• Title/Summary/Keyword: Dew

Search Result 314, Processing Time 0.024 seconds

Fatigue Behavior of Catenary Wires by Environments Degradation (환경열화에 의한 가선재의 피로거동)

  • 김용기;장세기
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.14-19
    • /
    • 2004
  • The effect of surface damage on fatigue properties of catenary wires were investigated to estimate their service lift. As surface defects of the wires caused by surface corrosion increase, surface roughness gets worse, and as roughness increases, it is easy for moisture coming from rain and dew to be condensed around uneven parts of the surface. The condensed moisture causes a locally severe corrosion which leads to damage of the wires. Corrosion of catenaty wires can make their actual lifetime shorter than that originally designed. The amount of decrease was more prominent as environmental conditions became more corrosive. They are also vibrated with some amplitude everytime pantographs touch contact line. The frequent cyclic load on the wire may result in a fatigue fracture. Surface damage by corrosion can make formation of crack initiation at fatigue. In the present study, the fatigue life of the used wire was measured 35 to 50% compared with that of new one in average.

Economic Study on Heating load by Balcony Remodeling in use of Energy Simulation Program (에너지 시뮬레이션을 이용한 발코니 개조에 따른 난방부하 경제성 고찰)

  • Kim, Sung-Woo;Park, Sang-Hyun;Lim, Jung-Hee;Kim, Byung-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.801-806
    • /
    • 2006
  • Balcony space effects indoor thermal environment. When balcony is extended, problems would be made such as noise, dew condensation, over heating energy, and etc. Extend of balcony increase heating load about 47%. occupants must consider remodeling for their balcony. This paper compare extended balcony with unextended balcony on heating load in use of energy simulation program. According to increase heating load, we expected that building heating cost would be increased by extend balcony. To consider extend balcony, occupants must be funished with better date between healing cost increasing and floor area increasing.

  • PDF

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture (R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동)

  • Lee, Ji-Sung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process (실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구)

  • Lee Hung Joo;Kim Yong Ku
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF

Effects of Scatter Correction on the Assessment of Myocardial Perfusion and Left Ventricular Function by gated Tc-99m Myocardial SPECT (게이트 Tc-99m 심근관류 SPECT에서 산란보정이 심근관류 및 좌심실기능평가에 미치는 영향)

  • Jeong, Hwan-Jeong;Son, Hye-Kyung;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • Purpose: The purpose of this study was to evaluate the effect of scatter correction on the assessment of myocardial perfusion and left ventricular function by gated Tc-99m myocardial SPECT. Materials and Methods: Subjects were 11 normal volunteers, 20 patients with non-cardiac chest pain and 13 patients with coronary artery diseases. We classified above 3 groups into normal and diseased groups. Scatter correction was done using dual-energy-window scatter correction method (DEW-SC). We compared acquired counts, image contrast, corrected maximum relative counts, indices of left ventricular function, extent and severity of perfusion defects calculated by 'CEqual program' between scatter non-corrected and corrected images. Results: Scatter corrected studios was lower in counts by $18{\pm}3%$ than uncorrected studies, but image contrast were improved in all cases. Scatter correction using DEW-SC took 3 minutes to complete, and 512 kB memory to store. There were no significant differences among indices of left ventricular function between scatter non-corrected and corrected images. Although extents of perfusion defects were not significantly different, severity was severer in scatter corrected images. Conclusion: Scatter correction using DEW-SC is simple to do, and improves image contrast without changing other indices of myocardial perfusion and function.

  • PDF

Estimation of the Moisture Maximizing Rate based on the Moisture Inflow Direction : A Case Study of Typhoon Rusa in Gangneung Region (수분유입방향을 고려한 강릉지역 태풍 루사의 수분최대화비 산정)

  • Kim, Moon-Hyun;Jung, Il-Won;Im, Eun-Soon;Kwon, Won-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.9
    • /
    • pp.697-707
    • /
    • 2007
  • In this study, we estimated the PMP(Probable Maximum Precipitation) and its transition in case of the typhoon Rusa which happened the biggest damage of all typhoons in the Korea. Specially, we analysed the moisture maximizing rate under the consideration of meteorological condition based on the orographic property when it hits in Gangneung region. The PMP is calculated by the rate of the maximum persisting 12 hours 1000 hPa dew points and representative persisting 12 hours 1000 hPa dew point. The former is influenced by the moisture inflow regions. These regions are determined by the surface wind direction, 850 hPa moisture flux and streamline, which are the critically different aspects compared to that of previous study. The latter is calculated using statistics program (FARD2002) provided by NIDP(National Institute for Disaster Prevention). In this program, the dew point is calculated by reappearance period 50-year frequency analysis from 5% of the level of significant when probability distribution type is applied extreme type I (Gumbel distribution) and parameter estimation method is used the Moment method. So this study indicated for small basin$(3.76km^2)$ the difference the PMP through new method and through existing result of established storm transposition and DAD(Depth-Area-Duration). Consequently, the moisture maximizing rate is calculated in the moisture inflow regions determined by meteorological fields is higher $0.20{\sim}0.40$ range than that of previous study. And the precipitation is increased $16{\sim}31%$ when this rate is applied for calculation.

Comparing Net CO2 Uptake of Schlumbergera truncata 'Pink Dew' Phylloclades in a Growth Chamber and a Greenhouse (생육상과 온실에서 게발선인장 '핑크듀'의 엽상경별 CO2 흡수율 비교)

  • Seo Hee Jung;Ah Ram Cho;Yoon Jin Kim
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.64-71
    • /
    • 2023
  • Crassulacean acid metabolism (CAM) plants use surplus CO2 generated by cooling and heating at night when ventilation is not needed in a greenhouse. Schlumbergera truncata 'Pink Dew' is a multi-flowering cactus that needs more phylloclades for high-quality production. This study examined photosynthetic characteristics by the phylloclade levels of S. truncata in a growth chamber and a greenhouse for use of night CO2 enrichment. The CO2 uptake rate of the S. truncata's top phylloclade in a growth chamber exhibited a C3 pattern, and the second phylloclade exhibited a C3-CAM pattern. The CO2 uptake rate of the top phylloclade in a greenhouse showed a negative value both day and night, but those of the second phylloclade exhibited a CAM pattern. The stomatal conductance and water-use efficiency (WUE) of S. truncata at both the top and second phylloclades were higher in a growth chamber than in a greenhouse. The WUE of S. truncata in a growth chamber and a greenhouse was higher at the second phylloclade, which is a CAM pattern compared with those of the top phylloclade. The daily total net CO2 uptake of S. truncata was higher in a growth chamber than in a greenhouse. The daily total net CO2 uptake of S. truncata at the second phylloclade had the highest value of 155 mmol·m-2·d-1 in a growth chamber. The night total CO2 uptake of S. truncate at the second phylloclade was 3-fold higher in a growth chamber than in a greenhouse. S. truncata's second phylloclade exhibited a CAM pattern that uptake CO2 at night, and the second phylloclade, was more mature than the top phylloclade. A multi-flowering cactus S. truncata 'Pink Dew' efficiently uptake night surplus CO2 in the proper environmental condition with matured phylloclade.

A Study on Frost Occurrence Estimation Model in Main Production Areas of Vegetables (채소 주산지에 대한 서리발생예측 연구)

  • Kim, Yongseok;Hur, Jina;Shim, Kyo-Moon;Kang, Kee-Kyung
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.606-612
    • /
    • 2019
  • In this study, to estimate the occurrence of frost that has a negative effect on th growth of crops, we constructed to the statistical model. We factored such various meteorological elements as the minimum temperature, temperature at 18:00, temperature at 21:00, temperature at 24:00, average wind speed, wind speed at 18:00, wind speed at 21:00, amount of cloud, amount of precipitation within 5 days, amount of precipitation within 3 days, relative humidity, dew point temperature, minimum grass temperature and ground temperature. Among the diverse variables, the several weather factors were selected for frost occurrence estimation model using statistical methods: T-test, Variable importance plot of Random Forest, Multicollinearity test, Akaike Informaiton Criteria, and Wilk's Lambda values. As a result, the selected meteorological factors were the amount of cloud, temperature at 24:00, dew point temperature, wind speed at 21:00. The accuracy of the frost occurrence estimation model using Random Forest was 70.6%. When it applied to the main production areas of vegetables, a estimation accuracy of the model was 65.2 and 78.6%.

Conservation Environmental Assessment and Microbial Distribution of the Songsan-ri Ancient Tombs, Gongju, Korea (공주 송산리 고분 내 미생물 분포 및 보존환경 연구)

  • Lee, Min Young;Kim, Dae Woon;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.30 no.2
    • /
    • pp.169-179
    • /
    • 2014
  • After occurrence of Cyanobacteria in 1997, Songsan-ri tombs located in Gonju have been investigated to monitor for biological damage. The room temperature of Tomb No.6 was $18.6{\sim}19.8^{\circ}C$ and the relative humidity was 94.3~99.9%. The temperature of Royal Tomb of King Muryeong was $17.3{\sim}18.53^{\circ}C$ and the relative humidity was 73.2~96.45%. The variation of relative humidity increased after setting up air vents. If the outside temperature increases, dew condensation occurs on the floor and the north side. When conditioning equipment operates, the maximum temperature differences between walls is $2.8^{\circ}C$. Bacteria from the air of the tomb and on the surface of the walls outnumbered fungi. 20 species of fungi including Alternaria sp., Aspergillus sp., Penicillium sp., and 19 species of bacteria including Pseudomonas sp., Arthrobacter sp., are identified. Microbes in the tombs may damage cultural heritage. The growth possibility of microbes should be estimated because the microbes in the tombs may damage mural painting. The interrelation between microenvironmental condition and biological damage of mural painting should be researched to come up with an long-term conservation method.