• Title/Summary/Keyword: Diagnostic Pattern

Search Result 676, Processing Time 0.027 seconds

A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women (500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구)

  • Lee, In Seon;Jeon, Soo Hyung;Kang, Chang Wan;Kim, Jong Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.6
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.

A Study on Aadjustment of the Patterns, and the Correlation between the Diagnostic Tool for Climacteric and Postmenopausal Syndrome Pattern Identification (CaPSP) and Korean Medicine Doctors' Diagnosis (갱년기장애 및 폐경기 후 증후군 변증진단 도구의 변증분류 조정과 진단의 간의 진단일치도 연구)

  • Lee, In-Seon;Kim, Jong-Won;Jeon, Soo-Hyung;Chi, Gyoo-Yong;Kang, Chang-Wan
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.1
    • /
    • pp.1-14
    • /
    • 2021
  • Objectives: We studied for the adjustment of the patterns of 'The Diagnostic Tool for Climacteric and Postmenopausal Syndrome Pattern Identification (hereinafter CaPSPI)' (studyI) and the correlation between CaPSPI and Korean medicine doctors' diagnosis which was carried out without knowing the results of CaPSPI (studyII). Methods: The studyI followed the previous study method in 2018 (2018-3). The studyII was conducted from June 1, 2019 to July 10, 2020 with ◯◯ University Korean Medicine Hospital IRB's approval (2019-4). Doctors' diagnosis was conducted face-to-face with the subjects. Doctors' diagnosis was carried out based on the Kupperman's questionnaire, 'Diagnosis System of Oriental Medicine (hereinafter DSOM)' and four examinations (四診) records. The diagnosis was marked with 0 for 'no', 1 for 'somewhat', 2 for 'yes' and 3 for 'very yes'. The correlation between CaPSPI and the mean of doctors diagnostic scores were investigated statistically. Results: The studyI showed that heart-heat (心火) pattern was added. The Factor loading coefficient for heart-heat was 0.551 to 0.789, and the Cronbach's coefficient was 0.896. The studyII showed that the diagnosis (Kappa statistic) of two doctors showed statistically significant concordance (all eight patterns), with correlation of them were 0.3 or higher. And the correlation between the CaPSPI score and the mean of doctors' diagnostic score showed a statistically significant correlation, with liver qi depression (肝鬱) being the highest at 0.552 and dual deficiency of the heart-spleen (心脾兩虛) being the lowest at 0.301. Conclusions: Since the diagnosis results of CaPSPI showed a significant correlation with the diagnosis of Korean traditional medicine experts, it was believed that the CaPSPI results can be trusted and used for clinical purposes.

A Study on the Correlation between the Patterns of the Zone 2, 6 of Factor AA in 7-Zone-Diagnostic System and the Clinical Parameters (7구역진단기의 Factor AA 제2, 6구역 유형과 임상지표와의 상관성 연구)

  • Yu, Jung-Suk;Seol, Hyun;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.139-149
    • /
    • 2008
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 2, 6 of Factor AA in VEGA DFM 722(VEGA, Germany), 7-zone-diagnostic system and clinical parameters. The purpose of this study was relation Korean traditional medicine and western medicine with the data from 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made two groups according to the Factor AA patterns of VEGA DFM 722. The Factor AA pattern of Group A is that the red bar graph of zone 2 was higher than the normal range and the red bar graph of zone 6 was lower than the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 2 was lower than the normal range and the red bar graph of zone 6 was higher than the normal range. After the data from clinical parameters to correspond with conditions of each group were selected, the data from clinical parameters between each gropus analyzed statistically. Results and Conclusions : The values of Direct Bilirubin, GOT, BUN and BUN/Creatinine ratio of Group A were higher than them of Group B. The values of Sodium and Tyroxine of Group A were lower than them of Group B. These results mean that Group A has low energy but has increading tendency. To conclude, it is thought that the red bar graph of zone 2 is higher, the group is the more increasing and the red bar graph of zone 6 is lower, the group has the lower energy.

  • PDF

Diagnostic Test Pattern Generation for Combinational Circuits (조합회로에 대한 고장 진단 검사신호 생성)

  • Park, Young-Ho;Min, Hyoung-Bok;Lee, Jae-Hoon;Shin, Yong-Whan
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.9
    • /
    • pp.44-53
    • /
    • 1999
  • Generating diagnostic test patterns for combinational circuits remain to be a very difficult problem. For example, ISCAS85 c7552 benchmark circuit has 100 million fault pairs, Thus, we need more sophisticated algorithm to get more information. A new diagnostic algorithm for test pattern generation is suggested and implemented in this paper. DIATEST algorithm based on PODEM is also implemented for comparison to the new algorithm. These two algorithms have been applied to ISCAS85 benchmark circuits. Experimental results show that (1) both algorithms achieve fault pair coverage over 99%, (2) total test length of the new algorithm is much shorter than that of DIATEST, and (3) the new algorithm gives much more information used for making diagnostic dictionary, diagnostic decision tree or diagnostic test system despite DIATEST is faster than the new algorithm.

