• Title/Summary/Keyword: Diagnosability

Search Result 9, Processing Time 0.027 seconds

Analysis of Diagnosability for Hyper-Star Network Under the PMC and the Comparison Diagnosis Model (PMC 모델과 비교진단 모델을 이용한 하이퍼-스타 연결망의 진단도 분석)

  • Kim Jong-Seok;Lee Hyeong-Ok
    • The KIPS Transactions:PartA
    • /
    • v.13A no.1 s.98
    • /
    • pp.19-26
    • /
    • 2006
  • Diagnosability is an important factor in measuring the reliability of an interconnection network. Typical models of fault diagnosis are the PMC and the comparison diagnosis model. In this paper, we prove that the regular network Hyper-Star HS(2n,n) under two models is n-diagnosable.

A Study on the Prediction of Parturient Syndrome in Holstein Cows (젖소에서의 산욕기질병 발생예견에 관한 연구)

  • Youn Hwa-Young;Choi Hee-In
    • Journal of Veterinary Clinics
    • /
    • v.2 no.1
    • /
    • pp.133-141
    • /
    • 1985
  • In order to establish a method predicting susceptible cows to the parturient syndrome, various serum chemical parameters (calcium, phosphorus, Ca/P, magnesium, cholesterol, total protein, albumin, globulin, A/G, total lipid, non-esterified fatty acid(NEFA) and aspartate aminotransferase(AST)) were measured during late pregnancy and their relationships with periparturient diseases were investigated during puerpural period. The results obtained were as follows : 1. The factors affecting the prediction of susceptible cows to parturient syndrome were calcium, magnesium, total protein, globulin, A/G ratio and total lipid at 30 day antepartum and the diagnosability was 70.7%. 2. In the experimental cows producing more than 21kg of milk per day, the factors affecting the prediction of susceptible cows to parturient syndrome were calcium, NEFA and A/G ratio at 30 day antepartum and the diagnosability was 66.7%. 3. In the experimental cows calved more than 3 times, the factors affecting the perdiction of susceptible cows to parturient syndrome were calcium, total protein, albumin and NEFA at 30 day antepartum and the diagnosability was 83.3%.

  • PDF

Interpolating Missing ECG Samples to Improve Diagnosability (무선 심전도 신호의 판독 향상을 위한 손실데이터 보간)

  • Park, Ju-Young;Han, Sang-Hwa;Yoo, Ho-Min;Lee, Jae-Myoun;Kang, Kyung-Tae
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06d
    • /
    • pp.233-234
    • /
    • 2012
  • 무선 심전도 모니터링 기술로 인해 환자가 병원 내 어디에 있든 이들의 심전도를 원격에서 상시 관찰하는 것이 가능해 졌다. 그러나 무선 구간은 에러에 취약할 수 밖에 없으며 그 결과 원격 모니터에서 복원한 심전도 신호는 왜곡될 수 밖에 없다. 본 연구에서는 이러한 문제를 완화하여 복원 심전도 신호의 판독 가능성을 높이기 위한 두 가지 손실 데이터 보간 기법을 소개하고 그들의 성능을 평가한다.

Wireless LAN with Medical-Grade QoS for E-Healthcare

  • Lee, Hyung-Ho;Park, Kyung-Joon;Ko, Young-Bae;Choi, Chong-Ho
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • In this paper, we study the problem of how to design a medical-grade wireless local area network (WLAN) for healthcare facilities. First, unlike the IEEE 802.11e MAC, which categorizes traffic primarily by their delay constraints, we prioritize medical applications according to their medical urgency. Second, we propose a mechanism that can guarantee absolute priority to each traffic category, which is critical for medical-grade quality of service (QoS), while the conventional 802.11e MAC only provides relative priority to each traffic category. Based on absolute priority, we focus on the performance of real-time patient monitoring applications, and derive the optimal contention window size that can significantly improve the throughput performance. Finally, for proper performance evaluation from a medical viewpoint, we introduce the weighted diagnostic distortion (WDD) as a medical QoS metric to effectively measure the medical diagnosability by extracting the main diagnostic features of medical signal. Our simulation result shows that the proposed mechanism, together with medical categorization using absolute priority, can significantly improve the medical-grade QoS performance over the conventional IEEE 802.11e MAC.

Usefulness of $^{18}F$-Fluoride PET/CT in Bone Metastasis of Prostate Cancer (전립선암 환자의 뼈 전이에 대한 $^{18}F$-Fluoride PET/CT의 유용성)

  • Park, Min-Soo;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.24-30
    • /
    • 2009
  • Purpose: Today, Prostate cancer has been gradually increasing, according to the change of internal incidence rate of cancer. Generally, prostate cancer has lead to dead over 90%, in case of metastasis of lymph node and bone. So, innovative development of new radiopharmaceutical and imaging modality is progressed for detection of that metastasis, in nuclear medicine, now. Therefore, this study shows the usefulness of $^{18}F$-Fluoride PET/CT improved diagnosability on bone metastasis of prostate cancer. Materials and Methods: In this study, 33 male patients with prostate cancer were examined (The mean age: $67.8{\pm}10.2$ years old). Every patient was done each whole body bone scan (WBBS) and $^{18}F$-Fluoride positron emission tomography/computed tomography ($^{18}F$-Fluoride PET/CT). And then, using Receiver Operating Characteristic Curve (ROC curve), each sensitivity and specificity of two modalities was measured and compared with. Results: In 22 patients (66.6%) of all, bone metastasis was detected. And, in WBBS, sensitivity was 63.6%, specificity, 81.8%; in $^{18}F$-Fluoride PET/CT, sensitivity was 100% and specificity was 90.9%. As a result of ROC curve, AUROC (The Area under an ROC) of WBBS was 0.778, and that of $^{18}F$-Fluoride PET/CT, 0.942. Conclusions: $^{18}F$-Fluoride PET/CT was higher both sensitivity and specificity than WBBS, and it was valuable to detect bone metastasis of prostate cancer more definitely, with 3D imaging realization. Also, in $^{18}F$-Fluoride PET/CT, physiological images were acquired in more short time than WBBS, so, it was possible to reduce patient's waiting time and complaint. Therefore, it is considered that $^{18}F$-Fluoride PET/CT is able to improve diagnosability by offering more accurate images, as cuts in a share of high cost.

  • PDF

A Baseline Study on the Choice of Optimal Screening Test Items among Workers with Abnormal Liver Function Tests on Workers' Periodic Health Examination (근로자 건강진단시 간기능 이상자의 정밀검사항목 개선을 위한 조사연구)

  • Cheong, Hae-Kwan;Lim, Hyun-Sul;Kim, Gyu-Hoi
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.4 s.48
    • /
    • pp.747-761
    • /
    • 1994
  • Workers' periodic health examination is the main tools used to manage the health problems of most workers in Korea. The most common health problem found in workers' periodic health examination is liver disorder. Liver disorder is also one of the most common health problems in general population and one of the leading causes of mortality in adult population. Regulation proposed by government (No. 207, Ministry of Labor, 1992) defines the criteria for selection of workers with the liver dysfunction for further evaluative examination and the examination items used for diagnosis of the workers with liver dysfunction. This study was designed to evaluate the proficiency of each examination items presently defined in Regulation and propose the optimal examination items for detection of the liver disorders found by workers' periodic health examination. Study subjects are 186 workers with abnormal liver function tests in screening examination of workers' periodic health examination. Questionnaire survey including past history of liver disorder, drinking history, height and weight was done. Physical examination by physician, routine test items defined by Regulation (SGOT, SGPT, $\gamma$-GTP, protein, albumin, total and direct bilirubin, alkaline phosphatase, $\alpha$-feto protein, HBsAg and anti-HBs), anti-HCV antibody test and liver ultrasonography were done. Results are as follows; 1. Result of evaluative examination utilizing only the items defined in Regulation was; There were 75 workers with suspected live. disorder(40.3%), 63 with no liver dysfunction (33.9%), 13 with suspected hepatitis B(7.0%), 10 workers with hepatitis B(5.4%), 10 workers with hepatitis B carrier state(5.4%), 10 with alcoholic liver disorders(5.4%), 5 with fatty liver(2.7%). When alternative diagnostic criteria applying additional examination items (drinking history, body mass index, anti-HCV antibody and ultrasonography) diagnosability of liver disorder was increased. When all four items were included, final results were; 23 workers (17.8%) with hepatitis B (10 carriers, 13 suspects and 10 hepatitis B), 10 (5.4%) with hepatitis C(4 carriers, 5 suspects and 1 hepatitis C), 13(7.0%) with alcoholic liver disorder, 45(24.2%) with fatty liver (40 suspects, 5 fatty liver), 410%) with suspected liver disorders and 44 (23.7%) with normal liver. 2. Of examination items defined by Regulation, only SGOT, SGPT, $\gamma$-GTP and HBsAg were significantly different in abnormal rate and mean value, and all other laboratory findings did not showed significant difference between two groups. Drinking history, body mass index and anti-HCV antibody test which are the items that authors included in this study, also showed significant difference between two groups. Utilization of body mass index (BMI) for abnormal liver function group in diagnosis of fatty liver had high specificity (97.6%) but sensitivity (22.3%) was low. Therefore we suggest that SGOT, SGPT, $\gamma$-GTP, HBsAg, alcohol drinking history, BMI and anti-HCV Ab were useful for diagnosis of liver disorders among worker's periodic health examination.

  • PDF

A Study on the Risk Factors for Maternal and Child Health Care Program with Emphasis on Developing the Risk Score System (모자건강관리를 위한 위험요인별 감별평점분류기준 개발에 관한 연구)

  • 이광옥
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.1
    • /
    • pp.7-21
    • /
    • 1983
  • For the flexible and rational distribution of limited existing health resources based on measurements of individual risk, the socalled Risk Approach is being proposed by the World Health Organization as a managerial tool in maternal and child health care program. This approach, in principle, puts us under the necessity of developing a technique by which we will be able to measure the degree of risk or to discriminate the future outcomes of pregnancy on the basis of prior information obtainable at prenatal care delivery settings. Numerous recent studies have focussed on the identification of relevant risk factors as the Prior infer mation and on defining the adverse outcomes of pregnancy to be dicriminated, and also have tried on how to develope scoring system of risk factors for the quantitative assessment of the factors as the determinant of pregnancy outcomes. Once the scoring system is established the technique of classifying the patients into with normal and with adverse outcomes will be easily de veloped. The scoring system should be developed to meet the following four basic requirements. 1) Easy to construct 2) Easy to use 3) To be theoretically sound 4) To be valid In searching for a feasible methodology which will meet these requirements, the author has attempted to apply the“Likelihood Method”, one of the well known principles in statistical analysis, to develop such scoring system according to the process as follows. Step 1. Classify the patients into four groups: Group $A_1$: With adverse outcomes on fetal (neonatal) side only. Group $A_2$: With adverse outcomes on maternal side only. Group $A_3$: With adverse outcome on both maternal and fetal (neonatal) sides. Group B: With normal outcomes. Step 2. Construct the marginal tabulation on the distribution of risk factors for each group. Step 3. For the calculation of risk score, take logarithmic transformation of relative proport-ions of the distribution and round them off to integers. Step 4. Test the validity of the score chart. h total of 2, 282 maternity records registered during the period of January 1, 1982-December 31, 1982 at Ewha Womans University Hospital were used for this study and the“Questionnaire for Maternity Record for Prenatal and Intrapartum High Risk Screening”developed by the Korean Institute for Population and Health was used to rearrange the information on the records into an easy analytic form. The findings of the study are summarized as follows. 1) The risk score chart constructed on the basis of“Likelihood Method”ispresented in Table 4 in the main text. 2) From the analysis of the risk score chart it was observed that a total of 24 risk factors could be identified as having significant predicting power for the discrimination of pregnancy outcomes into four groups as defined above. They are: (1) age (2) marital status (3) age at first pregnancy (4) medical insurance (5) number of pregnancies (6) history of Cesarean sections (7). number of living child (8) history of premature infants (9) history of over weighted new born (10) history of congenital anomalies (11) history of multiple pregnancies (12) history of abnormal presentation (13) history of obstetric abnormalities (14) past illness (15) hemoglobin level (16) blood pressure (17) heart status (18) general appearance (19) edema status (20) result of abdominal examination (21) cervix status (22) pelvis status (23) chief complaints (24) Reasons for examination 3) The validity of the score chart turned out to be as follows: a) Sensitivity: Group $A_1$: 0.75 Group $A_2$: 0.78 Group $A_3$: 0.92 All combined : 0.85 b) Specificity : 0.68 4) The diagnosabilities of the“score chart”for a set of hypothetical prevalence of adverse outcomes were calculated as follows (the sensitivity“for all combined”was used). Hypothetidal Prevalence : 5% 10% 20% 30% 40% 50% 60% Diagnosability : 12% 23% 40% 53% 64% 75% 80%.

  • PDF

The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT (PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰)

  • Park, Min Soo;Ham, Jun Cheol;Cho, Yong In;Kang, Chun Goo;Park, Hoon-Hee;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.35-43
    • /
    • 2012
  • Purpose : PET/CT performed CT-based attenuation correction generates the beam hardening artifact by metallic implant. The attenuation correction causes over or underestimate of the area adjacent to metallic hip prosthetic material and change of $^{18}F$-FDG uptake. Also, the image quality and the diagnosability on genitourinary disease are reduced. Therefore, this study will evaluate the usefulness of MAR (Metal Artifact Reduction) algorithm method to improve the image quality on PET/CT. Materials and Methods : PET/CT was performed by fixing hip prosthesis in SPECT/PET phantom. In PET images with and Without MAR algorithm, the Bright streak, Dark streak, Metal region and Background area that appeared on CT were confirmed, and the change of each SUV (standardized uptake value) was analyzed. Also, in 15 patients who underwent total hip arthroplasty, each MAR algorithm and Without MAR algorithm and non attenuation correction was evaluated. Results : In PET image Without MAR algorithm, SUV of Bright streak region was $0.98{\pm}0.48$ g/ml; Dark streak region was $0.88{\pm}0.02$ g/ml; Metal region was $0.24{\pm}0.16$ g/ml, Background area was $0.91{\pm}0.18$ g/ml. In SUV of PET image with MAR algorithm, Bright streak region was $0.88{\pm}0.49$ g/ml, Dark streak region was $0.63{\pm}0.21$ g/ml, Metal region was $0.06{\pm}0.07$ g/ml, Background was $0.90{\pm}0.02$ g/ml. SUV generally decreased when applying MAR algorithm. In PET image Without MAR algorithm, SUVs of Bright region were higher than those measured in the Background, and it was false positive uptake. But, in PET image with MAR algorithm, SUVs of Bright region were similar to the Background, and false positive uptake disappeared. Conclusion : MAR algorithm could reduce an increase of $^{18}F$-FDG uptake due to attenuation correction in the hip surrounding tissue. However, decrease of SUV in Dark streak region should be considered in the future. Therefore, this study propose that the diagnostic accuracy can be improved in genitourinary diseases adjacent to metallic hip prosthesis, if provided PET images with and Without MAR algorithm, and non attenuation correction images at the same time.

  • PDF

Evaluation of a Serodiagnostic Method for Tuberculosis by Using Secreted Protein Antigens of Mycobacterium Tuberculosis (결핵균 분비항원을 이용한 결핵의 혈청학적 진단 방법에 대한 평가)

  • Bai, Gill-Han;Park, Eun-Mi;Kim, Sang-Jae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.315-323
    • /
    • 2000
  • Background : An immunochromatographic assay (ICT Diagnostics) which facilitates the diagnosis of tuberculosis(TB) by detecting serum antibodies mainly directed against specific 38KDa of Mycobacterium tuberculosis has come into the market. The test consists of a cardboard folding device containing nitrocellulose strip and absorbent pads. The whole procedure is completed within 15 min and does not require any additional equipment. The test has been reported to be sensitive and specific in diagnosing active TB. Thus the test had been evaluated with sera from TB patients and TB-free subjects. Method : Sera from patients with active pulmonary tuberculosis(40 sputum positives for Mycobacterium tuberculosis, 79 sputum negatives, and 3 extrapulmonary tuberculosis) were obtained from the Double-Cross Chest Clinic of the Korean National Tuberculosis Association (KNTA) in Seoul. The control group consisted of TB-free 68 subjects(21 children under 7 years old and 47 healthy staff members of KNTA). Results : Nine out of 68(13.2%) TB-free controls had positive antibody response. Total 106 of 122(86.9%) radiologically active patients had positive antibodies while 16 (13.1%) showed negative reaction. Antibody was detected in 38 of 40(95.0%) sputum positive patients and 68 of 82(82.9%) sputum negative patients who were under the antituberculosis chemotherapy. The sensitivity and specificity were all 87% and the positive predictive value was 92.2% while the negative predictive value was 78.7%, when the prevalence of TB in the sample was 64.2%. Our results clearly show that the detection of antibodies which mainly react with the 38KDa antigen of M. tuberculosis is not suitable as the first-line method of diagnosis but considered only as an adjunctive test to standard techniques of tuberculosis diagnosis. when considering its high false positivity.

  • PDF