• 제목/요약/키워드: Diagnosability

검색결과 9건 처리시간 0.023초

PMC 모델과 비교진단 모델을 이용한 하이퍼-스타 연결망의 진단도 분석 (Analysis of Diagnosability for Hyper-Star Network Under the PMC and the Comparison Diagnosis Model)

  • 김종석;이형옥
    • 정보처리학회논문지A
    • /
    • 제13A권1호
    • /
    • pp.19-26
    • /
    • 2006
  • 진단도는 상호연결망의 신뢰도를 측정하는 중요한 요소 중 하나이다. 고장 노드를 진단하기 위한 대표적인 모델로 PMC 모델과 비교진단 모델이 있다. 본 논문에서는 두 모델을 이용하여 정규연결망 하이퍼-스타 HS(2n,n)의 진단도(Diagnosability)가 n임을 보인다.

젖소에서의 산욕기질병 발생예견에 관한 연구 (A Study on the Prediction of Parturient Syndrome in Holstein Cows)

  • 윤화영;최희인
    • 한국임상수의학회지
    • /
    • 제2권1호
    • /
    • pp.133-141
    • /
    • 1985
  • In order to establish a method predicting susceptible cows to the parturient syndrome, various serum chemical parameters (calcium, phosphorus, Ca/P, magnesium, cholesterol, total protein, albumin, globulin, A/G, total lipid, non-esterified fatty acid(NEFA) and aspartate aminotransferase(AST)) were measured during late pregnancy and their relationships with periparturient diseases were investigated during puerpural period. The results obtained were as follows : 1. The factors affecting the prediction of susceptible cows to parturient syndrome were calcium, magnesium, total protein, globulin, A/G ratio and total lipid at 30 day antepartum and the diagnosability was 70.7%. 2. In the experimental cows producing more than 21kg of milk per day, the factors affecting the prediction of susceptible cows to parturient syndrome were calcium, NEFA and A/G ratio at 30 day antepartum and the diagnosability was 66.7%. 3. In the experimental cows calved more than 3 times, the factors affecting the perdiction of susceptible cows to parturient syndrome were calcium, total protein, albumin and NEFA at 30 day antepartum and the diagnosability was 83.3%.

  • PDF

무선 심전도 신호의 판독 향상을 위한 손실데이터 보간 (Interpolating Missing ECG Samples to Improve Diagnosability)

  • 박주영;한상화;유호민;이재면;강경태
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2012년도 한국컴퓨터종합학술대회논문집 Vol.39 No.1(D)
    • /
    • pp.233-234
    • /
    • 2012
  • 무선 심전도 모니터링 기술로 인해 환자가 병원 내 어디에 있든 이들의 심전도를 원격에서 상시 관찰하는 것이 가능해 졌다. 그러나 무선 구간은 에러에 취약할 수 밖에 없으며 그 결과 원격 모니터에서 복원한 심전도 신호는 왜곡될 수 밖에 없다. 본 연구에서는 이러한 문제를 완화하여 복원 심전도 신호의 판독 가능성을 높이기 위한 두 가지 손실 데이터 보간 기법을 소개하고 그들의 성능을 평가한다.

Wireless LAN with Medical-Grade QoS for E-Healthcare

  • Lee, Hyung-Ho;Park, Kyung-Joon;Ko, Young-Bae;Choi, Chong-Ho
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.149-159
    • /
    • 2011
  • In this paper, we study the problem of how to design a medical-grade wireless local area network (WLAN) for healthcare facilities. First, unlike the IEEE 802.11e MAC, which categorizes traffic primarily by their delay constraints, we prioritize medical applications according to their medical urgency. Second, we propose a mechanism that can guarantee absolute priority to each traffic category, which is critical for medical-grade quality of service (QoS), while the conventional 802.11e MAC only provides relative priority to each traffic category. Based on absolute priority, we focus on the performance of real-time patient monitoring applications, and derive the optimal contention window size that can significantly improve the throughput performance. Finally, for proper performance evaluation from a medical viewpoint, we introduce the weighted diagnostic distortion (WDD) as a medical QoS metric to effectively measure the medical diagnosability by extracting the main diagnostic features of medical signal. Our simulation result shows that the proposed mechanism, together with medical categorization using absolute priority, can significantly improve the medical-grade QoS performance over the conventional IEEE 802.11e MAC.

