This paper describes the portal system architecture of large consumers for ESP(Energy Service Provider) to provide customers with various value added services such as monitoring and controlling a wide variety of electric devices in consumer's premises for optimal energy management from both consumer side and ESP side, and the prototype implementation of 2 kinds of value added services. The architecture is composed of the device portal which gathers the information from electric devices and controls them and the consumer portal which can make ESP operate the optimal energy management with two-way communications. The demand side management and energy management functions was chosen and implemented for the prototype system as value added services. The prototype was designed to create, manage, and trace the events about services between ESP and customers.
Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
한국의학물리학회지:의학물리
/
제32권4호
/
pp.107-115
/
2021
Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.
목적 : matrix ion chamber type의 EPID와 video camera based EPID를 이용한 portal image와 기존의 film을 이용한 port film의 영상의 질을 객관적으로 비교 평가하여 EPID의 유용성을 알아보고자 본 연구를 계획하였다. 대상 및 방법 : 1997년 4월부터 10월까지의 인하대 병원과 세브란스 병원에서 방사선 치료를 받은 골반강내 치료 환자 각 10명씩을 대상으로 환자 1명 당 5-10회의 port film과 EPID를 이용한 portal image를 동시에 얻어 비교하였다. 환자의 나이는 32세에서 79세이었고 2명의 AP영상을 제외하고는 모두 PA영상을 얻었다. 환자의 두께는 17cm에서 20cm으로 비교적 균일하였다. beam energy는 10MV X-ray를 사용하였고 dose rate은 100-300MU/min으로 2-10MU을 주어 영상을 얻었다. port film은 Kodak diagnostic film을 사용하였고 film을 넣는 cassette는 납을 전후에 부착한 것을 이용하였다. source to detector(film) distance는 140cm으로 하였다. 영상의 판독은 4명의 치료방사선과 의사에 의해서 시행되었으며 pelvic brim, sacrum, acetabulum, iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint를 각각 very clear(1), clear(2), visible(3), not clear(4), not visible(5) 다섯 단계로 나누어 점수를 주었다. 결과 : video camera based EPID를 이용하여 얻은 영상을 비교하여 보았을 때 film을 이용한 port film과 enhancement를 시행하지 않은 portal image는 각 해부학적 구조에서는 차이를 보이지 않았다. 그러나 portal image를 window level로 영상의 변화를 주었을 때는 sacrum과 obturator는 영상의 판독에 도움이 되었다. 또한 portal image를 CLAHE로 enhance를 하였을 때는 모든 해부학적 구조물의 판독이 film보다 용이한 것으로 나타났다. matrix ion chamber type의 EPID를 이용하여 얻은 영상에서도 역시 port film과 영상의 변화를 주지 않은 portal image간에는 커다란 차이를 보이지 않았으나, portal image를 window level로 변화를 주었을 경우는 portal film에 비하여 영상의 질이 더욱 좋아지을 알 수 있었다. 결론 : 방사선 치료를 받는 환자 중에서 골반강의 영상에서는 EPID의 영상의 질은 기존의 port film과 비교하여 차이가 없었으며, window level로 영상에 변화를 주거나 enhance를 하였을 경우는 port film보다 더 나은 영상을 얻을 수 있어 기존의 port film을 대체 할 수 있을 것으로 생각된다.
Oh, Se An;Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
Journal of Yeungnam Medical Science
/
제39권2호
/
pp.108-115
/
2022
Background: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Methods: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and Brain-LAB) between June 2019 and March 2021. We analyzed the multileaf collimator DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1% (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). Conclusion: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.
목적 : electronic portal imaging device(EPID)를 이용하여 폐암 환자에서 시행한 검증 영상을 분석하여 3차원 입체 조형치료계획 시 자세 오차(set-up error)와 종양의 이동 거리를 고려한 적절한 차폐 여유를 평가해 보고자 한다. 대상 및 방법 : 1995년 연세암센터 치료방사선과에 내원하여 EPID가 장착된 Clinac 2100C/D를 이용하여 치료받은 폐암 환자 10명을 대상으로 하였다. 환자 1인 당 1 port에 대한 검증 영상을 매일 얻어 random 오차와 systematic 오차를 구했고, 치료 1회 당 중복 영상을 얻어 종양의 움직임을 구했다. 매일 얻은 검증 영상은 103개이었고, 중복 영상은 10개이었다. 결과 : 전체 10 명의 환자의 x 축, y 축으로의 평균 이동은 각각 1.41 mm, 1.78 mm 이었고 systematic 이동은 표준편차가 x 축, y 축으로 각각 4.63 mm, 4.11 mm이었다. random 이동은 각 환자의 평균 이동으로부터 x 축, y 축으로 표준편차가 각각 4.17 mm, 3.31 mm 이었다. 호흡에 의한 y 축으로의 이동은 평균 12.2 mm이었고, 표준편차는 4.03 mm 이었다. 결론 : 폐암 환자에서 3차원 방사선치료를 시행하려고 할 경우 치료 계획 시 clinical target volume에서 x, y 축으로 각각 10 mm, 25 mm 정도의 여유가 필요하다고 보이며, 치료 초기에 각 환자별로 매일 EPID를 이용하여 얻은 검증 영상과, 중복 영상으로 차폐 여유를 적절히 조절해 주어야 할 것이다.
The video based electronic portal imaging device (EPID), which could display the portal image in near real time, was implemented to verify treatment position error in FSRT(Fractionated Stereotatic Radiation Therapy) instead of a portal film. Also, Developed FSRT system was composed of the stereotactic frame, frame mounting system and collimator cones. The verification of treatment position is very crucial in special therapies like FSRT. In general, the FSRT uses high dpse rate at small field size for treating small intracranial lesions. To evaluate quantitative positioning errors in FSRT, we used the first FSRT image as reference image and obtained the second FSRT image that was moved 2mm intentionally and detected intracranial contours after image processing. The generated 2mm error could be verified by overlapping only contours of two images. Through this study, the radiation treatment efficiency could be improved by performing precise radiation therapy with a developed video based EPID and FSRT.
목 적: 전자포탈영상장치 기반의 환자특이적 정도관리를 위한 portal dose image prediction (PDIP)와 anisotropic analytical algorithm (AAA)을 비교하여 성능을 분석하고, AAA를 사용한 portal dosimetry의 임상적 사용 가능성을 평가하고자 한다. 대상 및 방법: 폐암 환자 15명과 간암 환자 17명, 총 32명의 환자를 후향적으로 선정하였다. PDIP와 AAA를 사용하여 검증용 치료계획을 생성하였다. 계산된 분포와 측정된 분포를 비교한 감마통과율(Gamma passing rate, GPR)과 다엽콜리메이터(Multileaf collimator, MLC) 위치 차이를 얻었다. 결 과: 폐암 환자군의 GPR 평균값은 PDIP 사용시 3%/3 mm에 대해 99.5% ± 1.1%, 1%/1 mm에 대해 90.6% ± 5.8%였다. AAA 사용시 3%/3 mm에 대해 98.9% ± 1.7%, 1%/1 mm에 대해 87.8% ± 5.2%였다. 간암 환자군의 GPR 평균값은 PDIP 사용시 3%/3 mm에 대해 99.9% ± 0.3%, 1%/1 mm에 대해 96.6% ± 4.6%였다. AAA 사용시 3%/3 mm에 대해 99.6% ± 0.5%, 1%/1 mm에 대해 89.5% ± 6.4%였다. MLC 위치 차이는 0.013 mm ± 0.002 mm로 적었으며, 감마통과율과 상관관계를 보이지 않았다. 결 론: 전자포탈영상장치 기반 환자특이적 정도관리를 수행할 때 AAA를 임상적으로 portal dosimetry 계산 알고리즘으로써 사용할 수 있다.
목적 : 본 연구의 목적은 섬광판을 사용하는 전자조사문영상장치의 기본적인 선량반응성을 연구하는 것이다. 대상 및 방법 : 팬텀의 두께와 구성 및 팬텀과 영상장치와의 거리를 변화시킴으로 영상장치에 입사하는 방사선질을 변화시켜가면서 조사면평면에서 신호를 읽었다. 또한 섬광에 의한 신호가 전체신호에 기여하는 상대적인 정도를 모사하였다. 결과 : 본 연구는 조사면평면상에서 선량분포가 팬텀과의 거리 및 팬텀의 두께의 함수임을 보였다. 팬텀의 구성에 따라 조사면영상장치에 의한 선량의 오차는 크게는 $7\%$ 에 달하는 것을 발견했다. 영상장치 내부에서 발생하는 섬광의 산란이 오차의 중요한 원인이 됨을 또한 발견했다. 결론 : 본 연구에서 우리는 조사면영상장치의 선량반응성의 기본적인 특성을 알았다. 또한 섬광판을 기초로 한 영상장치는 정확한 선량측정시스템이 되지 못함을 보았다.
목 적: 필름평가방법을 대신하여 전자포탈영상을 이용한 기하학적 정도관리 실시간 분석 프로그램을 개발하고자 한다. 대상 및 방법: 전자포탈영상장치(Electronic Portal Image Device, EPID)가 선형가속기(CL-iX, Varian, USA)의 하부에 고정된 구조 때문에 발생되는 문제를 해결한 후 Eclipse treatment planning system (Version 8.1, Varian, USA)으로 기하학적 정도관리 항목을 생성하였다. 치료실의 4DTC (Version 10.2, Varian, USA)에서 전자포탈영상(single exposure before plan)을 생성하고 항목별로 빔을 조사하였다. Off-line review에서 전자포탈영상을 획득하고 이를 자체 개발한 기하학적 정도관리 실시간 분석 프로그램으로 평가하였다. 평가 방법으로 치료 중 오차(Intra-fraction error)는 모든 절차를 같은 날에 동일 조건으로 5회 연속 실시하여 분석하였고 치료 간 오차(Inter-fraction error)의 확인을 위해 모든 절차를 동일 조건에서 10일간 실시한 후 Iso-align$^{TM}$ quality control device를 이용한 필름평가방법과 비교하였다. 측정 및 분석 시간은 장치의 셋업에서 데이터 획득까지의 시간과 이후 분석완료까지 소요된 시간으로 구분하여 측정한 후 사용자와 수행과정의 편의성도 비교하였다. 결 과: 빛-방사선조사면 일치, 콜리메이터 회전축, 환자테이블 회전축, 갠트리 회전축 항목에서 각각 평균 0.1, 0.2, 0.3, 0.2 mm의 치료 중 오차 값을 확인하였다. 10일간의 연속된 정도관리를 통해 치료 간 오차를 확인한 결과 항목별로 각각 평균 1.7, 1.4, 0.7, 1.1 mm의 오차 값을 얻었다. 그리고 측정 시간은 필름평가방법과 전자포탈영상을 이용한 방법에서 각각 평균 36분, 15분이 걸렸고 분석 시간은 평균 30분, 22분이 소요되었다. 결 론: 전자포탈영상을 이용하여 기하학적 정도관리를 실시할 경우 정도관리 도구로서 유용함을 알 수 있었다. 필름 미사용에 따른 비용 절감의 이점뿐만 아니라 측정 및 분석 시간도 줄일 수 있어 사용자 편의성이 커지고 필름 현상 과정 등의 생략으로 수행과정도 개선할 수 있었다. 또 자체 개발한 기하학적 정도관리 실시간 분석 프로그램으로 평가가 완료된 영상은 데이터화가 가능하여 자료의 보관이 용이해진다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.