• 제목/요약/키워드: Device embolization

Search Result 29, Processing Time 0.023 seconds

Inadvertent Complication of a Pipeline Embolization Device for Treatment with Vertebral Artery Dissecting Aneurysm : Distal Tip Fracture of Delivery Wire

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.521-524
    • /
    • 2016
  • Use of the Pipeline embolization device (PED) has increased based on studies about its safety and effectiveness, and new reports that describe perior postprocedural complications are now emerging. We report a rare periprocedural device-related complication that occurred during endovascular treatment with the pipeline embolization device for a dissecting aneurysm on the vertebral artery. A 55-year old woman was admitted due to left medullary infarction, and angiography showed a fusiform dilatation in the left vertebral artery that was suspicious for dissecting aneurysm. Endovascular treatment with PED was planned. Under general anesthesia, the procedure was performed without significant problems and a PED was deployed in an appropriate position. However, in the final step of the procedure, the distal tip of the PED delivery wire became engaged within a small branch of the posterior cerebral artery and fractured. Fortunately, imaging studies after the procedure revealed neither hemorrhagic nor ischemic stroke, and the patient recovered without neurological morbidities except initial symptoms.

Emergent Surgical Intervention for Embolization of Atrial Septal Defect Closure Device

  • Kim, Young Hak;Kim, Hyuck;Kim, Sung Jin;Kang, Jeong Ho;Chung, Won-Sang;Shin, Jin-Ho;Lim, Young-Hyo
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.320-322
    • /
    • 2012
  • The percutaneous transcatheter closure of secundum atrial septal defect has recently become an increasingly widespread alternative to surgical closure in many centers. Although immediate, short, and intermediate term results of percutaneous transcatheter septal closure are promising, the procedure is not free from inherent complications that could be lethal. We report a case of device embolization necessitating emergent surgical retrieval.

Treatment for Giant Fusiform Aneurysm Located in the Cavernous Segment of the Internal Carotid Artery Using the Pipeline Embolization Device

  • Oh, Se-Yang;Kim, Myeong Jin;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.32-35
    • /
    • 2014
  • The pipeline embolization device (PED) is a new endovascular device for treatment of complex, fusiform and wide-neck intracranial aneurysms. The main mechanism of this stent is to divert the flow in the parent artery with reduction of inflow in the aneurysm leading to thrombosis. We treated a 40-year-old woman who had left facial pain and orbit discomfort. Angiography showed a giant fusiform aneurysm located in the cavernous segment of the left internal carotid artery. A PED was successfully deployed across the aneurysm. The procedure and post-procedural course were uneventful. After 3 months, angiography showed complete obliteration of the aneurysm with good patency of the branching vessels originating from the deployed segment. The patient's symptoms improved completely without complications.

Embolization of the Device to the Left Pulmonary Artery after the Interventional Closure of Ruptured Sinus of Valsalva Aneurysm

  • Choudhry, Lalit Kumar;Rao, Vinay M;Gnanamuthu, Birla Roy;Agrawal, Vishal;Shankar, Ravi;Prasath, Ram
    • Journal of Chest Surgery
    • /
    • v.48 no.3
    • /
    • pp.202-205
    • /
    • 2015
  • Formation of an aneurysm in the sinus of Valsalva of the aortic root is usually due to an area of congenital weakness in its wall. This aneurysm may progressively dilate and rupture into any of the cardiac chambers or into the pericardial cavity. Though this is conventionally treated by surgery, interventional therapy using various closure devices is becoming more common. Embolization of these closure devices may occur. We report a case of embolization of such a device into the left pulmonary artery which during surgical retrieval, unmasked the hidden ventricular septal defect (VSD). Therefore one has to be cautious while making a diagnosis of rupture of the sinus of Valsalva of right coronary sinus without VSD.

First Multi-Detector Computed Tomography Evidence of Transcatheter Pacing System Migration and Embolization into the Pulmonary Vasculature

  • Valente, Tullio;Bocchini, Giorgio;Bigazzi, Maurizio Cappelli;Muto, Massimo;Golino, Paolo;Sica, Giacomo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.310-312
    • /
    • 2020
  • Transcatheter leadless pacemaker dislodgment is a rare and potentially fatal complication of leadless device implantation. We present the first case of multidetector computed tomography images of leadless pacemaker migration and embolization in the pulmonary middle lobe artery. The patient was managed by percutaneous retrieval of the dislodged device and re-implantation in the appropriate position.

Flow diverter stenting for intracranial aneurysms in the pediatric population: Two case reports and literature review

  • Akram M Eraky;Christina Feller;Hatem Tolba;Mokshal Porwal;Raphael H. Sacho;Hirad Hedayat
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.1
    • /
    • pp.58-64
    • /
    • 2024
  • The Pipeline Embolization Device (PED) is a flow-diverting intraluminal device that is approved for use in adults 18 years or older with internal carotid artery aneurysms. However, it can also be used off-label in pediatric patients with aneurysms that cannot be resolved with traditional endovascular treatments. Herein, we present two cases of flow diversion in the pediatric population with complete obliteration of the aneurysm and excellent outcomes. Flow diversion has been shown to be a safe endovascular option in treating complex aneurysms in children. Larger-sized, multicenter trials are encouraged to compare outcomes between flow diversion and other aneurysm treatment options given the rarity of pediatric aneurysms.

