• 제목/요약/키워드: Diagnostic Accuracy

검색결과 1,063건 처리시간 0.026초

히르슈슈프룽병의 진단법은 얼마나 신뢰할 만한가? (How Reliable Are Diagnostic Methods of Hirschsprung Disease?)

  • 김한바로;김대연;김성철;남궁정만;황지희
    • Advances in pediatric surgery
    • /
    • 제20권2호
    • /
    • pp.33-37
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the diagnostic accuracy of the non-invasive diagnostic methods and rectal suction biopsy for the detection of Hirschsprung disease (HD). Methods: We reviewed diagnostic methods and results retrospectively in patients who underwent anorectal manometry, barium enema and rectal suction biopsy for the diagnosis of HD at Asan Medical Center from January 2000 to December 2012. Results: There were 97 patients (59 neonates and 38 infants) in the study period. The overall accuracy of anorectal manometry for the diagnosis of HD was 71.1% and its sensitivity was 51.4% (48.1% in neonate and 62.5% in infant, respectively) and its overall specificity was 82.3% (81.3% in neonate and 83.3% in infant, respectively). The Overall accuracy of barium enema was 66.0% (72.8% in neonate and 55.3% in infant, respectively) and specificity of barium enema was 53.2% (56.3% in neonate and 50.0% in infant, respectively). These results were lower than those of anorectal manometry. The overall sensitivity of barium enema was 88.6% (92.6% in neonate and 75.0% in infant, respectively) and it was higher than the sensitivity of anorectal manometry. Histological studies confirmed HD in 35 patients, in one of whom the suction biopsy showed negative finding. Conclusion: Accuracy of non-invasive methods for diagnosis of HD in our study is lower than those in previous study, so we need to improve the quality of diagnostic tools in our hospital. We conclude that the rectal suction biopsy is the most accurate test for diagnosing HD, so the biopsy to confirm the diagnosis of the HD is very important.

Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

  • Kyung Hee Lee;Kun Young Lim;Young Joo Suh;Jin Hur;Dae Hee Han;Mi-Jin Kang;Ji Yung Choo;Cherry Kim;Jung Im Kim;Soon Ho Yoon;Woojoo Lee;Chang Min Park
    • Korean Journal of Radiology
    • /
    • 제20권8호
    • /
    • pp.1300-1310
    • /
    • 2019
  • Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions ≤ 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.

Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

  • Sawchuk, Dena;Currie, Kris;Vich, Manuel Lagravere;Palomo, Juan Martin;Flores-Mir, Carlos
    • 대한치과교정학회지
    • /
    • 제46권5호
    • /
    • pp.331-342
    • /
    • 2016
  • Objective: To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods: An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results: Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions: Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority.

Diagnostic Performance of On-Site Automatic Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve

  • Doyeon Hwang;Sang-Hyeon Park;Chang-Wook Nam;Joon-Hyung Doh;Hyun Kuk Kim;Yongcheol Kim;Eun Ju Chun;Bon-Kwon Koo
    • Korean Circulation Journal
    • /
    • 제54권7호
    • /
    • pp.382-394
    • /
    • 2024
  • Background and Objectives: Fractional flow reserve (FFR) is an invasive standard method to identify ischemia-causing coronary artery disease (CAD). With the advancement of technology, FFR can be noninvasively computed from coronary computed tomography angiography (CCTA). Recently, a novel simpler method has been developed to calculate onsite CCTA-derived FFR (CT-FFR) with a commercially available workstation. Methods: A total of 319 CAD patients who underwent CCTA, invasive coronary angiography, and FFR measurement were included. The primary outcome was the accuracy of CT-FFR for defining myocardial ischemia evaluated with an invasive FFR as a reference. The presence of ischemia was defined as FFR ≤0.80. Anatomical obstructive stenosis was defined as diameter stenosis on CCTA ≥50%, and the diagnostic performance of CT-FFR and CCTA stenosis for ischemia was compared. Results: Among participants (mean age 64.7±9.4 years, male 77.7%), mean FFR was 0.82±0.10, and 126 (39.5%) patients had an invasive FFR value of ≤0.80. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT-FFR were 80.6% (95% confidence interval [CI], 80.5-80.7%), 88.1% (95% CI, 82.4-93.7%), 75.6% (95% CI, 69.6-81.7%), 70.3% (95% CI, 63.1-77.4%), and 90.7% (95% CI, 86.2-95.2%), respectively. CT-FFR had higher diagnostic accuracy (80.6% vs. 59.1%, p<0.001) and discriminant ability (area under the curve from receiver operating characteristic curve 0.86 vs. 0.64, p<0.001), compared with anatomical obstructive stenosis on CCTA. Conclusions: This novel CT-FFR obtained from an on-site workstation demonstrated clinically acceptable diagnostic performance and provided better diagnostic accuracy and discriminant ability for identifying hemodynamically significant lesions than CCTA alone.

머신러닝을 이용한 에너지 선택적 유방촬영의 진단 정확도 향상에 관한 연구 (A Feasibility Study on the Improvement of Diagnostic Accuracy for Energy-selective Digital Mammography using Machine Learning)

  • 엄지수;이승완;김번영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.9-17
    • /
    • 2019
  • Although digital mammography is a representative method for breast cancer detection. It has a limitation in detecting and classifying breast tumor due to superimposed structures. Machine learning, which is a part of artificial intelligence fields, is a method for analysing a large amount of data using complex algorithms, recognizing patterns and making prediction. In this study, we proposed a technique to improve the diagnostic accuracy of energy-selective mammography by training data using the machine learning algorithm and using dual-energy measurements. A dual-energy images obtained from a photon-counting detector were used for the input data of machine learning algorithms, and we analyzed the accuracy of predicted tumor thickness for verifying the machine learning algorithms. The results showed that the classification accuracy of tumor thickness was above 95% and was improved with an increase of imput data. Therefore, we expect that the diagnostic accuracy of energy-selective mammography can be improved by using machine learning.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

Alternative accuracy for multiple ROC analysis

  • Hong, Chong Sun;Wu, Zhi Qiang
    • Journal of the Korean Data and Information Science Society
    • /
    • 제25권6호
    • /
    • pp.1521-1530
    • /
    • 2014
  • The ROC analysis is considered for multiple class diagnosis. There exist many criteria to find optimal thresholds and measure the accuracy of diagnostic tests for k dimensional ROC analysis. In this paper, we proposed a diagnostic accuracy measure called the correct classification simple rate, which is defined as the summation of true rates for each classification distribution and expressed as a function of summation of sequential true rates for two consecutive distributions. This measure does not weight accuracy across categories by the category prevalence and is comparable across populations for multiple class diagnosis. It is found that this accuracy measure does not only have a relationship with Kolmogorov - Smirnov statistics, but also can be represented as a linear function of some optimal threshold criteria. With these facts, the suggested measure could be applied to test for comparing multiple distributions.

Value of Contrast-Enhanced Ultrasonography in the Differential Diagnosis of Enlarged Lymph Nodes: a Meta-Analysis of Diagnostic Accuracy Studies

  • Jin, Ya;He, Yu-Shuang;Zhang, Ming-Ming;Parajuly, Shyam Sundar;Chen, Shuang;Zhao, Hai-Na;Peng, Yu-Lan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권6호
    • /
    • pp.2361-2368
    • /
    • 2015
  • Objective: To evaluate the diagnostic accuracy of contrast-enhanced ultrasonography (CEUS) in differentiating between benign and malignant enlarged lymph nodes using meta-analysis. Materials and Methods: Pubmed, Embase, SCI and Cochrane databases were searched for studies (up to September 1, 2014) reporting the diagnostic performance of CEUS in discriminating between benign and malignant lymph nodes. Inclusion criteria were: prospective study; histopathology as the reference standard; and sufficient data to construct $2{\times}2$ contingency tables. Methodological quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Patient clinical characteristics, sensitivity and specificity were extracted. The summary receiver operating characteristic curve was used to examine the accuracy of CEUS. A meta-analysis was performed to evaluate the clinical utility in identification of benign and malignant lymph nodes. Sensitivity analysis was performed after omitting outliers identified in a bivariate boxplot and publication bias was assessed with Egger testing. Results: The pooled sensitivity, specificity and AUROC were 0.92 (95%CI, 0.85-0.96), 0.91 (95%CI, 0.82-0.95) and 0.97 (95%CI, 0.95-0.98), respectively. After omitting 3 outlier studies, heterogeneity decreased. Sensitivity analysis demonstrated no disproportionate influences of individual studies. Publication bias was not significant. Conclusions: CEUS is a promising diagnostic modality in differentiating between benign and malignant lymph nodes and can potentially reduce unnecessary fine-needle aspiration biopsies of benign nodes.

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • 제29권6호
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

치아 우식증 진단시 필름 방사선사진상과 디지털 방사선영상의 비교:CCD, CMOS, PSP와 film (A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.1-5
    • /
    • 2004
  • Purpose: To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. Materials and Methods : 32 occlusal and 30 proximal tooth surfaces were radiographed under standardized conditions using 3 digital systems; CCD (CDX-2000HQ, Biomedysis Co., Seoul, Korea), CMOS (Schick, Schick Inc., Long Island, USA), PSP (Digora/sup (R)/FMX, Orion Co./Soredex, Helsinki, Finland) and I film system (Kodak Insight, Eastman Kodak, Rochester, USA). 5 observers examined the radiographs for occlusal and proximal caries using a 5-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (Az). Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. For occlusal caries, Kodak Insight film had an Az of 0.765, CCD one of 0.730, CMOS one of 0.742 and PSP one of 0.735. For proximal caries, Kodak Insight film had an Az of 0.833, CCD one of 0.832, CMOS one of 0.828 and PSP one of 0.868. No statistically significant difference was noted between any of the imaging modalities. Conclusion: CCD, CMOS, PSP and film performed equally well in the detection of occlusal and proximal dental caries. CCD, CMOS and PSP-based digital images provided a level of diagnostic performance comparable to Kodak Insight film.

  • PDF