• Title/Summary/Keyword: Deterioration Diagnosis

Search Result 349, Processing Time 0.026 seconds

Concrete bridge deck deterioration model using belief networks

  • Njardardottir, Hrodny;McCabe, Brenda;Thomas, Michael D.A.
    • Computers and Concrete
    • /
    • v.2 no.6
    • /
    • pp.439-454
    • /
    • 2005
  • When deterioration of concrete is observed in a structure, it is highly desirable to determine the cause of such deterioration. Only by understanding the cause can an appropriate repair strategy be implemented to address both the cause and the symptom. In colder climates, bridge deck deterioration is often caused by chlorides from de-icing salts, which penetrate the concrete and depassivate the embedded reinforcement, causing corrosion. Bridge decks can also suffer from other deterioration mechanisms, such as alkali-silica reaction, freeze-thaw, and shrinkage. There is a need for a comprehensive and integrative system to help with the inspection and evaluation of concrete bridge deck deterioration before decisions are made on the best way to repair it. The purpose of this research was to develop a model to help with the diagnosis of concrete bridge deck deterioration that integrates the symptoms observed during an inspection, various deterioration mechanisms, and the probability of their occurrence given the available data. The model displays the diagnosis result as the probability that one of four deterioration mechanisms, namely shrinkage, corrosion of reinforcement, freeze-thaw and alkali-silica reaction, is at fault. Sensitivity analysis was performed to determine which probabilities in the model require refinement. Two case studies are included in this investigation.

Simplified Machine Diagnosis Techniques Using ARMA Model of Absolute Deterioration Factor with Weight

  • Takeyasu, Kazuhiro;Ishii, Yasuo
    • Industrial Engineering and Management Systems
    • /
    • v.8 no.4
    • /
    • pp.247-256
    • /
    • 2009
  • In mass production industries such as steel making that have large equipment, sudden stops of production process due to machine failure can cause severe problems. To prevent such situations, machine diagnosis techniques play important roles. Many methods have been developed focusing on this subject. In this paper, we propose a method for the early detection of the failure on rotating machine, which is the most common theme in the machine failure detection field. A simplified method of calculating autocorrelation function is introduced and is utilized for ARMA model identification. Furthermore, an absolute deterioration factor such as Bicoherence is introduced. Machine diagnosis can be executed by this simplified calculation method of system parameter distance with weight. Proposed method proved to be a practical index for machine diagnosis by numerical examples.

The Standardized Methods for Improvement of Maintenance Deterioration caused by Fire damage (국제 표준화를 위한 화재이후의 유지관리 시스템 개발)

  • Kwon, Young-Jin;Koo, In-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.230-231
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

The Standardized Methods for Improvement of Maintenance and Performance Construction of Deterioration caused by Fire damage (화재피해 콘크리트의 유지관리 및 시공성능 향상을 위한 표준화방안)

  • Seo, Dong-Goo;Kim, Dong-Eun;Kim, Bong-Chan;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.16-18
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

A Study on Monitoring Means of Insulation deterioration of Electric Power Cable (전력케이블 열화 감시방안에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun;Ryu, Ki-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

A Realization of Real Time Algorithm for Fault and Health Diagnosis of Turbofan Engine Components (터보팬엔진의 실시간 구성품 결함 및 건전성 진단 알고리즘 구현)

  • Han, Dong-Ju;Kim, Sang-Jo;Lee, Soo-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.10
    • /
    • pp.717-727
    • /
    • 2022
  • An algorithm is realized for estimating the component fault and health diagnosis such as a deterioration. Based on the turbofan engine health diagnosis model, from the health parameters which are estimated by a real time tracking filter, the outliers are eliminated efficiently by an effective median filter to minimize an false alarm. The difference between the fault and deterioration trends is identified by the detection measure for abrupt change, thereby the clear diagnosis classifying the fault and the health condition is possible. The effectiveness of the algorithm for fault and health diagnosis is verified from the simulated results of engine component faults and deterioration.

A Study on the Improvement of Evaluation Method of Diagnosis-System for Exterior-Wall Deterioration by Infrared Thermography (적외선 탐사기를 이용한 외벽열화 진단시스템의 평가기법 향상에 관한 연구)

  • Kim, Moo-Han;Kwon, Young-Jin;Kang, Suk-Puo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.185-190
    • /
    • 1999
  • It is difficult to estimate for deterioration of exterior wall by infrared thermography, because of amount of infrared-ray radiation effected by environmental factors such as temperature properties of materials, the outside air and the amount of solar radiation. Therefore we measured the distribution of temperature by times in the same reinforced-concrete structure in order to reduce problems, occasioned by environmental factors, then we analyzed physical influence factors of the infrared thermography. It is the aim of this study to suggest basic data with regard to method of estimation-system for deterioration of exterior wall in reinforced-concrete structures.

  • PDF

A Study on Quantitative Analysis for Treeing Deterioration Diagnosis Using Acoustic Detection (음향탐지를 이용한 트리잉의 열화진단을 위한 정량적 분석에 관한 연구)

  • 이덕진;신성권;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.68-74
    • /
    • 1999
  • Ths paper does acoustic detection of partial discharge using acoustic sensor in polymer. Time sequential rreasurement of acoustic emission characteristic obtained acoustic sensor deal with statistics process. and 5 characteristic quantities were introduced into this paper. Resulting fann analysis of $\psi$-AEA-n pattern (phase-acoustic emission amplitude-pulse number) and AE quantities ,it can know useful statistics quantities that AE average inception amplitude TEX>$(\overline{AEA_{inc}})$ and AE average maximum amplitude TEX>$(\overline{AEA_{max}})$ make diagnosis of the middle stage of deterioration, AE pulse number and AE average maximum phase $(\overline{\theta{max}})$ make diagnosis of the last stage of deterioration. it obtained that these AE quantities are useful for dias,mosis deterioration form experiment results.esults.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage (재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kwon, Yung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the Properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spalling and examining engineering property.