  • At the department of prosthodontics, the elderly patients with severely atrophied alveolar ridge who have been wearing complete dentures for a long period frequently visit the clinic. In general, the open-mouth impression technique for manufacturing a mandibular complete denture to secure primary support on buccal shelf area has been prevalent. In addition, for securing retention and stability of mandibular denture, we should consider diagnosis, oral function, denture border, occlusal plane, teeth arrangement, and patient training, etc.. But in edentulous patients with severe alveolar bone atrophy, it may hardly secure retention and stability of mandibular complete denture. To promote these, some of clinicians are making an attempt manufacturing the mandibular complete dentures using closed-mouth impression technique based on several reports that compare various impression techniques including open-mouth and closed-mouth impression technique. This case report suggests closed-mouth impression technique may promote retention and stability of mandibular complete denture and compares between the two impression techniques clinically.

Clinical characteristics of sleep bruxism patients with idiopathic facial pain (특발성 안면 통증 환자에서 수면 이갈이의 임상적 특징)

  • Myung, Yangho;Seo, Jeong-Il;Kim, Bok Eum;Kim, Young Gun;Kim, Seong Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Purpose: To profile various clinical characteristics of sleep bruxism (SB) patients with idiopathic facial pain (IFP) in the orofacial region. Materials and Methods: We analyzed 28 SB patients among 210 patients with IFP complaints. The profiles were evaluated using patient charts including gender, age, pain duration, pain location, pain intensity and affected areas by pain. Results: SB with IFP occurred more often in females (85.7%) than males (14.3%). The mean age at presentation was 48.9 years. The most common IFP sites of SB patients were the right maxilla (28.6%) and the right mandible (25.0%). The pain complaints occurred mostly in 2 teeth or areas (50.0%), followed by 1 area (28.6%) and then in ≥ 3 teeth or areas (21.4%). The mean pain intensity was 5.9 on a visual analogue scale from 0 to 10. The pain was spontaneous in 20 patients (71.4%), and the mean pain duration was 24.4 months. Conclusion: Identification of clinical characteristics of SB patients with IFP could be useful in the diagnosis of various IFP patients and beneficial in decreasing unnecessary care to reduce IFP. Further studies with larger number of subjects and extended duration are required for more systemized diagnostic methods and development of future treatment guidelines.

Quality Control of Dose Calibrator using 3D Printery (3D 프린터를 이용한 Dose Calibrator의 품질관리)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.307-312
    • /
    • 2021
  • In nuclear medicine, radioactive isotope tracers are administered to the human body to obtain and evaluate disease morphological information and biological function information. Dose calibrator is a device used to measure the radioactivity of a single nuclide in medical institutions. Administration of the correct dose to the human body acts as an important factor in diagnosis and treatment, and measurement through a dose calibrator before administration is the most important factor. Dose calibrator performs daily quality control after installation in each medical institution. Quality control is a means of guaranteeing quality control after installation, and is essential for improving the quality of treatment and promoting patient safety. Therefore, accurate and standardized performance evaluation methods should be established. In this study, 3D printing was used for quantitative evaluation of quality control by increasing the accuracy and standardization of quality control. When the 3D printer was installed and reproducibility was tested, the error range of the expected value and reading value decreased by 0.302% in the F-18 nuclide and 0.09% in the 99mTc-pertechnate nuclide than when the 3D printer was installed. The error rate for other nuclides was also found to have a low error rate for reproducibility tests when 3D printing was installed.

Study of Practical Method for International 10~20 Electrode System (국제적인 10~20 전극시스템의 실용적인 방법에 관한 연구)

  • Kim, Sung-Hee;Lee, Ok-Kyoung;Kim, Dae Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Electroencephalography (EEG) is used for the diagnosis of epilepsy and testing the brain function. Clinical technologists are responsible for recording EEG without artifacts in accordance with the international 10~20 electrode system. Training on these techniques requires practical education. In the case of EEG, however, it is difficult for trainees to find the correct location of the electrode. Therefore, this study compared the time spent to locate the electrode attachment between traditional tape and the newly developed band. The time spent for sitting position patients using the band (196.7±61.8s) was 1084.3 s faster than the tape (1,281.0±457.4s) (P<0.001). Furthermore, the spend time spent for lying position patients using the band (200.2±49.3s) was 1217.7s faster than the tape (1417.9±482.3s) (P<0.001). Measurements using the band showed fewer differences due to various factors, such as position, practical experience, and gender. The newly developed band can locate the correct electrode attachment position quickly and efficiently, which has been a difficult problem in EEG practical education. In addition, this band is expected to be applied widely by new clinical technologists in the clinical field. Nevertheless, more study will be required to verify the accuracy of the location of the attaching electrode.

A Study on Development of Portable Concrete Crack Measurement Device Using Image Processing Technique and Laser Sensors (이미지 처리기법 및 레이저 센서를 이용한 휴대용 콘크리트 균열 측정 장치 개발에 관한 연구)

  • Seo, Seunghwan;Ohn, Syng-Yup;Kim, Dong-Hyun;Kwak, Kiseok;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.41-50
    • /
    • 2020
  • Since cracks in concrete structures expedite corrosion of reinforced concrete over a long period of time, regular on-site inspections are essential to ensure structural usability and prevent degradation. Most of the safety inspections of facilities rely on visual inspection with naked eye, so cost and time consuming are severe, and the reliability of results differs depending on the inspector. In this study, a portable measuring device that can be used for safety diagnosis and maintenance was developed as a device that measures the width and length of concrete cracks through image analysis of cracks photographed with a camera. This device captures the cracks found within a close distance (3 m), and accurately calculates the unit pixel size by laser distance measurement, and automatically calculates the crack length and width with the image processing algorithm developed in this study. In measurement results using the crack image applied to the experiment, the measurement of the length of a 0.3 mm crack within a distance of 3 m was possible with a range of about 10% error. The crack width showed a tendency to be overestimated by detecting surrounding pixels due to vibration and blurring effect during the binarization process, but it could be effectively corrected by applying the crack width reduction function.

Short-Term Outcomes of Laparoscopic Proximal Gastrectomy With Double-Tract Reconstruction Versus Laparoscopic Total Gastrectomy for Upper Early Gastric Cancer: A KLASS 05 Randomized Clinical Trial

  • Hwang, Sun-Hwi;Park, Do Joong;Kim, Hyung-Ho;Hyung, Woo Jin;Hur, Hoon;Yang, Han-Kwang;Lee, Hyuk-Joon;Kim, Hyoung-Il;Kong, Seong-Ho;Kim, Young Woo;Lee, Han Hong;Kim, Beom Su;Park, Young-Kyu;Lee, Young-Joon;Ahn, Sang-Hoon;Lee, In-Seob;Suh, Yun-Suhk;Park, Ji-Ho;Ahn, Soyeon;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.22 no.2
    • /
    • pp.94-106
    • /
    • 2022
  • Purpose: Laparoscopic proximal gastrectomy with double-tract reconstruction (LPG-DTR) is a function-preserving procedure performed for treating upper early gastric cancer (EGC). However, few studies have compared the outcomes of LPG-DTR with those of laparoscopic total gastrectomy (LTG). This study aimed at comparing the short-term outcomes of LPG-DTR between LTG and upper EGC. Materials and Methods: For upper-third EGC, a multicenter, prospective, randomized trial was performed to compare those who underwent LPG-DTR with those who underwent LTG. Short-term outcomes, including clinicopathologic results, morbidity, mortality, and postoperative courses, were evaluated using a full analysis set based on the intention-to-treat principle and the per-protocol set. Results: Of the patients, 138 who fulfilled the criteria were randomized to each group. One patient in the LPG-DTR group withdrew consent. Sixty-eight patients underwent LPG-DTR and 69 underwent LTG. The operative time (LPG-DTR=219.4 minutes; LTG=201.8 minutes; P=0.085), estimated blood loss (LPG-DTR=76.0 mL; LTG=66.1 mL; P=0.413), and the morbidity rate (LPG-DTR=23.5%; LTG=17.4%; P=0.373) between the groups were not significantly different. No mortality occurred in either of the study groups. Two weeks post operation, the Visick scores for postprandial symptoms, including reflux symptoms, were not significantly different between the groups (P=0.749). Laboratory findings on postoperative day 5 were not significantly different between the groups. Conclusions: The short-term outcomes of LPG-DTR for upper EGC were comparable to those of LTG.

