• 제목/요약/키워드: Dew

검색결과 314건 처리시간 0.03초

예지고, 시간경과, 롤링과 이슬제거가 골프 코스 퍼팅 그린의 그린 스피드에 미치는 영향 (The effect of mowing height, time lapse, rolling, and dew removal on green speed of putting green in Golf Course)

  • 심경구;이상재;허근영
    • 아시안잔디학회지
    • /
    • 제13권3호
    • /
    • pp.139-146
    • /
    • 1999
  • This studies was carried out to estimate the influence of mowing height, time lapse, rolling, and dew removal on green speed of putting green in Lake Side C. C. on 29, 30 Jun. 1998. The results were as follows. As mowing height increased, green speed tended to be decreased. After mowing, green speed tended to be decreased over the time, and appeared to be decrease significantly on the next day[Y=3.206-0.127.X1-1.41$\times$10-2.X4(Y=green speed, X1=mowing height, X4=time lapse)]. This suggests that the frequency of mowing must be increased to maintain the green speed. But, frequent mowing cause the turfgrass of putting green to be stressed. Rolling tended to increase green speed[Y=3.555-0.202.X1+0.111.X2(Y=green speed, X1=mowing height, X2=rolling)]. Thus, rollers is thought to be an tool used to increase green speed and rolling is expected to be able to decrease turfgrass stress while maintaining the performance level of the putting green. Dew removal appeared to increase green speed significantly[Y=2.499-0.125.X1+0.366.X3(Y=green speed, X1=mowing height, X3=dew removal)]. Thus, dew removal is expected to maintain the green speed in the morning.

  • PDF

결로 발생 도로표지가 운전자에게 미치는 영향에 관한 연구 (Study of the Influence of Condensation on Road Signs to Drivers)

  • 박재홍;윤덕근;성정곤;강원의
    • 한국도로학회논문집
    • /
    • 제15권5호
    • /
    • pp.187-193
    • /
    • 2013
  • PURPOSES : This research is to analyze the influence in terms of misreading rate and legibility time for drivers when condensation occurs on the road signs. METHODS : In this research, the dew occurred road signs provided to drivers to measure legibility time and misreading rate to compare with normal road sign. In order to identify the difference of legibility time between normal road sign and dew occurred road sign, the T-test and ANOVA test were used. And the vision system was used to recognize the region of dew occurrence on the road sign, then the brightness of dew occurrence region on the road sign was changed to check the misreading rate of drivers according to the change rate of brightness. RESULTS : The legibility times were measured 2.65s for normal road sign and 4.08s for dew occurrence road sign and misreading rates were measured 2.8% for normal road sign, 21.7% for dew occurrence road sign.

발전소 공기예열기 소재의 배기가스 농도 및 온도에 따른 내식성 및 노점 분석 (Analysis of Corrosion Resistance and Dew Point with Exhaust Gas Concentration and Temperature for Air Preheater Materials in Power Plants)

  • 이승준
    • Corrosion Science and Technology
    • /
    • 제22권5호
    • /
    • pp.351-358
    • /
    • 2023
  • Although many thermal power plants use heat recovery systems, high exhaust gas temperatures are maintained due to corrosion at dew points and ash deposits caused by condensate formation. The dew point of exhaust gas is primarily determined by the concentration of SO3 and steam, and various experiments and calculation equations have been employed to estimate it. However, these methods are known to be less suitable for exhaust gases with low SO3 concentrations. Therefore, in this study, since the temperature of the exhaust gas is expected to decrease due to the low-load operation of the coal-fired power plant, sulfuric acid condensation and low-temperature corrosion are anticipated. We aimed to conduct a quantitative evaluation to propose ways to prevent damage by limiting operating conditions and improving facilities. The experimental results showed that the corrosion rate increased linearly with rising temperatures at a certain sulfuric acid concentration. Furthermore, variations in sulfuric acid concentrations generated during the current power plant operation process did not significantly affect the dew point, and the dew point of sulfuric acid under these conditions was observed to be between 120 - 130 ℃.

