• 제목/요약/키워드: Device-free

검색결과 669건 처리시간 0.03초

전자뜸의 적정 시술시간에 대한 연구 -피부 안전성 중심- (A Study on the Proper Treatment Time of Electronic Moxibustion - Focusing on the Skin Safety -)

  • 박소윤;황지용;이병욱;이봉효
    • Korean Journal of Acupuncture
    • /
    • 제35권1호
    • /
    • pp.36-40
    • /
    • 2018
  • Objectives : Electronic moxibustion was developed to overcome the weakness of conventional moxibution. However, in spite of many benefits, it also can not be entirely free from the concern of burning. This study was performed to investigate the proper treatment time of electronic moxibustion. Methods : Male sprague-Dawley rats weighing about 350 g were used. Animals were anesthetized with sodium pentobarbital and shaved on the abdomen or back. The full charged-electronic moxibustion device was placed on the shaved site and it was observed if there happened any adverse event after treatment. Results : At the temperatures of 41, 43, and $45^{\circ}C$ there was no abnormal sign after moxibustion even in full time. However, at $47^{\circ}C$, the safe treatment time was 3 min. On the other hand, $49^{\circ}C$ produced diverse adverse events even in 1 min. Conclusions : Results of the present study suggest that the safe treatment time of electronic moxibustion is different according to the temperature. The most common adverse effect in this electronic moxibustion was the white spot and it is needed to observe whether there is any adverse event until 48 h after treatment.

3차원 공간상의 수신호 인식 시스템에 대한 연구 (A Study on Hand-signal Recognition System in 3-dimensional Space)

  • 장효영;김대진;김정배;변증남
    • 전자공학회논문지CI
    • /
    • 제41권3호
    • /
    • pp.103-114
    • /
    • 2004
  • 본 논문은 3차원 공간상에서 행해지는 수신호들을 인식하는 시스템을 다룬다. 수신호 입력을 위한 장치로는 두 대의 컬러카메라를 사용한다. 비전에 기반을 둔 제스처 인식 방식은 그 자체의 비접촉식 특성으로 인해 사용자 편의 면에서 우수한 것으로 알려져 있다. 그러나 여타의 카메라를 입력 장치로 사용하는 방식들이 그러하듯이 배경과 조명 변화에 대해 취약하다는 것이 문제시된다. 본 논문에서는 특수한 장갑이나 표식을 사용하지 않고도, 배경 및 조명 변화에 강인하게 입력 영상에서 손영역을 검출하기 위해, 적응 손 컬러 모델과 함께 이전 위치 정보를 이용하였다. 손 영역 영상으로부터 수신호를 인식하기 위해서, 본 논문은 '손 자세'와 '손 궤적'을 기본요소로 하는 수신호 정의 방식을 바탕으로 한다. 확장성 있는 손 자세 분류를 위해서 소그룹 개념을 통한 2단계의 분류방식을 제안한다. 3차원 수신호 영상을 얻기 위해 사용된 두 대의 카메라로부터 얻은 영상들에 대한 상호보완적 선택 방법도 제시한다. 제안된 수신호 인식 방법은 차량 주행 시뮬레이터에 적용하여 실제 환경에서의 적용 가능성을 검증하였다.

휴대폰 애프터서비스 품질이 고객만족과 고객충성도에 미치는 영향 (The Influence of After-Sales Service Quality on Customer Satisfaction and Loyalty in Mobile Phone)

  • 이재준;유지현;이세재;오현승;조진형
    • 산업경영시스템학회지
    • /
    • 제40권4호
    • /
    • pp.87-95
    • /
    • 2017
  • This study aims to configure what dimensions make up for smart phone after service quality, and how this service quality affects customer satisfaction and customer loyalty. Smart phone market is a market of the device leading the digital convergence as well as positioning itself as one of the national growth driving industry. To survive in this matured market, companies should have to respond actively to radical changes and customers needs in the so-called Smart Revolution environment. Lately, however, the smart phone market is prospected to move from growth phase to mature phase by the scholars. In order to proactively respond to the change in such market condition, companies need to provide absolute advantage in customer loyalty over their competitors by revolutionizing the after-sales service quality. Qualified A/S will lead to service satisfaction and achieve customer loyalty. The empirical analysis results obtained through A/S quality are as follows : First, human quality (attitude, expertise, problem-solvability), environment quality (handling agility, convenience, comfort), service policy quality (quality guarantee, additional service operation) are dimensions that make up for A/S quality. Second, A/S quality dimension showed a significant positive influence on service satisfaction and A/S satisfaction showed a positive influence on customer loyalty as well. Based on this empirical study, we propose some implications for A/S quality improvement. First, human quality dimension has relatively higher influence on A/S satisfaction in case of free A/S, so companies need to solve the product problem completely when consumer's first visit by continual employee education. Second, in case of paid A/S, the service policy quality-especially A/S Warranty period- has higher influence on A/S satisfaction.

치과용 지혈제가 상아질 투과도에 미치는 영향 (THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY)

  • 김종현;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

[NiFe/NiFeCuMo/NiFe]/FeMn 다층박막의 교환결합력과 보자력에 관한 특성 연구 (Exchange Bias Field and Coercivity of [NiFe/NiFeCuMo/NiFe]/FeMn Multilayers)

  • 최종구;이상석
    • 한국자기학회지
    • /
    • 제21권4호
    • /
    • pp.132-135
    • /
    • 2011
  • 초연자성을 갖는 코네틱(NiFeCuMo) 박막을 NiFe 박막 사이에 삽입한 삼층박막 위에 반강자성체 FeMn을 증착한 다층박막에서 NiFe와 NiFeCuMo 박막의 두께에 따른 교환결합력과 보자력에 관한 특성을 조사하였다. 특히 NiFeCuMo 박막의 두께가 1 nm일 때 NiFe 박막 사이에 삽입한 삼층박막 위에 반강자성체 FeMn을 증착한 다층박막의 교환결합력은 최댓값을 나타내었다. 고정층과 자유층에 각각 NiFeCuMo 박막을 삽입하여 초연자성의 바이오센서용 거대자기저항-스핀밸브(giant magnetoresistive-spin valves; GMR-SV) 소자를 개발할 수 있는 가능성을 보여주었다.

실리콘 결정면을 이용한 LCD-BLU용 도광판의 미세산란구조 형성 (Micro-patterning of light guide panel in a LCD-BLU by using on silicon crystals)

  • 최가을;이준섭;송석호;오차환;김필수
    • 한국광학회지
    • /
    • 제16권2호
    • /
    • pp.113-120
    • /
    • 2005
  • LCD-BLU(liquid crystal device-back light unit)에 사용되는 도광판의 미세 산란패턴을 만드는 새로운 방법으로서, 실리콘 웨이퍼의 비등방 식각에 의해 자연적으로 형성되는 3차원 결정면 구조를 이용하는 방법을 제안하였다. 실리콘 3차원 결정면을 갖는 도광판과 프리즘 시트의 원판을 설계 및 제작하였고, casting 공정을 통해 PDMS 재질로 복제된 도광판을 제작하여 특성을 분석하였다. 측정 결과, 기존 인쇄형 도광판에 비해 실리콘피라미드 패턴의 도광판이 $10\%$ 증가된 정면 휘도 효율을 가질 수 있음을 실험적으로 검증하였다.

시간 제약 조건과 면적을 고려한 효율적인 CPLD 기술 매핑 (An Efficient CPLD Technology Mapping considering Area and the Time Constraint)

  • 김재진;이관형
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권3호
    • /
    • pp.11-18
    • /
    • 2005
  • 본 논문에서는 시간제약 조건하에서 면적을 고려한 CPLD 기술매핑 알고리즘을 제안한다. 본 기술매핑 알고리즘은 주어진 EDIF나 부울식의 불린 네트워크에서 궤환을 검출한 후 궤환이 있는 변수를 임시 입력 변수로 분리하여 DAG로 표현한 후 노드를 검색한 후 팬 아웃 프리 트리로 재구성한다. 시간제약 조건과 소자의 지연시간을 이용하여 그래프 분할이 가능한 다단의 수를 결정하여 매핑 가능 클러스터를 구성한다. 콜랍싱(collapsing)을 통해 노드들을 병합하고, 주어진 소자의 CLB안에 빈 패킹(Bin packing)를 수행하였다. 본 논문에서 제안한 기술매핑 알고리즘을 MCNC 논리합성 벤치마크 회로들에 적용하여 실험한 결과 DDMAP에 비해 $62.6\%$의 논리블록의 수가 감소되었고, TEMPLA에 비해 $17.6\%$ 감소되었다.

  • PDF

Piezo Sensor Signal에 의한 수면의 질 Algorithm에 관한 연구 (A Study on Sleep Quality Algorithm by Piezo Sensor Signal)

  • 변재령;조위덕;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.324-326
    • /
    • 2011
  • 수면 중 생체 신호를 측정하는 것은 수면 장애 진단 및 치료의 중요한 부분을 차지하며, 전반적인 수면의 질을 판단하는 방법으로 사용되고 있다. 현재 수면다원검사와 같이 수면중 생체 신호를 측정하는 방법은 몸에 전극을 부착하는 접촉식 방법이 사용되고 있다. 이는 수면 중 움직임에 제약을 받고, 매 측정 시 마다 탈부착을 해야 하는 번거러움과 고통을 유발하게 된다. 이러한 필요성으로 인해 무구속적 방식으로 생체 정보를 획득하려는 연구가 활발히 진행되고 있는 상태이다. 따라서 본 논문에서는 필름 타입의 압력센서인 피에조 (Piezo)를 침대에 설치하여 직접적인 접촉과 구속감이 없이 분당 심박 수를 산출하고, 호흡의 유무를 판단하는 방법에 대해 제안하였다.

  • PDF

Wi-Fi AP와 FMC에 대한 무선 호 가로채기 공격 분석 연구 (A Study of Registration Hijacking Attack Analysis for Wi-Fi AP and FMC)

  • 천우성;박대우;장영현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.261-264
    • /
    • 2011
  • 유선전화에서 무선전화로 전화사용 추세가 전환되면서, 무료 와이파이(Wi-Fi) 기능이 탑재된 휴대폰, 넷북 등 모바일 기기가 빠르게 확산되고 있다. 하지만 무선 인터넷전화는 기존 인터넷망을 이용하여 통화내용을 전달하기 때문에 인터넷서비스가 가지고 있는 취약점이 발생하게 된다. 행정기관에서 사용하고 있는 인터넷전화도 현재 유선에서 무선으로 연결 및 사용률이 증가되고 있다. 본 논문에서는 기존 무선인터넷의 취약점이 발견되는 Wi-Fi AP와 FMC같은 행정기관 인터넷전화 무선 장비에 대한 취약점을 연구를 한다. Wi-Fi AP와 FMC에 대한 취약점을 분석하고, 인터넷전화의 공격에 기본이 되는 호 가로채기 공격실험과 분석을 한다. 보안성이 강화된 인터넷전화를 위한 Wi-Fi AP와 FMC 호 가로채기 공격에 대한 방어와 보안 대책을 연구한다.

  • PDF

수종의 desensitizing agent가 상아질 투과도에 미치는 영향 (THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON THE PERMEABILITY OF HUMAN DENTIN)

  • 전영의;정일영;윤태철
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.322-329
    • /
    • 1999
  • The hydrodynamic theory of dentin sensitivity states that movement of tubular contents or tubular fluid, in either direction of dentinal tubule, causes dentin sensitivity. A corollary of that theory is that anything that can decrease dentinal fluid movement or dentin permeability should decrease dentin sensitivity. A wide variety of physicochemical methods have been used to reduce the permeability and sensitivity of exposed dentin. The purpose of this study was to evaluate the ability of 4 kinds of clinical desensitizing agents(2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$, Tubulitec system$^{(R)}$) to reduce the rate of fluid flow through dentin in vitro. Sixty coronal dentin discs, 1mm in thickness, were prepared from extracted third molars, free from decay and wear. Dentin discs were treated with 3% EDTA(Tubulicid Plus$^{(R)}$(Dental Therapeutics AB, Sweden)) to remove the smear layer and debris occluding the tubular orifices. After placing the discs in a split chamber device, the rate at which physiologic saline solution could filter across dentin under 150cm $H_2O$ hydrostatic pressure was measured. The occlusal side of the discs were then treated with MS Coat$^{(R)}$, 2% NaF, Tubulitec system$^{(R)}$, and 30% Potassium oxalate, and the filter ratio of the saline solution was measured again. The following conclusions were drawn : 1. Hydraulic conductance which was measured after the application of desensitizing agents was decreased in all the groups(p<0.05). 2. % change of hydraulic conductance was compared but no significant difference was found among the four desensitizing agents(p>0.05). 2% NaF, 30% Potassium oxalate, MS Coat$^{(R)}$ and Tubulitec system$^{(R)}$ decreased the permeability of dentin. It is considered that above four agents can be used in treating the hypersensitive teeth.

  • PDF