• 제목/요약/키워드: Detecting Material

검색결과 357건 처리시간 0.024초

고체전해질을 사용한 $CO_2$가스센서의 응답기구 (Characteristics of Solid Electrolyte $CO_2$ Gas Sensors)

  • 김귀열;박용필;이성일;이원재;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.562-564
    • /
    • 2002
  • In recent years, environments of our globe has been getting worse as a result of rapid growth of socioeconomic activities. The global environmental issues of acid rain, green house effect and ozone depletion are caused by various chemical pollutants, emitted from industries, automobiles and home. Most of these pollutants are produced by combustion processes. CO2 as a chief criminal of the greenhouse effect is a main combustion product of fossil fuels. Development of solid-state electrochemical devices for detecting CO2 is demonstrated based on various combination of solid electrolytes and auxiliary sensing materials. The object of this research is to develop various sensor performance for solid electrolyte gas sensor, and to test gas sensor performance manufactured. So we try to present a guidance for developing potential type gas sensor. We concentrated on development of manufacturing process and performance test.

  • PDF

CoZrNb 막을 이용한 MI센서 제작 및 특성 (Fabrication and Properties of MI Sensor using CoZrNb films)

  • 허진;김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.132-135
    • /
    • 2002
  • MI(Magneto-Impedance) sensor which is made by thin films has significantly high detecting sensitivity in weak magnetic field. It also has a merit to be able to build in the low power system. Its structure is simple, which makes it easier to prepare a miniature. In this study, its magnetic permeability and anisotropy field($H_{k}$) as a function of a thickness of sputtered amorphous CoZrNb films with zero-magnetostriction and soft magnetic property are investigated. In order to make a uniaxial anisotropy, film was subjected to the post annealing in a static magnetic field with 1KOe intensity at 250, 300, and $320^{\circ}C$ respectively for 2 hours. Magnetic properties of film are measured by using a MH loop tracer. Its magnetic permeability of a film is measured over the frequency range 1 MHz to 750MHz. And, it was examined on the permeability and impedance to design the MI sensor which acts at 50MHz by thickening a CoZrNb film relatively, and fabricated the MI sensor which acts at the 50MHz.

  • PDF

폐쇄성 수면 무호흡 검출을 위한 심박동변이율 분석 (Obstructive Sleep Apnea Analysis Based on Heart Rate Variability)

  • 예수영;김정국;김동현
    • 한국전기전자재료학회논문지
    • /
    • 제24권7호
    • /
    • pp.605-608
    • /
    • 2011
  • In this study, OSA (the obstructive sleep apnea) periods were detected in patients with OSA during sleep because of the treatment was different according to the frequency and symptoms of obstructive sleep apnea. ANS (autonomic nervous activity) was changed by obstructive sleep apnea periods so we intended to detect the periods to care the obstructive sleep apnea patients. RR intervals, SDNN (standard deviation of normal to normal) and RMSSD (root mean square standard deviation) were calculated in time domain analysis and LF (low frequency), HF (high frequency), NHF (normalized high frequency), NLF (normalized low frequency) were calculated in frequency domain analysis of HRV (heart rate variability) with obstructive sleep apnea patients. In this paper, SDNN (standard deviation of normal to normal) of time domain analysis were decreased in the obstructive sleep apnea periods. And NLF and LF/HF ratio were increased and NHF (normalized high frequency) was decreased in the frequency domain analysis. The parameters can be used to treat obstructive sleep apnea patients by detecting the obstructive sleep apnea periods such as CPAP (continuous positive airway pressure).

pH 나노센서로의 응용을 위한 UV-가교 P4VP 박막에 고정한 금 나노입자의 특성 (Application of AuNPs immobilized on UV Cross-linked P4VP Thin Film as pH Nanosensors)

  • 김민성;정연태
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1010-1018
    • /
    • 2008
  • In this report, we describe the use of gold nanoparticles (AuNPs) immobilized on pH. responsive, cross-linked poly(4-vinylpyridine) (P4VP) thin films, as a potential application for pH nanosensors. The methodology is based on the variation in surface plasmon resonance of immobilized AuNPs with changing the interparticle distances, caused by the swelling/deswelling of the pH responsive P4VP polymer films. The change in optical properties of the immobilized AuNPs in response to the pH of surrounding media was investigated by a simple yet powerful tool; UV-vis absorption spectroscopy. The swelling of the P4VP chains at pH 2 causes an increase in the interparticle distances of immobilized AUNPS ($\sim20nm$) and hence leads to a blue shift of 48 nm in their surface plasmon resonance band peak. On the other hand, when the surrounding media was altered from pH 2 to 10, a red shift of absorption maxima was observed. The changes were rapid, and the effect was reversible. This system could prove to be useful in fabricating nanosensors for detecting the pH or pH changes of surrounding aqueous medium.