A Case of Propionic Acidemia Presenting with Dilated Cardiomyopathy (확장성 심근병증으로 발현된 프로피온산혈증 1례)

  • Son, Jisoo;Choi, Yoon-Ha;Seo, Go Hun;Kang, Minji;Lee, Beom Hee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.21 no.1
    • /
    • pp.22-27
    • /
    • 2021
  • Propionic acidemia (PA) is an inherited autosomal recessive disorder, due to the deficiency of propionyl-CoA carboxylase (PCC). PCC is the enzyme which catalyzes the conversion of propionyl-CoA to D-methylmalonyl-CoA, and it is critical for the metabolism of amino acids, odd-chain fatty acids, and side chains of cholesterol. The clinical manifestations present mostly at the neonatal period with life-threatening metabolic acidosis and hyperammonemia. Here, we described a case of a 16-year-old Korean boy with late-onset PA who presented with embolic cerebral infarction due to dilated cardiomyopathy (DCMP) with left ventricular noncompaction. And he has family history of sudden cardiac death, so we performed metabolic screening and genetic tests. Elevated levels of 3-hydroxypropionic acid, methylcitric acid and propionylglycerine were detected in urine. Plasma acylcarnitine profile showed elevated propionylcarnitine (C3). Diagnosis of PA was confirmed by genetic analysis, which revealed compound heterozygous mutations, c.[1151T>G] (p.[Phe384Cys]) and c.[1228C>T] (p.[Arg410Trp]) in PCCB gene. His heart function is in improving state and the results of biochemical analysis are stable with heart failure medication and metabolic managements. We present a case of patient without episodes of metabolic decompensation who manifests DCMP as the first symptom of PA.

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Usage of digital technique to facilitate communication between dentist, dental lab technician, and patients in diagnosis and restoration for maxillary anterior implant: a case report (디지털 기법을 활용한 치과의사, 기공사, 그리고 환자 간의 효과적인 소통을 통한 전치부 임플란트의 진단 및 심미수복 증례)

  • Bang, Haemin;Jang, Woohyung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.42-51
    • /
    • 2022
  • Esthetic restoration of maxillary anterior implant heavily depends on the direction of installation of implant fixture. In patients with malpositioned implant, it is crucial to communicate the limitations of prosthetic outcome with the patient before starting on a restoration. To facilitate the communication, three-dimensional virtual representation by superimposing facial and intraoral digital scans with Computed Tomography (CT, dicom file) was used for visualization of the limitations of prosthesis. Through digital diagnostic wax-up, the profile of right maxillary anterior incisor implant was expected to be protrusive, which the patient was not satisfied with. Since the patient already had done root canal treatment on left maxillary anterior incisor due to previous trauma, a new prosthetic design including both right and left maxillary anterior incisors was presented to the patient. The second design was chosen and his comments were delivered to dental lab. The patient was satisfied with the new prosthesis, aesthetically and functionally.

Abnormal Behavior Controlled via GPR56 Expression in Microglia (미세아교세포에서 GPR56 발현에 의한 이상 행동)

  • Hyunju Kim
    • Journal of Life Science
    • /
    • v.33 no.6
    • /
    • pp.455-462
    • /
    • 2023
  • During pregnancy, maternal immune activation (MIA) from infection increases the risk of neurodevelopmental diseases, including schizophrenia and autism spectrum disorders. MIA induced by polyinosinic-polycytidylic acid (poly (I:C)) and lipopolysaccharide (LPS) in animal experiments has led to offspring with abnormal behaviors and brain development. In addition, it has recently been reported that microglia, which reside in the brain and function as immune cells, play an important role in behavioral abnormalities and brain development in MIA-induced offspring. However, the underlying mechanism remains unclear. In this study, we investigated whether microglia-specific inhibition of GPR56, a member of the G protein-coupled receptor (GPCR) family, causes behavioral abnormalities in brain development. First, MIA induction did not affect the microglia population, but when examining the expression of microglial GRP56 in MIA-induced fetuses, GPR56 expression was inhibited between embryonic days 14.5 (E14.5) and E18.5 regardless of sex. Furthermore, microglial GPR56-suppressed mice showed abnormal behaviors in the MIA-induced offspring, including sociability deficits, repetitive behavioral patterns, and increased anxiety levels. Although abnormal cortical development such as that in the MIA-induced offspring were not observed in the microglial GPR56-suppressed mice, their brain activity was observed through c-fos staining. These results suggest that microglia-specific GPR56 deficiency may cause abnormal behaviors and could be used as a biomarker for the diagnosis and/or as a therapeutic target of behavioral deficits in MIA offspring.