전립선암 환자의 뼈 전이에 대한 $^{18}F$-Fluoride PET/CT의 유용성 (Usefulness of $^{18}F$-Fluoride PET/CT in Bone Metastasis of Prostate Cancer)

  • 박민수;김정열;박훈희;강천구;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.24-30
    • /
    • 2009
  • 국내의 암 발생 변화 추이를 고려해보면, 현재 남성에게 발생하는 전립선암의 비중이 나날이 증가하고 있다. 전립선 암의 경우 림프절이나 뼈에 전이가 되면 90% 이상 사망에 이른다. 따라서 최근 핵의학 분야에서는 전립선 암의 뼈 전이를 보다 정확하게 진단하기 위해 여러 영상기법과 방사성 의약품의 개발이 진행, 소개되고 있다. 본 연구에서는 전립선 암세포의 뼈 전이에 대한 보다 정밀한 영상을 획득하여 진단능을 향상시키는 $^{18}F$-Fluoride PET/CT의 유용성을 알아보고자 한다. 본 연구는 총 33명의 전립선암으로 진단된 환자로서, 평균 $67.8{\pm}10.2$세의 남자를 대상으로 하였다. 동일한 환자에게 각각 전신 뼈 검사(Whole Body Bone Scan; WBBS)와 뼈 양전자 방출 컴퓨터 단층 촬영(18F-Fluoride Positron Emission Tomography/Computed Tomography; $^{18}F$-Fluoride PET/CT)을 시행하였으며, 각 검사에서 나타난 병변을 확인하여 ROC곡선(Receiver Operating Characteristic Curve)을 통해 AUROC (The Area Under an ROC)분석하였다. 또한 두 검사의 민감도와 특이도, 양성예측률과 음성예측률 그리고 두 검사의 정확도를 비교 분석하였다. 총 33명 중 22명의 환자(66.6%)에게서 뼈 전이가 있었으며, $^{18}F$-Fluoride PET/CT에서 모두 우수한 결과치가 나타났다. WBBS의 민감도는 63.6%, 특이도는 81.8%였고, $^{18}F$-Fluoride PET/CT에서는 민감도 100%, 특이도 90.9%로 나타났으며, AUROC를 비교한 결과 WBBS에서 0.778, $^{18}F$-Fluoride PET/CT는 0.942로 분석되었다. $^{18}F$-Fluoride PET/CT는 WBBS에 비하여 높은 민감도와 특이도를 보였으며, 3D 영상 구현으로 암세포의 뼈에 대한 전이성 병소를 더욱 정확하고 명확하게 발견할 수 있었다. 또한 WBBS의 장시간 검사에 비하여 $^{18}F$-Fluoride PET/CT는 상대적으로 단시간에 뼈의 생리적인 변화에 대한 정확한 영상을 얻을 수 있어 환자의 불편함을 최소화 할 수 있었다. 고가 검사비용에 대한 부담을 줄일 수 있다면 $^{18}F$-Fluoride PET/CT를 통해 더욱 정확한 영상을 제공하여 임상에서의 진단능을 향상 시킬 수 있을 것으로 사료된다.

  • PDF

근로자 건강진단시 간기능 이상자의 정밀검사항목 개선을 위한 조사연구 (A Baseline Study on the Choice of Optimal Screening Test Items among Workers with Abnormal Liver Function Tests on Workers' Periodic Health Examination)

