was conducted to obtain data for the development of an effective fall risk assessment tool for pediatric inpatients through a systematic review and meta-analysis of the diagnostic test accuracy of existing scales. Methods: A literature search using Medline, Science Direct, CINAHL, EMBASE, and the Cochrane Library was performed between March 1 and 31, 2018. Of 890 identified papers, 10 were selected for review. Nine were used in the meta-analysis. Stata version 14.0 was used to create forest plots of sensitivity and specificity. A summary receiver operating characteristic curve was used to compare all diagnostic test accuracies. Results: Four studies used the Humpty Dumpty Falls Scale. The most common items included the patient's diagnoses, use of sedative medications, and mobility. The pooled sensitivity and specificity of the nine studies were .79 and .36, respectively. Conclusion: Considering the low specificity of the pediatric fall risk assessment scales currently available, there is a need to subdivide scoring categories and to minimize items that are evaluated using nurses' subjective judgment alone. Fall risk assessment scales should be incorporated into the electronic medical record system and an automated scoring system should be developed.

의학적 의사결정 도구들에 대한 고찰 : Bayesian analysis and ROC analysis (Medical decision making tools : Bayesian analysis and ROC analysis)

  • 이병도
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.1-5
    • /
    • 2006
  • During the diagnostic process of the various oral and maxillofacial lesions, we should consider the following: 'When should we order diagnostic tests? What tests should be ordered? How should we interpret the results clinically? And how should we use this frequently imperfect information to make optimal medical decisions?' For the clinicians to make proper judgement, several decision making tools are suggested. This article discusses the concept of the diagnostic accuracy (sensitivity and specificity values) with several decision making tools such as decision matrix, ROC analysis and Bayesian analysis. The article also explain the introductory concept of ORAD program.

  • PDF

형산강 유역 포항 통합시 근로자들에 있어서 간흡충 감염상 및 초음파검사와 피내반응검사의 정확도 (Evaluation of sonography and skin test in diagnosis of clonorchiasis at the Hyongsan-gang (River) area)

  • 이현경
    • Parasites, Hosts and Diseases
    • /
    • 제33권2호
    • /
    • pp.117-124
    • /
    • 1995
  • 간흡충증의 진단에 흔히 쓰이는 초음파검사의 민감도와 특이도를 알아보기 위하여 1994년 3월부터 11월까지 유행지역인 형산강 유역 포항 통합시 근로자 609명을 대상으로 피내반응검사. 대변검사. 초음파검사 및 설문조사를 시행하였다. 초음파검사에서 진단적인 소견으로 간내 담관의 확장만을 인정할 경우의 민감도는 21%이었고, 담관주위 에코가 있는 경우까지 포함하면 민감도는 52%이었다. 피내반응검사의 민감도는 62%이었다. 피내반응검사 양성이면서 초음파 소견이 하나라도 있는 경우를 진단기준으로 삼으면 민감도는 46%이었다 본 조사에서는 간흡충 혹은 간흡충의 집합체에 의해 생성되는 것으로 알려진 초음파검사상 방추상이고 약하게 반향을 보이는 담관이나 담낭내의 비음영의 초점이 뚜렷하게 보이는 환자는 없었다. 초음파검사의 특이도는 간내 담관의 확장만을 진단적 소견으로 인정할 경우 95%. 담관주의 에코까지 진단적 소견에 포함하면 83%이었다. 피내반응검사의 특이도는 52%이었다. 피내반응검사 양성이면서 초음파 소견이 하나 라도 있는 경우를 진단기준으로 삼으면 특이도는 90%이었다.

  • PDF

Comparison between Radiological and Invasive Diagnostic Modalities in Diagnosis of Breast Cancer

  • Onur, Gulcin Ozkan;Tarcan, Ercument;Onur, Asim;Can, Huseyin;Atahan, Murat Kemal;Yigit, Seyran Ceri;Cakalagaoglu, Fulya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권10호
    • /
    • pp.4323-4328
    • /
    • 2015
  • Background: Breast cancer is the most common cause of deaths of cancer in women. Nowadays, following completion of imaging methods, mainly fine needle aspiration biopsy (FNAB) and core biopsy methods have been used for establishing cytopathological diagnosis although discussions regarding superiority continue. Materials and Methods: Those with a complaint of "mass in breast" along with those diagnosed to have a mass as a result of routine physical examination among all patients applying to our clinic between 01.01.2009 and 31.12.2011 were retrospectively assessed. Totals of 146 and 64 patients with complete radiological observation who had undergone FNAB and core biopsies, respectively, were evaluated. Postoperative pathological results of patients of both groups receiving surgery were also taken into consideration. All results were compared in terms of false positivity/negativity, sensitivity/specifity, surgery types and distribution of postoperative results with regard to diagnoses along with those of malignant/benign masses with regard to quadrants determined. Results: Diagnostic malignancy power of mammographic BIRADS classification was 87.3%. However, the value was 75% in the core biopsy group. Sensitivity and specifity following comparison of FNAB and postoperative pathology results of those receiving surgery were 85.4% and 92.9% while they were 93.5% and 100% in the core biopsy group. Diagnostic malignancy power, calculated by determining AUC in ROC analysis, of FNAB was 89.1% while that of core biopsy was 96.7%. Conclusions: It was shown that core biopsy is superior to FNAB in terms of sensitivity, specificity and accurate histopathological classification. However; quick, cheap and basic diagnosis by means of FNAB should not be ignored. Sensitivity of FNAB is rather high in experienced hands and furthermore it would be expected to be lower than with core biopsy.

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.