• Title/Summary/Keyword: Detection sensitivity

Search Result 2,447, Processing Time 0.044 seconds

Detection of antibodies and antigens of Aujeszky's disease virus using dot-immunoassay (Dot-immunoassay를 이용한 Aujeszky's disease virus항원 및 항체 검출)

  • Jun, Moo-hyung;Cho, Young-sung;Chang, Kyung-soo
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.3
    • /
    • pp.529-536
    • /
    • 1994
  • To establish more specific and simple diagnostic methods for detection of the antibodies and antigens of Aujeszky's disease virus(ADV), we designed indirect dot-immunoassay(IDI) and double sandwich dotimmunoassay(DSDI) using the solid phases of nitrocellolose paper and polystyrene plate. The diagnostic efficacy of these methods was investigated. As the sensitivity of IDI was tested by various virus concentration, the specimens with the virus titer above $10^{4.0}TCID_{50}/0.2ml$ showed positive reaction, but that below $10^{1.0}TCID_{50}/ml$ revealed negative. Tonsil emulsion at the virus titer of $10^{4.5}TCID_{50}/0.2ml$ showed the highest sensitivity as diluted by 1/100. In detection of ADV antigens from the various tissues of the rats and pigs infected with ADV, IDI using monoclonal antibody showed the higher specificity as compared with IDI using polyclonal antibody and virus isolation method. The efficacy of the DSDI for detection of ADV antibody was compared with other tests. The sensitivity of DSDI was higher than virus neutralization(VN) and agar gel immunodiffusion test(AGID). Meanwhile, specificity of DSDI was lower than AGID, but similar to IDEA. In comparison with VN test, DSDI showed 96.9% agreement to VN test that is the highest of three tests. In general, application of polyclonal antibody in both tests caused the higher sensitivity but the lower specificty.

  • PDF

Clinical Evaluation of Tumor Markers for Diagnosis in Patients with Non-small Cell Lung Cancer in China

  • Ma, Li;Xie, Xiao-Wei;Wang, Hai-Yan;Ma, Ling-Yun;Wen, Zhong-Guang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4891-4894
    • /
    • 2015
  • Background: To evaluate the value of combined detection of serum carcinoembryonic antigen (CEA), cytokeratin 19 fragment (CYFRA21-1), and carbohydrateantigen 125 (CA125) for the clinical diagnosis of nonsmall cell lung cancer (NSCLC). Materials and Methods: Serum CEA, CYFRA21-1 and CA125 were assessed in 140 patients with NSCLC, 90 patients with benign lung disease and 90 normal control subjects, and differences of expression were compared in each group, and joint effects of these tumor markers in the diagnosis of NSCLC were analyzed. Results: Serum CEA, CYFRA21-1 and CA125 in patients with NSCLC were significantly higher than those with benign lung disease and normal controls (P<0.05). The sensitivity of CEA, CYFRA21-1 and CA125 were 49.45%, 59.67%, and 44.87% respectively. As expected, combinations of these tumor markers improved their sensitivity for NSCLC. The combined detection of CEA + CYFRA21-1 was the most cost-effective combination which had higher sensitivity and specificity in NSCLC. Elevation of serum CEA and CYFRA21-1 was significantly associated with pathological types (P<0.05) and elevation of serum CEA, CYFRA21-1 and CA125 was significantly associated with TNM staging (P<0.05). Conclusions: Single measurement of CEA, CYFRA21-1 and CA125 is of diagnostic value in the diagnosis of lung cancer, and a joint detection of these three tumor markers, could greatly improve the sensitivity of diagnosis on NSCLC. Combined detection of CEA + CYFRA21-1 proved to be the most economic and practical strategy in diagnosis of NSCLC, which can be used to screen the high-risk group.

Comparative Sensitivity of PCR Primer Sets for Detection of Cryptosporidium parvum

  • Yu, Jae-Ran;Lee, Soo-Ung;Park, Woo-Yoon
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.3
    • /
    • pp.293-297
    • /
    • 2009
  • Improved methods for detection of Cryptosporidium oocysts in environmental and clinical samples are urgently needed to improve detection of cryptosporidiosis. We compared the sensitivity of 7 PCR primer sets for detection of Cryptosporidium parvum. Each target gene was amplified by PCR or nested PCR with serially diluted DNA extracted from purified C. parvum oocysts. The target genes included Cryptosporidium oocyst wall protein (COWP), small subunit ribosomal RNA (SSU rRNA), and random amplified polymorphic DNA. The detection limit of the PCR method ranged from $10^3$ to $10^4$ oocysts, and the nested PCR method was able to detect $10^0$ to $10^2$ oocysts. A second-round amplification of target genes showed that the nested primer set specific for the COWP gene proved to be the most sensitive one compared to the other primer sets tested in this study and would therefore be useful for the detection of C. parvum.

