• Title/Summary/Keyword: Deteriorated Area

Search Result 287, Processing Time 0.026 seconds

A Study on the Change Characteristics of the Kookmin Housing Complex in Suyu 1-dong, Seoul (서울시 수유1동 국민주택단지의 변화특성에 관한 연구)

  • Lee, Seong-Woon;Kim, Kyuong-Yon;Jun, Byung-Kweon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.21-28
    • /
    • 2018
  • This study analyzed the physical characteristics and change characteristics of urban detached residential area. In the reality of South Korea in which the history of modern urbanization is not long, the densification that progressed together with sudden population growth without any consideration of city plans became to reveal many problems. Thereafter, apartment-centered large scaled development plans have been implemented until now as an alternative for the foregoing. As the residential environments of old downtown areas that were excluded from the development have been gradually deteriorated, large scaled re-development and reconstruction projects have been adopted as ways to solve the problems of the old downtown areas. On one hand, the development methods that damage the history of the detached housing areas have been resisted. With such a background, this study attempted the analysis of the change characteristics of the Kookmin Housing Complex in Suyu 1-dong, Seoul with a view to playing the role of evidentiary materials for the disappearing urban detached housing areas or those urban detached housing areas that may be revived. This author hopes and the results of this study will lead to careful development that presents measures to maintain and develop modern urban residential areas where the history of past residential areas and culture are disappearing due to full-scale redevelopment.

The First Case Study of TBM Pre-Excavation Type 2-Arch Tunnel in Korea (국내 최초 TBM선굴진 2-Arch터널 설계사례 연구)

  • Hyung-Ryul Kim;Sang-Jun Jung;Jun-Ho Kang
    • Tunnel and Underground Space
    • /
    • v.33 no.4
    • /
    • pp.255-264
    • /
    • 2023
  • As the demand for urban underground space increases recently, urban tunnel planning is actively progressing. In the urban area, a underground station is planned in consideration of the living environment of residents, and 2-arch tunnel is applied for the stability of existing structures and reduction of environmental damage. However, since the depth of weak rock mass is deeply distributed in the urban area due to severe weathering, careful planning is required to secure tunnel stability. In addition, if TBM mechanical excavation is applied as the main tunnel excavation method considering the composite ground in urban area, the construction connectivity with the 2-arch tunnel of the NATM concept may be deteriorated. In this study, the design case of applying TBM pre-excavation type 2-arch tunnel for the first time in Korea was mainly described. The main considerations for the segment design of TBM pre-excavation type 2-arch tunnel were explained for side tunnels. Also, a stability analysis was conducted to verify the effectiveness and adequacy of the TBM pre-excavation type 2-arch tunnel.

Development of simultaneous multi-channel data acquisition system for large-area Compton camera (LACC)

  • Junyoung Lee;Youngmo Ku;Sehoon Choi;Goeun Lee ;Taehyeon Eom ;Hyun Su Lee ;Jae Hyeon Kim ;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3822-3830
    • /
    • 2023
  • The large-area Compton camera (LACC), featuring significantly high detection sensitivity, was developed for high-speed localization of gamma-ray sources. Due to the high gamma-ray interaction event rate induced by the high sensitivity, however, the multiplexer-based data acquisition system (DAQ) rapidly saturated, leading to deteriorated energy and imaging resolution at event rates higher than 4.7 × 103 s-1. In the present study, a new simultaneous multi-channel DAQ was developed to improve the energy and imaging resolution of the LACC even under high event rate conditions (104-106 s-1). The performance of the DAQ was evaluated with several point sources under different event rate conditions. The results indicated that the new DAQ offers significantly better performance than the existing DAQ over the entire energy and event rate ranges. Especially, the new DAQ showed high energy resolution under very high event rate conditions, i.e., 6.9% and 8.6% (for 662 keV) at 1.3 × 105 and 1.2 × 106 s-1, respectively. Furthermore, the new DAQ successfully acquired Compton images under those event rates, i.e., imaging resolutions of 13.8° and 19.3° at 8.7 × 104 and 106 s-1, which correspond to 1.8 and 73 μSv/hr or about 18 and 730 times the background level, respectively.