Safety and Efficacy of Flow Diverter Therapy for Unruptured Intracranial Aneurysm Compared to Traditional Endovascular Strategy : A Multi-Center, Randomized, Open-Label Trial

  • Kim, Junhyung;Hwang, Gyojun;Kim, Bum-Tae;Park, Sukh Que;Oh, Jae Sang;Ban, Seung Pil;Kwon, O-Ki;Chung, Joonho;Committee of Multicenter Research, Korean Neuroendovascular Society,
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.772-778
    • /
    • 2022
  • Objective : Endovascular treatment of large, wide-necked intracranial aneurysms by coil embolization is often complicated by low rates of complete occlusion and high rates of recurrence. A flow diverter device has been shown to be safe and effective for the treatment of not only large and giant unruptured aneurysms, but small and medium aneurysms. However, in Korea, its use has only recently been approved for aneurysms <10 mm. This study aims to compare the safety and efficacy of flow diversion and coil embolization for the treatment of unruptured aneurysms ≥7 mm. Methods : The participants will include patients aged between 19 and 75 years to be treated for unruptured cerebral aneurysms ≥7 mm for the first time or for recurrent aneurysms after initial endovascular coil embolization. Participants assigned to a flow diversion cohort will be treated using any of the following devices : Pipeline Flex Embolization Device with Shield Technology (Medtronic, Minneapolis, MN, USA), Surpass Evolve (Stryker Neurovascular, Fremont, CA, USA), and FRED or FRED Jr. (MicroVention, Tustin, CA, USA). Participants assigned to a coil embolization cohort will undergo traditional endovascular coiling. The primary endpoint will be complete occlusion confirmed by cerebral angiography at 12 months after treatment. Secondary safety outcomes will evaluate periprocedural and post-procedural complications for up to 12 months. Results : The trial will begin enrollment in 2022, and clinical data will be available after enrollment and follow-up. Conclusion : This article describes the aim and design of a multi-center, randomized, open-label trial to compare the safety and efficacy of flow diversion versus traditional endovascular treatment for unruptured cerebral aneurysms ≥7 mm.

The Usefulness of Transcatheter Arterial Embolization for Panfacial Injury (전체얼굴손상 환자에서 영상중재시술의 유용성)

  • Kim, Jae Woo;Choi, Hwan Jun;Kim, Mi Sun;Yang, Seung Boo
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.358-364
    • /
    • 2007
  • Purpose: A life-threatening hemorrhage resulting from a severe facial fracture is rare, but it needs a prompt and aggressive treatment. Especially, a massive oronasal bleeding combined with midfacial fracture which may result from the rupture of the internal maxillary artery. With the recent advances in the radiologic intervention, its use has increased for managing these life threatening case. We reviewed its usefulness with our experiences and literatures. Methods: A retrospective review was performed to determine the usefulness of the transcatheter arterial embolization in patients with panfacial trauma. If the vital signs were unstable, cardiopulmonary resuscitation was performed. Oronasal bleeding was controlled with nasal packing and electrocautery. All injured regions were studied by radiologic study including CT. Even after primary management, if the oronasal bleeding was persistent, radiologic intervention was performed 10 patients were treated with transcatheter arterial embolization and the bleeding focus controlled by embolization with polyvinyl alcohol and gelfoam. Results: After the intervention, the vital signs became stable and there were no complications from embolization in the follow-up for 6 months. Also patients could recover through appropriate operations. Conclusion: Transcatheter arterial embolization for maxillofacial injury has many advantages for both, the doctor and the patient. First, less pain is induced than a compression device or an operation, which is another way to treat oronasal bleeding. Second, it does not need general anesthesia. And through a single procedure not only we can know the accurate bleeding point, but we can also bleeding by embolization.

Levoatrial Cardinal Vein: Occluder Embolization and Complication Management

  • Mercan, Ilker;Akyuz, Muhammet;Guven, Baris;Isik, Onur
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.214-217
    • /
    • 2021
  • In rare cases, levoatrial cardinal vein may occur as an isolated condition without additional congenital anomalies. Depending on the direction and flow of the shunt, this pathology may produce symptoms; alternatively, it may be asymptomatic, as in the case presented in this study. In asymptomatic cases, complications, such as paradoxical embolism and brain abscess, can arise later. In the 11-year-old patient whose case is presented here, the levoatrial cardinal vein was asymptomatic and incidentally detected. The percutaneous closure method was applied first. However, by 16 hours after the procedure, the occluder device had embolized to the iliac artery. Emergency surgery was performed; first, the occluder device was removed, and levoatrial cardinal vein ligation was then performed via a mini-thoracotomy. The symptoms, diagnosis, and treatment modalities of isolated levoatrial cardinal vein are discussed in the context of this case described herein.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.