• 제목/요약/키워드: Device-free

검색결과 669건 처리시간 0.028초

고온초전도 더블 팬케이크 코일들 사이의 접합 방법 (A Joining Method between HTS Double Pancake Coils)

  • 손명환;심기덕;김석호;김해종;배준한;이언용;민치현;성기철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.633-639
    • /
    • 2006
  • High temperature superconductor (HTS) winding coil is one of the key component in superconducting device fabrication. Double-pancake style coils are widely used for such application. High resistance between pancake coils greatly affects the machine design, operating condition and thus the stability. In order to reduce such resistance, experimentalists are looking for efficient and damage free coil connecting methods. In this respect, here we proposed parallel joining method to connect the coils. This is to do crossly joining with HTS tapes on two parallel HTS tapes. Joint samples between two parallel HTS tapes were prepared by using HTS tapes and current-voltage (I-V) characteristic curves were investigated at liquid nitrogen temperature i.e., 77.3 K. A 20 cm length joint connected between two parallel HTS tapes shows $32.5n{\Omega}$, for currents up to 250 A. A small HTS magnet, having two double pancake sub-coils connected together through new parallel joint method was fabricated and their current-voltage (I-V) characteristic curve was investigated. At 77.3K, critical current(Ic) of 97 A and resistance of $55n{\Omega}$ for currents upto 130 A were measured. At operating current 86 A lower than Ic, Joule heats generated in whole magnet and at joint region between sub-coils were 226 mW and 0.4 mW, respectively. Low Joule heat generation suggests that this joining method may be used to fabricate HTS magnet or windings.

센서 네트워크를 이용한 유비쿼터스 주차관리 시스템의 설계 및 구현 (Design and Implementation of Ubiquitous Parking Management System using Sensor Network)

  • 변창희;이지혜;조현우;김형신
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제13권6호
    • /
    • pp.388-396
    • /
    • 2007
  • 본 연구에서는 센서 네트워크를 이용하여 유비쿼터스 서비스를 제공해 주는 주차관리시스템을 구현하였다. 유비쿼터스 주차 관리 시스템은, 인터넷과 연결된 PDA나 휴대폰 상에서 현재 주차장의 정보를 한눈에 파악하여 빠르게 주차 공간을 확보할 수 있도록 해 준다. 유비쿼터스 주차관리시스템의 구현을 위해서 하드웨어 센서 노드, 센서 어플리케이션, 그리고 웹서버 응용 프로그램을 개발하였다. 제안하는 시스템은 일정주기로 주차공간의 상태를 업데이트 할 뿐만 아니라, 사용자가 원할 때 웹 상에서 버튼을 눌러 현재의 상황을 실시간으로 확인 할 수 있는 양방향 통신기능을 제공한다. 수집된 주차공간 정보는 일정기간 데이타베이스에 저장함으로써, 시간 혹은 공간별 주차 사용시간을 분석할 수 있도록 구현되었다. 본 연구에서 개발한 시스템은 10대 규모의 대학 내 주차장에 실제 설치하였으며, 인터넷 단말기를 통하여 서비스를 제공함으로써 실용성을 확인하였다.

청취자가 이동이 가능한 청각 디스플레이 시스템 개발 (A development of the virtual auditory display system that allows listeners to move in a 3D space)

  • 강대기;이채봉
    • 융합신호처리학회논문지
    • /
    • 제13권1호
    • /
    • pp.1-5
    • /
    • 2012
  • 본 연구에서는 청취자가 3차원 공간에서 자유로이 움직일 수 있는 음장 재생 시스템을 개발하였다. 시스템은 방음실($4.7m(W){\times}2.8m(D){\times}3.0m(H)$)에 설치하였으며 개인용 컴퓨터, 음의 제시장치 그리고 3차원 초음파 센서로 구성하였다. 본 시스템에서는 실내 전체를 감지하는 3차원 초음파 센서로부터 청취자의 위치 정보 및 자세각 정보를 얻어, 컴퓨터에서 나오는 음신호에 머리전달함수(HRTFs)를 삽입하여 음의 제시 장치로부터 출력하도록 설정하였다. 실험에 사용한 머리전달함수는 청취자의 머리 정변에서 1.5m 떨어진 지점에서 각각 측정하였다. 그리고 시스템의 성능을 평가하기 위해 가상 음원의 위치를 랜덤으로 변화시키고, 청취자에게는 자유로운 이동을 허락한 상태에서 음원의 위치를 찾는 실험을 수행하였다. 그 결과, 3차원 공간에 있어서 제시된 음원의 위치에서 청취자가 추정한 위치까지의 거리 오차는 약 30cm 이내로 나타났다.

임피던스 방법을 이용한 체지방 측정 (Measurement of Body Fat by Impedance Technique)

  • 김덕원;송철규;황수관
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.133-140
    • /
    • 1992
  • Bioelectrical Impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat-free mass (FFM) is far greater than that of the (at. Deter- mination o( impedance was nlade in 30 healthy and obese men aged $40.9{\pm}14.7$yr (mean${\pm}$SD) and 25 healthy and obese women aged $44.0{\pm}10.2$ yr. A commercial impedance body fat analyzer was used with a four electrode arrangement that introduced a painless constant current(ImA at 50 kHz) into the body. Linear relationships were found between impudence values and FFM(r=-0.786) and between weight and FFM(r=0.837). Signigicant increases in the correlation coefficients were ob served when the predicator Hta/z was regressed against FFM(r=0.912) where Ht Is height and Z Is impedance. A linear regression equation, FFM=0.586(Htf/z) +0.317(Weight) -1.674(r=0.977), was found. The correlation coefficient of % body fat between the impedance and infrared methods was 0.898. These data Indicate that the bioelectrical impedance technique is a reliable and valld approach for the estimation of human body composition. This method Is safe, noninvasivr, prouides rapld measure menu, requires little operator skill and subject cooperation, and Os portable. Finally measurement of percent body fat was made possible using both the regression equation and a developed impedance measuring device which measures impedance between wrist and ankle.

  • PDF

티타늄의 절삭성에 관한 연구 (A Study on the Machinabilty of Tianium)

  • 홍환표;오석형;서남섭
    • 한국정밀공학회지
    • /
    • 제6권1호
    • /
    • pp.45-51
    • /
    • 1989
  • In metal cutting various types of chips are produced in consequence of cutting conditions. According to the type of chips the cutting mechanism is to be changed. Most of the cutting theory is based on the continuous chip because of its convenient analysis, but the occurrence of the saw-toothed chip depends upon the workpiece and/or the cutting conditions, one of which is titanium alloy used widely. Nowadays titanium alloys are used widely with the rapid development of aerospace structural engineering application, whereas the theory of cutting mechanism has not been established yet, and the formatting process has not been understood satisfactorily, either. Unfortunately several misconceptions, conflicting statements and statements needing further clarifi- cation are also found. In this paper an attempt is made to clarify the formation process of saw-toothed chips which are to be produced during the orthogonal cutting process of titanium alloys. They were machined at low speed to avoid the rapid tool wear. We observed the SEM-photographs of chips taken at the quick-st- opping device. It is hoped that a rational model of the mechanics of cyclic chip formation can be developed. The results obtained are as follows. 1. When a saw- toothed chip is formed, the shear band begins at the primary shear zone and trans- fers to the free surface, so that a segment is produced and it is completed by upsetting between the formatting segment and the formatted segment. 2. As the rake angle or the clearance angle increases in the machining of the titanium alloy, the chip approaches to that of the continous type. 3. When the rake angle and the clearance angle are increased the shear energy and the unit friction energy decrease, which shows the same aspect as that of the continuous chip.

