• Title/Summary/Keyword: Deteriorated concrete

Search Result 349, Processing Time 0.027 seconds

An Investigation and Evaluation of Steel Corrosion Due to Chlorides in Concrete Structure (염화물에 의한 철근콘크리트 구조물의 철근부식 정도의 조사 및 평가)

  • 문한영;이창수;김성수;김홍삼;이종상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.633-636
    • /
    • 1998
  • This study is performed for the purpose of obtaining the fundamental datum to analyse the cause of steel corrosion in concrete and establish the repair strategies of deteriorated reinforced concrete structures due to steel corrosion. To investigate the degree of concrete deterioration, soluble chloride content in harden concrete, the depth of carbonation, cover depth and compressive strength are measured. The progress of corrosion of concrete bridge is electrochemically evaluated. The result shows that in approximately 43% of the structures below -350mV(vs. CSE), the exessive chloride contents is a direct cause of steel corrosion in reinforced concrete structures.

  • PDF

An Exposure Experiment for the Evaluation of Corrosion Properties of Sewage Concrete Covered with Antibiotics (항균제를 도포한 하수시설 콘크리트의 생화학적 부식특성 평가를 위한 폭로시험)

  • Roh, Kyung-Min;Lee, Eui-Bae;Kim, Young-Duk;Lee, Byoung-Ky;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.73-76
    • /
    • 2006
  • Sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. To prevent biochemical corrosion of the sewage concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed. Recently, to evaluate biochemical corrosion properties of concrete, antimicrobial performance and resistance to sulfuric acid were investigated respectively. But, in this study, to evaluate it complexly, concrete specimen covered with antibiotics were exposed in the actual sewage environment and were investigated about corrosion properties after three months. As a result, weight change ratio, nature potential and sulfuric ratio of concrete covered with antibiotics were less than plain concrete.

  • PDF

An Experimental Study on the Supposed Heating Temperature of Exposed Concrete at High Temperature (고온에 노출된 콘크리트의 수열온도 추정을 위한 실험적 연구)

  • Jang Jea bong;Lee Eui Bae;Cho Bong Suk;Kim Yong Ro;Kwon Young Jin;Kim Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.157-160
    • /
    • 2004
  • If concrete structure is exposed to high temperature such as long-term fire, damages affecting partial or whole structure system may occur. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary. Especially, the amount of fire damage done to concrete depends on the materials, the standard design compressive strength of concrete, and heated temperature. So, the object of this study is to present data for supposed heated Temperature of deteriorated concrete by fire.

  • PDF

A Study on Maintenance of Deteriorated Bridge By Long-Term Displacement Monitoring (장기처짐계측에 의한 노후교량의 유지관리에 관한 연구)

  • Kyung, Kab Soo;Lee, Young Il;Lee, Hee Hyun;Park, Yong Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.194-204
    • /
    • 1998
  • This study was performed to suggest the proper maintenance method for the deteriorated gerber type PC box girder bridge by using the long term displacement monitoring data. For this study, the monitoring system which can measure the long term displacement and the concrete surface temperature was designed and operated. From the measurement and structural analysis results, the cause of the permanent deformation which the bridge has already was estimated, and based on this result, the allowable permanent displacement value at the hinge was suggested. From this study, it was known that the long term monitoring system can be applied to the active maintenance of the deteriorated bridge and the suggested allowable permanent displacement could be used for the maintenance of the bridge.

  • PDF

Experimental study on RC frame structures strengthened by externally-anchored PC wall panels

  • Choi, Seung-Ho;Hwang, Jin-Ha;Lee, Deuck Hang;Kim, Kang Su;Zhang, Dichuan;Kim, Jong Ryeol
    • Computers and Concrete
    • /
    • v.22 no.4
    • /
    • pp.383-393
    • /
    • 2018
  • Infill wall strengthening method has been widely used for seismic strengthening of deteriorated reinforced concrete (RC) frame structures with non-seismic details. Although such infill wall method can ensure sufficient lateral strengths of RC frame structures deteriorated in seismic performances with a low constructional cost, it generally requires quite cumbersome construction works due to its complex connection details between an infill wall and existing RC frame. In this study, an advanced seismic strengthening method using externally-anchored precast wall panels (EPCW) was developed to overcome the disadvantage inherent in the existing infill wall strengthening method. A total of four RC frame specimens were carefully designed and fabricated. Cyclic loading tests were then conducted to examine seismic performances of RC frame specimens strengthened using the EPCW method. Two specimens were fully strengthened using stocky precast wall panels with different connection details while one specimen was strengthened only in column perimeter with slender precast wall panels. Test results showed that the strength, stiffness, and energy dissipation capacity of RC frame specimens strengthened by EPCWs were improved compared to control frame specimens without strengthening.

