• Title/Summary/Keyword: Diagnostic Criteria

Search Result 933, Processing Time 0.024 seconds

Assessment of Tumor Response to Therapy in Lymphoma Using $^{18}F$-FDG PET: Diagnostic Performance of $^{18}F$-FDG PET and Interval Likelihood Ratio PET and Interval Likelihood Ratio ($^{18}F$-FDG PET을 이용한 림프종 치료 반응 평가: $^{18}F$-FDG PET의 진단 성능 특성과 구간 우도비)

  • Kim, Chang-Guhn;Kim, Dae-Weung;Park, Moo-Rim
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.369-385
    • /
    • 2009
  • In this paper, the authors intended to summarize briefly the features of lymphoma with regard to $^{18}F$-FDG PET for assessment of tumor response to therapy, to describe why assessment of treatment response should be performed, to review what method so far has been used in monitoring treatment response, to discuss what limitations of morphologic imaging criteria for assessing tumor response are, in compared with $^{18}F$-FDG PET, and to introduce recently proposed criteria for assessing tumor response in malignant lymphoma. And also the authors emphasize the need to understand the characteristics of diagnostic performance of $^{18}F$-FDG PET in several clinical settings in order to interpret $^{18}F$-FDG PET results appropriately, and to encourage the use of interval likelihood ratio to enhance clinical implications of test results which, in turns, allows referring physicians to understand the meaning of interpretation with easy. Until recently, treatment response has been assessed according to the morphologic criteria. Metabolic imaging with $^{18}F$-FDG PET was adopted to have important role for treatment assessment in IWC+PET criteria proposed recently by IHP. To accomplish this role, we should perform and interpret $^{18}F$-FDG PET according to IWC+PET criteria. It is important for referring physicians to understand the various limitations of $^{18}F$-FDG PET and pitfalls in PET interpretation, and to understand that clinical information are needed by nuclear medicine physicians to optimize the interpretation of $^{18}F$-FDG PET.

COMPARISON OF SEVERE EARLY CHILDHOOD CARIES PREVALENCES BY TWO DIAGNOSTIC CRITERIA (진단 기준에 따른 취학전 어린이의 중증 유아기 우식증 유병률 비교)

  • Lim, Kyoung-Uk;Lee, Kwang-Hee;Ra, Ji-Young;Lee,, Dong-Jin;An, So-Youn;Kim, Ji-Yeong;Song, Ji-Hyun;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.677-683
    • /
    • 2008
  • The purpose of study was to compare the prevalences of severe early childhood caries(S-ECC) using two different diagnostic criteria. The subjects of this study included 401 preschool children from 36 to 71 months of the randomly selected seven nurseries in Iksan city. Severe early childhood caries was defined as (1) 1 or more cavitated, missing (due to caries), or filled smooth surfaces in primary maxillary anterior teeth or (2) a decayed, missing, or filled score of ${\geq}$4 (age 3), ${\geq}$5 (age 4), or ${\geq}$6 (age 5) surfaces. The prevalence determined by maxillary anterior caries and the prevalence determined by dmfs were 26.7%, 28.9% in 3 years, 32.4%, 30.4% in 4 years, 39.4%, 41.3% in 5 years, and 35.4%, 35.9% in all, respectively. The results suggest that the two diagnostic criteria of the severe early childhood caries yield almost the same results.

  • PDF

Comparable Ablation Efficiency of 30 and 100 mCi of I-131 for Low to Intermediate Risk Thyroid Cancers Using Triple Negative Criteria

