• Title/Summary/Keyword: Device Portal

Search Result 98, Processing Time 0.022 seconds

Monte Carlo simulation of the electronic portal imaging device using GATE

  • Chung, Yong-Hyun;Baek, Cheol-Ha;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, the potential of a newly developed simulation toolkit, GATE for the simulation of electronic portal imaging devices (EPID) in radiation therapy was evaluated by characterizing the performance of the metal plate/phosphor screen detector for EPID. We compared the performances of the GATE simulator against MCNP4B code and experimental data obtained with the EPID system in order to validate its use for radiation therapy.

  • PDF

News Recommendation Exploiting Document Summarization based on Deep Learning (딥러닝 기반의 문서요약기법을 활용한 뉴스 추천)

  • Heu, Jee-Uk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.23-28
    • /
    • 2022
  • Recently smart device(such as smart phone and tablet PC) become a role as an information gateway, using of the web news by multiple users from the web portal has been more important things. However, the quantity of creating web news on the web makes hard to catch the information which the user wants and confuse the users cause of the similar and repeated contents. In this paper, we propose the news recommend system using the document summarization based on KoBART which gives the selected news to users from the candidate news on the news portal. As a result, our proposed system shows higher performance and recommending the news efficiently by pre-training and fine-tuning the KoBART using collected news data.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

An Exploratory Study on Future Economic Activity of Digital Convergence Generation (디지털 컨버전스 세대의 미래경제활동 특성에 관한 연구)

  • Kim, Yeon-Jeong;Park, Ki-Ho
    • Journal of Information Technology Services
    • /
    • v.10 no.4
    • /
    • pp.33-46
    • /
    • 2011
  • This research focus on the economic activity as consumer and producer traits of future customers in the convergence age. We assess level of convergence for digital devices and services respectively by questionnaire survey and interview for 14 professions. And then, for evaluating convergence level and usage of digital services of each respondents, we conducted the questionnaire survey for 343 samples. Findings of our research hold that the group who showed higher level of convergence tends to use the socialized digital services more. Convergence generation were heavy users in appstore on smart-phone and wireless game and more participating. In digital service area, facebook/cyworld, twitter, UCC, portal, internet community in digital service. Convergence generation are global network communication, buying decision making activity, actively opinion expression, prosumer attitude, dependency on digital device, experience based purchase behavior, enthusiastic information sharing.

CCD-based EPID and Frame Averaging Technique

  • Kim, Ho-Kyung;Cho, Gyu-Seong;Chung, Yong-Hyun;Ahn, Seong-Kyu;Lee, Hyung-Koo;Kim, Hoi-Nam;Yoon, Sei-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.297-298
    • /
    • 1998
  • Prototype portal imaging device (EPID) based on CCD camera, which has a $20\times20cm^2$ field of view (FOV), has been developed and then tested by acquiring phantom images for 6 MV x-ray beam. While, among the captured images, each frame suffered notorious quantum noise, the frame averaging largely enhanced the image quality against quantum noise. Over 60 frames averaging, the signal-to-noise ratio (SNR) was increased by $\sim20$ times and contrast was increased about 2 times in the skull-region of the acquired head-phantom image.

  • PDF

Development of Knowledge Sharing Platform for Molding & Forming Technology (금형·성형 기술을 위한 생산기반 지식공유형 플랫폼 개발)

  • Bae, S.M.;Lee, H.W.;Heo, Y.M.;Shin, G.H.;Lee, J.W.;Yoon, G.S.
    • Transactions of Materials Processing
    • /
    • v.20 no.8
    • /
    • pp.534-539
    • /
    • 2011
  • The production technology is the basic of manufacturing for various materials and components. This technology can influence the quality and productivity of leading export products such as automobile, ship, and electronic device. Besides, the production technology is very useful to apply to other manufacturing fields and has a great ripple effect. However, it is very difficult to make the production technology into standardization and knowledge-based database because the production technology is dependent in hands-on experience. In this study, the knowledge-sharing platform for the molding & forming technology which is a branch of the production technology is introduced. This platform is web-based system and has the knowledge authoring tool technologies storage, semantic database, and web portal service. Therefore, the molding & forming technology can be shared and spread easily by the knowledge-sharing platform.

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Delayed Presentation of a Post-traumatic Mesenteric Arteriovenous Fistula: A Case Report (외상 후 지연성으로 발생한 장간막 동정맥루: 증례보고)

  • Cho, Jayun;Jung, Heekyung;Kim, Hyung-Kee;Lim, Kyoung Hoon;Chun, Jae Min;Huh, Seung;Park, Jinyoung
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.248-251
    • /
    • 2013
  • Introduction: A post-traumatic mesenteric arteriovenous fistula (AVF) is extremely rare. Case Report: A previously healthy 26-year-old male was injured with an abdominal stab wound. Computed tomography (CT) showed liver injury, pancreas injury and a retropancreatic hematoma. We performed the hemostasis of the bleeding due to the liver injury, a distal pancreatectomy with splenectomy and evacuation of the retropancreatic hematoma. On the 5th postoperative day, an abdominal bruit and thrill was detected. CT and angiography showed an AVF between the superior mesenteric artery (SMA) and the inferior mesenteric vein with early enhancement of the portal vein (PV). The point of the AVF was about 4 cm from the SMA's orifice. After an emergent laparotomy and inframesocolic approach, the isolation of the SMA was performed by dissection and ligation of adjacent mesenteric tissues which was about 6 cm length from the nearby SMA orifice, preserving the major side branches of the SMA, because the exact point of the AVF could not be identified despite the shunt flow in the PV being audible during an intraoperative hand-held Doppler-shift measurement. After that, the shunt flow could not be detected by using an intraoperative hand-held Doppler-shift measuring device. CT two and a half months later showed no AVF. There were no major complications during a 19-month follow-up period. Conclusion: Early management of a post-traumatic mesenteric AVF is essential to avoid complications such as hemorrhage, congestive heart failure and portal hypertension.