  • 정해관;임현술;김규회
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권4호
    • /
    • pp.747-761
    • /
    • 1994
  • Workers' periodic health examination is the main tools used to manage the health problems of most workers in Korea. The most common health problem found in workers' periodic health examination is liver disorder. Liver disorder is also one of the most common health problems in general population and one of the leading causes of mortality in adult population. Regulation proposed by government (No. 207, Ministry of Labor, 1992) defines the criteria for selection of workers with the liver dysfunction for further evaluative examination and the examination items used for diagnosis of the workers with liver dysfunction. This study was designed to evaluate the proficiency of each examination items presently defined in Regulation and propose the optimal examination items for detection of the liver disorders found by workers' periodic health examination. Study subjects are 186 workers with abnormal liver function tests in screening examination of workers' periodic health examination. Questionnaire survey including past history of liver disorder, drinking history, height and weight was done. Physical examination by physician, routine test items defined by Regulation (SGOT, SGPT, $\gamma$-GTP, protein, albumin, total and direct bilirubin, alkaline phosphatase, $\alpha$-feto protein, HBsAg and anti-HBs), anti-HCV antibody test and liver ultrasonography were done. Results are as follows; 1. Result of evaluative examination utilizing only the items defined in Regulation was; There were 75 workers with suspected live. disorder(40.3%), 63 with no liver dysfunction (33.9%), 13 with suspected hepatitis B(7.0%), 10 workers with hepatitis B(5.4%), 10 workers with hepatitis B carrier state(5.4%), 10 with alcoholic liver disorders(5.4%), 5 with fatty liver(2.7%). When alternative diagnostic criteria applying additional examination items (drinking history, body mass index, anti-HCV antibody and ultrasonography) diagnosability of liver disorder was increased. When all four items were included, final results were; 23 workers (17.8%) with hepatitis B (10 carriers, 13 suspects and 10 hepatitis B), 10 (5.4%) with hepatitis C(4 carriers, 5 suspects and 1 hepatitis C), 13(7.0%) with alcoholic liver disorder, 45(24.2%) with fatty liver (40 suspects, 5 fatty liver), 410%) with suspected liver disorders and 44 (23.7%) with normal liver. 2. Of examination items defined by Regulation, only SGOT, SGPT, $\gamma$-GTP and HBsAg were significantly different in abnormal rate and mean value, and all other laboratory findings did not showed significant difference between two groups. Drinking history, body mass index and anti-HCV antibody test which are the items that authors included in this study, also showed significant difference between two groups. Utilization of body mass index (BMI) for abnormal liver function group in diagnosis of fatty liver had high specificity (97.6%) but sensitivity (22.3%) was low. Therefore we suggest that SGOT, SGPT, $\gamma$-GTP, HBsAg, alcohol drinking history, BMI and anti-HCV Ab were useful for diagnosis of liver disorders among worker's periodic health examination.

  • PDF

모자건강관리를 위한 위험요인별 감별평점분류기준 개발에 관한 연구 (A Study on the Risk Factors for Maternal and Child Health Care Program with Emphasis on Developing the Risk Score System)

