• Title/Summary/Keyword: Dew point

Search Result 192, Processing Time 0.021 seconds

A Study on Humid Control Characteristics of Alkaline Desiccants (알칼리성 용해제의 조습특성에 관한 연구)

  • Hong, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.169-173
    • /
    • 2010
  • Many salts have the ability to attract and remove water vapor from the surrounding environment. The ability of each salt to remove water vapor is based on the flow rate and temperature of air in surrounding. The objective of this study was toinvestigate the humid control characteristics in air-water system by using a desiccants. The aim is to asses the influence of three parameters on the humid control process which are air volume rate, air temperature and desiccant amount. Humidity control materials which consist of K (potassium) or Na (sodium) have been synthesized by the aqueous process. The humidity control properties of materials have been also investigated. Experiment results are as following. Thermal characteristics of desiccants showed similar properties regardless of processing condition. The experiments were examined by using artificial air-water system (humidity : 70~93%, air volume rate : $0.22{\sim}0.69m^3/s$). The results showed that the Na-type desiccant was an effective material. It was found that dew point increased with air volume rate, and the humidity change in humid control process was depended on desiccants amount.

A Study on Operating Method to Save Energy from the Adsorption Dryer in the Process of Purifying Compressed Air (고순도 압축공기 제조시스템의 흡착식 Dryer에서 에너지절감을 위한 운전방법에 관한 연구)

  • Kang, Seok-Wan;Chang, Sung-Ho;Kim, Hyeon-Joon;Kim, Sung-Soo;Lee, Yeong-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.180-191
    • /
    • 2016
  • Optimizing energy usage for maximum efficiency is an essential goal for manufacturing plants in every industrial manufacturing sector. The generation and distribution of purifying compressed air is a large expense incurred in practically all manufacturing processes. Not only is the generation and treatment expensive equipment of compressed air, but frequent maintenance and effective operation is also required. As a plant's compressed air system is often an integral part of the production process, it needs to be reliable, efficient, and easy to be maintain. In this paper, we study to find operating method to save energy from the adsorption dryer in the process of purifying compressed air, which is required for a clean room production site in "A" company. The compressed air passes through a pressure vessel with two "towers" filled with a material such as activated alumina, silica gel, molecular sieve or other desiccant material. This desiccant material attracts the water from the compressed air via adsorption. As the water clings to the desiccant, the desiccant particle becomes saturated. Therefore, Adsorption dryer is an extremely significant facility which removes the moisture in the air $70^{\circ}C$ below the dew point temperature while using a lot of energy. Also, the energy consumption of the adsorption dryer can be varied by various operating conditions (time, pressure, temperature, etc). Therefore, based on existing operating experiments, we have searched operating condition to maximize energy saving by changing operating conditions of the facility. However, due to a short experiment period (from September to October), further research will be focused on considering seasonality.

Study on the Estimation of Frost Occurrence Classification Using Machine Learning Methods (기계학습법을 이용한 서리 발생 구분 추정 연구)

  • Kim, Yongseok;Shim, Kyo-Moon;Jung, Myung-Pyo;Choi, In-tae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.86-92
    • /
    • 2017
  • In this study, a model to classify frost occurrence and frost free day was developed using the digital weather forecast data provided by Korea Meteorological Administration (KMA). The minimum temperature, average wind speed, relative humidity, and dew point temperature were identified as the meteorological variables useful for classification frost occurrence and frost-free days. It was found that frost-occurrence date tended to have relatively low values of the minimum temperature, dew point temperature, and average wind speed. On the other hand, relatively humidity on frost-free days was higher than on frost-occurrence dates. Models based on machine learning methods including Artificial Neural Network (ANN), Random Forest(RF), Support Vector Machine(SVM) with those meteorological factors had >70% of accuracy. This results suggested that these models would be useful to predict the occurrence of frost using a digital weather forecast data.

Humidification Characterization of water-to-gas Membrane Humidifier for Polymer Electrolyte Membrane Fuel Cell (고분자 전해질 연료전지용 water-to-gas 막 가습기의 투과 특성)

  • Chang, Dae-Kwon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.326-334
    • /
    • 2010
  • In this study, characterization and performance of membrane humidifier using membrane distillation was evaluated for moisture of fuel gas in the PEMFC. The data were expressed dew point. The best results show $51.19^{\circ}C$ at $60^{\circ}C$ of water temperature, $54.22^{\circ}C$ at 900 mL/min and $60.03^{\circ}C$ at 100 strands. The mass transfer modelling of membrane humidifier were able to predict humidification of fuel gases for operating PEMFC. When the membrane humidifier was applied to the 100 W stack, it showed stable voltage and power. The volume of membrane humidifier was small however, showed better performance than bubble humidifier.

A Study on the Characteristics of Antecedent Meteorologic Conditions on High Ozone Days in Busan (부산지역 고농도 오존일의 선행 기상 특성 연구)

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.993-1001
    • /
    • 2015
  • Comparing to the other air pollutants like $SO_2$, CO, the number of exceedance of the ozone national ambient air quality standard(NAAQS) and the ozone warning increased recently in Busan. The purpose of this study is to find out the preliminary symptoms for high ozone days in Busan area. In order to find out the preliminary symptoms, the hourly ozone data at air quality monitoring stations and the hourly meterological parameters at Busan regional meteorological 2007 to 2013 were used for the analysis. Averaged daily max ozone concentration was the highest(0.055 ppm) at Noksan and Youngsuri in the ozone season from 2007 to 2013. The horizontal distributions of daily max. ozone including all stations in Busan at high ozone days(the day exceeding 0.1 ppm of ozone concentration at least one station) were classified from two to five clusters by hierarchial cluster analysis. The meteorological variables showing strong correlation with daily max. ozone were the daily mean dew point temperature, averaged total insolation, the daily mean relative humidity and the daily mean cloud amount. And the most frequent levels were $19-23^{\circ}C$ in dew point temperature, $21-24 MJ/m^2$ in total insolation on the day before, $2.6-3.0 MJ/m^2$ on the very day, 67-80% in relative humidity and 0-3 in cloud amount.

Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler (지역난방 첨두부하보일러 대류부 부식 파손 분석)

  • Kim, Youngsu;Chae, Hobyung;Hong, Minki;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

Analysis of Electrochemical Corrosion Resistance of Inconel 625 Thermal Spray Coated Fin Tube of Economizer (Inconel 625 용사코팅된 절탄기 핀튜브의 전기화학적 내식성 분석)

  • Park, Il-Cho;Han, Min-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.187-192
    • /
    • 2021
  • In this study, Inconel 625 was used as a thermal spray material to prevent dew point corrosion damage to the economizer tube, and sealing treatment was performed after applying the arc thermal spray coating technology. Various electrochemical experiments were conducted in the 0.5 wt% sulfuric acid solution to analyze the corrosion resistance of the thermal spray coating (TSC) layer. After the anodic polarization experiment, the degree of corrosion damage was determined through a scanning electron microscope and EDS component analysis. When measuring the open circuit potential, the effect of the sealing treatment was confirmed through stable potential formation of the TSC+sealing treatment (TSC+Sealing). As a result of the anodic polarization experiment, the passivation region was confirmed in TSC and TSC+Sealing, and corrosion resistance was improved as no corrosion damage was observed. In addition, the corrosion resistance of TSC+Sealing was the best when analyzing the corrosion potential and corrosion current density calculated by Tafel analysis.

Comparisons of Collection 5 and 6 Aqua MODIS07_L2 air and Dew Temperature Products with Ground-Based Observation Dataset (Collection 5와 Collection 6 Aqua MODIS07_L2 기온과 이슬점온도 산출물간의 비교 및 지상 관측 자료와의 비교)

  • Jang, Keunchang;Kang, Sinkyu;Hong, Suk Young
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.571-586
    • /
    • 2014
  • Moderate Resolution Imaging Spectroradiometer (MODIS) provides air temperature (Tair) and dew point temperature (Tdew) profiles at a spatial resolution of 5 km. New Collection 6 (C006) MODIS07_L2 atmospheric profile product has been produced since 2012. The Collection 6 algorithm has several modifications from the previous Collection 5 (C005) algorithm. This study evaluated reliabilities of two alternative datasets of surface-level Tair and Tdew derived from C005 and C006 Aqua MODIS07_L2 (MYD07_L2) products using ground measured temperatures from 77 National Weather Stations (NWS). Saturated and actual vapor pressures were calculated using MYD07_L2 Tair and Tdew. The C006 Tair showed lower mean error (ME, -0.76 K) and root mean square error (RMSE, 3.34 K) than the C005 Tair (ME = -1.89 K, RMSE = 4.06 K). In contrasts, ME and RMSE of C006 Tdew were higher than those (ME = -0.39 K, RMSE = 5.65 K) of C005 product. Application of ambient lapse rate for Tair showed appreciable improvements of estimation accuracy for both of C005 and C006, though this modification slightly increased errors in C006 Tdew. The C006 products provided better estimation of vapor pressure datasets than the C005-derived vapor pressure. Our results indicate that, except for Tdew, C006 MYD07_L2 product showed better reliability for the region of South Korea than the C005 products.

An Experimental Study of Frost Formation on the Horizontal Cylinder (수평 실린더 표면의 착상에 대한 실험적 연구)

  • Paik, Sang-Jin;Lee, Yoon-Been;Ro, Sung-Tack
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF

A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process (실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구)

  • Lee Hung Joo;Kim Yong Ku
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF