• Title/Summary/Keyword: Detection sensitivity

Search Result 2,447, Processing Time 0.033 seconds

Planar Vibratory Gyroscope using Electrostatic Actuation and Electromagnetic Detection (정전력 구동 및 전자력 검출형 평면 진송 각속도계)

  • 이상훈;임형택;이승기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1089-1092
    • /
    • 1995
  • A planar vibratory gyroscope using electrostatic actuation and electromagnetic detection is proposed. The gyroscope has large sensitivity and can be fabricated by using surface micrimachining, bulk micromachining and conventional machining technology. In this paper, the gyroscope and the electromagnetic detecting system equations are derived to determine the output characteristics for the planar vibratory gyroscope using electrostatic acturation and electromagnetic detection. The maximum output is obtained when the driving frequencyequals to the detecting frequency. The resonant frequencies of the resonator are determined by the beam stiffness, i.e. the material constants and spring dimensions. The dimensions of the beams are determined using the analytic vibration modelling. The expected resonant frequencies are 200Hz both and the sensitivity is 62mV/deg/sec with 4000 electronic circuit amplifying coefficient for an AC drive voltage of 3V bias voltage of 15V and DC field current of 50 mA.

  • PDF

RF Plasma Processes Monitoring for Fluorocarbon Polluted Plasma Chamber Cleaning by Optical Emission Spectroscopy and Multivariate Analysis (Optical Emission Spectra 신호와 다변량분석기법을 통한 Fluorocarbon에 의해 오염된 반응기의 RF 플라즈마 세정공정 진단)

  • Jang, Hae-Gyu;Lee, Hak-Seung;Chae, Hui-Yeop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.242-243
    • /
    • 2015
  • Fault detection using optical emission spectra with modified K-means cluster analysis and principal component anal ysis are demonstrated for inductive coupl ed pl asma cl eaning processes. The optical emission spectra from optical emission spectroscopy (OES) are used for measurement. Furthermore, Principal component analysis and K-means cluster analysis algorithm is modified and applied to real-time detection and sensitivity enhancement for fluorocarbon cleaning processes. The proposed techniques show clear improvement of sensitivity and significant noise reduction when they are compared with single wavelength signals measured by OES. These techniques are expected to be applied to various plasma monitoring applications including fault detections as well as chamber cleaning endpoint detection.

  • PDF

Construction of Through Transmission Scanning System for Weld Defects Detection of Rail Weld Zone (레일용접부의 용접결함검출을 위한 투과주사시스템의 구축)

  • Yun, In-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.30-35
    • /
    • 2005
  • This study proposes construction of through transmission for weld defects detection of rail weld zone from ultrasonic signals. For these purposes, the ultrasonic signals for defects(porosity and crack) of weld zone in rails are acquired in the type of time series data and echo strength. 6 lines in the distance amplitude characteristics curve(DACC) indicated damage evaluation standard of weld zone in rails. The acquired ultrasonic signals agree flirty well with the mesured results of reference block and sensitivity block(defect location beam propagation distance, echo strength, etc). The proposed construction of through transmission in this study can be used for weld defects detection of rail weld zone.

The Assessment of Ultrasensitive HBsAg kit's Sensitivity level and Performance in Detection of Mutant Forms (Ultra-sensitive HBsAg IRMA 키트의 민감도 및 변이형 검출능 평가)

