• Title/Summary/Keyword: Diagnostic DNA chip

Search Result 25, Processing Time 0.021 seconds

Automatic Reading System for On-off Type DNA Chip

  • Ryu, Mun-Ho;Kim, Jong-Dae;Kim, Jong-Won
    • Journal of Information Processing Systems
    • /
    • v.2 no.3 s.4
    • /
    • pp.189-193
    • /
    • 2006
  • In this study we propose an automatic reading system for diagnostic DNA chips. We define a general specification for an automatic reading system and propose a possible implementation method. The proposed system performs the whole reading process automatically without any user intervention, covering image acquisition, image analysis, and report generation. We applied the system for the automatic report generation of a commercialized DNA chip for cervical cancer detection. The fluorescence image of the hybridization result was acquired with a $GenePix^{TM}$ scanner using its library running in HTML pages. The processing of the acquired image and the report generation were executed by a component object module programmed with Microsoft Visual C++ 6.0. To generate the report document, we made an HWP 2002 document template with marker strings that were supposed to be searched and replaced with the corresponding information such as patient information and diagnosis results. The proposed system generates the report document by reading the template and changing the marker strings with the resultant contents. The system is expected to facilitate the usage of a diagnostic DNA chip for mass screening by the automation of a conventional manual reading process, shortening its processing time, and quantifying the reading criteria.

Optimization of a Diagnostic DNA Chip for Fish Rhabdovirus

  • Kim Young Ju;Kang Ji Hee;Kim Su Mi;Park Soo Il;Kim Sang Bong;Lee Myung Suk
    • Fisheries and Aquatic Sciences
    • /
    • v.8 no.3
    • /
    • pp.122-127
    • /
    • 2005
  • A DNA chip that rapidly and accurately detects the viral genes in rhabdovirus-infected fish was developed. The N, Ml, and G proteins of three rhabdovirus strains, infectious hematopoietic necrosis virus (IHNV), viral hemorrhagic septicemia virus (VHSV), and flounder rhabdovirus (HIRRV), were selected for use as probes. The sequences of the corresponding genes were obtained, and probes were prepared by PCR using specific primer sets. The specificity of the probes was confirmed by cross PCR. The prepared probes were spotted on poly-L-lysine- or aminosilane-coated glass slides and hybridized with target DNA under several different conditions in order to determine the optimal hybridization temperature, glass-slide coating, and target cDNA concentration.

Detection of Fish Rhabdoviruses using a Diagnostic Fish Rhabdovirus DNA Chip

  • Kim, Young-Ju;Lee, Myung-Suk
    • Fisheries and Aquatic Sciences
    • /
    • v.8 no.3
    • /
    • pp.185-187
    • /
    • 2005
  • We tested the in vivo ability of a DNA chip to detect virus-specific genes from virus-infected olive flounder Paralichthys olivaceus and rainbow trout Oncorhynchus mykiss. Target cDNA was obtained from total RNA of virus infected cell lines by reverse transcription (RT) and was labeled with fluorescent dye (Cy5-dUTP). The results show the successful detection of infectious hematopoietic necrosis virus (IHNV) and viral hemorrhagic septicaemia virus (VHSV) genes in the virus-infected fishes.

Recovery of Genes Epigenetically Altered by the Histone Deacetylase Inhibitor Scriptaid and Demethylating Agent 5-Azacytidine in Human Leukemia Cells

  • Park, Eun-Kyung;Jeon, Eun-Hyung;Kim, In-Ho;Park, Seon-Yang
    • Genomics & Informatics
    • /
    • v.8 no.4
    • /
    • pp.185-193
    • /
    • 2010
  • Histone deacetylation and demethylation are epigenetic mechanisms implicated in cancer. Studies regarding the role of modulation of gene expression utilizing the histone deacetylase inhibitor scriptaid and the demethylating agent 5-azacytidine in HL-60 leukemia cells have been limited. We studied the possibility of recovering epigenetically silenced genes by scriptaid and 5-azacytidine in human leukemia cells by DNA microarray analysis. The first group was leukemia cells that were cultured with 5-azacytidine. The second group was cultured with scriptaid. The other group was cultured with both agents. Two hundred seventy newly developed genes were expressed after the combination of 5-azacytidine and scriptaid. Twenty-nine genes were unchanged after the combination treatment of 5-azacytidine and scriptaid. Among the 270 genes, 13 genes were differed significantly from the control. HPGD, CPA3, CEACAM6, LOC653907, ETS1, RAB37, PMP22, FST, FOXC1, and CCL2 were up-regulated, and IGLL3, IGLL1, and ASS1 were down-regulated. Eleven genes associated with oncogenesis were found among the differentially expressed genes: ETS1, ASCL2, BTG2, BTG1, SLAMF6, CDKN2D, RRAS, RET, GIPC1, MAGEB, and RGL4. We report the results of our leukemia cell microarray profiles after epigenetic combination therapy with the hope that they are the starting point of selectively targeted epigenetic therapy.

SNP Detection Using DNA Chip (DNA칩을 이용한 SNP의 검출)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1319-1321
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip that has the above characteristic and be able to solve the problems. At first, we fabricated a high integration type DNA chip array by lithography technology. It is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic system.

  • PDF

Electrochemical Detection of Single Nucleotide Polymorphism (SNP) Using Microelectrode Array on a DNA Chip (미소전극어레이형 DNA칩을 이용한 유전자다형의 전기화학적 검출)

  • 최용성;권영수;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.286-292
    • /
    • 2004
  • In this study, an integrated microelectrode array was fabricated on glass slide using microfabrication technology. Probe DNAs consisting of mercaptohexyl moiety at their 5-end were spotted on the gold electrode using micropipette or DNA arrayer utilizing the affinity between gold and sulfur. Cyclic voltammetry in 5mM ferricyanide/ferrocyanide solution at 100 ㎷/s confirmed the immobilization of probe DNA on the gold electrodes. When several DNAs were detected electrochemically, there was a difference between target DNA and control DNA in the anodic peak current values. It was derived from specific binding of Hoechst 33258 to the double stranded DNA due to hybridization of target DNA. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic System.

