• Title/Summary/Keyword: Detachable coil

Search Result 28, Processing Time 0.032 seconds

Transcarotid Coil Embolization in a Yorkshire Terrier Puppy with Patent Ductus Arteriosus Using a JR Coronary Catheter and Free Push Deployment System (동맥관 개존증에 걸린 요크셔테러어종 자견에서 경동맥 경로와 JR Coronary Catheter/Free Push Deployment System을 이용한 색전코일을 이용한 치료증례)

  • Choi, Bum-Sul;Choi, Ran;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.28 no.2
    • /
    • pp.240-243
    • /
    • 2011
  • Several vascular accesses can be used for catheter guided coil embolization for occluding patent ductus arteriosus (PDA). Although trans-femoral approach is most commonly used in dogs, it is often unable to insert angiocatheter for inserting the coil delivery system, especially small puppies weighing less than 2 kg of body weight. Therefore this case study developed trans-carotid method for puppy using JR coronary catheter and free push delivery system. Using this new method, we successfully treated a puppy with PDA weighing 1.25 of body weight.

A Study of the WPT Module Using Inductive Coupling for the Convergence Applications (융합형 어플리케이션을 위한 자기유도 방식의 무선전력전송 모듈설계에 대한 연구)

  • Jeong, Byeong-Ho;Park, Ju-Hoon;Kang, Bo-An
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.2
    • /
    • pp.57-64
    • /
    • 2015
  • Inductive Power Transfer (IPT) systems have successfully been developed and used to replace traditional conductive power transfer systems where physical connection is either inconvenient or impossible, such as biomedical implants, undersea vehicles, and contactless battery chargers of robots, for providing power to movable or detachable loads. Inductive Coupling uses magnetic fields to transfer power. There is a primary coil, which generates a magnetic field. Then there is another secondary coil which is composed of a capacitor and a coil, the capacitor creates a circuit with the primary and secondary coils. This paper discusses design method and several implementation alternatives for wireless energy transmission systems. It presents realization examples for these alternatives. Wireless energy transmission is investigated in numerous convergence applications due to its simplicity and advantages.

Angiographic Follow-up Result of Cerebral Aneurysms Treated with Coils Covered with Polyglycolic-Polylactic Acid Copolymer

  • Kim, In-Cheol;Chun, Young-Il;Park, Cheol-Wan;Park, Chan-Woo;Lee, Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.286-291
    • /
    • 2006
  • Objective : We evaluate the effect of the copolymer-coated coils on immediate occlusion of the aneurysm, preventing rupture, and decreasing compaction or re-growth. Methods : Thirty-five aneurysms treated between September 2003 and December 2004 using Matrix detachable coil were reviewed. Study population consisted of 12 men and 23 women ranging in age from 34 to 75 years[mean, 55.1 years]. Twenty-two aneurysms were ruptured and 23 aneurysms were located in the anterior circulation. Follow-up angiography was obtained in 16 patients after 6 months from the procedure. Results : Initial complete occlusion was achieved in 17 aneurysms[48.6%], and the others remained as a residual neck in 8 aneurysms[22.8%] and residual sac in 10 aneurysms[28.6%]. Among these incompletely occluded aneurysms, 7 aneurysms were performed follow-up angiography. And 6 of them converted into complete occlusion. In the other hands, among 17 aneurysms achieved complete occlusion initially, 9 aneurysms were performed follow-up angiography. Recurrence due to coil compaction occurred in one aneurysm and the others maintained complete occlusion. There was one mortality case due to thromboembolic complication. Conclusion : In spite of difficulty in achieving complete occlusion with Matrix coil system, there is no rupture or re-rupture during follow-up period. Follow-up angiography shows many conversions of residual sac into complete occlusion. Embolization using Matrix coil system is safe and effective, but the effects of PGLA copolymer need further investigation.

Surgical Clipping of Intracranial Aneurysm Regrown after Endovascular Coiling

  • Bang, Jae-Seung;Kim, Gook-Ki;Lee, Seung-Hwan;Kim, Seung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.59-63
    • /
    • 2007
  • Operative clipping after previous endovascular coiling in an aneurysm is a different problem from primary clipping procedure for neurosurgeons. With the increasing use of coil embolization, neurosurgeons will more and more face the similar situation. We report surgical clipping cases of intracranial aneurysm regrown after endovascular coiling. Three patients with a history of subarachnoid hemorrhage due to ruptured aneurysm underwent endovascular treatment (EVT) with detachable coils. The aneurysms were in the posterior communicating artery, the middle cerebral artery and distal anterior cerebral artery (DACA). Two near-total occlusions and one partial occlusion were achieved by EVT. After several months, angiographic follow-up revealed regrowth of the aneurysm requiring surgical clipping. Here, we report three cases in which surgical clipping was more difficult than a usual clipping procedure performed several months after EVT, because of adhesion and coil bulging into the aneurysmal neck. The difficulty of the treatment of the residual aneurysm after coiling is discussed, as are the surgical complications and limitations of clipping.

