• 제목/요약/키워드: Diagnostic Correlation

검색결과 789건 처리시간 0.031초

Hepatocellular carcinomas: correlation of enhancement degree with pathologic grades triple contrast MR imaging

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Woo-Jung
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.108-108
    • /
    • 2001
  • Purpose: To correlate the histological differentiation of hepatocellular carcinomas (HCCs) with finding on triple contrast-enhanced MR imaging using gadolinium-chelates, superparamganetic ire oxides (SPIO), and mangafodipir trisodium. Method: Ten patients with proven HCC underwent triple contrast-enhanced MRI befo surgical resection. Subjective ratings of the enhancement pattern and degree were compare with the histological grades determined on surgical specimen. Quantitative measurements signal-to-noise ratio (S/N) of the lesion and the lesion-to-liver contrast-to-noise ratio C/N on the enhanced MR images, and the degree of S/N and C/N changes between the unenhanced and enhanced images were also correlated with the histological grades.

  • PDF

변화하는 혈압의 영향을 받지 않는 동맥 벽의 강화도 측정 방법 제안 : 대동맥 확장지수 (A suggestion of Aortic wall Stiffness Evaluation Technique Independent on Changeable Blood Pressure : Aortic Distensibility Index)

  • 서지혜;최동호;오수경;;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.151-158
    • /
    • 2008
  • To evaluate aortic wall stiffness without influence of different background blood pressure, a new technique was developed and verified. At eight swine descending aortae, volume-pressure measurement was performed using custom-made system. Based on averaged pressure-volume curve, aortic distensibility index was formulated to evaluate aortic wall stiffness regardless of variable blood pressure and aortic size. The variability of aortic distensibility index by pressure change was compared with other parameters for wall stiffness evaluation. Subsequently, the aortic distensibility index was calculated at 100 contrast-enhanced EBCT data sets of normal volunteers in regular health screening program. The measured aortic distensibility index was compared with age, coronary calcium score, and aortic calcium score. Between 50 and 360 mmHg of blood pressure, the coefficient of variance of aortic distensibility index was 22.00% as comparing with 88.99% of classical compliance. Based on age, aortic distensibility index showed correlation coefficient of 0.55, whereas classical compliance showed 0.26. The correlation coefficient with modified aortic calcification was 0.43. Linear regression study revealed statistical significance of correlation coefficients. The aortic distensibility index, the method to evaluate aortic wall stiffness free from variable blood pressure and aortic size, was developed and verified with significant practical feasibility.

Performance Evaluation of Biozentech Malaria Scanner in Plasmodium knowlesi and P. falciparum as a New Diagnostic Tool

  • Firdaus, Egy Rahman;Park, Ji-Hoon;Muh, Fauzi;Lee, Seong-Kyun;Han, Jin-Hee;Lim, Chae-Seung;Na, Sung-Hun;Park, Won Sun;Park, Jeong-Hyun;Han, Eun-Taek
    • Parasites, Hosts and Diseases
    • /
    • 제59권2호
    • /
    • pp.113-119
    • /
    • 2021
  • The computer vision diagnostic approach currently generates several malaria diagnostic tools. It enhances the accessible and straightforward diagnostics that necessary for clinics and health centers in malaria-endemic areas. A new computer malaria diagnostics tool called the malaria scanner was used to investigate living malaria parasites with easy sample preparation, fast and user-friendly. The cultured Plasmodium parasites were used to confirm the sensitivity of this technique then compared to fluorescence-activated cell sorting (FACS) analysis and light microscopic examination. The measured percentage of parasitemia by the malaria scanner revealed higher precision than microscopy and was similar to FACS. The coefficients of variation of this technique were 1.2-6.7% for Plasmodium knowlesi and 0.3-4.8% for P. falciparum. It allowed determining parasitemia levels of 0.1% or higher, with coefficient of variation smaller than 10%. In terms of the precision range of parasitemia, both high and low ranges showed similar precision results. Pearson's correlation test was used to evaluate the correlation data coming from all methods. A strong correlation of measured parasitemia (r2=0.99, P<0.05) was observed between each method. The parasitemia analysis using this new diagnostic tool needs technical improvement, particularly in the differentiation of malaria species.

Applying the ACR Preliminary Diagnostic Criteria in the Diagnosis and Assessment of Fibromyalgia

  • Kim, So-Mi;Lee, Sang-Heon;Kim, Hae-Rim
    • The Korean Journal of Pain
    • /
    • 제25권3호
    • /
    • pp.173-182
    • /
    • 2012
  • Background: Fibromyalgia (FM) is characterized by chronic widespread pain with a low pain threshold. The aim of this study was to compare two criteria for the diagnosis and assessment of FM and to analyze the correlation and agreement between the 1990 and 2010 American College of Rheumatology (ACR) preliminary diagnostic criteria for FM. Methods: We studied 98 patients who had already been diagnosed as having FM using the 1990 criteria or 2010 preliminary criteria. Tender point examination, FM impact questionnaire (FIQ) and pain visual analog scale (VAS) were obtained. According to the preliminary criteria, FM was quantified as WPI (widespread pain index) and the SS scale (symptom severity) and the two criteria were compared. Results: Among 98 patients, 78.6% of the patients were diagnosed with the 1990 ACR criteria and 93.9% of the patients were diagnosed with the ACR preliminary diagnostic criteria, and there was also significant agreement between the two criteria (P < 0.01). There was a correlation with the WPI and the tender point, with the SS and the FIQ, and with the sum of the WPI and SS and the FIQ. Conclusions: The ACR preliminary diagnostic criteria for FM were in agreement with the 1990 ACR criteria during the disease course. The preliminary criteria were the more sensitive method than the 1990 criteria. In addition, the 2010 criteria might have advantages since it is easy to assess the physical and psychological symptoms and can be quantified. Therefore, the ACR preliminary diagnostic criteria for FM could be used more conveniently for clinical diagnosis and follow up evaluation after starting management of FM.

절연파괴시험법을 이용한 3.3[kV] 유도전동기의 절연물 열화특성 분석 (Analysis of Aging Insulation Characteristics of 3.3[kV] Class Induction Motor with AC Breakdown Test)

  • 이주;김현일;김윤현;손영규
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.141-149
    • /
    • 2007
  • 본 논문은 유도전동기 고정자권선의 절연물에 대하여 비파괴 및 파괴시험을 실시하여 절연물의 비파괴특성과 내전압강도와의 상호관계를 비교, 평가, 분석함으로써, 향후 전동기의 절연상태 평가시 수명 및 절연진단의 신뢰성을 도모하고자 제안하였다. 본 논문에서는 비파괴시험과 파괴시험과의 상관관계를 평가하기위하여 비파괴시험으로 절연저항시험, 성극지수시험, 유전정접시험, 부분방전시험을 실시하였으며, 파괴시험은 60[kV] AC 내전압를 이용하여 실시하였다. 또한 장기간 사용된 전동기 권선의 절연물에 대한 연구결과로부터 기존 선진국의 진단방법 및 판정기준이 국내에서 제작된 전동기에 대한 절연특성 평가 및 분석에도 타당함을 증명하였으며, 향후 본 논문에서 제시한 자료들은 유사조건의 산업현장에서 운용중인 유도전동기의 수명 및 상태 평가를 위한 기초자료로 유용하게 사용될 수 있으리라 기대된다.

기능성 소화불량 환자에서 설태후박 및 흉늑각 측정의 진단적 가치 (Diagnostic Values of Tongue Coating Thickness and Sterno-costal Angle in Functional Dyspepsia)

  • 손지영;김진성
    • 대한한방내과학회지
    • /
    • 제35권2호
    • /
    • pp.157-174
    • /
    • 2014
  • Objectives : The aims of this study were to evaluate the diagnostic values of tongue coating thickness and sterno-costal angle as the quantitative diagnostic indicators in functional dyspepsia. Methods : We surveyed 60 functional dyspepsia patients recruited by the clinical trial, 'Clinical Trial for Evaluation on Availability of tongue diagnosis system (CTS-1000) : a Pilot study'. The patients were classified into three groups according to Rome III criteria for functional dyspepsia, and categorized into five groups according to Instrument of pattern identification for functional dyspepsia. Nepean dyspepsia index-Korean version (NDI-K) score, tongue coating thickness (percentage of tongue coating by tongue diagnosis system (CTS-1000), and weight of tongue coating by microbalance), sterno-costal angle, duration of illness and body mass index (BMI) were investigated. Results : Among the 5 types by instrument of pattern identification for functional dyspepsia, a significant difference of percentage of tongue coating was found. Percentage of tongue coating and weight of tongue coating showed significant correlation with total NDI-K score. Sterno-costal angle showed strong positive correlation with BMI and also showed significant difference between the non-overweight (BMI<23, n=32) and overweight ($BMI{\geq}23$, n=28) groups. Conclusions : Tongue coating thickness showed its potential as a new quantitative diagnostic indicator of functional dyspepsia. Further studies on the sterno-costal angle are anticipated to evaluate its potential as a new quantitative diagnostic indicator.

유방 병변 256례의 세침흡인 세포학적 진단 및 조직학적 진단과의 비교연구 (Comparison of Fine Needle Aspiration Cytologic Diagnoses and Histologic Diagnoses in 256 Breast Lesions)

  • 강미선;정수진;윤혜경
    • 대한세포병리학회지
    • /
    • 제8권2호
    • /
    • pp.120-128
    • /
    • 1997
  • Fine needle aspiration cytology of breast lesion is well known as a simple, economic and effective diagnostic modality. For the evaluation of cytohistologic correlation, 256 cases of cytologic smears and subsequent histologic sections during 2-year period from Jan. 1995 to Dec. 1996 were reviewed. 1. Fifteen cases(5.9%) were proven as insufficient for evaluation, and 13 of them were fibrocystic change histologically. One case of carcinoma exhibiting sufficient amount of aspirates with no malignant cells on smear was regarded as inadequate. 2. Cytohistologic correlation of 240 cases revealed sensitivity 87.0%, specificity 100.0%, positive predictive value 100.0%, negative predictive value 97.0%, false positive rate 0.0% and false negative rate 13.0%. Total diagnostic accuracy is 95.7%. 3. Total 6 cases of negative were due to small amount of aspirates containing scantiness of malignant cells in two and underestimation in four. 4. Diagnostic concordance rates of fibrocystic change and fibroadenoma were 95.5% and 80.0%, respectively. Diagnostic discrepancies were noted in 7 cases of fibrocystic change and 6 cases of fibroadenoma, however, cytologic discrimination of two entities was not easy in seven of them. 5. In a case of phyllodes tumor and a case of duct ectasia, the discrepancy was due to targeting error. Other three cases(lymphoma, adenomyoepithelioma and granulomatous mastitis) were misinterpreted because of poor acquaintance with those entities. Diagnostic accuracy of fine needle aspiration cytology of breast lesions are relatively high. However, good technique on aspiration and adequate interpretation are necessary to reduce the false negative rate and the discrepancy between cytologic and histologic diagnoses.

  • PDF

Clinicopathological Significance and Diagnostic Accuracy of c-MET Expression by Immunohistochemistry in Gastric Cancer: A Meta-Analysis

  • Pyo, Jung-Soo;Kang, Guhyun;Cho, Hyunjin
    • Journal of Gastric Cancer
    • /
    • 제16권3호
    • /
    • pp.141-151
    • /
    • 2016
  • Purpose: The aim of the present study was to elucidate the clinicopathological significance and diagnostic accuracy of immunohistochemistry (IHC) for determining the mesenchymal epidermal transition (c-MET) expression in patients with gastric cancer (GC). Materials and Methods: The present meta-analysis investigated the correlation between c-MET expression as determined by IHC and the clinicopathological parameters in 8,395 GC patients from 37 studies that satisfied the eligibility criteria. In addition, a concordance analysis was performed between c-MET expression as determined by IHC and c-MET amplification, and the diagnostic test accuracy was reviewed. Results: The estimated rate of c-MET overexpression was 0.403 (95% confidence interval [CI], 0.327~0.484) and it was significantly correlated with male patients, poor differentiation, lymph node metastasis, higher TNM stage, and human epidermal growth factor receptor 2 (HER2) positivity in IHC analysis. There was a significant correlation between c-MET expression and worse overall survival rate (hazard ratio, 1.588; 95% CI, 1.266~1.992). The concordance rates between c-MET expression and c-MET amplification were 0.967 (95% CI, 0.916~0.987) and 0.270 (95% CI, 0.173~0.395) for cases with non-overexpressed and overexpressed c-MET, respectively. In the diagnostic test accuracy review, the pooled sensitivity and specificity were 0.56 (95% CI, 0.50~0.63) and 0.79 (95% CI, 0.77~0.81), respectively. Conclusions: The c-MET overexpression as determined by IHC was significantly correlated with aggressive tumor behavior and positive IHC status for HER2 in patients with GC. In addition, the c-MET expression status could be useful in the screening of c-MET amplification in patients with GC.

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.

Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging

  • Bo Ra Kwon;Jung Min Chang;Soo-Yeon Kim;Su Hyun Lee;Sung Ui Shin;Ann Yi;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1210-1219
    • /
    • 2020
  • Objective: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). Materials and Methods: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. Results: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). Conclusion: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.