• Title/Summary/Keyword: Diagnostic Accuracy

Search Result 1,085, Processing Time 0.029 seconds

Evaluation of Conotruncal Anomalies by Electron Beam Tomography (Conotruncal 기형 평가에서 전자선 단층 촬영 (EBT)의 정확성)

  • 최병욱;박영환;최병인;최재영;김민정;유석종;이종균;설준희;이승규
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.290-300
    • /
    • 2000
  • Background: To evaluate the diagnostic accuracy of EBT(Electron Beam Tomography) in the diagnosis of conotruncal anomaly and to determine whether it can be used as a substitute for cardiac angiography. Material and Method: 20 patients(11M & 9F) with TOF(n=7, pulmonary atresia 2), DORV(n=7), complete TGV(n=4), & corrected TGV(n=2) were included. The age ranged from 7 days to 26 years(median 60 days). We analyzed the sequential chamber localization, the main surgical concenrn in each disease category (PA size, LVED volume and coronary artery pattern for TOF & pulmonary atresia, the LV mass, LVOT obstruction, coronary artery pattern for complete TGV, and type of VSD and TV-PV distance for DORV, etc) and other associated anomalies(e.g., VSD, arch anomalies, tracheal stenosis, etc). Those were compared with the results of echocardiography(n=19), angiography (n=9), and surgery(n=11). The interval between EBT and echocardiography/angiography was within 20/11 days, respectively except for an angiography in a patient with corrected TGV (48 days). Result: EBT correctly diagnosed the basic components of conotruncal anomalies in all subjects, compared to echocardiography, angiography or surgery. These included the presence, type and size of VSD(n=20), pulmonic/LV outflow tract stenosis(n=15/2), relation of great arteries and the pattern of the proximal epicardial coronary arteries(16 out of 20). EBT proved to be accurate in quantitation of the intrapericardial and hilar pulmonary arterial dimension and showed high correlation and no difference compared with echocardiography, angiography, or surgery(p>0.05) except for left pulmonary arterial & ascending arterial dimension by echocardiography. LVED volume in seven TOF(no difference: p>0.05 & high correlation: r=0.996 with echocardiography), and LV mass in 4 complete TGV were obtained. Additionally, EBT enabled the cdiagnosis of subjlottic tracheal stenosis and tracheal bronchus in 1 respectively. Some peripheral PA stenosis were not detected by echocardiography, while echocardiography appeared to be slightly more accurate than EBT in detecing ASD or PDA. Conclusion: EBT can be a non-invasive and accurate modality of for the evaluation of most anatomical alteration including peripheral PS or interruption in patients with conotruncal anomalies. Combined with echocardiography, EBT study provides sufficient information for the palliative or total repair of anomalies.

  • PDF

The Value of Tc-99m DTPA Diuretic Renography for Assessment of Dilated Upper Urinary Tract in Children (소아의 상부 요관확장증에서 폐쇄 유무 감별에 있어 Tc-99m DTPA 이뇨 신장 신티그램의 유용성)

  • Yang, Ki-Ra;Lim, Gye-Yeon;Sohn, Hyung-Sun;Hahn, Seong-Tae;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.57-64
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the accuracy of Tc-99m DTPA diuretic renal scans in children with dilated upper urinary tract. Materials and Methods: We reviewed diuretic renal scans of 14 pediatric patients (age range: 3 days to 4 years) with unilateral hydronephrosis diagnosed by ultrasonography. Diuretic renal scan was done using Tc-99m DTPA and standardized protocol. In 3 neonates, diuretic renal scans were performed within 1 week and 3-7 months after birth. Results: Six patients required Pyeloplasty and eight were managed conservatively. All 6 patients requiring Pyeloplasty were diagnosed as having ureteropelvic junction obstruction in the diuretic renal scan. In these 6 patients, post-operative renal scans at 3-12 months after surgery were converted to nonobstructive pattern in 5 and a nonfunctioning pattern in 1. In 3 patients who underwent diuretic renal scan within 1 week after birth, nonobstructive patterns of initial scan were converted to obstructive patterns in the follow-up scan. However, all patients with nonobstructive diuretic renal scans performed after the neonatal period did well on serial ultrasonography and showed favorable clinical outcome without progression to obstruction. Conclusion: Tc-99m DTPA diuretic renal scan with standardized protocol is useful in assessing suspected ureteropelvic junction obstruction in children as an initial diagnostic or post-operative follow-up modality. Nonobstructive or indeterminate scan results in the neonatal period requires follow-up scan to monitor development of the obstructive pattern.

  • PDF

Role of PET in Evaluating Indeterminate Solitary Pulmonary Nodule with CT (CT상 악성여부가 불명확한 단일 폐결절에서의 양전자방출단층촬영술의 유용성)

  • Yoon, Seok-Boo;Choi, Joon-Young;Kim, Sun-Jung;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Sang-Eun;Kwon, O-Jung;Lee, Kyung-Soo;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.83-89
    • /
    • 1997
  • About one-third of radiologically indeterminate solitary pulmonary nodules (SPN) are eventually turned out to be malignant. It is very important to noninvasively determine whether the SPN is malignant or not for the decision of its way of management. PET imaging is highlighted by its unique ability of imaging the function and metabolism of cells. Glucose metabolism is increased in malignant transformed cells. We peformed FDG-PET studies in patients who had radiologically indeterminate SPN and compared the findings with histologic diagnoses to assess the diagnostic accuracy in the detection of malignancy and to decide which parameter is the most suitable for clinical practice among peak SUV (pSUV), average SUV (aSUV), 50/10 ratio, and time-activity curve (TAC), Thirty patients were included in this study and the most useful parameter was pSUV. The sensitivity and specificity in the detection of malignant SPN using 3.5 as a cut off pSUV were both 87%. Interestingly, all 2 false-negative cases were bronch-ioloalveolar carcinoma on histologic examination. If these cases, which could be strongly suspected by CT findings, were excluded, the sensitivity of pSUV was 100%. In conclusion, PET imaging is very helpful for determining malignancy in indeterminate SPN and pSUV is a conveniently measurable parameter which is valuable for interpretation.

  • PDF

Performance of Gated Myocardial Perfusion SPECT to Diagnose Coronary Artery Disease (게이트 심근 관류 SPECT의 관상 동맥 질환 진단 성능)

  • Kang, Won-Jun;Lee, Myoung-Mook;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.50-56
    • /
    • 1997
  • Gated SPECT can evaluate the regional wall motion of the heart. We evaluated the regional wall motion of the perfusion abnormality in conventional perfusion SPECT with gated SPECT. In case of suspicious perfusion abnormalities, we tried to differentiate the artifact from true abnormality in coronary vascular disease using gated SPECT. We thought that artifacts would have normal wall motion, whereas fixed defects with decreased wall motion would probably represent coronary artery disease. A total of 275 patients who were performed coronary angiography and T1-201 rest/Tc-99m MIBI dipyridamole stress gated SPECT within 2 months were enrolled. In coronary angiography, stenosis more than 50% was considered as coronary artery disease. After injection of 111MBq T1-201 rest image was obtained on triple head SPECT system. 370MBg Tc-99m MIBI was used for the stress image. Eight-frame per-cardiac-cycle gated Tc-99m SPECT studies were done. All the images were analyzed visually. Using perfusion SPECT, the overall sensitivity and specificity were 87% and 55% respectively. Regarding artery territory, sensitivity and specificity were 68% and 73% for left anterior descending artery(LAD), 62% and 78% for right coronary artery(RCA), 42% and 90% for left ciramflex artery(LCX). Using gated SPECT, the overall sensitivity and specificity were 87% and 66% respectively. Sensitivity and specificity were 68% and 78% for LAD, 62% and 79% for RCA, 42% and 90% for LCX. Among 21 false positive cases in perfusion SPECT, 5 cases were interpreted as true negative with gated SPECT. We conclude that gated SPECT provides a valuable adjunct to perfusion SPECT in characterizing perfusion abnormalities and to improve specificity.