Use of laser fluorescence device 'DIAGNODent$^{(R)}$' for detecting caries (레이저 우식진단기기 'DIAGNODent$^{(R)}$'의 활용)

  • Lee, Byoung-Jin
    • The Journal of the Korean dental association
    • /
    • v.49 no.8
    • /
    • pp.461-471
    • /
    • 2011
  • The detection of carious lesions is a key point to apply appropriate preventive measures or operative treatment of dental caries. A laser fluorescence device DIAGNOdent$^{(R)}$ (KaVo, Biberach, Germany) has also been shown to be of additional clinical value in the detection of initial caries. This report focus on the DIAGNOdent$^{(R)}$ for caries detection. DIAGNOdent$^{(R)}$ irradiate visible red light at a wavelength of 655 nm to elicit near-infrared fluorescence from caries lesion. This device is known as a reproducible method for caries detection, with good sensitivity and specificity especially for caries detection on occlusal and accessible smooth surfaces. DIAGNOdent$^{(R)}$ tended to be more sensitive method of detecting occlusal dentinal caries, however, showed more false-positive diagnoses than the visual inspection. So Clinician should not use the device as a clinician's primary diagnostic method and it is recommended that the device should be used in the decision-making process in relation to the diagnosis of caries as a second opinion in cases of doubt after visual inspection. The trend of modern dentistry would be a preventive approach rather than invasive treatment of the disease. This is possible only with early detection and respective preventive measures, DIAGNOdent$^{(R)}$ can help the changes.

Damage detection of mono-coupled multistory buildings: Numerical and experimental investigations

  • Xu, Y.L.;Zhu, Hongping;Chen, J.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.709-729
    • /
    • 2004
  • This paper presents numerical and experimental investigations on damage detection of mono-coupled multistory buildings using natural frequency as only diagnostic parameter. Frequency equation of a mono-coupled multistory building is first derived using the transfer matrix method. Closed-form sensitivity equation is established to relate the relative change in the stiffness of each story to the relative changes in the natural frequencies of the building. Damage detection is then performed using the sensitivity equation with its special features and minimizing the norm of an objective function with an inequality constraint. Numerical and experimental investigations are finally conducted on a mono-coupled 3-story building model as an application of the proposed algorithm, in which the influence of modeling error on the degree of accuracy of damage detection is discussed. A mono-coupled 10-story building is further used to examine the capability of the proposed algorithm against measurement noise and incomplete measured natural frequencies. The results obtained demonstrate that changes in story stiffness can be satisfactorily detected, located, and quantified if all sensitive natural frequencies to damaged stories are available. The proposed damage detection algorithm is not sensitive to measurement noise and modeling error.

A Pacemaker AutoSense Algorithm with Dual Thresholds

  • Kim, Jung-Kuk;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.477-484
    • /
    • 2002
  • A pacemaker autosense algorithm with dual thresholds. one for noise or tachyarrhythmia detection (noise threshold, NT) and the other for intrinsic beat detection (sensing threshold. ST), was developed to improve the sensing performance in single pass VDD electrograms. unipolar electrograms, or atrial fibrillation detection. When a deflection in an electrogram exceeds the NT (defined as 50% of 57), the autosense algorithm with dual thresholds checks if the deflection also exceeds the ST. If it does, the autosense algorithm calculates the signal to noise ratio (SNR) of the deflection to the highest deflection detected by NT but lower than ST during the last cardiac cycle. If the SNR 2, the autosense algorithm declares an intrinsic beat detection and calculates the next ST based on the three most recent intrinsic peaks. If the SNR $\geq$2, the autosense algorithm checks the number of deflections detected by NT during the last cardiac cycle in order to determine if it is a noise detection or tachyarrhythmia detection. Usually the autosense algorithm tries to set the 57 at 37.5% of the average of the three intrinsic beats, although it changes the percentage according to event classifications. The autosense algorithm was tested through computer simulation of atrial electrograms from 5 patients obtained during EP study, to simulate a worst sensing situation. The result showed that the ST levels for autosense algorithm tracked the electrogram amplitudes properly, providing more noise immunity whenever necessary. Also, the autosense algorithm with dual thresholds achieved sensing performance as good as the conventional fixed sensitivity method that was optimized retrospectively.

Development of cellulose nano beads based a rapid detection kit to detect staphylococcal enterotoxin B

  • Kim, Giyoung;Yoo, Jinyoung;Park, Saetbyeol
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.3
    • /
    • pp.549-557
    • /
    • 2019
  • Staphylococcal enterotoxin is a very common cause of food poisoning. Conventional detection methods for the toxin including enzyme-linked immunosorbent assays (ELISAs), chemiluminescence (ECL), and polymerase chain reaction (PCR) assays require a lot of time, efforts, and expert technicians. Lateral flow strip kits have shown great potential for the rapid detection of foodborne pathogens. The lateral flow strip kit is widely used in clinical settings because it is easy to use, fast, and cost effective. A typical lateral flow strip kit uses colloidal gold to generate a visual signal. However, the lateral flow strip kit based on colloidal gold has limited sensitivity to fulfill food safety regulation requirements. This study was performed to develop a rapid test kit for pathogenic staphylococcal enterotoxin B (SEB) in food samples. The rapid detection kit was fabricated based on a nitrocellulose lateral-flow strip. Cellulose nano beads and SEB antibodies were used as the tag and receptor, respectively, to improve the detection performance. Manually spotted SEB antibody and anti-rabbit antibody on the surface of the nitrocellulose membrane were used as test and control spots, respectively. The feasibility of the rapid test kit to detect SEB in samples was evaluated. The sensitivity of the kit was 10 ng/mL SEB spiked in PBS. Additionally, the rapid test kit could detect 1 ng/mL of SEB in chicken meat extract.

Effects of Lifestyles, Dietary Habits, Food Preferences and Nutrient Intakes on Sensitivity to and Preference for Salty Tastes of Korean Women

  • Lee, Hong-Mie
    • Journal of Community Nutrition
    • /
    • v.8 no.4
    • /
    • pp.185-192
    • /
    • 2006
  • This study was performed to investigate factors affecting sensitivity and preference for salty tastes of Korean adult females. Sensitivity and preference for salty tastes were determined as detection threshold concentration of NaCl solution and the optimally-preferred NaCl concentration of the bean sprout soup, respectively. A self-administered questionnaire was used to obtain the information regarding general characteristics, self diagnosis of stress, health-related lifestyle practices, dietary habits and food preferences. Dietary intake using 24-hours recall and blood pressure were measured. Salty taste detection thresholds and optimally-preferred NaCl concentrations were 0.0197% and 0.357%, respectively. There was a significant positive correlation between the optimally-preferred salt concentration and age, despite no significant correlation between either sensitivity or preference for salty taste and sodium intake, which was 3,605mg/day. Those who had bread or cereal with milk as breakfast instead of a traditional Korean meal and those who preferred jjigae to soup had significantly higher NaCl preferences for bean sprout soup. Going to bed after midnight and skipping meals (${\geq}3/week$) decreased salty taste sensitivity without reaching statistical significance. Self awareness of one's own health, recent weight changes, family history of hypertension, sleep quality, getting-up time, rate of eating and other food preferences did not affect either perception. Stress level, TV watching, BMI and sodium intake did not have significant correlation to sensitivity or preference. Further research including a large number of well-controlled subjects and more accurate measurement of sodium intake should be directed to find other factors affecting salt preference and sensitivity in order to decrease Na intake and related diseases.

Nano-Scale Immobilization of Antibody for the Construction of Immunosensor

  • Cho, Il-Hoon;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.701-705
    • /
    • 2003
  • Performance of an immunosensor can usually be assessed in terms of its analytical sensitivity and specificity. Sensitivity, i.e., the detection limit of analyte, is particularly determined by the amount of analyte molecules bound to the capture antibody immobilized onto a solid surface. In order to increase the binding complexes, we have investigated an immobilization method of antibody allowing for a molecular arrangement of the protein on a selective surface of a nano-patterned solid substrate. This has not been accomplished only by a surface treatment with a chemical, but also by fragmentation of immunoglobulin. Such approach would offer a protocol of antibody immobilization for the construction of nano-immunosensor and eventually improve the sensitivity of detection.

  • PDF

Tool Fracture Detection in Milling Process (II) -Part 2: Tool Fracture Detection in Rough Milling Using Spindle Motor Current- (밀링 공정시 공구 파손 검출 (II) -제 2 편: 주축모터 전류를 이용한 밀링의 황삭 가공 중 공구파손 검출-)

  • 김기대;이강희;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.110-119
    • /
    • 1998
  • Dynamic cutting force variations in milling process were measured indirectly using spindle motor current. Magnitude of the spindle motor current is independent of cutting direction. Quasi-static sensitivity of the spindle motor current is higher than that of the feed motor current. Dynamic sensitivity of the spindle motor current is lower but cutting force was correctly represented by spindle RMS current in rough milling. In rough milling, chipping and tool fracture were well detected by the proposed tool fracture index using spindle motor current.

  • PDF