• 제목/요약/키워드: Detector position

검색결과 376건 처리시간 0.025초

Detector Foil Self-Shielding Correction Factors

  • Kwon, Oh-Sun;Kim, Bong-Ghi;Suk, Ho-Chun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.197-201
    • /
    • 1996
  • In the detail reaction-rate measurements in a critical assembly using the foil activation method, the measured activations of detector foils have inevitably errors caused by detector foil self-shielding effect. If neutron flux could be approximated to Westcott flux: i.e. well thermalized Maxwellian distribution, these activations of detector foil could be corrected to represent the unperturbated flux at any detected position in the cell with using Westcott option and reaction-rate option of the lattice code, WIMS-AECL. These calculated detector material self-shielding correction factors of the tested fuel, CANFLEX provided much information about neutron spectrum of test lattice cell as well as the correction factors themselves. The results could be verified by another lattice calculations.

  • PDF

배열형 실리콘광증배소자를 이용한 포톤 카운팅 검출기 설계를 위한 몬테칼로 시뮬레이션 연구 (Monte-carlo Simulation for X-ray Photon Counting using MPPC Arrays)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.929-934
    • /
    • 2018
  • 영상의 질 향상과 물질 분석 등을 위해 엑스선을 카운팅하여 검출하기 위한 연구가 활발하다. 본 연구에서는 MPPC 어레이를 사용하여 엑스선 포톤 카운팅을 위한 검출기를 설계하였고, 시뮬레이션을 통해 검출기 특성을 평가하였다. GATE를 사용하여 엑스선과 섬광체와 반응한 위치 정보를 획득하였고, 이 정보를 DETECT2000의 빛 발생 위치로 사용하였다. 0.5 mm와 1 mm 두께의 GAGG 섬광체를 사용하였으며, $4{\times}4$ 어레이의 MPPC를 통해 발생된 빛을 획득하였다. 각 채널별로 획득한 빛의 신호를 통해 영상을 재구성하여 설계한 검출기의 분해능을 확인하였다. 0.5 mm와 1 mm 두께의 GAGG 섬광체에서 모두 2 lp/mm 이상의 영상을 획득하였다. 본 검출기를 엑스선 시스템에 사용할 경우 포톤 카운팅이 가능한 저비용의 시스템을 구축할 수 있을 것이다.

고장위치 검출 가능한 BIST용 패턴 발생 회로의 설계 (Design of Fault Position Detectable Pattern Generator for Built-In Self Test)

  • 김대익;정진태;이창기;전병실
    • 한국통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.1537-1545
    • /
    • 1993
  • 본 논문에서는 RAM의 Built-In Self Test(BIST)를 수행하기 위하여 제안되었던 Column Weight Sensitive Fault(CWSF) 테스트 알고리즘과 비트라인 디코더 고장 테스터 알고리즘에 적합한 패턴발생회로와 고장위치 검출기를 설계하였다. 패턴발생 회로는 어드레스 발생부와 데이터 발생부로 구성되었다. 또한 어드레스 발생부는 실효 어드레스를 위한 행 어드레스 발생부와 순차 및 병렬 어드레스를 위한 열 어드레스 발생부로 나누어져 있다. 고장위치 검출기는 고장발생의 유, 무와 그 위치를 찾기위해 구성되었다. 설계한 회로들의 검증을 위하여 각 부분 및 전체적인 시뮬레이션을 통하여 동작을 확인하였다.

  • PDF

DFT에 의한 회전자 위치 검출 방법을 사용한 레졸버 인터페이스에 관한 연구 (A Study on the Resolver Interface using a Rotor Position Detector Method with DFT)

  • 황락훈;나승권;최기호
    • 한국산학기술학회논문지
    • /
    • 제12권10호
    • /
    • pp.4550-4560
    • /
    • 2011
  • 전동기를 제어하기 위한 속도를 검출하는 장치로 일반적으로 광학적 엔코더가 많이 사용되고 있으며 레졸버는 구조적으로 엔코더를 전동기에 장착하기가 어려운 경우에 사용하고 있다. 따라서 레졸버는 엔코더와 비교하여 가격면에서 불리하지만 회전자의 절대위치를 검출하기 때문에 자극의 위치를 기준으로 제어하는 경우에 유용하다. 본 연구는 레졸버에 의한 전동기의 회전속도 및 위치를 검출하는 방법으로 최소한의 하드웨어인 필터를 사용하고 프로그램에 의한 디지털방법의 속도검출기에 관한 것이다.

미소 변위 진동측정을 위한 광학 시스템 설계 및 제작 (Noncontact optical system for measurement of displacement and vibration)

  • 황웅;권진혁
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.260-265
    • /
    • 2003
  • 미세하게 진동하는 물체의 변위를 비접촉식으로 측정할 수 있는 광학계를 설계하고 제작하였다. 도플러효과에 의한 방법과는 달리, 하나의 볼록렌즈를 이용하여 물체 표면에 비스듬하게 입사하여 물체 표면에서 반사되는 광점의 위치 변화를 PSD(position-sensitive detector)로 검출하였다. 이러한 방법으로 전체적인 장비의 크기를 작게 하였고 빠른 응답 속도를 구현하였다. 본 장비는 $\pm$1.0 $\mu\textrm{m}$의 분해능을 나타내었으며, 스피커의 진동 실험 및 CD-ROM안에서 회전하는 C교의 진동을 측정하였다.

Detector Mount Design for IGRINS

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyoung;Lee, Hanshin;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권2호
    • /
    • pp.177-186
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

최대우도함수를 이용한 양전자방출단층촬영기기의 검출기 모듈의 디지털 위치 획득 방법 (Digital Position Acquisition Method of PET Detector Module using Maximum Likelihood Position Estimation)

  • 이승재;백철하
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2021
  • 양전자방출단층촬영기기에서 영상을 획득하기 위해서는 동시 측정된 검출기 모듈의 섬광 픽셀의 위치 좌표를 서로 연결하는 과정이 필요하다. 이를 위해서 다수의 섬광 픽셀과 소수의 광센서를 사용하는 검출기 모듈에서는 평면 영상을 획득하여 각 섬광 픽셀의 영역을 나누어 감마선과 상호작용한 섬광 픽셀의 위치를 획득해야 한다. 또는 사용하는 섬광 픽셀의 수와 광센서의 수를 동일하게 구성할 경우는 섬광 픽셀 위치에 대한 위치 좌표를 직접 디지털 신호 좌표로 획득할 수 있다. 다수의 섬광 픽셀과 소수의 광센서를 사용하는 방법은 평면 영상 획득과 영역을 나누는 과정이 필요하며, 디지털 신호 좌표를 직접 획득하는 방법은 다수의 광센서와 신호처리 시스템이 필요하다. 이는 신호처리 과정이 복잡해지며, 비용이 상승하는 문제가 발생한다. 이를 해결하기 위해 본 연구에서는 다수의 섬광 픽셀과 소수의 광센서를 사용하여 평면 영상 및 영역의 분리과정을 수행하지 않고 디지털 신호 좌표를 획득하는 방법을 개발하였다. 최대우도함수를 사용하여 각 섬광 픽셀에서 획득한 신호를 통해 작성된 순람표를 통해 감마선과 상호작용한 섬광 픽셀의 위치 좌표값을 디지털 신호로 획득하는 방법이다. DETECT2000을 사용하여 시뮬레이션을 실시하였으며, 제시한 방법에 대해 검증을 실시하였다. 그 결과 모든 섬광 픽셀에서 정확한 디지털 신호 좌표를 획득할 수 있었으며, 이를 기존 시스템에 적용할 경우 신호처리 과정의 단순화로 보다 빠른 영상획득이 가능할 것으로 판단된다.

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제12권2호
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

Iris Pattern Positioning with Preserved Edge Detector and Overlay Matching

  • Ryu, Kwang-Ryol
    • Journal of information and communication convergence engineering
    • /
    • 제8권3호
    • /
    • pp.339-342
    • /
    • 2010
  • An iris image pattern positioning with preserved edge detector, ring zone and clock zone, frequency distribution and overlay matching is presented in this paper. Edge detector is required to be powerful and detail. That is proposed by overlaying Canny with LOG (CLOG). The two reference patterns are made from allocating each gray level on the clock zone and ring zone respectively. The normalized target image is overlaid with the clock zone reference pattern and the ring zone pattern to extract overlapped number, and make a matched frequency distribution to look through a symptom and position of human organ and tissue. The iterating experiments result in the ring and clock zone positioning evaluation.