• Title/Summary/Keyword: Detecting channel

Search Result 172, Processing Time 0.025 seconds

Some case histories to detect underwater buried objects by electrical and magnetic methods (수중 매장물 조사에 응용되는 전기 및 자기 탐사사례)

  • JUNG Hyun Key;Park Yeong-Sue;Lim Mutaek;Rim Hyoungrae
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.118-137
    • /
    • 2004
  • Recently underwater geophysical problems for historical relics or UXO's are raised frequently. This study includes the applicabilities and limitations of the recent underwater metal detector and domestic case stories for underwater survey by electrical and magnetic method. Direct or indirect case stories are electrical and vertical magnetic gradiometry surveys beneath Han-river bottom for planning subway tunnel, electrical exploration on lake-bottom, electrical exploration on the tidal flats using high-power transmitter, and borehole three-component magnetic and electromagnetic surveys for detecting the undersea objects. A design of potable real-time, high-speed measurement system using multi-channel array sensors is also introduced here. Further study will be focussed on practical field applications of the fast water-bottom scanning system which is lately required by actual field.

  • PDF

Development of Microfluidic Chip for Enrichment and DNA Extraction of Bacteria Using Concanavalin A Coated Magnetic Particles (Concanavalin A가 코팅 된 자성 입자를 이용한 미생물 농축 및 유전자 추출 칩 개발)

  • Kwon, Kirok;Gwak, Hogyeong;Hyun, Kyung-A;Jung, Hyo-Il
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.237-241
    • /
    • 2018
  • The real-time enrichment and detection of pathogens are serious issues and rapidly evolving field of research because of the ability of these pathogens to cause infectious diseases. In general, bacterial detection is accomplished by conventional colony counting or by polymerase chain reaction (PCR) after DNA extraction. As colony counting requires considerable time to cultivate, PCR is an attractive method for rapid detection. A small number of pathogens can cause diseases. Hence, a pretreatment process, such as enrichment is essential for detecting bacteria in an actual environment. Thus, in this study, we developed a microfluidic chip capable of performing rapid enrichment of bacteria and the extraction of their genes. A lectin, i.e., Concanavalin A (ConA), which shows binding affinity to the surface of most bacteria, was coated on the surface of magnetic particles to nonspecifically capture bacteria. It was subsequently concentrated through magnetic forces in a microfluidic channel. To lyse the captured bacteria, magnetic particles were irradiated by a wavelength of 532nm. The photo-thermal effect on the particles was sufficient for extracting DNA, which was consequently utilized for the identification of bacteria. Our device will help monitor the existence of bacteria in various environmental situations such as water, air, and soil.

Skin Color Based Hand and Finger Detection for Gesture Recognition in CCTV Surveillance (CCTV 관제에서 동작 인식을 위한 색상 기반 손과 손가락 탐지)

  • Kang, Sung-Kwan;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.1-10
    • /
    • 2011
  • In this paper, we proposed the skin color based hand and finger detection technology for the gesture recognition in CCTV surveillance. The aim of this paper is to present the methodology for hand detection and propose the finger detection method. The detected hand and finger can be used to implement the non-contact mouse. This technology can be used to control the home devices such as home-theater and television. Skin color is used to segment the hand region from background and contour is extracted from the segmented hand. Analysis of contour gives us the location of finger tip in the hand. After detecting the location of the fingertip, this system tracks the fingertip by using only R channel alone, and in recognition of hand motions to apply differential image, such as the removal of useless image shows a robust side. We explain about experiment which relates in fingertip tracking and finger gestures recognition, and experiment result shows the accuracy above 96%.

