• Title/Summary/Keyword: Deterioration Diagnosis

Search Result 348, Processing Time 0.028 seconds

A Study on Conservation Management Systems based on Deterioration Diagnosis of the Fossil Site: Tracksite of Dinosaurs and Pterosaurs in Sanbuk-dong, Gunsan, Korea (화석지 손상도 정밀진단 기반 보존관리체계 연구: 군산 산북동 공룡발자국과 익룡발자국 화석산지)

  • Hye Ri Yang;Gyu Hye Lee;Chan Hee Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.675-695
    • /
    • 2023
  • The tracksite of dinosaurs and pterosaurs in Sanbuk-dong of Gunsan is the largest early Cretaceous dinosaur footprint fossil site in Korea, and all the footprints are important evidence indicating that large ornithopod and theropod dinosaurs inhabited the Korean peninsula during the early Cretaceous. The Sanbuk-dong site was covered with waterproof sheet in an outdoor environment until the installation of a protective enclosure in 2021. As a result, various factors such as shear force, load reduction, temperature and humidity fluctuations, acid rain, salinity and microorganisms have complexly interacted in the substrate of fossils, exacerbating the damage to footprints. For 159 footprints in 12 trackways among the footprints found in the site, the damage types were classified in detail and the level of each damage was assessed. The damages were classified into 6 types through the classification of deterioration degree of individual footprints. As a result of ultrasonic physical property evaluation on the surface of the fossil site, most of these footprints are in the completely weathered (CW) stage. Furthermore, various weathering patterns were observed in the study area, and surface contaminants were analyzed along the stratigraphy. Although the patterns of freshness and contaminants varied at different points within the fossil site, the chemical compositions were similar. Based on the results, an efficient conservation management system for dinosaur footprint fossils was established, and a conservation treatment type for each footprint was proposed.

Relationship between the Tidal Range in Sea Level and Damage of Domestic Port Facility (해수면 조위차와 항만시설물의 손상과의 관계 분석)

  • Binna Lee;Jong Suk Lee;Sung Jin Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.55-61
    • /
    • 2023
  • In this study, a basic research was conducted to establish a maintenance plan considering the environmental factors and deterioration characteristics of port facilities. The precise safety diagnosis reports for Incheon and Busan port facilities were referenced to examine the extent of deterioration and damage. The relationship with the degradation environmental assessment presented in the current guidelines was also analyzed. The analysis of the damage level of Incheon and Busan port facilities revealed that Incheon Port exhibited approximately three times higher damage rate compared to Busan Port. In the case of Incheon Port, reinforcement corrosion and external damage showed similar proportions, while in Busan Port, reinforcement corrosion had a higher proportion compared to external damage. On the other hand, when comparing with the degradation environmental assessment presented in the guidelines, it was found that there were some limitations in performing quantitative evaluation based on the guidelines for assessing port facilities. Therefore, an analysis based on tidal range was conducted by referring to existing literature. The analysis of tidal range in Incheon and Busan regions showed that Incheon had approximately five times higher difference compared to Busan. It is considered that this can be utilized as a differentiated item from existing degradation environmental assessment criteria.

A Research on Applicability of Drone Photogrammetry for Dam Safety Inspection (드론 Photogrammetry 기반 댐 시설물 안전점검 적용성 연구)

  • DongSoon Park;Jin-Il Yu;Hojun You
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.30-39
    • /
    • 2023
  • Large dams, which are critical infrastructures for disaster prevention, are exposed to various risks such as aging, floods, and earthquakes. Better dam safety inspection and diagnosis using digital transformation technologies are needed. Traditional visual inspection methods by human inspectors have several limitations, including many inaccessible areas, danger of working at heights, and know-how based subjective inspections. In this study, drone photogrammetry was performed on two large dams to evaluate the applicability of digital data-based dam safety inspection and propose a data management methodology for continuous use. High-quality 3D digital models with GSD (ground sampling distance) within 2.5 cm/pixel were generated by flat double grid missions and manual photography methods, despite reservoir water surface and electromagnetic interferences, and severe altitude differences ranging from 42 m to 99.9 m of dam heights. Geometry profiles of the as-built conditions were easily extracted from the generated 3D mesh models, orthomosaic images, and digital surface models. The effectiveness of monitoring dam deformation by photogrammetry was confirmed. Cracks and deterioration of dam concrete structures, such as spillways and intake towers, were detected and visualized efficiently using the digital 3D models. This can be used for safe inspection of inaccessible areas and avoiding risky tasks at heights. Furthermore, a methodology for mapping the inspection result onto the 3D digital model and structuring a relational database for managing deterioration information history was proposed. As a result of measuring the labor and time required for safety inspection at the SYG Dam spillway, the drone photogrammetry method was found to have a 48% productivity improvement effect compared to the conventional manpower visual inspection method. The drone photogrammetry-based dam safety inspection is considered very effective in improving work productivity and data reliability.

8 Years Report of Urine Organic Acid Analysis - Comparison before and after Introduction of Neonatal Screening Test using Tandem Mass Spectrometry - (소변 유기산 분석 8년의 정리 -탠덤매스(Tandem mass spectrometry)를 이용한 신생아 선별검사 도입 전후의 비교-)

  • Ahn, Seok Min;Shin, Woo Chul;Jeong, Han Bin;Seo, Young Jun;Jeong, Hwal Rim;Yoon, Jong Hyung;Bae, Eun Ju;Lee, Hong Jin
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 2018
  • Purpose: Disorders of organic acid metabolism have various clinical manifestations and it may be life-threatening. The prognoses of affected children are dependent on early diagnosis and treatment. We report this study to find out detection rate of referred samples, clinical manifestations and age distribution after introduction of neonatal screening test using tandem mass spectrometry in Hallym University Chuncheon Sacred Heart Hospital during 8 years and 9 months. Methods: The 2,794 patients referred from Jan. 2007 to Sep. 2015 were divided into four groups according to age. We conducted organic acid analysis of urine samples of patients and analyzed clinical manifestations and distributions of age at the diagnosis. For patients with ambiguous results, reanalysis of urine organic acid after diet restriction, protein loading and restriction, has been done. Results: A total of 626 patients with 20 disorders were diagnosed. Mitochondrial disorders (482 patients) were the most common diagnosis, followed by ketolytic defects (67), 3-hydroxyisobutyric aciduria (32), EPEMA syndrome (8), 3-methylcrotonyl glycinuria (7), glutaric aciduria type II (6) and type I (4), methylmalonic aciduria (3), isovaleric aciduria (3) and medium chain acyl-CoA dehydrogenase deficiency (3). Conclusion: As neonatal screening test using tandem mass spectrometry is increasingly common and medical environment is changed, detection rate of disorders of organic acid metabolism in this study has decreased compared to previous report. Because the deterioration can be prevented by early diagnosis and treatment, many pediatricians have to pay special attention to possibility of the disorders and make an effort for early diagnosis in clinical setting.

  • PDF

Spinal Cord Subependymoma Surgery : A Multi-Institutional Experience

  • Yuh, Woon Tak;Chung, Chun Kee;Park, Sung-Hye;Kim, Ki-Jeong;Lee, Sun-Ho;Kim, Kyoung-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Objective : A spinal cord subependymoma is an uncommon, indolent, benign spinal cord tumor. It is radiologically similar to a spinal cord ependymoma, but surgical findings and outcomes differ. Gross total resection of the tumor is not always feasible. The present study was done to determine the clinical, radiological and pathological characteristics of spinal cord subependymomas. Methods : We retrospectively reviewed the medical records of ten spinal cord subependymoma patients (M : F=4 : 6; median 38 years; range, 21-77) from four institutions. Results : The most common symptoms were sensory changes and/or pain in eight patients, followed by motor weakness in six. The median duration of symptoms was 9.5 months. Preoperative radiological diagnosis was ependymoma in seven and astrocytoma in three. The tumors were located eccentrically in six and were not enhanced in six. Gross total resection of the tumor was achieved in five patients, whereas subtotal or partial resection was inevitable in the other five patients due to a poor dissection plane. Adjuvant radiotherapy was performed in two patients. Neurological deterioration occurred in two patients; transient weakness in one after subtotal resection and permanent weakness after gross total resection in the other. Recurrence or regrowth of the tumor was not observed during the median 31.5 months follow-up period (range, 8-89). Conclusion : Spinal cord subependymoma should be considered when the tumor is located eccentrically and is not dissected easily from the spinal cord. Considering the rather indolent nature of spinal cord subependymomas, subtotal removal without the risk of neurological deficit is another option.

Meningoencephalitis in Dachshund Dog with Canine Distemper Virus Infection: 1.5 T and 7.0 T MRI Findings (닥스훈트견의 바이러스성 뇌수막염에서 1.5T와 7T 자기공명영상을 이용한 진단 증례)

  • Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.755-759
    • /
    • 2010
  • A 6-year-old, intact female Dachshund was presented with generalized seizure for 2 days. Based on the neurologic and physical examinations, intracranial diseases were suspected. 1.5T and 7.0T magnetic resonance imaging (MRI) of the brain were taken. The MRI results revealed diffuse hyperintense lesions in the area of the diencephalon to the medulla oblongata in the T2-weighted images. Canine distemper virus-induced meningoencephalitis was confirmed by the result of RT-PCR of the cerebrospinal fluid (CSF). The dog was euthanized 7 days after diagnosis due to poor prognosis and clinical deterioration. Postmortem histopathologic examination was consistent with the MRI findings. This is the first case report using 1.5T and 7.0T MRI to compare the virus-induced intracranial lesions in meningoencephalitis.

