• Title/Summary/Keyword: Deviation ratio

Search Result 916, Processing Time 0.031 seconds

Seasonal Variations of Metacercarial DEnsity of Clonorchis sinensis in Fish Intermediate Host, Pseudorasbora parva (간흡충 유행지역에서 참붕어내 피낭유충 감염밀도의 계절적 변동)

  • Gang, Sin-Yeong;Kim, Seok-Il;Jo, Seung-Yeol
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.1
    • /
    • pp.87-94
    • /
    • 1985
  • The seasonal variations of the rate and intensity of metacercarial infection of C. sinensis in P. parva were observed. The fish were collected at Sun-Am River which located in Kim-Hae City, Kyong-Sang Nam Do (=Province), Korea, from March 1983, to February 1984 every month. A total of 788 fish was examined. The number of metacercariae in each fish was individually counted after the individual digestion by artificial gastric juice. The results were as follows: 1. During one year, 513 (65.1%) out of 788 fish were infected with metacercariae. In May, June, July and September, the infection rates ranged from 82.0% to 98.6% whereas the rates was relatively low in March, April, November and February ranging from 11.4% to 64.7%. 2. The intensity of infection was similar with those of infection rates. The mean intensity per infected fish was 103.0 and standard deviation was 118.9 throughout one year. The highest mean intensity was in June (294.8) and the lowest in November (11.1). 3. The observed frequency of fish with certain intensities of metacercariae were fitted to theoretical equations derived from negative binomial distribution in March, April, November and February (p>0.05). Meanwhile, the equation of lognormal distribution were fitted with the observed frequencies in May, June, July and September (p>0.05, p>O. 75). The variance/mean ratio varied by month. The value was the highest in July (814.3) and the lowest in November (158.8). Unlike our hypothesis, the metacercarial density of Clonorchis sinensis in its the most favorable fish host, Pseudorasbora parva showed considerable seasonal variations in the hyperendemic area. The possible factors were discussed.

  • PDF

Development of NCS Based Vocational Curriculum Model for the Practical and Creative Human Respirces (실전 창의형 인재 양성을 위한 NCS 기반 직업교육과정의 모형 개발)

  • Kim, Dong-Yeon;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.39 no.2
    • /
    • pp.101-121
    • /
    • 2014
  • The study aims to develop the NCS based vocational curriculum model for the practical and creative human resources. For effectiveness of the study, the study consists of literature studies of both domestic and international, contents analysis, case study, expert(9samples) consultation and review, and in-depth-interview of the three advisory members. The validity of the developed model is analyzed through mean, standard deviation and contents validity ratio(CVR). The main results of the model development in our study are as follow. First, our NCS based vocational curriculum model for the practical and creative human resources is developed with the analyses of NCS development manuals, training standard utilization and training curriculum organization manuals, NCS learning module development manual and case studies, NCS research report, NCS based curriculum pilot development resources directed toward the high schools and vocational school as well as the domestic and international literature study on career training model like NCS. Second, based on the findings of our analysis in combination with the findings from the consultations with the expert and advisory committee, total 19 sub-factors of each step and domain are extracted. The sub-factors of domain in step 1 are the competency unit, definition of competency unit, competency unit element, performance criteria, range of variable, guide of assessment, key competency; in step 2, they are subject title, subject objectives, chapter title, chapter objectives, pedagogical methods, assessment methods and basic job competence; and in step 2, they are NCS based subject matrix table, NCS based subject profile, NCS based job training curriculum table, NCS based subjects organization flowchart, NCS based job training operation plan. Third, the final model including step 3 NCS based subject profile are developed in association with the linked organizational sub-factors of step 1 and step 2. Forth, the validity tests for the final model by the step and domain yield the mean 4.67, CVR value 1.00, indicating the superior validity. Also, the means of each sub-factors are all over 4.33 with the CVR value 1.00, indicating the high validity as well. The means of the associated organizations within the model are also over 4.33 with the CVR value of 1.00. Standard deviations are all .50 or lower which are small. Fifth, based on the validity test results and the in-depth-interview of the expert and advisory committee, the model is adjusted complemented to establish final model of the NCS based vocational curriculum for the practical and creative human resources.