  • Fatima, Nosheen;Zaman, Maseeh uz;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1115-1118
    • /
    • 2016
  • Background: There is controversy about ablation efficacy of low or high doses of radioiodine-131 (RAI) in patients with differentiated thyroid cancers (DTC). The purpose of this prospective study was to determine efficacy of 30 mCi and 100 mCi of RAI to achieve successful ablation in patients with low to intermediate risk DTC. Materials and Methods: This prospective cross sectional study was conducted from April 2013 to November 2015. Inclusion criteria were patients of either gender, 18 years or older, having low to intermediate risk papillary and follicular thyroid cancers with T1-3, N0/N1/Nx but no evidence of distant metastasis. Thirty-nine patients were administered 30 mCi of RAI while 61 patients were given 100 mCi. Informed consent was acquired from all patients and counseling was done by nuclear physicians regarding benefits and possible side effects of RAI. After an average of 6 months (range 6-16 months; 2-3 weeks after thyroxin withdrawal), these patients were followed up for stimulated TSH, thyroglobulin (sTg) and thyroglobulin antibodies, ultrasound neck (U/S) and a diagnostic whole body iodine scan (WBIS) for ablation outcome. Successful ablation was concluded with stimulated Tg< 2ng/ml with negative antibodies, negative U/S and a negative diagnostic WBIS (triple negative criteria). ROC curve analysis was used to find diagnostic strength of baseline sTg to predict successful ablation. Results: Successful ablation based upon triple negative criteria was 56% in the low dose and 57% in the high dose group (non-significant difference). Based on a single criterion (follow-up sTg<2 ng/ml), values were 82% and 77% (again non-significant). The ROC curve revealed that a baseline sTg level ${\leq}7.4ng/ml$ had the highest diagnostic strength to predict successful ablation in all patients. Conclusions: We conclude that 30 mCi of RAI has similar ablation success to 100 mCi dose in patients with low to intermediate risk DTC. A baseline $sTg{\leq}7.4ng/ml$ is a strong predictor of successful ablation in all patients. Low dose RAI is safer, more cost effective and more convenient for patients and healthcare providers.

SonazoidTM versus SonoVue® for Diagnosing Hepatocellular Carcinoma Using Contrast-Enhanced Ultrasound in At-Risk Individuals: A Prospective, Single-Center, Intraindividual, Noninferiority Study

  • Hyo-Jin Kang;Jeong Min Lee;Jeong Hee Yoon;Jeongin Yoo;Yunhee Choi;Ijin Joo;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.23 no.11
    • /
    • pp.1067-1077
    • /
    • 2022
  • Objective: To determine whether Sonazoid-enhanced ultrasound (SZUS) was noninferior to SonoVue-enhanced ultrasound (SVUS) in diagnosing hepatocellular carcinoma (HCC) using the same diagnostic criteria. Materials and Methods: This prospective, single-center, noninferiority study (NCT04847726) enrolled 105 at-risk participants (71 male; mean age ± standard deviation, 63 ± 11 years; range, 26-86 years) with treatment-naïve solid hepatic nodules (≥ 1 cm). All participants underwent same-day SZUS (experimental method) and SVUS (control method) for one representative nodule per participant. Images were interpreted by three readers (the operator and two independent readers). All malignancies were diagnosed histopathologically, while the benignity of other lesions was confirmed by follow-up stability or pathology. The primary endpoint was per-lesion diagnostic accuracy for HCC pooled across three readers using the conventional contrast-enhanced ultrasound diagnostic criteria, including arterial phase hyperenhancement followed by mild (assessed within 2 minutes after contrast injection) and late (≥ 60 seconds with a delay of 5 minutes) washout. The noninferiority delta was -10%p. Furthermore, different time delays were compared as washout criteria in SZUS, including delays of 2, 5, and > 10 minutes. Results: A total of 105 lesions (HCCs [n = 61], non-HCC malignancies [n = 19], and benign [n = 25]) were evaluated. Using the 5-minutes washout criterion, per-lesion accuracy of SZUS pooled across the three readers (72.4%; 95% confidence interval [CI], 64.1%-79.3%) was noninferior to that of SVUS (71.4%; 95% CI, 63.1%-78.6%), meeting the statistical criterion for non-inferiority (difference of 0.95%p; 95% CI, -3.8%p-5.7%p). The arterial phase hyperenhancement combined with the 5-minutes washout criterion showed the same sensitivity as that of the > 10-minutes criterion (59.0% vs. 59.0%, p = 0.989), and the specificities were not significantly different (90.9% vs. 86.4%, p = 0.072). Conclusion: SZUS was noninferior to SVUS for diagnosing HCC in at-risk patients using the same diagnostic criteria. No significant improvement in HCC diagnosis was observed by extending the washout time delay from 5 to 10 minutes.

PROBABILISTIC APPROACH ON SEISMOGENIC POTENTIAL OF A FAULT

  • Chang, Chun-Joong
    • Nuclear Engineering and Technology
    • /
    • v.43 no.5
    • /
    • pp.437-446
    • /
    • 2011
  • Siting criteria for nuclear power plants require that faults be characterized as to their potential for generating earthquakes, or that the absence of the potential for these occurrences be demonstrated. Because the definition of active faults in Korea has been applied by the deterministic method, which depends on the numerical age of fault movement, the possibility of inherent uncertainties exists in determining the maximum earthquake from the fault sources for seismic design. In an attempt to overcome these problems this study suggests new criteria and a probabilistic quantitative diagnostic procedure that could estimate whether a fault is capable of generating earthquakes in the near future.

Comparison of Clinical and Psychological Characteristics between Self-Reported Bruxism and Clinically Detected Bruxism by Wear Facet on Splint

  • Shim, Young-Joo;Kang, Jin-Kyu;Lee, You-Mee;Lim, Hyun-Dae
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.4
    • /
    • pp.140-145
    • /
    • 2015
  • Purpose: Bruxism is commonly considered a major risk factor for temporomandibular disorders (TMD), and the psychosocial factors had been one of the etiologic factor of bruxism. But there are still unsolved issues on the relationship between sleep bruxism and TMD and the etiologic factors of bruxism. This study is aim to evaluate the clinical and psychosocial characteristics according to diagnostic grade of bruxism in TMD patients. Methods: Three hundred subjects were enrolled who were under the stabilization splint therapy for TMD. Recently international consensus proposed a diagnostic grading system of "possible", "probable", and "definite" sleep or awake bruxism for clinical and research purpose. According to their suggestion, we classified these subjects as self-reported bruxism (SRB) and wear facet bruxism (WFB). We investigated the clinical characteristics (sex, age, chief complaint, pain duration, visual analogue scale), sum of tenderness (temporomandibular joint, masticatory muscles, cervical muscles), diagnosis of TMD according to research diagnostic criteria (the Research Diagnostic Criteria for Temporomandibular Disorders, RDC/TMD), headache, subjective sleep quality (Pittsburgh Sleep Quality Index, PSQI), and psychosocial characteristics (Symptom Checklist-90-Revised, SCL-90-R) in enrolled subjects. We compared the clinical and psychosocial characteristics between these bruxism groups. Results: There were no significant correlation between self-reported and WFB (p=0.13). SRB subjects more reported pain as a chief complain than subject who did not report bruxism (p=0.014). The mean score of global PSQI was significantly higher in SRB than in did not report positively subjects (p=0.045). The mean score of anxiety and phobic anxiety was significantly higher in SRB than in did not reported positively subjects (p=0.045, p=0.041). Conclusions: Although bruxism is regarded as risk factor of TMD, this study showed inconsistent result between SRB and clinically detected bruxism by wear facet on slpint. We suggest that the clinician should consider with extreme caution when they assess SRB.

A Study on the Diagnostic Significance of Hepatoscintigram with Colloidal Gold in Parenchymal Liver Disease (간실질(肝實質) 병변(病變)에 대(對)한 간주사(肝走査) (Hepatoscintigram with $^{198}Au$ colloid)의 진단적(診斷的) 가치에 대한 고찰)

  • Shin, Dong-Ho;Lee, Min-Ho;Kim, Mok-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.63-72
    • /
    • 1982
  • Hepatoscintigram has been a useful diagnostic method for the liver diseases since 1953, but reasonable diagnostic criteria for parenchymal liver diseases are not yet accurately established. For the purpose of searching for more advanced diagnostic criteria for various types of live disease by the liver scan, a retrospective study was made of 272 cases who underwent both hepatoscintigram with 198 Au colloid and liver biopsy in Hanynag University Hospital from Jan., 1978 to Dec., 1981. The results were as follows: 1. Fuzzy margin (irregular indentation of the liver margin) in the hepatoscintigram was noted in 226 cases (97.79%). 2. Of 35 cases with fuzzy margin only, 28 cases (80%) revealed mild parenchymal liver disease, such as acute hepatitis or chronic persistent hepatitis by the liver biopsy. 3. Mottling change (209 cases) was always accompanied by fuzzy margin except only one case, and 31 cases (86.1%) of fuzzy and mottling cases (36 cases) showed mild parenchymal liver disease. 4. Configuration change (193 cases) was usually accompanied with other changes and espicially 104 cases had configuration change with fuzzy and mottling changes. 73 cases (88.44%) of 86 cases with severe configuration change revealed advanced parenchymal liver disease on biopsy. If liver scan showed mild configuration change, we could not decide the type of liver disease only liver scan, and so further studies are needed. 5. Splenic uptake was noted in 34 cases (40.48%) of 84 cases with advanced parenchymal liver disease, and the degree of splenic uptake was for the most part morderate or severe; whereas splenic uptake was noted in 18 cases (16.51%) of the mild parenchymal liver disease (109 cases), and the degree of splenic uptake was largely mild.

  • PDF

Diagnostic Criteria of T1-Weighted Imaging for Detecting Intraplaque Hemorrhage of Vertebrobasilar Artery Based on Simultaneous Non-Contrast Angiography and Intraplaque Hemorrhage Imaging

  • Lim, Sukjoon;Kim, Nam Hyeok;Kwak, Hyo Sung;Hwang, Seung Bae;Chung, Gyung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.323-331
    • /
    • 2021
  • Purpose: To investigate the diagnostic criteria of T1-weighted imaging (T1W) and time-of-flight (TOF) imaging for detecting intraplaque hemorrhage (IPH) of a vertebrobasilar artery (VBA) compared with simultaneous non-contrast angiography and intraplaque hemorrhage (SNAP) imaging. Materials and Methods: Eighty-seven patients with VBA atherosclerosis who underwent high resolution MR imaging for evaluation of VBA plaque were reviewed. The presence and location of VBA plaque and IPH on SNAP were determined. The signal intensity (SI) of the VBA plaque on T1W and TOF imaging was manually measured and the SI ratio against adjacent muscles was calculated. The receiver-operating characteristic (ROC) curve was used to compare the diagnostic accuracy for detecting VBA IPH. Results: Of 87 patients, 67 had IPH and 20 had no IPH on SNAP. The SI ratio between VBA IPH and temporalis muscle on T1W was significantly higher than that in the no-IPH group (235.9 ± 16.8 vs. 120.0 ± 5.1, P < 0.001). The SI ratio between IPH and temporalis muscle on TOF was also significantly higher than that in the no-IPH group (236.8 ± 13.3 vs. 112.8 ± 7.4, P < 0.001). Diagnostic efficacies of SI ratios on TOF and TIW were excellent (AUC: 0.976 on TOF and 0.964 on T1W; cutoff value: 136.7% for TOF imaging and 135.1% for T1W imaging). Conclusion: Compared with SNAP, cutoff levels of the SI ratio between VBA plaque and temporalis muscle on T1W and TOF imaging for detecting IPH were approximately 1.35 times.

Diagnostic Paper Chip for Reliable Quantitative Detection of Albumin using Retention Factor (체류 인자를 이용한, 알부민의 정량 분석용 종이 칩)

  • Jeong, Seong-Geun;Lee, Sang-Ho;Lee, Chang-Soo
    • KSBB Journal
    • /
    • v.28 no.4
    • /
    • pp.254-259
    • /
    • 2013
  • Herein we present a diagnostic paper chip that can quantitatively detect albumin without external electronic reader and dispensing apparatus. We fabricated a diagnostic paper chip device by printing wax barrier on the paper and wicking it with citrate buffer and tetrabromophenol blue to detect albumin in sample solution. The paper chip is so simple that we dropped a sample solution at sample pad and measure the ratio of two travel distances of the sample solvent and albumin under the name of retention factor. Our result confirmed that the retention factor was constant in the samples with same concentration of albumin and useful determinant for the measurement of albumin concentration. The paper chip is affordable and equipment-free, and close to ideal point-of-care test in accordance with the assured criteria, outlined by the World Health Organization. We assume that this diagnostic paper chip will expand the concept of colorimetric determination and provide a inexpensive diagnostic method to aging society and developing country.

Diagnostic System of Modeling Errors Generated from IGES CAD Data Exchange (IGES CAD 데이터의 교환에서 오류 진단 시스템)

  • Park, Sang-Ho;Park, Jong-Wook;Han, Soon-Heung;Choi, Young;Yang, Jung-Sam;Lee, Byung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.218-225
    • /
    • 2003
  • A diagnostic system has been developed which reports modeling errors generated when exchanging CAD data using IGES (Initial Graphics Exchange Specification) format. The system determines whether the CAD data contains errors. It also helps to define the criteria for determining the integrity and interoperability of CAD data with downstream applications of another CAD/CAM/CAE/PDM systems. The methodology of our algorithms is to analyze IGES model data by identifying errors and anomalies with respect to the diagnosis of geometry and topology. The GUI (Graphic User Interface) of the developed system helps users to input values and to visualize diagnostic results at real time.