재사용 ESS를 위한 리튬 배터리 덴드라이트 보호 알고리즘 제안 (Proposal Protection Algorithm of Dendritic Lithium for Battery Second Use ESS)

  • 송정용;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제31권6호
    • /
    • pp.422-426
    • /
    • 2018
  • The lithium-ion battery pack of an electric vehicle (EV) deserves to be considered for an alternative use within smart-grid infrastructure. Despite the long automotive service life, EV batteries retain over 70~80% of their initial capacity. These battery packs must be managed for their reliability and safety. Therefore, a battery management system (BMS) should use specific algorithms to measure and estimate the status of the battery. Most importantly, the BMS of a grid-connected energy storage system (ESS) must ensure that the lithium-ion battery does not catch fire or explode due to an internal short from uncontrolled dendrite growth. In other words, the BMS of a lithium-ion battery pack should be capable of detecting the battery's status based on the electrochemical reaction continuously until the end of the battery's lifespan. In this paper, we propose a new protection algorithm for a dendritic lithium battery. The proposed algorithm has applied a parameter from battery pack aging results and has control power managing.

UWB 센서 설계를 통한 고압회전기의 부분방전 진단 연구 (PD Diagnosis On High Voltage Rotating Machines using UWB Sensor)

  • ;임광진;신동훈;김희동;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.197-198
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic pulse emitted from the partial discharge source in the stator winding of HV Rotating Machine with UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on micro-strip technology and made experiments of offline dismantled testing compare with the traditional HFCT as a reference sensor in the laboratory. We investigated internal discharge, surface discharge, corona discharge and non-defected state normal stator on pre-made stator winding by using UWB patch sensor.

  • PDF

Structural and temperature coefficient of resistance characteristics of colossal magnetoresistance Mn oxides prepared by RF sputtering

  • Choi, Sun-Gyu;Ha, Tae-Jung;Reddy, A.Sivasankar;Yu, Byoung-Gon;Park, Hyung-Ho
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.361-361
    • /
    • 2007
  • A lot of efforts have been paid to develop infrared imaging systems in last decades. Bolometer has a wide range of applications from military to commercial, such as military night vision, medical imaging system and so on. Bolometer is a resistive sensor that detects temperature changes through resistance change. To improve detecting ability, bolometer should have a good resistive film which has high temperature coefficient of resistance (TCR) value. Colossal magnetoresistance (CMR) $L_{1-x}A_xMnO_3$ (where L and A are trivalent rare-earth ions and divalent alkaline earth ions, respectively.) are received attention to apply bolometer resistive film because it has a high TCR property which was discovered in the metal to semiconductor phase transition temperature region. In this work, CMR films were deposited on various substrates in relative low substrate temperature by RF magnetron sputtering. The influence of deposition parameters such as substrate temperature, gas partial pressure, and so on have been studied. The structural and TCR properties of the films were also investigated for applying to microbolometer.

  • PDF

폴리우레탄 감지막에 의한 표면탄성파 가스 센서의 감지능 향상 (Improved sensitivity of surface acoustic wave gas sensor by using polyurethane absorption layer)

  • 유범근;박용욱;최두진;김현재;김진상;윤석진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.364-364
    • /
    • 2007
  • This paper presents characteristics of surface acoustic wave (SAW) gas sensor for detecting volatile gases such as ethanol gas by measuring phase shift of output signal. A delay-line with a center frequency of 400MHz was fabricated on 128o Y-Z $LiNbO_3$ substrates. Experimental results, which show the phase change of output signal under the absorption of volatile gas on sensor surface, were presented. The sensitivities of SAW delay lines coated with polyurethane films are greatly increased compared to those for uncoated devices. This SAW gas sensor system may be well suited for a high sensitivity electronic nose system.

  • PDF

웨어러블용 Nylon-Yarn NOx 가스 센서의 검출 온도 변화에 따른 열 특성 시뮬레이션 (Thermal Characteristics Simulation with Detecting Temperature for the Wearable Nylon-Yarn NOx Gas Sensors)

  • 장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제33권4호
    • /
    • pp.321-325
    • /
    • 2020
  • Atmospheric environmental problems have a major impact on human health and lifestyle. In humans, inhalation of nitrogen oxides causes respiratory diseases, such as bronchitis. In this paper, thermal analysis of a gas sensor was carried out to design and fabricate a wearable nylon-yarn gas sensor for the detection of NOx gas. In the thermal analysis method, the thermal diffusion process was analyzed while operating the sensors at 40 and 60℃ to secure a temperature range that does not cause thermal runaway due to temperature in the operating environment. Thermal diffusion analysis was performed using the COMSOL software. The thermal analysis results could be useful for analyzing gas adsorption and desorption, as well as the design of gas sensors. The thermal energy diffusion rate increased slightly from 10.05 to 10.1 K/mm as the sensor temperature increased from 40 to 60℃. It was concluded that the sensor could be operated in this temperature range without thermal breakdown.

저항형 고온 초전도 전류제한기의 저항변화 분석 (Anaysis of resistance variance of Resistive type high-Tc superconducting fault current limiter)

  • 박형민;최효상;임성훈;박충렬;한병성;정헌상;최창주;현옥배;정동철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.547-550
    • /
    • 2004
  • Superconducting fault current limiter(SFCL) is expected to be introduced into electric power system in future as an effective countermeasure for the increase of the short-circuit current due to the growth of the electric power system. SFCL has a merit that the fault current can be limited by the resistance generated when a superconductor transits from a superconducting state to a normal state without additional detecting device. In this paper, we investigated the resistance variance of resistive type SFCL and the fault current limiting characteristics due to the amplitude of source voltage. We could obtain the more effective fault current limiting characteristics of SFCL as the source voltage increased.

  • PDF