  • PDF

Hepatocellular carcinomas: correlation of enhancement degree with pathologic grades triple contrast MR imaging

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Woo-Jung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.108-108
    • /
    • 2001
  • Purpose: To correlate the histological differentiation of hepatocellular carcinomas (HCCs) with finding on triple contrast-enhanced MR imaging using gadolinium-chelates, superparamganetic ire oxides (SPIO), and mangafodipir trisodium. Method: Ten patients with proven HCC underwent triple contrast-enhanced MRI befo surgical resection. Subjective ratings of the enhancement pattern and degree were compare with the histological grades determined on surgical specimen. Quantitative measurements signal-to-noise ratio (S/N) of the lesion and the lesion-to-liver contrast-to-noise ratio C/N on the enhanced MR images, and the degree of S/N and C/N changes between the unenhanced and enhanced images were also correlated with the histological grades.

  • PDF

A study on the development of ADEX (ADEX 개발에 관한 연구)

  • Oh, Jae-Eung;Shin, Joon;Hahn, Chang-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.453-456
    • /
    • 1992
  • Diagnostic prototype expert system was developed by analyzing the measured acoustical data of automobile. For the utilities of this system, 1/3 octave filter(band-pass filter) and A/D converter were used for data acquisition and then information was analyzed using signal processing technique and pattern recognition by Hamming network algorithm. In order to raise the reliability of the diagnostic results, fuzzy inference technique was applied and, the results were displayed as graphical method to help the novice in diagnostic field. The validation of this diagnostic system was checked through experiments and it showed and acceptable performance for diagnostic process.

  • PDF

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

Frequency Analysis of Clinical Prescriptions in the Korean Medicine Hospital, Pusan National University based on Herb Weight Ratio(3) - Focusing on Back Pain and Nape Pain - (M54 코드 질환에 대한 부산대학교 한방병원의 본초 사용 내역 분석(3))

  • Lee, Byung-Wook
    • The Journal of Korean Medical History
    • /
    • v.28 no.1
    • /
    • pp.93-102
    • /
    • 2015
  • Objectives : The aim of this paper is finding the combinations of the medicinal herbs that are used frequently by analyzing the details of the herbal medicinal prescriptions used by the patients who were diagnosed with M54 code diseases. In addition, I will seek to assess the demonstrative pattern that frequently manifest in the M54 code disease patients by using the combinations of the medicinal herbs that are used frequently. Methods : After having extracted the prescription administered to the patients with the diagnostic code of M54, find the relevance with the demonstrative pattern by analyzing the combination for each of the medicinal herb effectiveness. Use the list of medicinal herbs utilized in the corresponding prescription to examine the most frequent combination of the medicinal herbs through the generation of up to 25 arbitrary combinations of the medicinal herbs. Results & Conclusions : As the results of the analysis of the details of the use of the prescribed herbal medicine packages by the Korean Medicine Hospital of Pusan National University, regarding the back pain of the diagnostic code M54, the prescriptions that corresponded to the kidney deficiency pattern, static blood pattern, wind pattern, dampness pattern, food accumulation pattern, qi depression pattern and phlegm-retained fluid pattern back pain among the back pain classifications under the Dongeuibogam (東醫寶鑑) were used frequently, and, regarding the Nape Pain, prescriptions that corresponded to the pain arising from the wind-dampness and phlegm the 'Taeyang meridian' was most frequent.

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Ultrasound Breast Elastographic Evaluation of Mass-Forming Ductal Carcinoma-in-situ with Histological Correlation - New Findings for a Toothpaste Sign

  • Leong, Lester Chee Hao;Sim, Llewellyn Shao-Jen;Jara-Lazaro, Ana Richelia;Tan, Puay Hoon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2673-2678
    • /
    • 2016
  • Background: It is unclear as to whether the size ratio elastographic technique is useful for assessing ultrasound-detected ductal carcinoma-in-situ (DCIS) masses since they commonly lack a significant desmoplastic reaction. The objectives of this study were to determine the accuracy of this elastographic technique in DCIS and examine if there was any histopathological correlation with the grey-scale strain patterns. Materials and Methods: Female patients referred to the radiology department for image-guided breast biopsy were prospectively evaluated by ultrasound elastography prior to biopsy. Histological diagnosis was the gold standard. An elastographic size ratio of more than 1.1 was considered malignant. Elastographic strain patterns were assessed for correlation with the DCIS histological architectural patterns and nuclear grade. Results: There were 30 DCIS cases. Elastographic sensitivity for detection of malignancy was 86.7% (26/30). 10/30 (33.3%) DCIS masses demonstrated predominantly white elastographic strain patterns while 20/30 (66.7%) were predominantly black. There were 3 (10.0%) DCIS masses that showed had a co-existent bull's-eye sign and 7 (23.3%) other masses had a co-existent toothpaste sign, a strain pattern that has never been reported in the literature. Four out of 4/5 comedo DCIS showed a predominantly white strain pattern (p=0.031) while 6/7 cases with the toothpaste sign were papillary DCIS (p=0.031). There was no relationship between the strain pattern and the DCIS nuclear grade. Conclusions: The size ratio elastographic technique was found to be very sensitive for ultrasound-detected DCIS masses. While the elastographic grey-scale strain pattern should not be used for diagnostic purposes, it correlated well with the DCIS architecture.