  • Ha, Dong-Hyuk;Min, Kyung-Sun;Noh, Gyeong-Woon;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.121-125
    • /
    • 2011
  • Purpose: The DNA-type virus HBV, discovered by D. Dane and others in 1976, is approximately 42nm big and known as the main cause of liver-related diseases around the world. HBsAg has 4 kinds of subtypes including adw, adr, ayw and ayr and besides common antigen factor a, there are d, y, r, w. From the methods of serologically testing HBV, IRMA, EIA and CLIa were developed for testing HBsAg and are being used in examining the surface antigen of HBV. In this study, among the methods for testing HBV, the recently developed RIAKEY Ultrasensitive HBsAg IRMA kit's sensitivity level and performance in detection of mutant forms were measured and compared with CLIA. Materials and methods: Two certified reference materials, which are WHO 1st International Standard 1985(80/549) and WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA), were used in the examination and the sensitivity level was measured by diluting these materials from 0.08 IU/ml to 0.005 IU/ml. The materials for examining the detection of mutant forms included 9 kinds of subtype 'ad' and one kind of subtype 'ay' purchased from DSI company. Also, with the use of positive and negative samples, they was compared with CLIA. Result: Ultrasensitive HBsAg kit based on IRMA method showed the detection of up to 0.01 IU/ml not only for WHO 1st International Standard 1985(80/549) but also for WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA) and the sensitivity level was measured as 0.01 IU/ml by WHO standard. In testing the performance for detection of mutant forms, the 9 kinds of subtype 'ad' and one kind of subtype 'ay' mutant materials were detected, demonstrating the capacity of detecting various types of mutant forms. Conclusions: With the clinical importance of sensitivity level and performance in detection of mutant forms increasing in the field of HBsAg diagnosis, the examination of IRMA's effectiveness using RIA method in the aspects of the sensitivity level and performance in detection of mutant forms was carried out and its result is as follows. The sensitivity level was measured as 0.01 IU/ml by WHO standard and it was possible to measure various types of mutant forms with high sensitivity. Thus it is suggested that more speedy and accurate reports could be produced from a nuclear medicine laboratory for clinical practitioners requiring results of various situations.

  • PDF

Comparison of 99mTc-DMSA Renal Scan and Power Doppler Ultrasonography for the Detection of Acute Pyelonephritis and Vesicoureteral Reflux

  • Bae, Hee Jung;Park, Yong-Hoon;Cho, Jae Ho;Jang, Kyung Mi
    • Childhood Kidney Diseases
    • /
    • v.22 no.2
    • /
    • pp.47-51
    • /
    • 2018
  • Purpose: Urinary tract infection (UTI) is one of the common infectious diseases in children. Several imaging modalities can be used to confirm the presence of acute pyelonephritis (APN). Among them the 99mTcdimercaptosuccinic acid renal scan (DMSA scan) is used as a gold standard for diagnosis. Ultrasonography technology is evolving. Therefore, in this study, we investigated the sensitivity and specificity of Power Doppler ultrasonography (PDU) compared to the results from the previous study. Methods: There were 260 patients included in this study, aged between 1 and 12 months old. The patients were admitted to the Yeungnam University Medical Center between January 2008 and December 2015. All patients underwent both DMSA scan and PDU within 5days of admission. Voiding cystourethrography (VCUG) was performed in 195 patients with abnormal DMSA scan or PDU. Results: The diagnostic sensitivity of APN using PDU was 45.5% and specificity was 85.5% in 260 patients following detection of a defect on DMSA scan that was defined as APN. The diagnostic sensitivity and specificity of PDU for VUR were 65.5 % and 60.1%, respectively. The diagnostic sensitivity and specificity of DMSA scan for VUR were 95.7% and 14.1%, respectively. Conclusion: PDU has a high specificity but low sensitivity, so there are limitations in using it to replace a DMSA scan for the diagnosis of APN in children. DMSA scan and PDU have different sensitivity and specificity in diagnosis of VUR, respectively. Therefore, we suggest that the sensitivity and specificity of each test can be helpful in diagnosing APN and VUR when used in conjunction.

Experimental Study on Signal Sensing of a High Sensitive Fiber Optic Hydrophone (실험을 통한 소형 고감도 광섬유 하이드로폰의 감지성능 연구)

  • 김정석;윤형규;설재수
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1152-1156
    • /
    • 1999
  • In this study, a fiber optic air-backed mandrel hydrophone has been constructed and performance of acoustic signal detection has been measured. The hydrophone is based on a Mach-Zehnder interferometer with 35 m of sensing fiber. The sensitivity is measured up to -128 dB re rad/$\mu$ Pa in range from 1.4 kHz to5 kHz. A system with this design of hydrophone may be applied to detect low frequency underwater acoustic signals.

  • PDF

H_ Fault Detection Observer Design for Large Scale Time-Invariant Systems (대규모 선형시불변 시스템을 위한 H_ 고장검출 관측기 설계)

  • Lee, Ho-Jae;Kim, Do-Wan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.8
    • /
    • pp.818-822
    • /
    • 2009
  • In this paper, we consider a decentralized observer design problem for fault detection in large-scaled linear time-invariant systems. Since the fault detection residual is desired to be sensitive on the fault, we use the H_ index performance criterion. Sufficient conditions for the existence of such an observer is presented in terms of linear matrix inequalities. Simulation results show the effectiveness of the proposed method.

Comparison of Detectable Levels for Screening Residual Antibacterial Agents by Bioassay (잔류 항균물질에 대한 미생물학적 간이검사법의 검출감도 비교)

  • JUNG Sung Hee;KIM Jin Woo;SOHN Sang-Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.3
    • /
    • pp.256-260
    • /
    • 1999
  • Minimun-detectable levels to 28 antibacterial agents used for the prevention and the treatment of fish diseases were determined to establish optimal detective method of bioassay in fish by the EEC 4-plate method, the modified method of EEC 4-plate and the standard method of analysis in food safety regulation. The test organisms used in the methods of bioassay were as follows: Bacillus subtilis BGA (B. subtilis) and Micrococcus luteus ATCC 9341 (M. luteus) in the EEC 4-plate method, B. subtilis, M. luteus and Bacillus cereus var. mycoides ATCC 11778 (B. cereus) in the modified of EEC 4-plate, and B. subtilis, M. luteus, B. cereus and Bacillus stearothermophilis var. calidolactis C-953 (B. stearothermophilis) in the standard method. The standard method showed predominant sensitivity in the detection of penicillins (PCs), and was also highly sensitive to aminoglycosides (AGs). The sensitivity of standard method in the detection of tetracyclines (TCs), marrolides (MLs), nitrofuran derivatives(NFs) and quinolones (QNs) was very low, and against sulfonamides (SAs), however, was extremely low. The modified method of EEC 4-plate showed very high sensitivity to TCs. Both the EEC 4-plate and the modified method of EEC 4-plate showed competitively high sensitivity in the detection of PCs, MLs, NFs, QNs and SAs. All the methods studied in the experiment showed very low sensitivity against chloramphenicol (CMs). Consequently, the modified method of EEC 4-Plate was the best bioassay method with a wide range of sensitivity for the optimal detection of the residual antibacterial agents in fish.

  • PDF

Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Ghandari, Farnaz;Hadinezhad, Arash
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel(PPA) and oblique projected periapical(OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects(10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects(P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.

Structural Damage Detection Method Using Sensitivity Matrices (민감도행렬을 사용한 구조물의 손상추정법)

  • 윤정방;김두기
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.117-126
    • /
    • 1996
  • Damage detection methods using structural tests can be divided into two methods, i.e., static and dynamic. The static methods which use the stiffness properties of the structure are simpler than the dynamic methods. However, static approaches are very sensitive to the displacement measurement noises and modeling errors. The dynamic methods also have limitations in acquiring the natural frequencies and mode shapes of the high frequencies. In this study, a method for the structural damage assessment using sensitivity matrices is developed, in which the drawbacks of the static and dynamic methods can be compensated. Based on the measurement data for the static displacements and dynamic modal properties, the damage locations and the degree of damage are determined using the presented sensitivity matrix method. The efficiency of the proposed method has been examined through numerical simulation studies on truss type structures.

  • PDF