• Title/Summary/Keyword: Deviation ratio

Search Result 930, Processing Time 0.026 seconds

A Study on the Efficiency of Clinical Practice for Nursing Education in the Junior College of Nursing in Korea (전문대학 간호과의 임상 실험 효율화를 위한 연구)

  • Lee, Kun-Ja;Kim, Myung-Soon;Yang, Young Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.77-108
    • /
    • 1989
  • The purpose of this study was to find out the present condition of clinical practice and to develop a scheme on the efficiency of clinical practice for nursing education in junior college of nursing in korea. This study was conducted by 2 sections. Ist section was to find out the present condition of clinical practice to 42 directors of nursing collegd and data were collected July 8 to September 30, 1988. 2nd section wat to develop a scheme on the efficiency of clinical practice for nursing education and subjects were nursing professors 258: and clinical nurses 223 in 42 junior nursing colleges their clinical settings in korea. So total subjects were 481. Data were collected july 8, 1988 to June 30, 1988 and were analysed to get the mean, standand deviation, frequency, percentage, t-test, x-test used by SPSS - pc. Major findings were as follows: 1. The present condition of clinical education in junior college of nursing in Korea. 1) 32 colleges (76.2%) were managed by a-yeas system. 2) 25 colleges (59.5%) were performed by individual practice for each subject. 3) 4 weeks interval between class education and clinical education was a major type among total colleges(36.6%, J5 colleges) 4) 30 colleges (71.4%) provided clinical education for all subjects that should be practiced. Nursing administration wes not practiced in 5 colleges (41.9%) among the remainder(12 colleges). The main cause that all practice subjects were not practiced was the lack or absence of suitable clinical settings(8 colleges. 66.7%) 5) 18 colleges (42.9%) responded that a clinical educator was, subject-charged professor. 6) 12 colleges (29.3%) responded that a clinical instructor was in charge of 6~10 students. 7) The evaluation ration ratio(professor to head nurse) by each evaluator was mostly 50% to 50 % and 60% to 40%, respectively 11 colleges(27.5%) The most common evaluation methods were evaluation by head nures, report, presence, conference (11 colleges, 27.5%) 8) The field carrier of professor was mostly 2 years (79 persons, 20.7%) and mean was 3.2 years. The education carrier of a professor was mostly over than 6 years (261 persons, 66.4%) and mean was 9.2 years. The charge hours per-week of a professor were mostly 16-18 hours (16 persons, 131.8%) 9) 34 colleges (82.9%) approved that clinical practice hour was class hour and 18 colleges (43.9 %) counted that 2 hours of clinical education equaled 1 hour of class education. 2. A study 'on the efficiency of clinical practice for nursing education. L) general characteristics of subjects were as follows: kung-sang province (145 persons, 30.5%), 30-34 years (190 persons, 39.8%), graduated degree (245 persons, 51.5%), 6-10 years of carrier (199 persons, 41.4%) were the majority. 2) suitable clinical setting was responded the systematic ward with responsible clinical educator by 210 persons(43.8%) The response by working field of subjects showed a significant difference (p< 0.01) 3) 259 subjects (54.0%) responded that the desirable qualfication of clinical instructor was 3-5 years of clinical experience with master degree or higher. 4) The mean score of desirable quality degree of clinical instructor was 3.43 professors, score (3.54) was significantly higher than clinical nurses' (3.28) (p<0.01) 412 subjects (86.0%) responded that the insufficient guality of instructor was improved by continuing to seek more new information in reference. 5) 196 subjects (41.4%) responded that desirable qualification of head nurse was more than 2 years of head position among 5 years of clinical experience. The response by working' field of subjects showed a significant difference (p<0.05) 6) The mean score of desirable quality degree of head nurse was 3.18 Clinical nurses' score(3.38) was significantly higher than professors' (3.01) (p<0.01) 419 subjects (87.8%) responded that the insufficient of head nurse was improved by continuing relationship with instructor and being responsible from planing of clinical education. 7) The mean score of performance level of the desirable clinical education guide incollege was 2.91 Professors' score (2.96) was significantly higher than clinical nurses' (2.84) (p<0.01) 340 subjects (71.1%) responded that the possible resolution for poor performance was the more specified syllabus of clinical education and the satisfiable orientation for students. 8) The mean score of performance level of the desirable clinical education guide in hospital was 3.03 9) 141 subjects (29.6%) responded that the desirable clinical evaluator was the group of professor, head nurse, staff nurse. Response by working field of subjects was a significant difference (p< 0.05) 10) The mean score of performance level of the evaluation content needed in clinical education was 3.50 Clinical nurses' score (3.56) was significantly higher than professors' (3.45) (p<0.01) 11) 433 subjects (90.2%) responded that6 desirable evaluation method for clinical education was the presence. 12) The mean score of performance level about how personal difference among clinical educators was minimized was 2.89 and response by working field of subjects was not significant. The cause of poor performance was too much workload at clinical settings and too many students st colleges by 386 subjects (81.1%).

  • PDF

Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy (3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석)

  • Seong, Yeol-Hun;Rhim, Jae-Dong;Lee, Jae-Hyun;Cho, Sung-Bong;Woo, Dong-Chul;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.256-262
    • /
    • 2008
  • To evaluate the metabolic changes in normal adult brains due to alterations SENSE and NEX (number of excitation) by multi voxel MR Spectroscopy at 3.0 Tesla. The study group was composed of normal volunteers (5 men and 8 women) with a mean ($\pm$ standard deviation) age of 41 (${\pm}11.65$). Their ages ranged from 28 to 61 years. MR Spectroscopy was performed with a 3.0T Achieva Release Version 2.0 (Philips Medical System-Netherlands). The 8 channel head coil was employed for MRS acquisition. The 13 volunteers underwent multi voxel spectroscopy (MVS) and single voxel spectroscopy (SVS) on the thalamus area with normally gray matter. Spectral parameters were as follows: 15 mm of thickness; 230 mm of FOV (field of view); 2000 msecs of repetition time (TR); 288 msecs of echo time (TE); $110{\times}110$ mm of VOI (view of interest); $15{\times}15{\times}15$ mm of voxel size. Multi voxel spectral parameters were made using specially in alteration of SENSE factor (1~3) and 1~2 of NEX. All MRS data were processed by the jMRUI 3.0 Version. There was no significant difference in NAA/Cr and Cho/Cr ratio between MVS and SVS likewise the previous results by Ross and coworkers in 1994. In addition, despite the alterations of SENSE factor and NEX in MVS, the metabolite ratios were not changed (F-value : 1.37, D.F : 3, P-value : 0.262). However, line-width of NAA peak in MVS was 3 times bigger than that in SVS. In the present study, we demonstrated that the alterations of SENSE factor and NEX were not critically affective to the result of metabolic ratios in the normal brain tissue.

  • PDF

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Seasonal Variations of Metacercarial DEnsity of Clonorchis sinensis in Fish Intermediate Host, Pseudorasbora parva (간흡충 유행지역에서 참붕어내 피낭유충 감염밀도의 계절적 변동)

  • Gang, Sin-Yeong;Kim, Seok-Il;Jo, Seung-Yeol
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.1
    • /
    • pp.87-94
    • /
    • 1985
  • The seasonal variations of the rate and intensity of metacercarial infection of C. sinensis in P. parva were observed. The fish were collected at Sun-Am River which located in Kim-Hae City, Kyong-Sang Nam Do (=Province), Korea, from March 1983, to February 1984 every month. A total of 788 fish was examined. The number of metacercariae in each fish was individually counted after the individual digestion by artificial gastric juice. The results were as follows: 1. During one year, 513 (65.1%) out of 788 fish were infected with metacercariae. In May, June, July and September, the infection rates ranged from 82.0% to 98.6% whereas the rates was relatively low in March, April, November and February ranging from 11.4% to 64.7%. 2. The intensity of infection was similar with those of infection rates. The mean intensity per infected fish was 103.0 and standard deviation was 118.9 throughout one year. The highest mean intensity was in June (294.8) and the lowest in November (11.1). 3. The observed frequency of fish with certain intensities of metacercariae were fitted to theoretical equations derived from negative binomial distribution in March, April, November and February (p>0.05). Meanwhile, the equation of lognormal distribution were fitted with the observed frequencies in May, June, July and September (p>0.05, p>O. 75). The variance/mean ratio varied by month. The value was the highest in July (814.3) and the lowest in November (158.8). Unlike our hypothesis, the metacercarial density of Clonorchis sinensis in its the most favorable fish host, Pseudorasbora parva showed considerable seasonal variations in the hyperendemic area. The possible factors were discussed.

  • PDF

Development of NCS Based Vocational Curriculum Model for the Practical and Creative Human Respirces (실전 창의형 인재 양성을 위한 NCS 기반 직업교육과정의 모형 개발)

  • Kim, Dong-Yeon;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.39 no.2
    • /
    • pp.101-121
    • /
    • 2014
  • The study aims to develop the NCS based vocational curriculum model for the practical and creative human resources. For effectiveness of the study, the study consists of literature studies of both domestic and international, contents analysis, case study, expert(9samples) consultation and review, and in-depth-interview of the three advisory members. The validity of the developed model is analyzed through mean, standard deviation and contents validity ratio(CVR). The main results of the model development in our study are as follow. First, our NCS based vocational curriculum model for the practical and creative human resources is developed with the analyses of NCS development manuals, training standard utilization and training curriculum organization manuals, NCS learning module development manual and case studies, NCS research report, NCS based curriculum pilot development resources directed toward the high schools and vocational school as well as the domestic and international literature study on career training model like NCS. Second, based on the findings of our analysis in combination with the findings from the consultations with the expert and advisory committee, total 19 sub-factors of each step and domain are extracted. The sub-factors of domain in step 1 are the competency unit, definition of competency unit, competency unit element, performance criteria, range of variable, guide of assessment, key competency; in step 2, they are subject title, subject objectives, chapter title, chapter objectives, pedagogical methods, assessment methods and basic job competence; and in step 2, they are NCS based subject matrix table, NCS based subject profile, NCS based job training curriculum table, NCS based subjects organization flowchart, NCS based job training operation plan. Third, the final model including step 3 NCS based subject profile are developed in association with the linked organizational sub-factors of step 1 and step 2. Forth, the validity tests for the final model by the step and domain yield the mean 4.67, CVR value 1.00, indicating the superior validity. Also, the means of each sub-factors are all over 4.33 with the CVR value 1.00, indicating the high validity as well. The means of the associated organizations within the model are also over 4.33 with the CVR value of 1.00. Standard deviations are all .50 or lower which are small. Fifth, based on the validity test results and the in-depth-interview of the expert and advisory committee, the model is adjusted complemented to establish final model of the NCS based vocational curriculum for the practical and creative human resources.

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Development of a Occupation-Based Bilateral Upper Extremity Training Protocol in a Medical Setting for Stroke Patients (뇌졸중 환자를 대상으로 한 병원 환경에서의 작업 기반 양측성 상지 훈련 프로토콜 개발)

  • Kim, Sun-Ho;Kim, Jung Ran;Park, Hae Yean;Han, A-Reum;Kim, Jong-Bae;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.9 no.1
    • /
    • pp.24-44
    • /
    • 2020
  • Objective : To develop an occupation-based bilateral upper extremity training protocol that can be effectively applied in a medical setting Methods : The research process using the delphi technique was carried out in 3 stages. The first stage was an open questionnaire development stage, The first draft is prepared through literature review and open questions were developed through preliminary research based on the draft. The second stage was the delphi survey. Based on the responses of the experts obtained through the open Delphi survey, the adequacy of the training protocol was shown on a Likert 5 point scale. The items were edited and deleted, reconstructed by analyzing the mean and standard deviation, stability, convergence degree, consensus, and content validity ratio through the questionnaire. The third step was the completion of the protocol. After discussions between researchers, the finalized protocol contents were reorganized to complete the occupation-based bilateral upper extremity training protocol for medical setting. Results : The final protocol consisted of 9 items across 3 areas in the occupation-based intervention selection domain and 81 items across 4 areas in the bilateral upper extremity training domain, intervention period, and evaluation. Conclusions : This study suggests an evidence-based method that collects the opinions of occupational therapists in order to use occupation-based activities as interventions in a situation that currently sees occupational therapy primarily performed in hospitals. It is also meaningful that the bilateral upper extremity training can be applied effectively in clinical situations by concretely presenting.

Pediatric Peritoneal Dialysis in Korea : Practical Solution to the Problems of Peritoneal Dialysis for Children (한국 소아복막투석의 현황 - 다기관 공동연구 결과보고 -)

  • Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 1998
  • Purpose : To find and solve the common problems of peritoneal dialysis(PD) by analysing the clinical data of pediatric PD performed in Korea. Methods : 264 cases of CAPD and acute PD had been performed from Nov.1987 to Oct. 1997 in 17 institutions of pediatric nephrology in Korea. Results : CAPD was performed in 114 cases. The mean age of the patients was $10.5{\pm}6.6$ years and male to female ratio was 1.4:1. The original renal diseases of ESRD were proven in 92 cases($80\%$). The common renal disease of ESRD were FSGS($17\%$), reflux nephropathy ($11\%$), chronic glomerulonephritis($9.6\%$). Mean duration of CAPD was $20{\pm}16.9$ months. Peritonitis was the most common complication and incidence was one episode/18.2 patient-months. Other complications were exit site infection in 10 cases, obstruction in 7 cases, leakage of dialysate in 6 cases. The most common etiologic organism of peritonitis was staphylococcus aureus and the next was staphylococcus coagulase(-). Acute PD was performed in 150 cases. Most common underlying causes were congenital heart disease, hemolytic uremic syndrome, sepsis and dehydration. The mean duration was $10.3{\pm}11.3$ days. The most common complication was peritonitis($20.6\%$). The most common etiologic organism was staphylococcus aureus and coagulase(-), acinetobactor and pseudomonas. Conclusion : Reflux nephropathy should be emphasized in early diagnosis and treatment to prevent ESRD. Incidence of congenital anomaly($7\%$) as a original disease of ESRD was relatively low in Korea. Growth status was not significantly improved after CAPD. In acute PD, the incidence of peritonitis was rapidly increased at 2weeks after beginning of dialysis.

  • PDF

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF