• Title/Summary/Keyword: Detention Reservoir Operation

Search Result 9, Processing Time 0.023 seconds

A Technique of Inland Drainage Control Considering flood Characteristics of the Han River (한강홍수특성을 고려한 내배수 처리기법)

  • Lee, Won Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.99-108
    • /
    • 1991
  • Rapid changes of urban hydrologic events need new management operation rule of detention reservoir which is essential outflow control system in urban area. Therefore, this study is to develop the outflow management method of Seoul city considering the Han river flood characteristics, to analyze the inundation of detention reservoir according to variation of design storm patterns, and to examine the safety of gate due to design flood water level. From this study, new operation rule is presented. The design storm patterns are determined by instantaneous intensity method and Huff's quartile method. And the inflow hydrograph of detention reservoir is obtained by applying ILLUDAS model and RRL method. The operation rule of existing drainage pump is designed to have linear relation between storage and pumping discharge. But in this study, it is effective for preventing inundation when the operation rule of drainage pump have Gaussian function which is combined the storage of detention reservoir with its inflow according to increasing or decreasing of inflow hydrograph.

  • PDF

Effects of the water level reduction and the flow distribution according to change of the side weir location in detention reservoir (홍수조절지 횡월류위어의 위치 변화에 따른 수위 저감 및 유량 분담 효과)

  • Seong, Hoje;Park, Inhwan;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.555-564
    • /
    • 2018
  • The detention reservoir is a hydraulic structure that constructs a levee on the inland of river and sets up side weir in a section of the levee, and this facility stores a part of the flood volume in case of a flood event over a certain scale. In order to optimize the operation of detention reservoir, it is necessary to review the linkage with existing facilities in the river. In this study, the effect of water level reduction and the flow distribution was analyzed according to the location of the side weir in the detention reservoir considering the run-of-the-river gate. Two radial gates were installed in the experimental channel, and the water level in channel and the overflow of weir were measured by moving the location of the side weir upstream from the gate. As a results of experiment, it was confirmed that the water level reduction is more remarkable as the location of the side weir was closer to the gate, and the effect of flow distribution is not greatly changed. When two or more side weirs were operated, it is confirmed that the sufficient storage space was secured and the water level reduction effect with the location of the side weir is not large. In addition, the water level reduction rate according to the location of the side weir was estimated by empirical formula and it is provided as basic data that can be used in the planning of the detention reservoir.

Determination of operating offline detention reservoir considering system resilience (시스템 탄력성을 고려한 빗물저류조 운영수위 결정)

  • Lee, Eui Hoon;Lee, Yong Sik;Jung, Donghwi;Joo, Jin Gul;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.403-411
    • /
    • 2016
  • Recently, the number of occurrences of inundation and the severity of flood damage has increased rapidly as the frequency of localized heavy rainfall and the ratio of impervious area increased in urban areas. Most local governments focus on employing structural measures (e.g., the construction of detention reservoirs/pump stations, rehabilitation of drainage and sewer pipes) to prevent urban inundation. On the other hand, the effectiveness of implementing such structural measures is being dimished because there are already many inundation prevention facilities. The limitation of structural measures can be overcoming by employing non-structure measures, such as flood alerts and the operation of drainage facilities. This study suggests the pump operation rule (i.e., suggesting pump stop level) for a new detention reservoir operating method, which triggers the operation of a pump based on the water level at the monitoring node in urban drainage system. In the new reservoir operation, a total of 48 rainfall events are generated by the Huff distribution for determining the proper pump stop level. First, the generated rainfall events are distributed as frequencies, quartiles, and durations. The averaged system resilience value was determined to range from 1.2 m to 1.5 m is based on the rainfall-runoff simulation with rainfall generated by the Huff distribution. In this range, 1.2 m was identified considering the safety factor of 1.25 by the Standard on sewer facilities in 2011.

Practical Research on the Advanced Detention Pond for the Improvement of Water Quality of Agricultural Reservoir (농업용저수지의 수질개선을 위한 오염물질 침강지 조성 기법)

  • Pae, Yo Sop;Nam, Gui Sook
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.79-86
    • /
    • 2008
  • To improve water quality for agricultural use, it is needed to introduce the natural and low-cost self-purification system. It is also necessary to develop the water purification facilities for more efficient and convenient design, construction, operation and management. This study aims to develop the practical facilities to improve water quality for agricultural use. The practical detention pond system, which uses artificial floating island and shield skirts with bio-media, enhanced removal efficiencies of SS, TN and TP more particularly than the detention pond using an auxiliary dam. The removal efficiencies SS, TN and TP for the practical detention pond were 55.7%, 61.0% and 55.9%, respectively. The facilities of the practical detention pond has a lot of disadvantages such as the low-cost and high efficiency as well as uncountable impacts regarding ecology and landscape. However, an auxiliary dam is recommended to be installed in shallow depth due to low efficiency.