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

Surgical Treatments for Cervical Spondylotic Myelopathy Associated with Athetoid Cerebral Palsy

  • Lee, Yong-Jeon;Chung, Dong-Sup;Kim, Jong-Tae;Bong, Ho-Jin;Han, Young-Min;Park, Young-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.6
    • /
    • pp.294-299
    • /
    • 2008
  • Objective : To evaluate the clinical characteristics and surgical outcomes of the patients with cervical spondylotic myelopathy associated with athetoid cerebral palsy. Methods : The authors reviewed the clinical and neurodiagnostic findings, surgical managements and outcomes in six consecutive patients with cervical spondylotic myelopathy associated with athetoid cerebral palsy who had been treated with surgical decompression and fusion procedures between January 1999 and December 2005. The mean age of the 6 patients (four women and two men) at the time of surgery was 42.8 years (range, 31-55 years). The mean follow-up period was 56.5 months (range, 17-112 months). The neurological outcome was evaluated before and after operations (immediately, 6 months after and final follow-up) using grading systems of the walking ability, brachialgia and deltoid power. Results : At immediate postoperative period, after 6 months, and at final follow-up, all patients showed apparent clinical improvements in walking ability, upper extremity pain and deltoid muscle strength. Late neurological deterioration was not seen during follow-up periods. There were no serious complications related to surgery. Conclusion : Surgical decompression and stabilization in patients with cervical spondylotic myelopathy associated with athetoid cerebral palsy have been challenging procedure up to now. Our results indicate that early diagnosis and appropriate surgical procedure can effectively improve the clinical symptoms and neurological function in patients with cervical spondylotic myelopathy and athetoid cerebral palsy, even in those with severe involuntary movements.

Senescent Effects on Color Perception and Emotion

  • Han, Jeong-won;Kim, Bog G.;Choi, Inyoung;Park, Soobeen
    • Architectural research
    • /
    • v.18 no.3
    • /
    • pp.83-90
    • /
    • 2016
  • Senescent effects are the gradual deterioration of function caused by biological aging. Senescent effects on color vision are not clearly understood even after considerable researches. Part of the reason is that the color vision is a complex phenomenon resulting from various factors such as organic systems, and the physical (neuro-optical) and the psychological (experiential) processes of color perception. We performed a field experiment on color perceptional differences due to aging vision. Our experiment was applied to two different groups in South Korea: an experimental group (46 subjects of over the age of 61 years) and a control group (49 subjects in their twenties). The experimental tools are comprised of (1) six gradual yellowing detector board (40%, 50%, 60%, 70%, 80%, 90%); (2) pairs of vivid-strong, vivid-deep, grayish-deep, deep-dull, and bright-light tones of Blue (B) and Purple (P) colors; (3) Red (R), Yellow (Y), Green (G), Blue (B), and Purple (P) colors of dull-tones and pale-tones; and (4) a questionnaire on the semantic differential scales of the color images and color differences. A diagnosis system of gradual yellow vision, developed by the authors for this study, was adapted to generate the color detecting boards. The results are as follows. (1) There are significant differences between the two groups in detecting colors that simulate 40% and 50% of yellow vision. (2) As to the color difference detecting ability between similar tones, the experimental group shows difficulties in pairs of vivid-strong tones and deep-dull tones of the B color. And (3), the emotional responses to the dull tone and the pale tone are not stable in the red, the yellow, blue, and purple. Thus, we empirically demonstrate the specific differences in color perception between the old and young groups.

Development and use of Supporting Device for Patellar X-ray Imaging (슬개골 엑스선 영상 촬영을 위한 보조기구의 개발과 활용)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Lee, Sang-Hun;Kim, Jong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.165-171
    • /
    • 2020
  • In this study, it focuses on the development of radiographic devices for patellar imaging. On the previous X-ray examination of patella and patellofemoral joint, it analyzed the problems which could affect the results: unstable patients' pose, radiation exposure, and deterioration of image quality. The purpose of the research is to propose a future use of a developed device with an explanation of the process, function, and advantage of the device including the methods. The device is developed to focus on the diagnosis of the longitudinal and longitudinal fractures of the patella and patella/femoral joint, displacement such as dislocation, bone formation, stenosis of the patella/femorla joint, and cartilage wear. Due to the patient's anxious posture, it caused a shaking image, overlapping structures, and etcs, these factors challenge to diagnose accurately. In addition, the existing Settegast method and Hughston method, which are most frequently performed in the hospital field, are not suitable for the presence or absence of features or dislocation due to the heavy load on the patella of the patient. The developed device requires patients in a lying position and placing only their leg on the device, it increases the conveniences of the examination and decreases unnecessary radiation exposure of the patient except the patellar examination area. Moreover, one of the systems in the device fixes the detector, where the patients no longer need to hold the detector nor be in unstable posture, but describes the structure of the patella/femoral joint more clearly. Hoping the device will apply to more patients.