• 제목/요약/키워드: Detailed model

검색결과 2,936건 처리시간 0.027초

중소형 플랜트의 표준화된 플랜트 엔지니어링 활동 모델 개발: 상세설계를 중심으로 (Development of Standard Activity Model for Small and Medium sized Plant: Focused on Detailed Design Phase)

  • 신중욱;염충섭
    • 시스템엔지니어링학술지
    • /
    • 제14권1호
    • /
    • pp.13-18
    • /
    • 2018
  • Plant Engineering is a series of activities going through following life cycle phases: planning, basic design, detailed design, procurement and construction, commissioning, operation and maintenance, to produce a target product. From among these phases of plant engineering life cycle, a detailed design phase is an important phase producing final design deliveries. Luckily, through technical co-operation and experiences of constructing plants, large Korean engineering companies have accumulated know-hows of efficient detailed designs. However, smaller engineering companies have less experience of performing detailed designs so there is always a risk of causing design errors in the detailed design phase. To mitigate the risk of design errors in the detailed design phase, it is necessary to systematize a concrete activity model of a detailed design phase. In this paper, we have developed a prototype of a detailed design activity model through a widely used function modeling methodology called IDEF0.

초기사정을 위한 간호정보조사지의 임상내용 모델 개발 (Development of Detailed Clinical Models of Nursing Information for Initial Assessment)

  • 김영란;박현애;민열하;이명경;이영지
    • 임상간호연구
    • /
    • 제17권1호
    • /
    • pp.101-112
    • /
    • 2011
  • Purpose: The purpose of this study is to develop a detailed clinical model for recording initial nursing assessment items, and to test the applicability of the model to facilitate semantic interoperability for sharing and exchanging nursing information. Methods: First, the researchers extracted items by analyzing initial nursing assessment records. Second, defining characteristics were identified by analyzing nursing records and reviewing the literature. Third, value sets for defining characteristics were identified and types and cardinalities of defining characteristics were defined based on the value sets. Finally, the detailed clinical model was tested through evaluation by experts and comparison with the initial nursing assessment in a clinical setting. Results: Sixty-one detailed clinical models were developed with 178 defining characteristics and value sets. The experts evaluation and comparison with the initial nursing assessment in a clinical setting showed that the detailed clinical model developed in this study was valid. Conclusion: Use of this detailed clinical model can ensure that the Electronic Health Record contains meaningful and valid information and supports semantic interoperability of nursing information. This use will promote quality in the nursing records and eventually quality of nursing care.

Modeling of non-seismically detailed columns subjected to reversed cyclic loadings

  • Tran, Cao Thanh Ngoc
    • Structural Engineering and Mechanics
    • /
    • 제44권2호
    • /
    • pp.163-178
    • /
    • 2012
  • A strut-and-tie model is introduced in this paper to predict the ultimate shear strength of non-seismically detailed columns. The validity and applicability of the proposed strut-and-tie model are evaluated by comparison with available experimental data. The model was developed based on visible crack patterns observed on the test specimens. The concrete contribution is integrated into the strut-and-tie model through a concept of equivalent transverse reinforcement. To further validate the model a full-scale non-seismically detailed reinforced concrete column was tested to investigate its seismic behavior. The specimen was tested under the combination of a constant axial load, $0.30f_c{^{\prime}}A_g$ and quasi-static cyclic loadings simulating earthquake actions. Quasi-static cyclic loadings simulating earthquake actions were applied to the specimen until it could not sustain the applied axial load. The analytical results reveal that the strut-and-tie method is capable of modeling to a satisfactory accuracy the ultimate shear strength of non-seismically detailed columns subjected to reserved cyclic loadings.

데토네이션 파 해석을 위한 탄화수소 연료/산화제의 Induction Parameter Modeling (Induction Parameter Modeling of Hydrocarbon Fuel/Oxidizer for Detonation Wave Analysis)

  • 최정열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.57-62
    • /
    • 2003
  • A general procedure of obtaining reliable one-step kinetics model for hydrocarbon mixture from the fully detailed chemistry is described iin this study. One-step theoretical formulation of the induction parameter model IPM uses a theoretical reconstruction of the induction time database obtained from a detailed kinetics library. Non-dimensional induction time calculations is compared with that of detailed kinetics. The IPM was latter implemented to fluid dynamics code and applied for the numerical simulation of detonation wave propagation. The numerical results including the numerical smoked-foil record show the all the details of the detonation wave propagation characteristics at the cost around 1/100 of the detailed kinetics calculation.

  • PDF

HWSD와 정밀토양도를 이용한 유출해석시 토양 매개변수 특성 비교 평가 (Soil Related Parameters Assessment Comparing Runoff Analysis using Harmonized World Soil Database (HWSD) and Detailed Soil Map)

  • 최윤석;정영훈;김주훈;김경탁
    • 한국농공학회논문집
    • /
    • 제58권4호
    • /
    • pp.57-66
    • /
    • 2016
  • Harmonized World Soil Database (HWSD) including the global soil information has been implemented to the runoff analysis in many watersheds of the world. However, its accuracy can be a critical issue in the modeling because of the limitation the low resolution reflecting the physical properties of soil in a watershed. Accordingly, this study attempted to assess the effect of HWSD in modeling by comparing parameters of the rainfall-runoff model using HWSD with the detailed soil map. For this, Grid based Rainfall-runoff Model (GRM) was employed in the Hyangseok watershed. The results showed that both of two soil maps in the rainfall-runoff model are able to well capture the observed runoff. However, compared with the detailed soil map, HWSD produced more uncertainty in the GRM parameters related to soil depth and hydraulic conductivity during the calibrations than the detailed soil map. Therefore, the uncertainty from the limited information on soil texture in HWSD should be considered for better calibration of a rainfall-runoff model.

열해석 모델 간략화 및 동적특성에 관한 연구 (A STUDY ON THERMAL MODEL REDUCTION AND DYNAMIC RESPONSE)

  • 전형열;김정훈
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.37-44
    • /
    • 2014
  • A detailed satellite panel thermal model composed of more than thousands nodes can not be directly integrated into a spacecraft thermal model due to its node size and the limitation of commercial satellite thermal analysis programs. For the integration of the panel into the satellite thermal model, a reduced thermal model having proper accuracy is required. A thermal model reduction method was developed and validated by using a geostationary satellite panel. The temperature differences of main components between the detailed and the reduced thermal model were less than $1^{\circ}C$ in steady state analysis. Also, the dynamic responses of the detailed and the reduced thermal model show very similar trends. Thus, the developed reduction method can be applicable to actual satellite thermal design and analysis with resonable accuracy and convenience.

액체저장탱크의 지진응답해석 모델 중 빔 모델의 적용성 (Applicability of Beam Model among Earthquake Response Analysis Models of Liquid-Storage Tank)

  • 진병무;전세진;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.696-699
    • /
    • 2004
  • Generally, the time history analysis among seismic response analyses of a structure needs more times than static analysis. Therefore the mechanical model of a structure has been used as a simple lumped parameter model in time history analysis. For the most cases, the simple mechanical model shows the similar results to that of detailed finite element model. so it is reasonable to use the simple mode] in preliminary analysis. In seismic design of liquid storage tank, such as LNG storage tank, the lumped parameter mode] also is being used in preliminary analysis, however sometimes shows the differences to the results of detailed finite element model. Therefore in this study, the dynamic characteristics between lumped parameter model and detailed finite model is compared for the variables such as height/diameter of liquid-storage tank and thickness of wall, then the applicability of beam mode] to the seismic response analysis are evaluated for some liquid storage tanks.

  • PDF

3D 문화재 데이터의 LOD 기반 상세정보 브라우징 기술 (Detailed-information Browsing Technology based on Level of Detail for 3D Cultural Asset Data)

  • 정정일;조진수;황보택근
    • 한국콘텐츠학회논문지
    • /
    • 제9권10호
    • /
    • pp.110-121
    • /
    • 2009
  • 본 논문에서는 건조물 문화재의 대용량 3D 데이터를 LOD(Level of Detail) 모델로 가공하고, 이를 기반으로 시스템의 메모리 제약을 완화시켜 사용자에게 3D모델에 대해 정밀한 상세정보를 제공하는 방법을 제안한다. 제안한 방법은 먼저 변형한 AOSP 알고리즘으로 3D 데이터에 대한 계층적 공간구조를 생성하고, 생성된 공간구조에 대한 표면 간략화를 수행하여 LOD 모델을 생성한다. 다음으로 간략화 된 LOD 모델에서 사용자의 관심 영역을 추출하고, 추출된 영역에 대하여 국부 상세화를 수행한 후 최종적으로 관심영역에 원 모델과 동일한 표면의 상세정보를 형성하여 렌더링 한다. 제안한 방법의 성능 평가를 위하여 정밀하게 실측된 건조물 문화재의 3D 스캔 데이터들로 실험을 진행하였다. 제안한 방법은 간략화 된 LOD 모델의 메쉬(mesh) 구조를 기반으로 관심 영역에서만 원 모델과 동일한 메쉬 구조를 형성함으로써, 기존의 모든 데이터를 메모리에 적재하여 렌더링을 하는 방법과 동일한 상세정보를 제공하면서도 메모리의 사용량을 평균적으로 45% 절감하여, 제원이 낮은 보급형 PC 환경에서도 대용량의 건조물 문화재를 정밀하게 관찰할 수 있었다.

인공위성 영상기의 열모델링 방법 (THERMAL MODELING TECHNIQUE FOR A SATELLITE IMAGER)

  • 김정훈;전형열;유명종;김병수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.174-180
    • /
    • 2010
  • Conductive and radiative thermal model configurations of an imager of a geostationary satellite are presented. A two-plane method is introduced for three dimensional conductive coupling which is not able to be treated by thin shell plate thermal modeling technique. Especially the two-plane method is applied to massive matters and PIP(Payload Interface Plate) in the imager model. Some massive matters in the thermal model are modified by adequate correction factors or equivalent thickness in order to obtain the numerical results of thermal modeling to be consistent with the analytic model. More detailed nodal breakdown is specially employed to the object which has the rapid temperature gradient expected by a rule of thumb. This detailed thermal model of the imager is supposed to be used for detailed analyses and test predictions, and be correlated with the thermal vacuum test results before final in-flight predictions.

  • PDF

볼트결합부를 포함한 구조물의 정적 및 동적 해석을 위한 유한요소 모델링 (Finite Element Modeling for Static and Dynamic Analysis of Structures with Bolted Joints)

  • 권영두;구남서;김성윤;조민호
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.667-676
    • /
    • 2002
  • Many studies on the finite element modeling for bolted joints have proceeded, but the structures with bolted joints are complicated in shape and it is difficult to find out the characteristics according to joint condition. Usually, experimental methods have been used for bolted joint analysis. A reliable and practical finite element modeling technique for structure with bolted joints is very important for engineers in industry. In this study, three kinds of model are presented; a detailed model, a practical model and a simple model. The detailed model is modeled by using 3-D solid element and gap element, and the practical model is modeled by using shell element (a portion of bolt head) and beam element (a portion of bolt body), the simple model is modeled by simplifying practical model without using gap elements. Among these models, the simple model has the least degree of freedom and show the effect of memory reduction of 59%, when compared with the detailed model.