• Title/Summary/Keyword: Detection technique

Search Result 4,097, Processing Time 0.041 seconds

Increment Method of Radar Range using Noise Reduction (잡음 감소 기법을 활용한 레이다의 최대 거리 향상 기법)

  • Lee, Dong-Hyo;Chung, Daewon;Shin, Hanseop;Yang, Hyung-Mo;Kim, Sangdong;Kim, Bong-seok;Jin, Youngseok
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.6
    • /
    • pp.1-10
    • /
    • 2019
  • This paper proposes a method to improve the detectable distance by reducing noise to perform a signal processing technique on the received signals. To increase the radar detection range, the noise component of the received signal has to be reduced. The proposed method reduces the noise component by employing two methods. First, the radar signals received with multiple pulses are accumulated. As the number of additions increases, the noise component gradually decreases due to noise randomness. On the other hand, the signal term gradually increases and thus signal to noise ratio increases. Secondly, after converting the accumulated signal into the frequency spectrum, a Least Mean Square (LMS) filter is applied. In the case of the radar received signal, desired signal exists in a specific part and most of the rest is a noise. Therefore, if the LMS filter is applied in the time domain, the noise increases. To prevent this, the LMS filter is applied after converting the received signal into the entire frequency spectrum. The LMS filter output is then transformed into the time domain and then range estimation algorithm is performed. Simulation results show that the proposed scheme reduces the noise component by about 25 dB. The experiment was conducted by comparing the proposed results with the conventional results of the radars held by the Korea Aerospace Research Institute for the international space station.

Android App Birthmarking Technique Resilient to Code Obfuscation (난독화에 강인한 안드로이드 앱 버스마킹 기법)

  • Kim, Dongjin;Cho, Seong-Je;Chung, Youngki;Woo, Jinwoon;Ko, Jeonguk;Yang, Soo-Mi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.4
    • /
    • pp.700-708
    • /
    • 2015
  • A software birthmark is the set of characteristics of a program which can be used to identify the program. Many researchers have studied on detecting theft of java programs using some birthmarks. In case of Android apps, code obfuscation techniques are used to protect the apps against reverse-engineering and tampering. However, attackers can also use the obfuscation techniques in order to conceal a stolen program. A birthmark (feature) of an app can be alterable by code obfuscations. Therefore, it is necessary to detect Android app theft based on the birthmark which is resilient to code obfuscation. In this paper, we propose an effective Android app birthmark and app theft detection through the proposed birthmark. By analyzing some obfuscation tools, we have first selected parameter and the return types of methods as an adequate birthmark. Then, we have measured similarity of target apps using the birthmarks extracted from the apps, where some target apps are not obfuscated and the others obfuscated. The measurement results show that our proposed birthmark is effective for detecting Android app theft even though the apps are obfuscated.

Molecular Genetic Analysis of Microdeletions in Y Chromosome from Korean Male Infertility Patients (한국인 남성 불임환자에서 Y염색체내 미세결실의 분자유전학적 분석)

  • Yoon, Hyun-Soo;Lee, Jeong-Hen;Seo, Ju-Tae;Kim, Hae-Jung;Lee, Dong-Ryul;Jeon, Jong-Sik;Cho, Jung-Hyun;Kim, Moon-Kyoo;Lee, Moo-Sang;Roh, Sung-Il
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.23 no.3
    • /
    • pp.367-377
    • /
    • 1996
  • Genes on the long arm of Y chromosome, particularly interval 6, are believed to playa critical role in human spermatogenesis. The objective of this study was to validate a sequenced-tagged site(STS)-mapping strategy for the detection of Yq microdeletion and to use this method to determine the proportion of men with Yq microdeletions in idiopathic, obstructive, nonobstructive azoospermia, severe OATS and in normal males. We analyzed three STS markers mapped to interval 6 within long arm of the Y chromosome from 106 nonobstructive, 30 obstructive azoospermia, 15 severe OATS patients, and normal 42 males in Korean men. By PCR, we tested leukocyte DNA, for the presences of STS markers(DAZ, sY129 and sY134) and SRY gene as internal control. And PCR results were confirmed by Southern hybridization, and were investigated by SSCP analysis for DAZ gene mutation. None of 42 normal males and 30 obstructive azoospermia had microdeletions, Of the 15 severe OATS typed with DAZ, sY129 and sY134, 3(20.0%) patients failed to amplify 1 or more STS markers, and of the 106 nonobstructive azoospermia typed with DAZ, sY129 and sY134, 12(11.3%) patients failed to amplify 1 or more STS markers. From these results, high prevalence(12.4%) of Yq deletion(DAZ, sY129, sY134) in men with nonobstructive idopathic azoospermia and severe OATS were observed in Korean infertility patients. To avoid the infertile offspring by assisted reproductive technique using ICSI or ROSI, genetic diagnosis will be needed in IVF-ET program.

  • PDF

Comparative Evaluation of Cardiac Output using Echocardiography in Beagle Dogs (비글견에서 심초음파를 이용한 심박출량 측정에 관한 비교 연구)

  • Park, Kitae;Yeon, Seongchan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.384-390
    • /
    • 2012
  • Echocardiographic measurements of cardiac output, including the modified Simpson's method, Automated Contour Tracking(ACT) method, and left ventricular outflow method are well described methods of evaluating cardiac function due to its reliability and the benefits of its non-invasive technique in human medicine. The purpose of this study was to evaluate the accuracy of an echocardiography estimate of cardiac output in isoflurane-anesthetized beagle dogs and was to compare the ACT method to the other methods used in measurement of cardiac output. In healthy beagle dogs, cardiac output results by echocardiography estimate methods showed an excellent correlations with those by the thermodilution method (The modified Simpson's method : r = 0.815, $r^2=0.665$, y = 0.434x + 0.311 ; ACT method : r = 0.86, $r^2=0.748$, y = 0.391x + 0.242 ; ventricular outflow method : r = 0.691, $r^2=0.478$, y = 0.593x + 0.242). Among the results obtained, the ACT method showed the highest correlation coefficient. In conclusion, our study demonstrated that echocardiography estimate methods did not prove to be suitable in accurately measuring absolute cardiac output values but showed an excellent correlation with thermodilution method. Therefore, by using the measurement of cardiac output as supplemental data, echocardiography estimate methods can be used for detection and correction of hemodynamic disturbances during emergency and anesthesia in veterinary practice.

Amplified fragment length polymorphism fingerprinting analysis of Staphylococcus aureus isolated from bovine mastitis milk (소 유방염 유래 Staphylococcus aureus의 AFLP 지문분석)

  • Kim, Yeon-soo;Kim, Sang-kyun;Hwang, Eui-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.157-165
    • /
    • 2001
  • Amplified fragment length polymorphism(AFLP) technique is based on the polymorphism detection through selective PCR amplification of restriction fragments from digested genomic DNA and thus includes the procedures of the total DNA digestion by endonucleases, ligation of adapters to the ends of the fragments, and following the selective amplification of the restricted DNA fragments. This study were aimed to : (1) determine the genetic variability of S aureus strains, (2) estimate genetic diversity within and among these strains, (3) compare phylogenetic relationships among these strains as genetic markers using AFLP techniques. Genomic DNA was digested with a particular combination of three restriction enzymes with specific recognition sites and the DNA fragments were ligated to restriction specific adapters and amplified using the selective primer combinations. In the S aureus strain, the number of scorable AFLP bands detected per each primer combination varied from 29 to 102, with an average of 61.59 using 27 primer combinations. A total of 1,663 markers were generated, 904 bands of which were polymorphic, showing a 33.48% level of polymorphism with these primer combinations. Among the primer combinations, E02/T02, E02/T03, E04/H02, E02/T01 and E04/H03 primer combinations showed a high level of polymorphism with 0.78, 0.76, 0.74, 0.71 and 0.70, respectively. But T03/H01, E01/T02 and E01/T03 primer combinations showed a low level of polymorphism with 0.38, 0.37 and 0.15, respectively, Therefore, the former primer combinations will be the most effective for AFLP analysis of S aureus. In SA1 sub-types the level of polymorphism of S aureus KCTC 1927 was similar to that of S aureus CU 01(0.825) and higher than those of other strains such as S aureus CU 02 (0.715), S aureus KCTC 2199(0.625), S aureus KCTC 1916(0.607) and S aureus KCTC 1621 (0.553). In SA2 sub-types the level of polymorphism of S aureus CU 07 was similar to that of S aureus CU 08(0.935) and higher than those of both S aureus CU 04(0.883) and S aureus CU 05(0.883) and lower than those of S aureus CU 03(0.583). In SA3 subtypes the level of polymorphism of S aureus CU 11 was similar to that of S aureus CU 12(0.913) and lower than that of S aureus CU 15(0.623). The results proved that AFLP marker analysis of S aureus strain could be used to study the epidemiology of mastitis and in addition, common genotype in geographic region could be useful for the development of an effective vaccine or DNA marker for easy diagnosis of mastitis caused by S aureus infection.

