• Title/Summary/Keyword: Development of a Measuring Instrument

Search Result 206, Processing Time 0.023 seconds

Development of a Catalyst/Sorbent for Methane-Steam Reforming (메탄스팀개질반응용 촉매흡착제 개발에 관한 연구)

  • Cho, Yong-Hoon;Na, Jeong-Geol;Kim, Seong-Soo;Kim, Jin-Gul;Chung, Soo-Hyun
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.307-313
    • /
    • 2006
  • In order to improve the efficiency of methane steam reforming process, a part of the system which produces hydrogen from heavy hydrocarbon resources such as coal, we combined metal catalyst with CaO sorbent and fabricated catalyst/sorbent. To increase the porosity and the compressive strength of sorbent, carbon black and ${\alpha}-alumina$ were mixed with CaO powder during preparation. The effects of sorbent composition on the physical properties were investigated by SEM, TGA, BET, XRD, abrasion strength measuring device and adsorption-desorption instrument. Sorbent with 5 wt% $Al_2O_3$ and 10 wt% carbon black showed the best physical features with $7.61kg_f$ strength and 47% $CO_2$ adsorption capability. Various metal catalysts such as Ni, Co and Fe were supported on the sorbent developed and 10 wt% Ni/sorbent was selected for methane steam reforming process based on the result of reaction experiment. The reaction system using the catalyst/sorbent showed better $H_2$ productivity compared to the detached system with catalyst and sorbent, indicating the effectiveness of the system developed in this study.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Distance Measurement of Small Moving Object using Infrared Stereo Camera (적외선 스테레오 카메라를 이용한 소형 이동체의 거리 측정)

  • Oh, Jun-Ho;Lee, Sang-Hwa;Lee, Boo-Hwan;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.53-61
    • /
    • 2012
  • This paper proposes a real-time distance measurement system of high temperature and high speed target using infrared stereo camera. We construct an infrared stereo camera system that measure the difference between target and background temperatures for automatic target measurement. First, the proposed method detects target region based on target motion and intensity variation of local region using difference between target and background temperatures. Second, stereo matching by left and right target information is used to estimate disparity about real-time distance of target. In the proposed method using infrared stereo camera system, we compare distances in three dimension trajectory measuring instrument and in infrared stereo camera measurement. In this experiment from three video data, the result shows an average 9.68% distance error rate. The proposed method is suitable for distance and position measurement of varied targets using infrared stereo system.

Measuring Willingness to Pay for PM10 Risk Reductions: Evidence from Averting Expenditures for Anti-PM10 Masks and Air Purifiers (미세먼지 건강위험 감소에 대한 지불의사 측정: 마스크 착용과 공기청정기 사용에 따른 회피비용을 중심으로)

  • Eom, Young Sook;Kim, Jin Ok;Ahn, So Eun
    • Environmental and Resource Economics Review
    • /
    • v.28 no.3
    • /
    • pp.355-383
    • /
    • 2019
  • This study is to investigate whether averting costs for wearing $anti-PM_{10}$ masks and using air purifiers at home to reduce exposure from $PM_{10}$ are influenced by subjective risk perceptions and/or objective $PM_{10}$ concentration levels, whose estimates will be used to measure the willingness to pay for $PM_{10}$ risk reduction. An empirical analysis was conducted on a sample of 1,224 respondents who participated in the web-based survey in the late October of 2017. As we reflect the potential endogeniety bias in the estimation of averting cost functions of using air purifiers, the coefficients of risk perception were differed by 6~7 times. Respondents. subjective risk perceptions were influenced by individuals' knowledge, attitudes and demographic variables, as well as the levels of $PM_{10}$ concentrations in their residential region. The marginal willingness to pay for risk reductions at the mean levels of their risk perceptions were measured at 1,000 won per month from wearing $anti-PM_{10}$ masks and 6,000 won for using air purifiers respectively.

Development of NQ-E, Nutrition Quotient for Korean elderly: item selection and validation of factor structure (노인 대상 영양지수 개발 : 평가항목 선정과 구성 타당도 검증)

  • Chung, Min-Jae;Kwak, Tong-Kyung;Kim, Hye-Young;Kang, Myung-Hee;Lee, Jung-Sug;Chung, Hae Rang;Kwon, Sehyug;Hwang, Ji-Yun;Choi, Young-Sun
    • Journal of Nutrition and Health
    • /
    • v.51 no.1
    • /
    • pp.87-102
    • /
    • 2018
  • Purpose: The purpose of this study was to develop a valid instrument for measuring the dietary quality and behaviors of Korean elderly. Methods: The development of the Nutrition Quotient for Elderly (NQ-E) was conducted in three steps: item generation, item reduction, and validation. The 41 items of the NQ-E checklist were derived from a systematic literature review, expert in-depth interviews, statistical analyses of the fifth Korean National Health and Nutrition Examination Survey data, and national nutrition policies and recommendations. Pearson's correlation was used to determine the level of agreement between the questionnaires and nutrient intake level, and 24 items were selected for a nationwide survey. A total of 1,000 nationwide elderly subjects completed the checklist questionnaire. The construct validity of the NQ-E was assessed using confirmatory factor analysis, LISREL. Results: The nineteen checklist items were used as final items for NQ-E. Checklist items were composed of four-factors: food behavior (6 items), balance (4 items), diversity (6 items), and moderation (3 items). The standardized path coefficients were used as the weights of the items. The NQ-E and four-factor scores were calculated according to the obtained weights of the questionnaire items. Conclusion: NQ-E would be a useful tool for assessing the food behavior and dietary quality of the elderly.

Review of applicability of Turbidity-SS relationship in hyperspectral imaging-based turbid water monitoring (초분광영상 기반 탁수 모니터링에서의 탁도-SS 관계식 적용성 검토)

  • Kim, Jongmin;Kim, Gwang Soo;Kwon, Siyoon;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.919-928
    • /
    • 2023
  • Rainfall characteristics in Korea are concentrated during the summer flood season. In particular, when a large amount of turbid water flows into the dam due to the increasing trend of concentrated rainfall due to abnormal rainfall and abnormal weather conditions, prolonged turbid water phenomenon occurs due to the overturning phenomenon. Much research is being conducted on turbid water prediction to solve these problems. To predict turbid water, turbid water data from the upstream inflow is required, but spatial and temporal data resolution is currently insufficient. To improve temporal resolution, the development of the Turbidity-SS conversion equation is necessary, and to improve spatial resolution, multi-item water quality measurement instrument (YSI), Laser In-Situ Scattering and Transmissometry (LISST), and hyperspectral sensors are needed. Sensor-based measurement can improve the spatial resolution of turbid water by measuring line and surface unit data. In addition, in the case of LISST-200X, it is possible to collect data on particle size, etc., so it can be used in the Turbidity-SS conversion equation for fraction (Clay: Silt: Sand). In addition, among recent remote sensing methods, the spatial distribution of turbid water can be presented when using UAVs with higher spatial and temporal resolutions than other payloads and hyperspectral sensors with high spectral and radiometric resolutions. Therefore, in this study, the Turbidity-SS conversion equation was calculated according to the fraction through laboratory analysis using LISST-200X and YSI-EXO, and sensor-based field measurements including UAV (Matrice 600) and hyperspectral sensor (microHSI 410 SHARK) were used. Through this, the spatial distribution of turbidity and suspended sediment concentration, and the turbidity calculated using the Turbidity-SS conversion equation based on the measured suspended sediment concentration, was presented. Through this, we attempted to review the applicability of the Turbidity-SS conversion equation and understand the current status of turbid water occurrence.