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Development of a Occupation-Based Bilateral Upper Extremity Training Protocol in a Medical Setting for Stroke Patients (뇌졸중 환자를 대상으로 한 병원 환경에서의 작업 기반 양측성 상지 훈련 프로토콜 개발)

  • Kim, Sun-Ho;Kim, Jung Ran;Park, Hae Yean;Han, A-Reum;Kim, Jong-Bae;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.9 no.1
    • /
    • pp.24-44
    • /
    • 2020
  • Objective : To develop an occupation-based bilateral upper extremity training protocol that can be effectively applied in a medical setting Methods : The research process using the delphi technique was carried out in 3 stages. The first stage was an open questionnaire development stage, The first draft is prepared through literature review and open questions were developed through preliminary research based on the draft. The second stage was the delphi survey. Based on the responses of the experts obtained through the open Delphi survey, the adequacy of the training protocol was shown on a Likert 5 point scale. The items were edited and deleted, reconstructed by analyzing the mean and standard deviation, stability, convergence degree, consensus, and content validity ratio through the questionnaire. The third step was the completion of the protocol. After discussions between researchers, the finalized protocol contents were reorganized to complete the occupation-based bilateral upper extremity training protocol for medical setting. Results : The final protocol consisted of 9 items across 3 areas in the occupation-based intervention selection domain and 81 items across 4 areas in the bilateral upper extremity training domain, intervention period, and evaluation. Conclusions : This study suggests an evidence-based method that collects the opinions of occupational therapists in order to use occupation-based activities as interventions in a situation that currently sees occupational therapy primarily performed in hospitals. It is also meaningful that the bilateral upper extremity training can be applied effectively in clinical situations by concretely presenting.

Pediatric Peritoneal Dialysis in Korea : Practical Solution to the Problems of Peritoneal Dialysis for Children (한국 소아복막투석의 현황 - 다기관 공동연구 결과보고 -)

  • Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 1998
  • Purpose : To find and solve the common problems of peritoneal dialysis(PD) by analysing the clinical data of pediatric PD performed in Korea. Methods : 264 cases of CAPD and acute PD had been performed from Nov.1987 to Oct. 1997 in 17 institutions of pediatric nephrology in Korea. Results : CAPD was performed in 114 cases. The mean age of the patients was $10.5{\pm}6.6$ years and male to female ratio was 1.4:1. The original renal diseases of ESRD were proven in 92 cases($80\%$). The common renal disease of ESRD were FSGS($17\%$), reflux nephropathy ($11\%$), chronic glomerulonephritis($9.6\%$). Mean duration of CAPD was $20{\pm}16.9$ months. Peritonitis was the most common complication and incidence was one episode/18.2 patient-months. Other complications were exit site infection in 10 cases, obstruction in 7 cases, leakage of dialysate in 6 cases. The most common etiologic organism of peritonitis was staphylococcus aureus and the next was staphylococcus coagulase(-). Acute PD was performed in 150 cases. Most common underlying causes were congenital heart disease, hemolytic uremic syndrome, sepsis and dehydration. The mean duration was $10.3{\pm}11.3$ days. The most common complication was peritonitis($20.6\%$). The most common etiologic organism was staphylococcus aureus and coagulase(-), acinetobactor and pseudomonas. Conclusion : Reflux nephropathy should be emphasized in early diagnosis and treatment to prevent ESRD. Incidence of congenital anomaly($7\%$) as a original disease of ESRD was relatively low in Korea. Growth status was not significantly improved after CAPD. In acute PD, the incidence of peritonitis was rapidly increased at 2weeks after beginning of dialysis.