  • PDF

히트싱크의 자연대류 열유동 특성 분석 (Investigation of Natural Convective Heat Flow Characteristics of Heat Sink)

  • 정태성;강환국
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.27-33
    • /
    • 2013
  • 제품의 성능 및 신뢰성 향상을 위하여 효과적이고, 적정한 방열장치의 중요성이 지속적으로 부각되고 있다. 현재 가장 널리 쓰이는 방열장치는 알루미늄 압출식 평행핀 형상의 히트싱크(heat sink)로 이의 설계를 위해서는 방열량과 최대 허용온도 등에 대한 목표가 결정되어야 하며, 사용 환경 및 설치 방법에 따른 열전달 계수의 예측이 이루어져야 한다. 본 연구에서는 히트싱크의 베이스가 수직, 수평상태를 유지함에 따라 나타나는 핀 주변의 자연대류 유동 특성을 전산모사 해석을 통해 고찰하였다. 또한, 일반적인 자연대류형 히트싱크를 대상으로 수평 및 수직상태에서의 열적 성능 실험을 수행하였으며, 기존의 연구결과와 비교함으로써 설치방향이 히트싱크 방열성능에 미치는 영향에 대하여 분석하였다. 실험결과 수평상태의 경우는 수직인 경우에 비하여 약 10~15% 열전달 계수의 감소가 발생하였다.

Advanced Low-k Materials for Cu/Low-k Chips

  • Choi, Chi-Kyu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.71-71
    • /
    • 2012
  • As the critical dimensions of integrated circuits are scaled down, the line width and spacing between the metal interconnects are made smaller. The dielectric film used as insulation between the metal lines contributes to the resistance-capacitance (RC) time constant that governs the device speed. If the RC time delay, cross talk and lowering the power dissipation are to be reduced, the intermetal dielectric (IMD) films should have a low dielectric constant. The introduction of Cu and low-k dielectrics has incrementally improved the situation as compared to the conventional $Al/SiO_2$ technology by reducing both the resistivity and the capacitance between interconnects. Some of the potential candidate materials to be used as an ILD are organic and inorganic precursors such as hydrogensilsequioxane (HSQ), silsesquioxane (SSQ), methylsilsisequioxane (MSQ) and carbon doped silicon oxide (SiOCH), It has been shown that organic functional groups can dramatically decrease dielectric constant by increasing the free volume of films. Recently, various inorganic precursors have been used to prepare the SiOCH films. The k value of the material depends on the number of $CH_3$ groups built into the structure since they lower both polarity and density of the material by steric hindrance, which the replacement of Si-O bonds with Si-$CH_3$ (methyl group) bonds causes bulk porosity due to the formation of nano-sized voids within the silicon oxide matrix. In this talk, we will be introduce some properties of SiOC(-H) thin films deposited with the dimethyldimethoxysilane (DMDMS: $C_4H_{12}O_2Si$) and oxygen as precursors by using plasma-enhanced chemical vapor deposition with and without ultraviolet (UV) irradiation.

  • PDF

Characteristics of Particle Separation in Suspension using an Ultrasonic Standing Wave

  • Shin, Beom-Soo;Danao, Mary-Grace C.
    • Journal of Biosystems Engineering
    • /
    • 제37권2호
    • /
    • pp.113-121
    • /
    • 2012
  • Purpose: Particle separation in solution is one of important process in a unit operation as well as in an extract preparation for biosensors. Contrary to centrifuge-type of mesh-type filter, using an ultrasonic standing wave make the filtering process continuous and free from maintenance. It is needed to investigate the characteristics of particle movement in the ultrasonic standing wave field. Methods: Through the computer simulation the effects of major design and driving parameters on the alignment characteristics of particles were investigated, and a cylindrical chamber with up-stream flow type was devised using two circular-shape PZTs on both sides of the chamber, one for transmitting ultrasonic wave and the other for just reflecting it. Then, the system performance was experimentally investigated as well. Results: The speed of a particle to reach pressure-node plane increased as the acoustic pressure and size of particle increased. The maximum allowable up-stream flow rate could be calculated as well. As expected, exact numbers of pressure-node planes were well formed at specific locations according to the wavelength of ultrasonic wave. As the driving frequency of PZT got close to its resonance frequency, the bands of particles were observed clearer, which meant the particles were trapped into narrower space. Higher excitation voltages to the PZT produced a greater acoustic force with which to trap particles in the pressure-node planes, so that the particles gathered could move upwards without disturbing their alignments even at a higher inlet flow rate. Conclusions: This research showed the feasibility of particle separation in solution in the continuous way by an ultrasonic standing wave. Further study is needed to develop a device to collect or harvest those separated particles.

Reduced graphene oxide field-effect transistor for biomolecule detection and study of sensing mechanism

  • Kim, D.J.;Sohn, I.Y.;Kim, D.I.;Yoon, O.J.;Yang, C.W.;Lee, N.E.;Park, J.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.431-431
    • /
    • 2011
  • Graphene, two dimensional sheet of sp2-hybridized carbon, has attracted an enormous amount of interest due to excellent electrical, chemical and mechanical properties for the application of transparent conducting films, clean energy devices, field-effect transistors, optoelectronic devices and chemical sensors. Especially, graphene is promising candidate to detect the gas molecules and biomolecules due to the large specific surface area and signal-to-noise ratios. Despite of importance to the disease diagnosis, there are a few reports to demonstrate the graphene- and rGO-FET for biological sensors and the sensing mechanism are not fully understood. Here we describe scalable and facile fabrication of rGO-FET with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}1$-antichymotrypsin (PSA-ACT) complex, in which the ultrathin rGO sensing channel was simply formed by a uniform self-assembly of two-dimensional rGO nanosheets on aminated pattern generated by inkjet printing. Sensing characteristics of rGO-FET immunosensor showed the highly precise, reliable, and linear shift in the Dirac point with the analyte concentration of PSA-ACT complex and extremely low detection limit as low as 1 fg/ml. We further analyzed the charge doping mechanism, which is the change in the charge carrier in the rGO channel varying by the concentration of biomolecules. Amenability of solution-based scalable fabrication and extremely high performance may enable rGO-FET device as a versatile multiplexed diagnostic biosensor for disease biomarkers.

  • PDF

광중합 시 수종의 심미적 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VARIOUS ESTHETIC RESTORATIVE MATERIALS AND BASES DURING CURING PROCEDURE)

  • 장혜란;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.393-398
    • /
    • 2001
  • Polymerization of light-activated restorations results in temperature increase caused by both the exothermic reaction process and the energy absorbed during irradiation. Within composite resin, temperature increases up to 2$0^{\circ}C$ or more during polymerization. But, insulation of hard tissue of tooth lowers this temperature increase in pulp. However, many clinicians are concerned about intrapulpal temperature injury. The purpose of this study was to evaluate temperature changes in the pulp according to various restorative materials and bases during curing procedure. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece fissure bur. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn below restorative materials for evaluating of temperature changes. This thermocouple was connected to temperature-recording device(Multiplication analyzer MX, 6.000, JAPAN). Temperature changes was evaluated from initial 37.$0^{\circ}C$ after temperature changes to 37.$0^{\circ}C$. Tip of curing unit was placed in the center of prepared cavity separated 1mm from restorative materials. Curing time was 40s. The restorative materials were used with Z 100, Fuji II LC, Compoglass flow and bases were used with Vitrebond, Dycal. Resrorative materials were placed in 2mm. The depth of bases were formed in 1mm and in this upper portion, resin of 2mm depth was placed. This procedure was performed 10 times. The results were as follows. 1. All the groups showed that the temperature in pulp increased as curing time increased 2. The temperature increase of glass ionomer was significantly higher than that of Resin and Compomer during curing procedure (P<0.05). 3. The temperature increase in glass ionomer base was significantly higher than that of Calcium hydroxide base during Resin curing procedure (P<0.05).

  • PDF