• Title/Summary/Keyword: Detection of partial discharge signal

Search Result 79, Processing Time 0.027 seconds

PD Measure and UV Detection in according to Withstand Voltage Characteristics of Polymer Insulator (폴리머 애자의 내전압 특성에 따른 부분방전 측정과 자외선 검출)

  • Shong, Kil-Mok;Kim, Young-Seok;Kim, Jong-Seo;Jung, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.76-77
    • /
    • 2008
  • The purposes of this paper ensure for the economical efficiency, accuracy, and good applications in domestic site set up the power installations. For the efficient conduct of these purposes, there are measured the partial discharge(PD) used by current probe and compared with detected signal of UV sensor. As the results, PD generated about 35% of breakdown voltage in polymer insulator. UV signal due to high voltage in polymer insulator is detected from about 1.7mV at 30kV to about 3mV at 70kV. Signal detected by ultra-sonic is increased at about 75% of breakdown voltage abruptly. It appears that error range is increased in boundary. UV sensor is needed must use from the practical and economical points of view.

  • PDF

The development of Ultra-High Frequency(UHF) sensor for Partial Discharge monitoring in Gas Insulated Switchgears (GIS내 부분방전 검출을 위한 광대역 UHF 센서 개발)

  • Kim, Young-Ro;Choi, Jae-Ok;Lee, Young-Sang;Kim, Jae-Chul;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1975-1978
    • /
    • 2004
  • We developed internal and external type sensor to measure ultra-high frequency (UHF) partial discharge (PD) in 170 kV gas-insulated switchgears (GIS). We also manufactured a PD-generator to verify and measure the detection sensitivity of those sensors. We measured the output power of the UHF PD sensors induced by PDs of 5 pC using the PD-generator. We measured UHF propagation loss of an 170 kV GIS for optimal arrangement of the sensors. We used swept UHF signal from a network analyzer into the GIS to measure the loss of various components of the GIS.

  • PDF

A Novel AE Based Algorithm for PD Localization in Power Transformers

  • Mehdizadeh, Sina;Yazdchi, Mohammadreza;Niroomand, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1487-1496
    • /
    • 2013
  • In this paper, a novel algorithm for PD localization in power transformers based on wavelet de-noising technique and energy criterion is proposed. Partial discharge is one of the main failures in power transformers. The localization of which could be very useful for maintenance systems. Acoustic signals due to a PD event are transient, irregular and non-repetitive. So wavelet transform is an efficient tool for this signal processing problem that gives a time-frequency demonstration. First, different wavelet based de-noising methods are analyzed. Then, a reasonable structure for threshold value determining and applying manner on signals is presented. Evaluated errors are good evidences for choices. Next, applying the elimination low energy frequency bands is discussed and developed as a de-noising method. Time differences between signals are used for PD localization. Different ways in time arrival detection are introduced and a novel approach in energy criterion method is presented. At the end, the quality of algorithm is verified through the different assays in lab.

The development of ultra-high frequency ultra-wide bandwidth sensor for Partial Discharge monitoring in Gas Insulated Switchgears (GIS 부분방전 검출용 극초단파 초광대역 센서 개발)

  • Kim, Young-Ro;Choi, Jae-Ok;Lee, Young-Sang;Kang, Chang-Won;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.113-116
    • /
    • 2004
  • We developed internal and external type sensor to measure ultra-high frequency (UHF) partial discharge (PD) in 170 kV gas-insulated switchgears (GIS). We also manufactured a PD-generator to verify and measure the detection sensitivity of those sensors. We measured the output power of the UHF PD sensors induced by PDs of 5 pC using the PD-generator. We measured UHF propagation loss of an 170 kV GIS for optimal arrangement of the sensors. We used swept UHF signal from a network analyzer into the GIS to measure the loss of various components of the GIS.

  • PDF

Detection of Ultrasonic Signals Associated with Tree Growth in Epoxy resin (애폭시수지의 트리성장에 따른 초음파 신호검출)

  • 이상우;송현직;이광식;이동인;김인식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.285-288
    • /
    • 1998
  • Ultrasonic signal characteristics related with the growth of electrical trees in epoxy resin are examined under 67[Hz] ac voltage application along with a CCD camera and PD current method. The ultrasonic sensor with a resonant frequency of 200[Hz] supported by a mechanical spring is attached directly to the lower-side of plane electrode. The magnitude of Partial discharge and count rate of ultrasonic signals have been measured according to the tree growth from a needle tip in an epoxy sample.

  • PDF

A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal (광섬유 내의 유도 브릴루앙 산란광을 이용한 초고압전력케이블 열화진단에 관한 연구)

  • Hwang, Kyoung-Jun;Yeoum, Keoung-Tae;Kim, Yong-Kab;Kim, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1558-1559
    • /
    • 2007
  • This study is an application field by using optical fiber. The system to measure sBs from optical fiber is designed, So it can be used as a temperature sensor. by using frequency shift, resulting from temperature changes. the frequency shift is checked by changing temperature from $25^{\circ}C$ to $69^{\circ}C$ with chamber in the laboratory and using 40Km optical fiber. It's also measured by varying the length of optical fiber The program to do the real-time monitoring and analyze the measured data is created to find accurate frequency. It can be used as an optical fiber sensor, which is capable of measuring temperature and distance by using sBs.

  • PDF

The Detection of Calibration Signal for Test of the Partial Discharge Measurement (부분방전 측정 시험을 위한 기준 신호 검출)

  • Lee, Yong-Sung;Lee, Kyoung-Yong;Choi, Yong-Sung;Lee, Chang-Su;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.316-318
    • /
    • 2004
  • 본 논문은 부분방전검출 시험 전에 수행하는 Calibration 신호 주입 및 검출 방법에 대한 연구이다. 사용된 시료는 활선상의 배전용 XLPE 케이블이다. 실험방법은 50kV 내전압기 (750-2CTS, Hipotronics)로부터 공급된 Calibration 신호를 Lemke (LDP-5, LDIC), 오실로스코프 (TDS-3012, Tektronix)와 주파수 분석기 (8563E, HP)를 사용하여 측정하였다. 마지막으로 시험에 사용된 센서는 안테나 특성의 UHF 센서와 고주파 특성의 HFCT 센서이다. 실험결과, Calibration 신호 주입 시 시험 환경 및 센서에 따라 Calibration 신호와 주입방법의 차이가 발생하였다. 따라서 신호의 형태와 인가 전하량에 따른 Calibration 파형과 전하량 변화를 알 수 있었다.

  • PDF

A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD) (고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구)

  • Kim, J.H.;Koo, J.Y.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

A New Technique for Partial Discharge Signal Detection in Oil using Op (광학적 방법을 이용한 유중 부분방전 신호 검출을 위한 신기술 개발)

  • Choi, S.S.;Kang, W.J.;Chang, Y.M.;Lee, J.H.;Kim, J.T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1705-1707
    • /
    • 1997
  • In this work, a possible new PD de technique, based on the electro-optic effect(P effect), has been proposed. The refractive index ellipsoid of EO crystal, as $LiNbO_3$, is changed by both the externally a electric field and its hysteresis loop of which effect on this hysteresis loop gives rise t discrepancy of index variation. Therefore, an eq regarding the phase variation of modulated beam through $LiNbO_3$ crystal under applied e field, is newly proposed considering the influen hysteresis characteristics. For this purpose generated from needle-plane electrode in oil has detected by use of $LiNbO_3$ cell and analyzed b equation. As a result, it is observed that PD measu phase intervals are limited by the cr characteristics such as asymmertrical P-E hyst and half-wave voltage.

  • PDF