  • 이광옥
    • 대한간호학회지
    • /
    • 제13권1호
    • /
    • pp.7-21
    • /
    • 1983
  • For the flexible and rational distribution of limited existing health resources based on measurements of individual risk, the socalled Risk Approach is being proposed by the World Health Organization as a managerial tool in maternal and child health care program. This approach, in principle, puts us under the necessity of developing a technique by which we will be able to measure the degree of risk or to discriminate the future outcomes of pregnancy on the basis of prior information obtainable at prenatal care delivery settings. Numerous recent studies have focussed on the identification of relevant risk factors as the Prior infer mation and on defining the adverse outcomes of pregnancy to be dicriminated, and also have tried on how to develope scoring system of risk factors for the quantitative assessment of the factors as the determinant of pregnancy outcomes. Once the scoring system is established the technique of classifying the patients into with normal and with adverse outcomes will be easily de veloped. The scoring system should be developed to meet the following four basic requirements. 1) Easy to construct 2) Easy to use 3) To be theoretically sound 4) To be valid In searching for a feasible methodology which will meet these requirements, the author has attempted to apply the“Likelihood Method”, one of the well known principles in statistical analysis, to develop such scoring system according to the process as follows. Step 1. Classify the patients into four groups: Group $A_1$: With adverse outcomes on fetal (neonatal) side only. Group $A_2$: With adverse outcomes on maternal side only. Group $A_3$: With adverse outcome on both maternal and fetal (neonatal) sides. Group B: With normal outcomes. Step 2. Construct the marginal tabulation on the distribution of risk factors for each group. Step 3. For the calculation of risk score, take logarithmic transformation of relative proport-ions of the distribution and round them off to integers. Step 4. Test the validity of the score chart. h total of 2, 282 maternity records registered during the period of January 1, 1982-December 31, 1982 at Ewha Womans University Hospital were used for this study and the“Questionnaire for Maternity Record for Prenatal and Intrapartum High Risk Screening”developed by the Korean Institute for Population and Health was used to rearrange the information on the records into an easy analytic form. The findings of the study are summarized as follows. 1) The risk score chart constructed on the basis of“Likelihood Method”ispresented in Table 4 in the main text. 2) From the analysis of the risk score chart it was observed that a total of 24 risk factors could be identified as having significant predicting power for the discrimination of pregnancy outcomes into four groups as defined above. They are: (1) age (2) marital status (3) age at first pregnancy (4) medical insurance (5) number of pregnancies (6) history of Cesarean sections (7). number of living child (8) history of premature infants (9) history of over weighted new born (10) history of congenital anomalies (11) history of multiple pregnancies (12) history of abnormal presentation (13) history of obstetric abnormalities (14) past illness (15) hemoglobin level (16) blood pressure (17) heart status (18) general appearance (19) edema status (20) result of abdominal examination (21) cervix status (22) pelvis status (23) chief complaints (24) Reasons for examination 3) The validity of the score chart turned out to be as follows: a) Sensitivity: Group $A_1$: 0.75 Group $A_2$: 0.78 Group $A_3$: 0.92 All combined : 0.85 b) Specificity : 0.68 4) The diagnosabilities of the“score chart”for a set of hypothetical prevalence of adverse outcomes were calculated as follows (the sensitivity“for all combined”was used). Hypothetidal Prevalence : 5% 10% 20% 30% 40% 50% 60% Diagnosability : 12% 23% 40% 53% 64% 75% 80%.

  • PDF

PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰 (The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT)

  • 박민수;함준철;조용인;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.35-43
    • /
    • 2012
  • CT를 기반으로 감쇠 보정이 시행되는 PET/CT 검사에서는 금속 삽입물에 의한 선속 경화 현상 (Beam Hardening Artifact)으로 인공물이 발생 된다. 이는 인접한 부위의 과대 혹은 과소 평가를 유발하는 감쇠 보정으로 인해 $^{18}F$-FDG의 섭취 변화를 가져오며 영상의 질과 비뇨 생식기 질환의 진단능을 저하시킨다. 따라서 본 연구에서는 PET/CT 영상의 질 향상을 위한 금속 인공물 저감 (Metal Artifact Reduction, MAR) algorithm 재구성방법의 유용성을 평가하고자 한다. 인공 고관절 삽입물에 대한 인공물을 평가하기 위해 SPECT/PET Phantom에 고관절 삽입물을 고정 하여 PET/CT를 진행했다. W/O MAR algorithm 영상과 MAR algorithm 영상에서 CT상에 나타나는 Bright streak, Dark streak, Metal과 Background의 영역에서의 표준화 섭취 계수(Standardized Uptake Value)의 변화를 분석하였다. 또한 본원에 내원한 고관절 전치환술을 시행한 15명의 환자에게서 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상을 비교 평가하였다. W/O MAR algorithm 영상에서 SUV는 Bright streak 영역에서는 $0.98{\pm}0.48$ g/ml, Dark streak 영역에서는 $0.88{\pm}0.02$ g/ml, Metal 영역에는 $0.24{\pm}0.16$ g/ml, Background 영역은 $0.91{\pm}0.18$ g/ml로 측정되었다. 하지만 MAR algorithm 영상에서는 Bright streak 영역에서는 $0.88{\pm}0.49$ g/ml, Dark streak 영역은 $0.63{\pm}0.21$ g/ml, Metal 영역에서는 $0.06{\pm}0.07$ g/ml, Background는 $0.90{\pm}0.02$ g/ml로 측정되었다. MAR algorithm 적용 시 SUV가 평균적으로 감소 하였으며, W/O MAR algorithm 영상에서는 Bright streak영역에서 Background 보다 높게 측정되어 false positive uptake로 나타났으나 MAR algorithm 영상에서는 Background와 비슷한 농도와 SUV가 나타났고, false positive uptake가 관찰되지 않았다. 따라서 MAR algorithm을 적용하여 인공 고관절 삽입물 주변 조직의 과대 혹은 과소 감쇠 보정으로 인한 섭취의 증가를 줄일 수 있었다. 하지만 Dark streak 영역에서의 SUV 저하를 줄이기 위한 방안은 더욱 많은 연구가 이뤄져야 할 것이다. 고관절 삽입 인공물로 인해 발생하는 Bright streak 영역에서의 false positive uptake를 감소시키고 이와 인접해 있는 비뇨 생식기 질환에 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상이 동시에 제공된다면 더욱 진단능을 향상 시킬 수 있으리라 생각된다.

  • PDF

결핵균 분비항원을 이용한 결핵의 혈청학적 진단 방법에 대한 평가 (Evaluation of a Serodiagnostic Method for Tuberculosis by Using Secreted Protein Antigens of Mycobacterium Tuberculosis)

  • 배길한;박은미;김상재
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권3호
    • /
    • pp.315-323
    • /
    • 2000
  • 연구배경 : 현행 도말 및 배양등의 미생물학적 검사법의 제한점을 보완 또는 보조할 수 있는 신속한 결핵진단 방법의 하나로서 가장 많이 연구 되어온 분야가 혈청학적인 방법이다. 이 중 현재까지 결핵의 혈청학적 진단에 유용성이 높은 것으로 평가되는 항원의 하나가 38KDa으로 대표되는 결핵균 분비항원이다. 마침, 이 38KDa 항원을 주항원 성분으로 하여, 간편하게 실험할 수 있도록 kit화된 제품이 국내외에서 널리 시판되고 있기에(ICT-TB, 호주 ICT Diagnostics사) 이를 이용, 결핵의 혈청학적 진단이 얼마나 유용할 것인지를 평가하고자 하였다. 방 법 : 결핵이 없는 7세 이하 아동 21명과 건강 성인 47명 등 총 68명의 대조군과, 치료 개시 전에는 균양성이었으나 ICT 검사 당시는 균이 나오지는 않았던 치료 중인 폐결핵환자 82명 (결핵성 흉막염 환자 3명 포함) 및 균양성으로 당시 치료 중이던 폐결핵환자 40명 등, 총 122명의 결핵환자를 대상으로 하여 결핵의 혈청학적 진단용 kit인 ICT를 이용하여 시험하였다. 결 과 : 1. 결핵환자가 아닌 대조용 대상자 68명(7세 이하 아동 21명 포함)에 대한 ICT의 양성반응률 (위양성률)은 13.2%였고, 음성반응률 (결핵환자가 아닌 것으로 판정되는 율, true negative)은 86.8%였다. 2. 시험된 대상 결핵환자 122명에 대한 ICT에 의한 양성반응률은 86.9%, 음성반응률은 13.1%였다. 3. 균양성 폐결핵 환자 40명에 대한 ICT 양성률은 95.0% (38명), 음성률은 5.0% (2명)였다. 4. 폐외결핵환자 3명을 포함한, 현재 치료 중에 있는 균음성 결핵환자에 82명에 대한 ICT의 양성반응률은 82.9%(68 명), 음성반응률은 17.1%(14명)였다. 그러나, 균양성 결핵환자와 균음성인 결핵환자간 ICT 양성률에는 통계적으로 유의한 차이가 없었다(P>0.05). 5.ICT의 민강도와 특이도는 모두 87%였으며, 위양성률과 위음성률도 같은 13%였다. 또 유병율이 64% 수준일 때의 양성예측률은 92.2%, 음성예측률은 78.7%였다. 결 론 : ICT의 높은 위양성률과 진단능률(diagnosability) 등을 고려할 때, 결핵이 의심되지만 기존의 도말 및 배양검사 결과를 얻기 어려운 대상자에게만 필요에 따라 제한적으로 활용해볼 수 있는 검사인 것으로 판단되었다.

  • PDF