  • PDF

Real-Time Monitoring of Mitochondrial ATP Synthesis and Hydrolysis by Surface Infrared Spectroscopy

  • Yamaguchi, Ryo-Taro;Hirano-Iwata, Ayumi;Aonuma, Yuki;Yoshimura, Yuya;Shinohara, Yasuo;Kimura, Yasuo;Niwano, Michio
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.108-109
    • /
    • 2013
  • Mitochondria play key roles in the production of cell's energy. Their dominant function is the synthesis of adenosine 5'-triphosphate (ATP) from adenosine diphosphate (ADP) and phosphate (Pi) through the oxidative phosphorylation. Evaluation of drug-induced mitochondrial toxicity has become increasingly important since mitochondrial dysfunction has recently been implicated in numerous diseases including cancer and diabetes mellitus. Mitochondrial functions have been monitored via oxygen consumption, mitochondrial membrane potential, and more importantly via ATP synthesis since ATP synthesis is the most essential function of mitochondria. Various analytical methods have been employed to investigate ATP synthesis in mitochondria, including high performance liquid chromatography (HPLC), bioluminescence technique, and pH measurement. However, most of these methods are based on destructive analysis or indirect monitoring through the enzymatic reaction. Infrared absorption spectroscopy (IRAS) is one of the useful techniques for real-time, label-free, and direct monitoring of biological reactions [1,2]. However, the strong water absorption requires very short path length in the order of several micrometers. Transmission measurements with thin path length are not suitable for mitochondrial assays because solution handlings necessary for evaluating mitochondrial toxicity, such as rapid mixing of drugs and oxygen supply, are difficult in such a narrow space. On the other hand, IRAS in the multiple internal reflection (MIR) geometry provides an ideal optical configuration to combine solution handling and aqueous-phase measurement. We have recently reportedon a real-time monitoring of drug-induced necrotic and apoptotic cell death using MIR-IRAS [3,4]. Clear discrimination between viable and damaged cells has been demonstrated, showing a promise as a label-free and real-time detection for cell-based assays. In the present study, we have applied our MIR-IRAS system to mitochondria-based assays by monitoring ATP synthesis in isolated mitochondria from rat livers. Mitochondrial ATP synthesis and hydrolysis were in situ monitored with MIR-IRAS, while dissolved oxygen level and solution pH were simultaneously monitored with O2 and pH electrodes, respectively. It is demonstrated that ATP synthesis and hydrolysis can be monitored by the IR spectral changes in phosphate groups in adenine nucleotides and MIR-IRAS is useful for evaluating time-dependent drug effects of mitochondrial toxicants.

  • PDF

Development and comparison of convenient residue analysis for avermectin B1 in apple and soil (사과 및 토양중 avermectin B1의 간편한 잔류 분석법 개발과 비교)

  • Lee, Kang-Bong;Kim, Yong-Du;Shim, Jae-Han;Suh, Yong-Tack
    • Applied Biological Chemistry
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 1992
  • Avermectin B1(abamectin) is an very effective acaricide/insecticide. Because it is applied at low rates, the resultant residue level would be quite low and this requires highly sensitive analytical method. In this study, three analytical methods for avermectin $B1_a$, were compared in view of detectability and sensitivity. The first analytical method was an HPLC method employing the fluorescence detection of avermectin. The second analytical technique to quantitate avermectin $B1_a$, and its photodegradative delta 8,9-isomer employed trifluoroacetic anhydride and 1-methylimidazole in DMF. The new method was the modification of trifluorescence method. The average recoveries of avermectin $B1_a$ for the concentration range from 1 and 10 ng/g in whole apple fruit by fluorescence method were 90.3% and 88.2% respectively. In trifluorescence method, the recoveries of the avermectin $B1_a$ and delta 8,9-isomer were 100.7% and 94.7% in concentration from 5 ng/g and 25 ng/g. The average recoveries of 5 ng and 25 ng/g in the newly modified method were 95.0, 99.0. 96.0, 92.8% in whole apple and soil respectively.

  • PDF

Feature-based Non-rigid Registration between Pre- and Post-Contrast Lung CT Images (조영 전후의 폐 CT 영상 정합을 위한 특징 기반의 비강체 정합 기법)

  • Lee, Hyun-Joon;Hong, Young-Taek;Shim, Hack-Joon;Kwon, Dong-Jin;Yun, Il-Dong;Lee, Sang-Uk;Kim, Nam-Kug;Seo, Joon-Beom
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.237-244
    • /
    • 2011
  • In this paper, a feature-based registration technique is proposed for pre-contrast and post-contrast lung CT images. It utilizes three dimensional(3-D) features with their descriptors and estimates feature correspondences by nearest neighborhood matching in the feature space. We design a transformation model between the input image pairs using a free form deformation(FFD) which is based on B-splines. Registration is achieved by minimizing an energy function incorporating the smoothness of FFD and the correspondence information through a non-linear gradient conjugate method. To deal with outliers in feature matching, our energy model integrates a robust estimator which discards outliers effectively by iteratively reducing a radius of confidence in the minimization process. Performance evaluation was carried out in terms of accuracy and efficiency using seven pairs of lung CT images of clinical practice. For a quantitative assessment, a radiologist specialized in thorax manually placed landmarks on each CT image pair. In comparative evaluation to a conventional feature-based registration method, our algorithm showed improved performances in both accuracy and efficiency.

An Adequate Band Selection for Vegetation Index of CASI-1500 Airborne Hyperspectral Imagery Using Image Differencing and Spectral Derivative (차연산과 분광미분을 이용한 항공 초분광영상의 식생지수 산출 적절밴드 선택)

  • Kim, Tae-Woo;We, Gwang-Jae;Suh, Yong-Cheol
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.4
    • /
    • pp.16-28
    • /
    • 2013
  • Recently the various applications and spectral indices development of airborne hyperspectral imagery(A-HSI) has been increased. Especially the vegetation indices (VIs) were used to verify stress and vigor of vegetation. The VIs needs two or more spectral bands selectively to calculate as NIR(near infrared) and red wavelength. The A-HIS has specific band characteristics as narrow, continues and many. The A-HIS has narrow, continues and many specific band characteristics. That could be make it confuse which of bands could be explained for appropriate vegetation characteristics. If the A-HIS bands is not the same the wavelength with VIs' development band setting, then it need a selection adequate for spectral characteristics of target vegetation. Therefore we set 4 substitute bands for NIR and red wavelength respectively and calculated two VIs combined with substitute bands such as NDVI(normalized difference vegetation index) and MSRI(modified simple ratio index). To consider the variation of each VIs, we adapted the image differencing method of change detection technique. Also, we used spectral derivative to identify appropriate bands for spectral characteristics of digital forest cover type map. The result of adequate bands for two VIs selected red #3 as 680.2nm and NIR #2 as 801.7nm. This wavelength was good for any forest type in low variations.

Analysis Method for Full-length LiDAR Waveforms (라이다 파장 분석 방법론에 대한 연구)

  • Jung, Myung-Hee;Yun, Eui-Jung;Kim, Cheon-Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.4 s.316
    • /
    • pp.28-35
    • /
    • 2007
  • Airbone laser altimeters have been utilized for 3D topographic mapping of the earth, moon, and planets with high resolution and accuracy, which is a rapidly growing remote sensing technique that measures the round-trip time emitted laser pulse to determine the topography. The traveling time from the laser scanner to the Earth's surface and back is directly related to the distance of the sensor to the ground. When there are several objects within the travel path of the laser pulse, the reflected laser pluses are distorted by surface variation within the footprint, generating multiple echoes because each target transforms the emitted pulse. The shapes of the received waveforms also contain important information about surface roughness, slope and reflectivity. Waveform processing algorithms parameterize and model the return signal resulting from the interaction of the transmitted laser pulse with the surface. Each of the multiple targets within the footprint can be identified. Assuming each response is gaussian, returns are modeled as a mixture gaussian distribution. Then, the parameters of the model are estimated by LMS Method or EM algorithm However, each response actually shows the skewness in the right side with the slowly decaying tail. For the application to require more accurate analysis, the tail information is to be quantified by an approach to decompose the tail. One method to handle with this problem is proposed in this study.