Variation of Nutrients due to Long-Term Effects of Ocean Dumping and Spatial Variability of Water Quality Parameters in Summer at the Ocean Waste Disposal Site Off the West Coast of Korea (한국 서해 폐기물 투기해역의 하계 수질인자 분포특성과 장기 투기행위로 인한 영양염 농도 변화)

  • Koh, Hyuk Joon;Choi, Young Chan;Park, Sung Eun;Cha, Hyung Kee;Chang, Dae Soo;Yoon, Han Sam;Lee, Chung Il
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1389-1402
    • /
    • 2013
  • This paper focuses on the impacts of waste dumping on inorganic nutrients in the dumping area of the Yellow Sea, and the effect of an governmental regulation of pollution in dumping areas. The environmental variables and parameters of the dumping and reference areas in the Yellow Sea were measured during July 2009 and analyzed. In addition, the analyzed data for inorganic nutrients over the last 10 years were obtained from the Korea Coast Guard (KCG) and the National Fisheries Research and Development Institute (NFRDI). The chemical environment of the study area revealed increases in concentrations of inorganic nutrients, Chemical Oxygen Demand (COD), and Volatile Suspended Solids (VSS) in the bottom layer. On the contrary, the pH level was decreased. Most notably, the time series data of inorganic nutrients showed gradual increase over time in the dumping area, and thus, the oligotrophic waters trend toward eutrophic waters. The increases appears to be due to the disposal of large amounts of organic waste. In recent times, the wastes disposed at the area were largely comprised of livestock wastewater, and food processing waste water. The liquefied waste, which contains an abundance of nutrients, causes a sharp increase in concentrations of inorganic nitrogen in the dumping area. On the one hand, the dumping sites have been deteriorated to such an extent that pollution has become a social problem. Consequentially, the government had a regulatory policy for improvement of marine environmental since 2007 in the dumping area. Hence, the quality of marine water in the dumping site has improved.

Revised Soil Survey of Yangju City in Gyunggido

  • Hyun, Byung-Keun;Sonn, Yeon-Kyu;Kim, Keun-Tae;Cho, Hyun-Jun;Jung, Sug-Jae;Choi, Jung-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.2
    • /
    • pp.81-92
    • /
    • 2017
  • Recently, agricultural lands have decreased sharply, which was caused by huge housing site, urbanization, land consolidation, and road construction etc. In particular, Yangju city near Seoul city has the most severe land use change in Korea. Therefore, we analyzed changes of land use, soil properties, and soil information in order to provide the basic soil information and soil management practices in this city. The area of crop cultivated land in Korea (2015) reduced by 12,090 ha compared to ones from the previous year (2014). The paddy field decreased by 25,421 ha but, upland field increased by 13,331 ha. One of the reasons for the reduction of the paddy field was converting paddy field to upland (20,916 ha) > others (3,056) > building (2,571) > public facilities (847) > idle land (217). But, reasons for increase of upland field were switching paddy to upland (20,916 ha) > land developed (634). The main reason of converting paddy field to upland was changing from rice to more profitable speciality crops or pulses. The cropland area (paddy fields, upland, orchard) of Yangju city reduced by 1,412 ha (2015/2014). The ratio of cropland area in each city reduced by 22.9% dramatically compared 2015 to 1999. The paddy fields located in alluvial plains in Yangju city were changed into upland or green house. The drainage classes of soil have been deteriorated because the flows of water were intercepted by road construction and other disturbance to water flows. In particular, paddy fields have been changed to not only upland, orchard, greenhouse cultivation but also to fallow and soil dressing on paddy in Yangju city. To analyze result of soil survey of Yangju city, 858 soil codes (soil phases) were used and the area was 105.17ha. The number of soil series increased from 60 to 65, and that of soil phase increased from 105 to 124. The largest increased area was Noegog soil series. 125.7ha of Neogog soil series was incorporated from the existing Sachon, Yecheon and Eungog soil series. The soil suitability class of paddy field in Ogjung huge housing site of Yangju city was the 4th grade for 32.6% of the area. The soil suitability classes of upland were 2nd and 3rd grade for 72.4% of the area. Farm land with high quality should be conserved by related law.