  • PDF

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Educational Needs of Elderly Hypertensive or Diabetes Patients and Educators for Education Program Development of Cardiocerebrovascular High-risk Group (심뇌혈관질환 고위험군 교육프로그램개발을 위한 노인 고혈압·당뇨병환자와 교육자의 교육요구도 및 지식수준에 대한 비교분석)

  • Lee, Hye-Jin;Kam, Sin
    • Journal of agricultural medicine and community health
    • /
    • v.35 no.2
    • /
    • pp.177-192
    • /
    • 2010
  • Objectives: This study was conducted to examine the educational needs of elderly hypertensive or diabetes patients and educators for the education program development of cardiocerebrovascular high-risk group in community. Methods: This study was conducted with 60 hypertensive or diabetes patients aged 65 years or above (cardiocerebrovascular high-risk group) who had registered KHyDDI(Korea Hypertension Diabetes Daegu Initiative) Project and attended Hypertension Diabetes Intervention Center Program, and with 44 educators in the center between June and August, 2009. Data were collected using questionnaires including general characteristics, educational objectives, curriculum, contents, and methods. Results: The major findings of this study were as follows: In education methods, cardiocerebrovascular high-risk group and educators both preferred small-grouped(5-9 persons) or individual education, 30min-1 hour, 50%-50% of theory-practice ratio, 3 months of education. In education contents, both groups needed all the suggested contents. Five categories would be suggested for the development of education program. The first category was that there was no significant difference between cardiocerebrovascular high-risk group's needs and knowledge. The second was category of low knowledge level in cardiocerebrovascular high-risk group's knowledge. The repeated education would be necessary for this category. The third was category with large standard deviation in cardiocerebrovascular high-risk group's knowledge. Individual education would be necessary for this category. The fourth category was that there was significant difference between cardiocerebrovascular high-risk group's knowledge and knowledge assessed by educators. The improvement of educator's education skill would be necessary for this category. The fifth category was that there was significant difference between cardiocerebrovascular high-risk group and educator's needs. Conclusions: Small group or individualized and staged education reflecting above cardiocerebrovascular high risk group and educators' needs should be developed for more effective education to prevent and manage the cardiocerebrovascular disease.

A Study on the Standardization of QSCC II (Questionnaire for the Sasang Constitution Classification II) (사상체질분류검사지(四象體質分類檢査紙)(QSCC)II의 표준화(標準化) 연구(硏究) - 각 체질집단의 군집별(群集別) Profile 분석을 중심으로 -)

  • Kim, Sun-Ho;Ko, Byung-Hee;Song, Il-Byung
    • The Journal of Korean Medicine
    • /
    • v.17 no.2 s.32
    • /
    • pp.337-393
    • /
    • 1996
  • The purpose of this study is to evaluate and standardize the four scales of Questionnaire for the Sasang Constitution Classification  II (QSCCII). QSCCII is newly prepared by statistical item analysis and is designed to examine its diagnostic discriminability. QSCCII is administered to 1366 random informants. From the survey, we could get the data for the standardization. The criteria of standardization are based on the data from 265 informants who are examined by professionals. Collectted data are analyzed by internal consistency, variation analysis(ANOVA), Duncan test and discrimination analysis of SPSS PC+ V4.0 program. The results are as follows reliability of four scales for QSCCII is relatively valid. The internal consistency of Tae-yang(太陽) (太陽) scale is Cronbach's a=0.5708. That of So-yang(少陽) scale is a=0.5708. That of Tae-eum(太陰) scale is a =0.5922. That of So-eum(少陰) scale is a=0.6319. 2. There is a significant difference between each group through variation analysis of four scales. 3. The process of standardization is based on the average value and standard deviation with respect to age and sex difference of each criteria 4. This study suggests a source of standardization of Sasang Constitution Classification by providing norms in which the differences of age, sex, and number of items are taken into deep consideration. QSCC Ⅱ, therefore, can be applied to every age(the 10's to the 60's) and sex groups. 5. The recalculation of the raw-score to standard value (T-score) shows that the diagnostic discriminability (Hit-ratio: 70.08%) of QSCC Ⅱ brings about 37% improvement than proportional chance criteria (33.33%). Especially, Hit-ratios of Tae-eum In(74.5%) and So-eum In(70.8%) are higher than that of So-yang In(60.0%). 6. QSCC has discriminability only to male informants. Compared with QSCC, however, QSCC II has relatively efficient discriminability both to male and female informants. 7. These results would be a demonstration of the fact that the QSCC II could be used as a tool for sasang constitution classification.

  • PDF

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.