Investigation of Salt Attack of Concrete Structures Exposed to Reclaimed Marine Land (해안매립지에 위치한 콘크리트구조물의 염해조사)

  • Kim, Seong-Soo;Cheong, Ran;Kim, Young-Ung;Kim, Young-Chul;Park, Kwang-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.835-840
    • /
    • 2002
  • Chloride ions have a tendency to penetrate into concrete and proceed the corrosion by depassivating rebar surface. Thus tire deteriorated concrete is subject to experience severe degrading of durability under marine environment. In this study, concrete structures exposed to reclaimed marine land wet-e investigate to find out the salt attack along with analysis and review of it's cause. Under the reclaimed marine land, the main causes of deterioration of concrete structures is the steel corrosion due to the Penetration of chlorides and the deterioration of outer concrete itself by chemical attack.

  • PDF

A Fundamental Study on the Steel Corrosion Due to Carbonation of Concrete (콘크리트의 중성화로 인한 철근의 부식에 관한 기초적 연구)

  • 이창수;윤인석;최성기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.203-206
    • /
    • 1998
  • In reinforced concrete carbonation of concrete leads to depassivation of the reinforcement, and hence to initiation of corrosion. As a result of carbonation accelerating experiment with using effect of wet-dry cycle and 15% concentration of CO ₂, the carbonation rate shows very distinct difference according to W/C ratio. OPC-40 estimated no carbonation depth, whereas OPC-60 estimated rapidly the carbonation rate. The comparative analysis of the carbonation rate accelerating depends on different kinds of cement shows fastest FAC-20. Also, highly W/C ratio's concrete shows low half-cell potential value and fast corrosion rate. During period for 14 weeks. corrosion rate was not severe. So, it can be concluded that only carbonation attack on concrete doesn't severly deteriorated except very poor qualitified concrete.

  • PDF

Freeze-Thaw Resistance of Blended Cement Concrete using Seawater (해수를 사용한 혼합시멘트계 콘크리트의 동결융해 저항성)

  • 문한영;김성수;이승태;김종필;박광필
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.725-730
    • /
    • 2002
  • The durability of concrete involves resistance to freeze-thaw action, corrosion, permeation, carbonation, chemical attack and so on. Generally, properties of concrete have been well understood under the separate action of these deterioration mechanisms. However, in practice, the degradation of concrete usually is the result of combined action of physical and chemical attack and can be accelerated by the combined action of several deterioration mechanisms. In the present study, to evaluate the combined deterioration by freeze-thaw action and seawater attack, ground granulated blast-furnace slag or silica fume concrete with water or seawater as mixing water was exposed to 210 cycles of freeze-thaw action. Tests were conducted to determined the relative dynamic modulus of elasticity and compressive strength. Furthermore, The XRD, SEM and EDS analysis were performed on the deteriorated part of concrete due to freeze-thaw action and seawater attack.

  • PDF

An Experimental Study on the Engineering Properties and B.P Test of Ready Mixed Concrete Using EEZ Sand and Crush Sand (부순모래와 EEZ모래를 혼합사용한 레미콘의 B.P실험 및 공학적 특성에 관한 연구)

  • Shin, Seung-Bong;Kim, Young-Sun;Kim, Young-Duck;Lee, Sung-Yon;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.105-108
    • /
    • 2006
  • Recently, trouble of sand supplying is occurred according to exhaustion of natural sand resources. Therefore various measures are proposed for solution of trouble of sand supply and crushed sand among measures is used as one of most universal measures. But because crushed sand have poor particle shape and plenty of mikes micro particle, the quality of concrete using crushed sand deteriorated. Therefore, this study evaluated engineering property of concrete with replacement ratio of crushed sand and EEZ sand applied evaluation result to fundamental data for quality control of concrete using crushed sand and EEZ sand and The result of this study have shown that quality of concrete using crushed sand and EEZ sand and The compressive strengh of concrete up to 50, 70% EEZ sand replacement by crush sand, nearly equal to that of general sand.

  • PDF

Technology for Controlling Biochemical Corrosion by Sulfur-oxidizing Bacteria of Sewage Concrete Construction applied Antimicrobial Concrete (항균 콘크리트를 적용한 정화조 및 하수처리 콘크리트 구조물의 황산화세균에 의한 생화학적 부식 저감 기술)

  • Kim, Do-Su;Khil, Bae-Su;Sohn, Yu-Shin;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.907-910
    • /
    • 2008
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biochemical reaction originated from sulfur-oxidizing bacteria. To prevent biochemical corrosion of the sewage concrete, antibiotics which inhibit growth of sulfur-oxidizing bacteria have to be developed and applied necessarily. In this study, we are going to introduce technology which biochemical corrosion of sewage facilities concrete could be controlled effectively by antibiosis of antimicrobial concrete

  • PDF