DNAchip as a Tool for Clinical Diagnostics (진단의학 도구로서의 DNA칩)

  • 김철민;박희경
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.04a
    • /
    • pp.97-100
    • /
    • 2004
  • The identification of the DNA structure as a double-stranded helix consting of two nucleotide chain molecules was a milestone in modern molecular biology. The DNA chip technology is based on reverse hybridization that follows the principle of complementary binding of double-stranded DNA. DNA chip can be described as the deposition of defined nucleic acid sequences, probes, on a solid substrate to form a regular array of elements that are available for hybridization to complementary nucleic acids, targets. DNA chips based on cDNA clons, oligonucleotides and genomic clons have been developed for gene expression studies, genetic variation analysis and genomic changes associated with disease including cancers and genetic diseases. DNA chips for gene expression profiling can be used for functional analysis in human eel Is and animal models, disease-related gene studies, assessment of gene therapy, assessment of genetically modified food, and research for drug discovery. DNA chips for genetic variation detection can be used for the detection of mutations or chromosomal abnormalities in cnacers, drug resistances in cancer cells or pathogenic microbes, histocompatibility analysis for transplantation, individual identification for forensic medicine, and detection and discrimination of pathogenic microbes. The DNA chip will be generalized as a useful tool in clinical diagnostics in near future. Lab-on-a chip and informatics will facilitate the development of a variety of DNA chips for diagnostic purpose.

  • PDF

Human Papillomavirus Testing with Hybrid Capture II and DNA Chip

  • Im Jee-Aee;Shim Moon-Jung;Ryang Yong-Suk;Lee Duk-Chul
    • Biomedical Science Letters
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2005
  • The detection of high-risk human papilloma virus (HPV) allows us to predict the presence and future development of cervical intraepitheliallesion. In this study, we compared Hybrid Capture II and DNA chip methods for detection of HPV in cervical swab samples. And we evaluated the clinical efficacy and diagnostic performance of HPV DNA chip and Hybrid Capture II for detecting HPV in cervical neoplastic lesions. Seventy four patients were classified into three groups according to their histologic diagnosis: Group I (nonspecific chronic cervicitis), Group II (low-grade squamous intraepithelial lesion (SIL); koilocytosis, and mild dysplasia), and Group III (high-grade SIL;, moderate, severe dysplasia and in situ carcinoma). Cytologic diagnosis were based on the Bethesda System. Hybrid Capture II and DNA chip methods were performed to detect HPV. In 41 of the 74 cervical samples $(55.4\%)$, HPV DNAs were detected by Hybrid Capture II. In Group III, HPV-positive cases were detected in 15 $(20.3\%)$ of 74 patients by Hybrid Capture II. 25 patients with ASCUS cytology were histopathologically examined: 9 cases $(36\%)$ were Group II. In 18 patients with low-grade SIL cytology, 13 cases $(72.2\%)$ were Group II and 3 cases $(16.7\%)$ were Group III. 12 cases $(92.3\%)$ were Group ill of 13 patients with high-grade SIL cytology. The sensitivity of each test was $82\%$ in Hybrid Capture II and $53.9\%$ in DNA chip test. And the specificity was $74.3\%,\;85.7\%$ in Hybrid Capture II and DNA chip. In conclusion, Hybrid Capture II test is more sensitive than DNA chip in detecting women with cervical neoplastic lesions. Especially, in diagnosing of ASCUS, Hybrid Capture II test is more sensitive. Therefore, Hybrid Capture II test for cancer-associated HPV DNA is a viable option in the management of women with ASCUS.

  • PDF

Genomic Detection using Electrochemical Method (전기화학적 방법에 의한 유전자의 검출)

  • Choi, Yong-Sung;Lee, Kyung-Sup;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.6
    • /
    • pp.560-570
    • /
    • 2005
  • In this paper, a microelectrode away DNA chip was fabricated on glass slide using photolithography technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5' end were immobilized on the gold electrodes by DNA arrayer utilizing the affinity between gold and sulfu. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Cyclic voltammetry in 5mA ferricyanide/ferrocyanide solution at 100 mV/s confirmed the immobilization of probe DNA on the gold electrodes. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 concentrated at the electrode surface through association with formed hybrid. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic system.

Implementation of the Image Processing Algorithm for HPV DNA chip (HPV DNA 칩의 영상처리 알고리즘 구현)

  • 김종대;연석희;이용업;김종원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8C
    • /
    • pp.803-810
    • /
    • 2003
  • This paper addresses an image processing technique for the human papillomavirus (HPV) DNA chip to discriminate whether the probes are hybridized with the target DNA. HPV DNA chip is designed to determine HPV gene-types by using DNA probes for 22 HPV types. In addition to the probes, the HPV DNA chip has markers that always react with the sample DNA. The positions of probe-dots in the final scanned image are fixed relative to the marker- dot locations with a small variation attributable to the accuracy of the dotter and the scanner. The probes are quadruplicated to enhance diagnostic fidelity. frier knowledge including the marker relative distance and the replication information of probes is integrated into the template matching technique with normalized covariance measure. It was demonstrated that the employment of both of the prior knowledges can be accomplished by simply averaging the template matching measures over the positions of the markers and probes. The resulting proposed scheme yields stable marker locating and probe classification.