Factors Affecting Sporulation, Germination, and Appressoria Formation of Epicoccosorus nematosporus as a Mycoherbicide Under Controlled Environments

  • Hong, Yeon-Kyu;Cho, Jae-Min;Lee, Bong-Choon;Uhm, Jae-Youl;Kim, Soon-Chul
    • The Plant Pathology Journal
    • /
    • 제18권1호
    • /
    • pp.50-53
    • /
    • 2002
  • To develop Epicoccosorus nematosporus as a mycoherbicide of Eleocharis kuroguwai, the optimum temperature and humidity for sporulation of the pathogen were studied. Conidial production was most abundant at $28^{\circ}C$ with RH 60%, which yielded 661 mg in 9 cm Petri dish. Light intensity of 3,000 up to 7,500 lux was effective in stimulating conidial production of E. nematosporus on oatmeal agar, Light intensity affected sporulation more significantly than temperature. In the pot test, at least 12 h of dew period at $20^{\circ}C$ and $25^{\circ}C$ was required to achieve satisfactory conidial germination and appressorial formation. Few were killed at 8 h of dew period regardless of temperature. Sixteen hours of a single dew treatment immediately after inoculation killed more plants than did two or three repetitive dew treatments of 8-12 h.

On/Off 제어에 의한 습도와 결로의 제어에 관한 연구 (A Study on The Control of Humidification and Dew Condensation by On/Off Control)

  • 박대흠;김두희;김경훈;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.835-841
    • /
    • 2011
  • The humidification is essential for performance enhancement of the electrolysis of PEMFC because proton conductivity depends on hydration of the proton exchange membrane. In this study, the humidification experiment did about On/Off control the humidification and dew condensation for PEMFC by using of the membrane humidifiers. As the results, it was possible to approximation control of the humidity by using of the solenoid valve On/Off control on the membrane humidifier. Also the problem on the dew condensation was resolved by approximation humidity control through solenoid valve On/Off control and the removal of the dew condensation in the flow channel was verified through visualization experiment.

수정미소저울 노점센서 제작 및 반응특성 연구 (Development of QCM dew point sensor and its sensing characteristics study)

  • 권수용;김종철;최병일
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.269-276
    • /
    • 2006
  • This paper represents development of quartz crystal microbalance (QCM) and usage as a dew point sensor. The temperature of a quartz resonator was controlled precisely from $20^{\circ}C$ to $-30^{\circ}C$ with the ramping rate of $0.1^{\circ}C/s$ by using a custom-made crystal holder housing the quartz resonator associated with a thermoelectric cooler (Peltier cooler), which results in the working range from $15.2^{\circ}C$ to $-24.0^{\circ}C$ based on an accurate holder temperature compensation and temperature effect compensation process. The developed QCM dew point sensor and analysis techniques show very good sensing characteristics at measurement of moist air with the relative humidity from 10 %R.H. to 90 %R.H. generated by a divided-type humidity generator and the dew point temperatures were determined with an accuracy of less than ${\pm}0.18^{\circ}C$, which also showed good agreement with reference values in their error range.

실내수영장의 열, 기류 및 습도환경에 관한 연구 (A Study of Thermal, Air-flow and Humidity Conditions in an Indoor Swimming Pool)

  • 강석윤;이태구;문종선;이재헌
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.683-689
    • /
    • 2003
  • The thermal comfort of an indoor swimming pool is different from that of general indoor space because of the characteristics of large space and the wear conditions of swimmers. Dew condensation by humid air not only makes mold on the floor, wall and roof but also decreases the durability of buildings by penetrating into their structures. In this study, the characteristics of the flow field, the temperature field and the humidity distribution in an indoor swimming pool have been examined by the numerical method to estimate the level of thermal comfort and the generation rate of dew condensation. The results showed that the dew condensation regions were spread widely at the eastern parts of the swimming pool due to the insufficient air flow rate with low velocity and temperature. To prevent the generation of dew condensation in a region, a sufficient warm air flow rate should be supplied to make an air mixing. The values of PMV at horizontal plane of 1.5 m height have the range of -1.0∼1.2, which means the suitable level for swimmers.

발전소 절탄기 튜브의 배기가스 온도와 황산 농도에 따른 노점 및 내식성 분석 (Analysis of dew point and corrosion resistance for power plant economizer tube with exhaust gas temperature and sulfuric acid concentration)

  • 최재훈;이승준
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.433-440
    • /
    • 2022
  • Environmental pollution caused by power plant exhaust gas is highlighted and eco-friendly regulations are being strengthened. However, due to the abundant reserves and low prices of coal, still the most used for power generation in the world. Therefore, flexible operation of coal-fired power plants to reduce emissions has become an inevitable option. However, lowering the output increases the possibility of acid dew point corrosion as the exhaust gas temperature decreases. The dew point corrosion occurs when condensable gases such as SO3, HCl, NO2 and H2O cools below the saturation temperature. SO3 is already well known to cause severe low- temperature corrosion in coal-fired power plants. Therefore, this study aims to prevent damage that may occur during operation by analyzing the dew point and corrosion resistance with exhaust gas temperature and sulfuric acid concentration of the power plant economizer tube.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF