• Title/Summary/Keyword: Diagnostic Accuracy

Search Result 1,063, Processing Time 0.027 seconds

Diagnostic value of Thyroglobulin Measurement with Fine-needle Aspiration Biopsy for Lymph Node Metastases in Patients with a History of Differentiated Thyroid Cancer

  • Zhang, Hai-Shan;Wang, Ren-Jie;Fu, Qing-Feng;Gao, Shi;Sun, Bu-Tong;Sun, Hui;Ma, Qing-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10905-10909
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the diagnostic value of FNA-Tg for detecting lymph node metastases in patients with a history of differentiated thyroid cancer (DTC). Materials and Methods: A total of 58 patients with DTC diagnosis and evidence of single or multiple suspicious cervical lymph nodes were assessed. All underwent total or near-total thyroidectomy with (35 cases) or without (23 cases) radioiodine (RAI) ablation, followed by thyroid stimulating hormone (TSH) suppression therapy. A total of 68 lymph nodes were examined by ultrasound-guided fine needle aspiration (US-FNA) for both cytological examination and FNA-Tg measurement. Serum Tg and anti-thyroglobulin antibody (TgAb) levels were also measured. Diagnostic performance including sensitivity, specificity, accuracy, positive (PPV) and negative predictive value (NPV) of FNAC and FNA-Tg were calculated and compared. The Spearman's rank correlation coefficient was used to estimate the relationship between FNA-Tg and serum TgAb. Results: The FNA-Tg levels were significantly higher with DTC metastatic lymph nodes (median 927.7 ng/mL, interquartile range 602.9 ng/mL) than non-metastatic lymph nodes (median 0.1 ng/mL, interquartile range 0.4 ng/mL) (p<0.01). Considering 1.0 ng/mL as a threshold value for FNA-Tg, the sensitivity, specificity, accuracy, PPV and NPV of FNA-Tg were 95.7%, 95.5%, 95.6%, 97.8% and 91.3%, respectively. The sensitivity and accuracy of the combination of FNAC and FNA-Tg were significantly higher than that of FNAC alone (p<0.05). The diagnostic performance of FNA-Tg was not significantly different between cases with or without RAI ablation, and the serum TgAb levels did not interfere with FNA-Tg measurements. Conclusions: Measurement of FNA-Tg is useful. The combination of FNAC and FNA-Tg is more sensitive and accurate for detecting lymph node metastases in patients with a history of DTC than FNAC alone. Serum TgAbs appear to be irrelevant for measurement of FNA-Tg.

Clinical Efficacy of the Ultrasonography in the Diagnosis of the Palpable Soft Tissue Masses (촉지되는 연부조직 종괴의 진단에서 초음파 검사의 유용성)

  • Park, Tae Soo;Kim, Hong Sik;Kim, Sungjun;Ryu, Jeong Ah
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.59-65
    • /
    • 2011
  • Purpose: To determine the clinical efficacy of the ultrasonography (US) for the diagnosis of the soft tissue masses comparing to the clinical diagnosis through the physical examination. Materials and Methods: 83 consecutive patients with palpable soft tissue masses were presented retrospectively. On the basis of the pathological diagnosis after the operation, the diagnostic accuracies were evaluated the cases diagnosed by history taking and physical examination, and the cases diagnosed by US before the operation. Results: The diagnostic accuracy of the cases using US was higher(86.7%) than that of the cases using physical examination and history taking. The accuracy of US of the epidermal inclusion cyst was 71.4%, ganglion cyst 85.7%, lipoma 88.6%, respectively. Accurate diagnosis were made 54 cases with 65.1% sensitivity in the cases diagnosed by history taking and physical examination. In this case, its accuracy of the ganglion cyst was 56.0%, and the lipoma was 67.9%. Conclusion: US is a useful diagnostic tool for the diagnosis of the palpable soft tissue masses before the operation.