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

Monitoring of Distribution System to Improve Tap Water Quality (수돗물 수질개선을 위한 배수관망시스템 관리 정책 - 수질모니터링을 중심으로 -)

  • Jun, Jesang;Kim, Jakyum
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.411-420
    • /
    • 2005
  • Maintaining a good quality of drinking water produced through appropriate water treatment processes to the tap is as important as improving water quality in a water treatment plant (WTP). The quality of most tap water, however, does not have the same quality as that of the water produced in a WTP due to the contamination in the distribution system while they are delivered through pipes and water tanks. It is very important to maintain water quality in distribution system to water suppliers for consumer's health and safety. Furthermore, it is not possible to investigate the water quality of all points in the distribution system because the system has a wide area and very complex hydraulic characteristics. One economic solution to prevent water quality in distribution system from being deteriorated is monitoring several points that might have the least water quality in the distribution system. If the quality of water of the monitoring points selected by proper ways is better than the quality index of Drinking Water Quality Guidelines suggested by Korean Ministry of Environment, all other points in the distribution system would be safe to drink.

A Study on the Numerical Model of Current of Strafication Considering the Topographic Heat Accumulation Effect in the Coastal Area (해역에서의 지형성 저열효과를 고려한 성층유동 수치모델에 관한 연구)

  • Yoon, Jung-Sung;Kim, Myoung-Kyu;Han, Dong-Jing;Kim, Ga-Ya
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.5
    • /
    • pp.61-68
    • /
    • 2008
  • In Jinhae-Masan bay, a typical semi-dosed bay in Korea, the water quality is severely deteriorated because of the dosed topographic character and the inflow of nutrients from the land. There have been attempts to apply a water quality model dealing with the entrophication phenomenon and the oxygen-deficient mass in the bay in summer, but there have been few examples of models that have considered the phenomenon of stratification in the proper order, and then it is performed the model of water quality. Therefore, this study collected and analyzed the pre-observed water temperature data from Jinhae-Masan bay in summer and then constructed a density model using the topographic heat accumulation effect and inflow from the river to examine the temperature stratification. The simulation results show that this model could demonstrate the temperature stratification in the Jinhae-Masan bay very well.

Numerical Design of Light-off Auto-Catalyst for Reducing Cold-Start Emissions (냉간시동시 자동차용 저온활성촉매의 성능 향상을 위한 수치적 설계)

  • Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1264-1276
    • /
    • 2000
  • Light-off catalyst has been used for minimization of cold-start emissions. Improved cold-start performance of light-off catalyst needs the optimal design in terms of flow distribution, geometric surface area, precious metal loading, cell density and space velocity. In this study, these influential factors are numerically investigated using integrated numerical technique by considering not only 3-D fluid flow but also heat and mass transfer with chemical reactions. The present results indicate that uneven catalyst loading of depositing high active catalyst at upstream of monolith is beneficial during warm-up period but its effect is severely deteriorated when the space velocity is above 100,000 $hr^{-1}$ To maximize light-off performance, this study suggests that 1) a light-off catalyst be designed double substrate type; 2) the substrate with high GSA and high PM loading at face be placed at the front monolith; and 3) the cell density of the rear monolith be lower to reduce the pressure drop.

A Basic Study on Connectivity of Urban Parks for the Urban Ecological Network Establishment (도시생태네트워크 구축을 위한 도시공원의 연결성 평가 기초 연구)

  • Sung, Hyun-Chan;Kim, Mi-Ri;Hwang, So-Young;Kim, Su-Ryeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.2
    • /
    • pp.125-136
    • /
    • 2014
  • Urban Green Area has ecologically deteriorated along with quantitative loss, being developed as a dot itself rather than connected to forests and green networks around the park. The present study aims to propose a connected plan on Urban Ecological Network establishment through 'assessment of the connectivity of the entire urban parks' in accordance with distance of forest and river and 'assessment of trends in connection fragmentation of urban parks' in accordance with the past change of forest and river. According to the result of this study, criteria based on previous research was "directly linked type is less than 300m, conceptually linked type is between 300m to 1km, the isolated type is greater than 1km". And the result of 'assessment of the connectivity of the entire urban parks' is analyzed as the rate of park and green network, 41.7% in Suwon, 80.0% in Seongnam, 88.9% in Namyangju on the basis of office and field investigation. Also, according to the result of 'assessment of trends in connection fragmentation of urban parks', consideration for connection to the original forest is insufficient.