  • PDF

A study on the measures to use Gunnam flood control reservoir through a reservoir simulation model (저수지 모의 모형을 통한 군남홍수조절지의 활용방안에 관한 연구)

  • Yang, Wonseok;Ahn, Jaehwang;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.407-418
    • /
    • 2017
  • Due to geographical features of being close to DPRK (Democratic People's Republic of Korea), the Imjin River basin has difficulties in hydrological observation, and is vulnerable to unexpected flood occurrence. As a countermeasure, Gunnam Flood Control Reservoir construction was planned in 2005. Despite such a structural measure, damages by DPRK's illegal release continues to occur. Futhermore the Imjin River's flow has been decreased due to the effect of continuous drought in the Korean Peninsula since 2012 and DPRK's unilateral storage of water. A new operation method is derived for the Gunnam Flood Control Reservoir in order to cope with drought damages on the Imjin River basin and to ensure efficient response time upon flooding. The operation method maintaining Gunnam Flood Control Reservoir's water level by raising from EL.23.0 m to EL.31.0 m during the flood season for securing reservoir capacity enables to secure additional $14,000,000m^3$ water compared to the existing operation methods. The operation method to store inflow by controlling release to $250m^3/s$ in the early stage of flood has increased 2.66% on average in terms of detention effect of reservoir compared to the existing operation methods. The method enables to secure 19 hours to prepare flood compared to the existing methods.

Alternatives for The Stable Operation of Wastewater Treatment Plant in Combined Sewer System during Wet Weather (합류식 하수관거 지역에서 강우시 하수처리장 적정운영방안에 관한 연구)

  • Lee, Doo-jin;Shin, Eung-Bai;Hong, Chul-ui;Ahn, Se-young
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.132-144
    • /
    • 2004
  • The purpose of this study was to evaluate alternatives for stable operation of WWTP(Wastewater Treatment Plant) with a higher rate of inflows and a higher concentration of pollutants during wet weather to minimize the pollution loads being discharged into receiving waters. 3Q(Q: dry weather flow) of a base flow is normally intercepted and flows into WWTP as it was current practice. It is revealed by simulation that the bypassing alternative of 1Q through secondary treatment and 2Q into the stream after primary treatment was as good as it is expected. The bypass pollution loads were in the range of 23.9 ~ 38.5 % of the total loads flowing into the WWTP indicating that the bypassed flows need an extra treatment such as stormwater detention reservoir, high-rate coagulation with sedimentation, and step-feed. The high-rate coagulation with sedimentation was the most effective with respect to removal of the pollution loads.

A Study on the Design Factors of the Cylinder-Shaped Filter for Improving Reservoir Water Quality (호소수질 개선을 위한 원통형 여과장치의 설계요소 연구)

  • Lee, Sun-Ho;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.655-662
    • /
    • 2009
  • In order to obtain knowledge on the design and operation of practical?scale Cylinder-Shaped Filters, pilot experiments were conducted to observe the effects of stepwise augmentation of production rate on water quality and clogging. A production rate increase from 0.8 L/min to 2.4 L/min did not appear to affect the removal efficiencies of BOD(Biochemical Oxygen Demand), SS(Suspended Solids), and turbidity, as the values were maintained around 80%, over 95%, and over 90% respectively;however, COD(Chemical Oxygen Demand) removal decreased from 44% to 29%. In addition, results indicated an inverse relationship between production rate and detention time required to remove unit contaminant concentration, the observed detention time in the filter to remove 1 mg-COD/L being 83 minutes for the production rate of 0.8 L/min and 45 minutes for the production rate of 2.4 L/min, suggesting that a relatively higher production rate is likely to be more advantageous in the purification of reservoir water when compared to a lower production rate. Clogging was observed to originate from the surface and advance to the center of the filter, and although clogging seemed to increase as the production rate increased, this did not cause any difficulties in normal functioning of the filter for more than 2 years of operation, suggesting that this filter system can be used effectively in the purification of reservoir water.

A New Control Technique of Drainage Pump Based on Fuzzy Control (퍼지제어기법을 사용한 우수배제 펌프의 조작기법 개발)

  • Lee, Won Hwan;Cho, Won Cheol;Shim, Jae Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.107-114
    • /
    • 1992
  • With the increasing of impervious area and shortening of travel time, the risk of flooding in urban area becomes a serious problem in Seoul metropolitan area, and its alternatives are needed. In this study, one of urban flood alternatives, a fuzzy control technique is applied in pumping station to test its drainage capacity of inland inflow, and compared with existing pumping criteria (controled by water level). Three design rainfalls(10, 30, and 50 year) are applied to ILLUDAS model to calculate inflow in detention reservoir. To check the efficiency of fuzzy control, two fuzzy rules are used in the operation of pumping station. In these results, fuzzy control rules, based on the experiences of experts, show applicability in practice and effectiveness in inland flooding prevention.

  • PDF

Improvement and Application of Pump Station Operating System and Economic Analysis of the Application (빗물펌프장 운영시스템 개선 및 적용과 경제효과분석)

  • Joo, Jin- Gul;Yoo, Do-Guen;Yang, Jae-Mo;Jung, Dong-Hwi;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • In low-lying districts of urban areas, pump stations were built to protect flooding by the heavy rain. Particularly, the automatic pump operation system was installed for efficiency in the pump stations of Seoul. However, the effective pump operation is difficult under existing operating system because the system only performs operation by reservoir depth. This study would like to improve the real time operating system suggested by Jun et al.(2007) and to apply the system Gasan 1 pump station in Seoul. For various design rainfall events, maximum water levels simulated by the suggested system were 10~70cm lower than results by the existing system. And overflow volume at upstream manholes were 50% reduced. We converted the flood control effects by establishment of the suggested system to economic indicators. To obtain the same effect, approximately 4.9 billion won needs to expand pump capacities or 3.2~6.9 hundreds million won needs to construct storm water detention on upstream area. The suggested system could improve the flood control stability by efficient operation of the existing pump station.