  • PDF

The Role of Single-contrast CT for Management in Hemodynamically Stable Anterior Abdominal Stab wound Patients (혈역학적으로 안정된 복부 전벽 자상 환자의 개복 수술 결정에서 Single-contrast CT의 역할)

  • Jo, Janghwan;Kim, Joongsuck;Kim, Yeongcheol;Chung, Ilyong;Park, Jongmin;Ahn, Eunjung;Kim, Eunyoung;Park, Seihyeog;Kim, Seongyup
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.145-150
    • /
    • 2014
  • Purpose: To assess the accuracy and role of single-contrast computed tomography (CT) in the management of anterior abdominal stab wound (AASW). Methods: During 8-years period, single-contrast CT was performed in 21 hemodynamically stable AASW patients (age range, 22-64 years; median age, 45 years), including 19 men and 2 women. CT scans were evaluated by one trauma surgeon and one senior resident to determine the depth of injury(peritoneal violation or not), and abnormal findings of intraperitoneal cavity associated with stab injury. We retrospectively reviewed medical records regarding operative findings. Results: Nine patients underwent abdominal surgery and 12 patients nonoperative management. In the abdominal surgery group, abnormal CT findings included peritoneal violation in 14 patients and abnormal intraperitoneal cavity findings in 5 patients. There was no statistical significant difference regarding abnormal CT findings between abdominal surgery group and nonoperative management group. Among the nine abdominal surgery patients, therapeutic laparotomy was performed on 4 patients. The positive predictive value (PPV) and negative predictive value (NPV) of peritoneal violation to predictive therapeutic laparotomy were 28.6% and 100%, respectively. In addition, the PPV and NPV of abnormal intraperitoneal cavity CT findings to predict therapeutic laparotomy were 40.0% and 87.5%, respectively. There was no statistical significant difference regarding the abnormal CT findings between therapeutic laparotomy group and non therapeutic laparotomy group. Conclusion: CT is a good adjunctive method to evaluate hemodynamicaly stable AASW patients. If peritoneal violation is not seen on CT scan, conservative treatment on local wound may be safely performed without additional abdominal surgery. However, further study is warranted to evaluate the exact role of CT in the diagnostic workup of AASW patients.

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

Comparison of Diagnostic Accuracy for Detecting Coronary Artery Disease of Dipyridamole $^{99m}Tc$-MIBI Myocardial SPECT and It's Defect Map between Men and Women (디피리다몰 부하 $^{99m}Tc$-MIBI 심근 SPECT 극성결손지도를 이용한 관동맥질환 진단의 남녀 비교)

  • Bae, Sang-Kyun;Lee, Dong-Soo;Oh, Byung-Hee;Chung, June-Key;Lee, Myoung-Mook;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.59-64
    • /
    • 1993
  • To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole $^{99m}Tc$-MIBI myocardial SPECT, we obtained $^{99m}Tc$-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole $^{99m}Tc$-MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex (LCX) and 8% for right coronary artery (RCA) territories. Lesions${\geqq}$50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns): specificity was 84.6% in men and 67.9% in women (P < 0.025). For individual coronary artery, the sensitivity in men and women was 87.7%, 81.8% for LAD; 78%, 83.3% for RCA and 52.2%, 46.7% for LCX (P=ns): the specificity was 80%, 40% for LAD (P<0.01), 82.5%, 68.4% for RCA, 88.9%, 86.4% for LCX (P=ns). The hemodynamic parameter after intravenous dipyridamole in men and women were significantly changed; the heart rate was increased and systolic, diastolic blood pressure was decreased. Adverse effects were reported in 58.8% of men and 72.7% in women (P=ns). The incidence of chest pain and headache were higher in women. There was no significant difference in the incidences of nausea, abdominal pain, dizziness, facial flushing, dyspnea. In conclusion, dipyridamole $^{99m}Tc$-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  • PDF

Usefulness of FDG-PET/CT as a Diagnostic Tool for Routine Post Therapy Evaluation in Endometrial Cancer (자궁내막암의 치료 후 루틴 추적검사 방법으로서 FDG-PET/CT의 유용성)

  • Lee, Shin-Jae;Jeon, Tae-Joo;Kim, Seung-Jo;Kim, Hee-Jin;An, Hee-Jung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.301-308
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the usefulness of FDG-PET/CT as follow up imaging tool in patients with endometrial cancer after therapy. Material and Methods: One hundred one patients with endometrial cancer who underwent FDG PET/CT after the treatment of this disease were included in this study population (25-79 yr old, Mean age 50.6 yr old) and all these patients also performed various laboratory and imaging studies such as serum tumor marker, CT or MRI. The lesions having increased focal FDG uptake were classified into benign, equivocal, and malignant one according to their pattern and activity. Tumor recurrence was confirmed by histopathological results and other clinical and imaging data. Results: Among the 19 patients with 30 malignant or equivocal hot uptakes, 11 of 14 patients supposed to be malignant finding in PET/CT were proved to be tumor recurrence, while one of 5 patients with equivocal lesions were recurred malignancy, Two false negative cases were turned out to be peritoneal carcinomatosis, Estimated sensitivity, specificity and accuracy of PET/CT for diagnosis of recurrence in endometrial carcinoma after treatment were 86 %, 92 % and 91 %, respectively. Positive and negative predictive values in the same issue were 63% and 98%, respectively. Conclusion: FDG-PET/CT is useful for regular work up of endometrial carcinoma after the treatment because of its high negative predictive value as well as high sensitivity and specificity.

Comparison of the Results of Multistix$^{(R)}$SG and Comber-9-Test$^{(R)}$ RL Urine Dipstick Assay (Multistix$^{(R)}$-SG와 Comgur-9-test$^{(R)}$RL에 의한 요시험지봉검사 성적의 비교)

  • Kim, Dae-Chul;Kim, Kyung-Dong;Jung, Bo-Chan;Kim, Chung-Sook;Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.42-52
    • /
    • 1991
  • Two types of urine dipstick assays, Multistix-SG and Combur-9-test RL, were compared for compatibility, accuracy, specificity and predictive values of a positive and negative test in 501 patients urine and artificially prepared specimen. We found that the results of semiquantitative tests of Multistix-SG and Combur-9-Test RL performed were statistically similar in patients specimen. The urinary leukocyte estrase tests of Combur-9-Test RL assays compared with urine sediment microscopy in regard to compatibility, sensitivity, specificity, and predictive values of a positive and negative test 83.7%, 48.1%, 90.3%, 47.4% and 90.1%, respectively. The urinar nitrite tests of Comber-9-Test RL assays compared with urine culture tests, in regard to compatibility, sensitivity, specificity, and predictive values of a positive and negative tests were 90.3%, 19.4%, 84.7%, 53.8% and 94.1%, respectively. For the urinary protein, the sulfosalicylic acid method was the most sensitive test for any kinds of protein, and Multistix-SG appeared more sensitive than Compur-9-Test RL for the albuminuria. For the urinary bilirubin and glusose, two dipstick assays were similar in their diganostic efficiency. Finally in the urinary occult blood tests, Combur-9-Test RL assays was more sensitive than Multistix-SG.

  • PDF

Clinical Experience of 3T Breast MRI in Detecting the Additional Lesions in Breast Cancer Patients (유방암 환자에서 추가 병변 평가를 위한 3 테슬러 유방자기공명영상의 임상적 경험)

  • Lee, Ji-Hye;Kim, Sung-Hun;Kang, Bong-Joo;Choi, Jae-Jeong;Lee, Ah-Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.121-125
    • /
    • 2010
  • Purpose : The purpose of this study was to evaluate the diagnostic accuracy of 3.0-T breast MRI for detecting additional breast cancer soon after the initial diagnosis of breast cancer. Materials and Methods : From March to June 2009, 101 patients recently diagnosed breast cancer underwent breast MRI and surgery. Parameters analyzed on MRI were total extent of tumor, suspicious findings of multifocal, multicentric, or contralateral cancer. The diagnosis of MRI-detected cancer was confirmed by means of biopsy or surgical specimen evaluation after the localization. Results : MRI showed 37 additional suspicious findings in 34 patients. Twenty nine findings were true-positive (29/37, 78.4%), including 16 cases of multifocality, 11 cases of multicentricity and 2 cases of contralateral cancer. Among these cancers, 13 (44.8%) were ductal carcinoma in situ (DCIS) and 16 (55.1%) were infiltrating cancer. Eight findings were false-positive (8/37, 21.6%) including 6 cases of benign disease and 2 cases of high-risk lesions. Conclusion : In women with recently diagnosed breast cancer, 3.0-T MR imaging showed additional suspicious findings in 33.7%. The sensitivity and specificity for detecting additional breast cancer was 100% and 89.3%, respectively.