Proposal and Implementation of 2-D OCDMA System with Reconfigurable Array Encoder/Decoder and Double Hard Limiters (배열형 가변 부호기/복호기와 이중 하드 리미터를 적용한 2-D OCDMA시스템 제안 및 구현)

  • 김진석;김범주;권순영;박종대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.705-711
    • /
    • 2004
  • We propose novel OCDMA system with the structure of reconfigurable may encoder/decoder(RAE/ RAD), which are able to reallocate the 2-D optical codes to each subscriber and recover the transmitted data at all the receiving nodes. We have first implemented the double hard limiters composed of limiting amplifier(first hard limiter) that maintain a level of the encoded data from receiving node and AND detector(second hard limiter) for detecting the position of the encoded data and recovering the data. With the proposed system, it was successfully implemented to recover a specific channel data out of 16 code-multiplxed channels using FPGA and 4 DFB-LDs having distinct wavelengths. From experimental results, the code length resulted from increasing the number of the simultaneously connected channels has been reduced by using 2-D OCDMA multiplexed in time and wavelength instead of 1-D OCDMA. In addition, bit errors phenomenon on account of deterioration of autocorrelation peak-to-side lobe ratio is enhanced by using the double hard limiters composed of AND detector and limiting amplifiers.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

The Concepts of Montage in Somatosensory Evoked Potentials (체성감각 유발 전위에서 montage에 대한 개념)

  • Cha, Jae-Kwan;Kim, Seung-Hyun
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.160-167
    • /
    • 1999
  • Although somatosensory evoked potentials(SSEPs) have been utilized as the useful diagnostic tools in evaluating the wide variety of pathological conditions, such as focal lesions affecting the somatosensory pathways, demyelinating diseases, and detecting the clinically occult abnormality, their neural generators is still considerably uncertain. To appreciate the basis for uncertainties about the origins of SSEPs, consider criteria that must be met to establish a causal relationship between activity in a neural structure and a spine/ scalp-recorded potential. Electrode locations and channel derivations for SSEPs recordings are based on two principles:(1) the waveforms are best recorded from electrode sites on the body surface closest to the presumed generator sources along the somatosensory pathways, and(2) studies of the potential-field distribution of each waveform of interest dictate the best techniques to be used. In this article, authors will describe followings focused on ;(1) the concepts of near field potentials(NFPs) and far field potentials(FFPs) - the voltage of NFPs is highly dependent upon recording electrode position, FFPs are unlike NFPs in that they are widely distributed, their latencies and amplitudes are independent of recording electrode.(2) appropriate montage settings to detect the significant potentials in the median nerve and posterior tibial nerve SSEPs(3) neural generators of various potentials(P9, N13, P14, N18, N20, P37) and their clinical significance in interpretating the results of SSEPs. Especially, Characteristics of N18(longduration, small superimposed inflection) suggested that N18 is a complex wave with multiple generators including brainstem structures and thalamic nuclei. And N18 might be used as the parameter of braindeath. Precise understanding on these facts provide an adequate basis utilizing SSEPs for numerous clinical purposes.

  • PDF

Feasibility Study for Detecting the Tropopause Folding Turbulence Using COMS Geostationary Satellite (천리안 위성 자료를 이용한 대류권계면 접힘 난류 탐지 가능성 연구)

  • Kim, Mijeong;Kim, Jae Hwan
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.119-131
    • /
    • 2017
  • We present and discuss the Tropopause Folding Turbulence Detection (TFTD) algorithm for the Korean Communication, Ocean, Meteorological Satellite (COMS) which is originally developed for the Tropopause Folding Turbulence Product (TFTP) from the Geostationary Operational Environmental Satellite (GOES)-R. The TFTD algorithm assumes that the tropopause folding is linked to the Clear Air Turbulence (CAT), and thereby the tropopause folding areas are detected from the rapid spatial gradients of the upper tropospheric specific humidity. The Layer Averaged Specific Humidity (LASH) is used to represent the upper tropospheric specific humidity calculated using COMS $6.7{\mu}m$ water vapor channel and ERA-interim reanalysis temperature at 300, 400, and 500 hPa. The comparison of LASH with the numerical model specific humidity shows a strong negative correlation of 80% or more. We apply the single threshold, which is determined from sensitivity analysis, for cloud-clearing to overcome strong gradient of LASH at the edge of clouds. The tropopause break lines are detected from the location of strong LASH-gradient using the Canny edge detection based on the image processing technique. The tropopause folding area is defined by expanding the break lines by 2-degree positive gradient direction. The validations of COMS TFTD is performed with Pilot Reports (PIREPs) filtered out Convective Induced Turbulence (CIT) from Dec 2013 to Nov 2014 over the South Korea. The score test shows 0.49 PODy (Probability of Detection 'Yes') and 0.64 PODn (Probability of Detection 'No'). Low POD results from various kinds of CAT reported from PIREPs and the characteristics of high sensitivity in edge detection algorithm.

Improved Cancellation of Impulse Noise Using Rank-Order Method (Rank-Order 방법을 이용한 개선된 임펄스 잡음 제거)

  • Ko, Kyung-Woo;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.4
    • /
    • pp.9-15
    • /
    • 2009
  • This paper proposes a cancellation algorithm of impulse noise using a rank-order method. The proposed method is a fast and simple algorithm that is composed of two parts. The first part involves noise detection using a fuzzy technique, where an image is divided into RGB color channels. Then every pixel in each color channel is investigated and assigned a probability indicating its chances of being a noise pixel. At this time, the rank order method using a noise-detection mask is utilized for accurate noise detection. Thereafter, the second part involves noise-cancellation, where each noise-pixel value in an image is replaced in proportion to its fuzzy probability. Through the experiments, both the conventional and proposed methods were simulated and compared. As a result, it is shown that proposed method is able to detect noisy pixels more accurately, and produce resulting images with high PSNR values.

Suppression Circuit Design of interference Using Orthogonal Signal (직교신호를 이용한 간섭 억제회로 설계)

  • Yoon, Jeoung-Sig;Chong, Jong-Wha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.10A
    • /
    • pp.969-979
    • /
    • 2002
  • This paper proposes an novel method of minimizing Interference which causes data decision error in digital wireless communications. In this method, in order to suppress ISI which is caused by the phase difference between the transmitted and received signal phases, the transmitted and received signals are always kept orthogonal by compensating the transmitted signal for detecting the phase noise and the delay of the received signal was implemented by MOS circuits. To delay the phase of the signal, additive white Gaussian noise (AWGN) environment was used. The phase and delay of the signal transmitted through AWGN channel were compensated in the modulator of the transmitter and the compensated signal was demodulated using quasi-direct conversion receiver and QPSK demodulator. ISI suppression was achieved by keeping the orthogonality between the compensated transmitted signal and the receive signal. The error probability of data decision was compared. By simulation the proposed system was proved to be effective in minimizing the ISI.

Microfluidic Array for Simultaneous Detection of Antigen-antibody Bindings (항원-항체 결합의 동시 검출을 위한 미세 유체 어레이)

  • Bae, Young-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.102-107
    • /
    • 2011
  • In this paper, a microfluidic array biochip for simultaneously detecting multiple antigen-antibody bindings was designed and implemented. The biochip has the single channel in which microreaction chambers are serially connected, and the antibody-coated microbeads are packed in each microreaction chamber. In addition, the weir structure was fabricated in the microchannel using the gray-scale photolithography in order to trap the microbeads in the microreaction chamber. Three kinds of antibodies were chosen, and the antibodies were immobilized onto the microbeads by the streptavidin-biotin conjugation. In the experiment, as the fluorescence-labeled antigens were injected into the microchannel, the antigen-antibody bindings were completed in 10 minutes. When the solution with multiple antigens was injected into the microchannel, it was observed that the fluorescence intensity increased in only the corresponding microreaction chambers with few non-specific binding. The microfluidic array biochip implemented in this study provides, even with the consumption of tiny amount of sample and fast reaction time to simultaneously detect multiple immunoreactions.