  • PDF

Diagnostic Efficacy and Complications by Transthoracic Fine Needle Aspiration Biopsy of Localized Lung Lesions (국소성 폐결절에 대한 경피적 세침 흡인술의 진단적 유용성 및 합병증)

  • Seong, Nak-Cheon;Kim, Ki-Joong;Yoon, Ki-Heon;Yoo, Jee-Hong;Kang, Hong-Mo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.339-347
    • /
    • 1996
  • Background : Transthoracic fine needle aspiration and biopsy(TNAB) has become a frequently used technique in the investigation of the intrathoracic lesions because of its safety, reliability, and accuracy. Method : Data on 125 patients who underwent TNAB from 1990 through 1994 were studied to determine the diagnostic sensitivity, accuracy and complications of this procedure as related to lesion type and location. Results : 1. The over-all diagnostic sensitivity of TNAB was 61.6%(77 of 125 patients). 2. The diagnostic yields were as high as 89.9% for malignant lesions, but a specific diagnosis of benign lesions were obtained only in 30% of benign lung lesions. 3. The correlation between results of TNAB cytology and of final histology was as high as 88.2%. 4. Lung lesions that were greater than 3cm in size had a higher proportion of correct diagnosis(73.3%) as compared with lesions 3cm or less in size(38.1%). But there was no significant difference between the central and peripheral lung lesions. 5. There were no serious complications to TNAB. In 12.8% of the procedures a pneumothorax developed, indicating a chest tube in 1.6% of the procedures. In 2 cases, minimal hemoptysis developed which did not require treatment. Conclusion : In our experience, TNAB represents a minor and safe procedure, which permits a direct approach to localized malignant lung lesions with a high degree of accuracy.

  • PDF

Comparative Study of Diagnostic Accuracy Rate by Sasang Constitutions on Measurement Method of Body Shape (체형측정 방법에 따른 사상체질 진단정확률 비교 연구)

  • Kim, Jong-Won;Sul, Yu-Kyung;Choi, Jae-Jung;Kwon, Suk-Dong;Kim, Kyu-Kon;Lee, Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.338-346
    • /
    • 2007
  • For Objectivity development of the body shape that is an importance standard for the classification of sasang constitutional medicine diagnosis, We made a comparison between Automatic & Physical measuring. This study uses 2 attitude which lies down & standing. We measured the body of patients(Width 5 places and circumference 8 places) and analyzed the anthropometric data dividing into sex, age, BMI. 296 patients's data are used in the analysis.

A Study on the Mixed Jaw Lesions Associated with Teeth (치아와 관련되어 나타나는 악골의 혼합병소에 관한 연구)

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • Purpose : 1. Retrospectively evaluate the accuracy of tentative diagnosis or impression from the clinico-radio-graphic materials of jaw lesions which showed mixed lesions associated with teeth. 2. To observe the diagnostic importance of the calcified part of the lesions which appear as radiopaque areas. Materials and Methods: 14 cases of jaw lesions which showed mixed lesions associated with teeth were reviewed. These lesions were mostly diagnosed as adenomatoid odontogenic tumors (6 cases) or calcifying odontogenic cysts with (4 cases) or without odontomas (4 cases). The calcified elements of the lesions which demonstrated various sizes and patterns of radiopaque shadows resembled odontoid tissues in some cases but could not be defined in some other cases radiographically. Results : The final histopathologic diagnosis confirmed adenomatoid odontogenic tumors in 4 of the 6 cases. The remaining 2 cases turned out to be odontoma and ameloblastic fibroodontoma. The 4 cases of calcifying odontogenic cysts with odontomas were correct in 3 cases but remaining 1 case was just odontoma. The 4 cases of calcifying odontogenic cysts were proved to be odontogenic keratocyst, calcified peripheral fibroma, unicystic ameloblastoma and squamous cell carcinoma. Conclusion : The diagnostic accuracy of the adenomatoid odontogenic tumors and calcifying odontogenic cysts were high when the lesions show typical appearance. The calcifications which show radiopaque areas could be odontomas or dystrophic calficifations or remnants of bone fragments from resorption.

  • PDF

DIAGNOSTIC ACCURACY OF $^{18}F$-FDG IN NODAL NEGATIVE ORAL SQUAMOUS CELL CARCINOMA (구강암 환자에서 경부 임파절 평가에 대한 $^{18}F$-FDG PET(Fluorine 18-Labelled Deoxyglucose Positron Emission Tomography)의 유용성)

  • Choi, Eun-Joo;Kang, Sang-Hoon;Kim, Ki-Ho;Nam, Woong;Kim, Hyung-Jun;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.597-600
    • /
    • 2007
  • PET is one of the most widely used verification methods for evaluation of metastasis on the lymph nodes of the neck in oral cancer patients. The purpose of this study was to assess the correlation between PET findings and histopathologic findings in patients who had been diagnosed as squamous cell carcinoma and performed neck dissection. Thirty-four necks in 25 patients had been evaluated on pathologic lymph nodes and the data were compared with preoperative PET scan. The sensitivity of PET at the level of the neck was 72.7%, specificity was 60%, and accuracy was 79.2%. Since FDG-PET show high false-positive results, it should be used with other diagnostic tools for evaluation of lymph node metastasis.

A Comparison of the Interval Estimations for the Difference in Paired Areas under the ROC Curves (대응표본에서 AUC차이에 대한 신뢰구간 추정에 관한 고찰)

  • Kim, Hee-Young
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.2
    • /
    • pp.275-292
    • /
    • 2010
  • Receiver operating characteristic(ROC) curves can be used to assess the accuracy of tests measured on ordinal or continuous scales. The most commonly used measure for the overall diagnostic accuracy of diagnostic tests is the area under the ROC curve(AUC). When two ROC curves are constructed based on two tests performed on the same individuals, statistical analysis on differences between AUCs must take into account the correlated nature of the data. This article focuses on confidence interval estimation of the difference between paired AUCs. We compare nonparametric, maximum likelihood, bootstrap and generalized pivotal quantity methods, and conduct a monte carlo simulation to investigate the probability coverage and expected length of the four methods.

Evaluation of oral and maxillofacial swellings using ultrasonographic features

  • Abdelsalam, Tarek Abdallah;Amer, Maha Eshak;Mahrous, Ahmed;Abdelkader, Moustafa
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.201-208
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the characteristic features of oral and maxillofacial swellings that could be seen on ultrasonographic examinations. Materials and Methods: Fifty patients with oral and/or maxillofacial swellings were randomly selected, thorough case histories and clinical examinations were done, ultrasonographic examinations with Doppler imaging were performed, and the features of every group were studied. Finally, histopathological evaluations were performed to identify the final diagnosis, according to which patients were classified into 5 groups; group I: inflammatory/space infection and abscess swellings, group II: cystic swellings, group III: lymph node swellings, group IV: benign swellings, and group V: malignant neoplastic swellings. Results: A significant association (P<0.05), with a contingency coefficient of 0.88, was found between the histopathological and ultrasonographic diagnoses, with ultrasonography having a diagnostic accuracy of 89% in diagnosing maxillofacial swellings. The diagnostic accuracy of ultrasonography was 100% for lymph node and malignant swellings, followed by 98% for inflammatory and cystic swellings and 92% for benign swellings. The sensitivity of the ultrasonographic diagnosis was 100% for cystic, lymph node, and malignant swellings, followed by 91% for inflammatory swellings and 86% for benign swellings. Conclusion: Ultrasonographic features with Doppler imaging greatly aid in obtaining accurate diagnoses of oral and maxillofacial swellings. Ultrasonography is a recommended imaging tool for differentiating maxillofacial swellings and classifying them accurately.

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

Discovery to Human Disease Research: Proteo-Metabolomics Analysis

  • Minjoong Joo;Jeong-Hun Mok;Van-An Duong;Jong-Moon Park;Hookeun Lee
    • Mass Spectrometry Letters
    • /
    • v.15 no.2
    • /
    • pp.69 -78
    • /
    • 2024
  • The advancement of high-throughput omics technologies and systems biology is essential for understanding complex biological mechanisms and diseases. The integration of proteomics and metabolomics provides comprehensive insights into cellular functions and disease pathology, driven by developments in mass spectrometry (MS) technologies, including electrospray ionization (ESI). These advancements are crucial for interpreting biological systems effectively. However, integrating these technologies poses challenges. Compared to genomic, proteomics and metabolomics have limitations in throughput, and data integration. This review examines developments in MS equipped electrospray ionization (ESI), and their importance in the effective interpretation of biological mechanisms. The review also discusses developments in sample preparation, such as Simultaneous Metabolite, Protein, Lipid Extraction (SIMPLEX), analytical techniques, and data analysis, highlighting the application of these technologies in the study of cancer or Huntington's disease, underscoring the potential for personalized medicine and diagnostic accuracy. Efforts by the Clinical Proteomic Tumor Analysis Consortium (CPTAC) and integrative data analysis methods such as O2PLS and OnPLS extract statistical similarities between metabolomic and proteomic data. System modeling techniques that mathematically explain and predict system responses are also covered. This practical application also shows significant improvements in cancer research, diagnostic accuracy and therapeutic targeting for diseases like pancreatic ductal adenocarcinoma, non-small cell lung cancer, and Huntington's disease. These approaches enable researchers to develop standardized protocols, and interoperable software and databases, expanding multi-omics research application in clinical practice.