• Title/Summary/Keyword: Deterioration Characteristics

Search Result 980, Processing Time 0.032 seconds

Durability Evaluation of Grout in Cablebolt System (케이블볼트 충전재의 내구성 평가)

  • Choi, Jung-In;Kim, Won-Keun;Jeon, Jae-Hyun;Lee, Seok-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.553-561
    • /
    • 2010
  • Like the shotcrete can be deteriorated by chemical compounds as service years increase, the grout which is used to fasten the cablebolt(rockbolt) system in the underground structures also can be deteriorated by chemical compounds such as sulphate and/or chloride contained in groundwater during service years. This can induce issues on the long term durability of cablebolt(rockbolt) system and consequently on the stability of underground structures. In this study, the deteriorations of long term durability of cement mortar grout by each chemical compound of sulphate or chloride are studied experimentally and also complex deterioration by the mix of sulphate and chloride is investigated. Based on the results obtained in this study, the characteristics and prediction of deterioration of long term durability of cement mortar grout for cablebolt(rockbolt) system are suggested.

  • PDF

The comparison and analysis on the phosphor degradation causes in ac PDP

  • Ha, Chang-Hoon;Jeong, Dong-Chul;Kim, Tae-Jun;Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.109-112
    • /
    • 2003
  • In this paper, we investigated the phosphor degradation characteristics on the ultra violet ray (UV) irradiation as well as ion bombardment. We propose a novel experiment method which is related with phosphor degradation causes. The phosphor deterioration experiments were made on the UV irradiation as well as ion bombardment. To carry out the experiment and compare the results, we made up the specific experimental setup. The results show that the deterioration by ion damage is more rigorous than that by vacuum ultra violet (VUV) on the phosphor efficiency.

  • PDF

A study on remove of deterioration layer on EDM of STD11 (합금공구강(STD 11)의 방전가공면 변질층 제거에 관한 연구)

  • Kim, Sei-Whan
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2007
  • This paper has comparatively analyzed the characteristics of the machined surface of a specimen made by machining Die Steel STD11 and a specimen obtained by W-EDM steel. If a press die is manufactured through W-EDM, products of shapes that cannot easily be made through machining can be manufactured easily. However, the life of the press die is significantly reduced compared with the press die made through machining. This is believed to be caused by the deformed layer that has occurred on the surface of the press die that was made through W-EDM. The roughness of the 2 specimens was measured, and it was learned that the distribution of the roughness of the specimen made through the 1st W-EDM was rough.

  • PDF

A Study on Sensing Characteristics of Carbon Nanotube Smart Composite Nano Sensors Based on Electrical Impedance Measurement (탄소나노튜브 스마트 복합소재의 전기적 임피던스 변화를 이용한 나노센서의 센싱 특성 연구)

  • Kang, I.P.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • To address the need for new intelligent sensing, this paper introduces nano sensors made of carbon nanotube (CNT) composites and presents their preliminary experiments. Having smart material properties such as piezoresistivity, chemical and bio selectivity, the nano composite can be used as smart electrodes of the nano sensors. The nano composite sensor can detect structural deterioration, chemical contamination and bio signal by means of its impedance measurement (resistance and capacitance). For a structural application, the change of impedance shows specific patterns depending on the structural deterioration and this characteristic is available for an in-situ multi-functional sensor, which can simultaneously detect multi symptoms of the structure. This study is anticipated to develop a new nano sensor detecting multiple symptoms in structural, chemical and bio applications with simple electric circuits.

  • PDF

The Impact of Total Radiation Flux on Organic Materials under LED Lighting

  • Kim, Ji Won;Lee, Jin Hwan;Kim, Kyu Lin;Ryu, Jae Hyung;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.36 no.4
    • /
    • pp.236-243
    • /
    • 2020
  • In this study, an accelerated aging experiment for fabric and paper was conducted using two light emitting diode(LED) sources with different wavelength characteristics, and the discoloration under each lighting type was examined. Hanji(Korean traditional paper) and related textiles showed more discoloration under blue LEDs, while the blue wool standard showed more discoloration under white LEDs. This, indicated that the deterioration varied depending on the sample color. The the effect of the light source on artifact deterioration was primarily related to the total radiation flux(expressed in mill watts), rather than the total luminous flux(expressed in lumens). In addition, the discoloration of the investigated artifacts was dependent on the color rendering of the lighting.

A Study on the Impact Factor of Bridges (교량의 충격계수에 관한 연구)

  • Youn, IIro;Ryu, Taek-Eun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.2
    • /
    • pp.161-166
    • /
    • 2004
  • The impact factor of bridges is analyzed based on experimental data to examine the characteristics of the dynamic responses of bridges. The experimental impact factors are compared with the impact factor of Korean Highway Design Specification and Japan T-load in terms of the span length. According to the superstructural types of bridges, the variation of the impact factor is analyzed. When vehicles are passing on a bridge, the dynamic effect acts on the bridge impact factor more than at the time of design because of the velocity of vehicles, the surface roughness reduction due to the deterioration of the bridge deck pavement, and the disconnection of the bridge entrance and the expansion joint. Because the actual value is greater than the expected value at the time of design, the dynamic response of the bridge accelerates the deterioration of the bridge due to the accumulation of fatigue, and the bridge's life-time is shortened and can have an influence on the serviceability and safety of the bridge.

  • PDF

Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-Woo;Kim, Seung-Gyu;Gu, Kyung-Chul;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2338-2340
    • /
    • 1999
  • In this paper measurements of AE (Acoustic Emission) signals caused by corona discharge were performed to analyze the electrical deterioration in oil. We also examined the relationship between discharge magnitude and peak-to-peak value of AE signals to diagnose the deterioration of liquid dielectrics. From these results, Vpp(peak to peak value) of AE signals was proportional to corona discharge magnitude. The main frequency band of AE signals in oil appeared to 130[kHz].

  • PDF

Chemical Resistance Characteristics of Concrete Surface Coating Agent with Flexibility (유연성을 갖는 콘크리트 표면보호재의 내화학적 특성)

  • Han, Sang-Hoon;Yoon, Ju-Yong;Lee, Byung-Ro;Hong, Ki-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • The purpose of this study is evaluate the ability of coating materials developed in order to prevent the durability deterioration of the concrete structure. Neutralization test, freezing and thawing test, and sulfate resistance test were performed in this study. Test results show that the developed coating material is effective against durability deterioration.

Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface (에폭시/고무 계면에서의 결함에 따른 부분방전 특성)

  • Kim, Dong-Uk;Kim, Jeong-Nyeon;Baek, Ju-Heum
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.