Antegrade Recanalization of Parent Artery after Internal Trapping of Ruptured Vertebral Artery Dissecting Aneurysm

  • Ihn, Yon-Kwon;Sung, Jae-Hoon;Byun, Je-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.5
    • /
    • pp.301-304
    • /
    • 2012
  • We report a patient with a ruptured vertebral artery (VA) dissecting aneurysm that was treated by internal trapping of the aneurysm and parent artery using detachable coils with subsequent antegrade recanalization of occluded vertebral artery during the follow-up period. A 38-year-old man was admitted with a ruptured right VA dissecting aneurysm just distal to origin of right posterior inferior cerebellar artery. The dissected segment of the VA was occluded by coil embolization. The 14 months follow-up angiography showed that dissected aneurysm was completely occluded, but the parent artery was recanalized in an antegrade fashion. Based on this unique case, the authors suggest that careful angiographic follow-up of dissecting aneurysm is required, even in patients successfully treated with endovascular occlusion of the affected artery and aneurysm.

Direct Carotid Cavernous Fistula of an Adult-Type Persistent Primitive Trigeminal Artery with Multiple Vascular Variations

  • Jin, Sung-Chul;Park, Hyun;Kwon, Do-Hoon;Choi, Choong-Gon
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.226-228
    • /
    • 2011
  • We report a case of spontaneous right carotid-cavernous fistula (CCF) in a proximal segment of persistent primitive trigeminal artery (PPTA) and combined vascular anomalies such as left duplicated hypoplastic proximal posterior cerebral arteries and a variation of anterior choroidal artery supplying temporal and occipital lobe. A 45-year-old male presented with progressive right exophthalmos, diplopia, and ocular pain. With manual compression of the internal carotid artery, a cerebral angiography revealed a right CCF from a PPTA. Treatment involved the placement of detachable non-fibered and fibered coils, and use of a hyperglide balloon to protect against coil herniation into the internal carotid artery. A final angiograph revealed complete occlusion of PPTA resulted in no contrast filling of CCF.

Cerebral Hemorrhage after Endovascular Treatment of Bilateral Traumatic Carotid Cavernous Fistulae with Covered Stents

  • Cho, Kwang-Chun;Seo, Dae-Hee;Choe, Il-Seung;Park, Sung-Choon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.2
    • /
    • pp.126-129
    • /
    • 2011
  • Bilateral traumatic carotid-cavernous fistulae (TCCFs) is rarely encountered neurovascular disease. For treatment of TCCF, detachable balloons have been widely used. Nowadays, transarterial and/or transvenous coil embolization with placement of covered stents is adopted as another treatment method. We experienced a patient with a bilateral TCCFs who was successfully treated with covered stents. However, cerebral hemorrhage occurred in the bed of previous infarction one day after treatment. Hyperperfusion syndrome was considered as a possible cause of the hemorrhage, so that barbiturate coma therapy was started and progression of hemorrhage was stopped. We emphasize that cerebral hyperperfusion hemorrhage can occur even after successful endovascular treatment of TCCF.

Strategy for the Patient with Tuberculum Sellae Meningioma Combining Bilateral Internal Artery Aneurysm

  • Cha, Ki-Yong;Park, Sang-Keun;Hwang, Yong-Soon;Kim, Tae-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.2
    • /
    • pp.151-154
    • /
    • 2005
  • A 43-year-old woman was admitted with the chief complaint of progressive visual disturbance and her brain radiological studies disclosed well demarcated tumor at tuberculum sellae area and bilateral mirror image paraclinoid internal carotid artery saccular aneurysms. A larger left side aneurysm was pointing medialy and almost encased by the tumor. Although a brain tumor and intracranial aneurysm can be simultaneously treated by surgery, the high risk of intra-operative aneurysm rupture should be considered. Therefore, the author secondly performed tumor resection after the endovascular embolization of the aneurysm which was embedding the tumor using a Guglielmi detachable coil. After successful treatment of the patient with tuberculum sellae meningioma associated with bilateral mirror image paraclinoid aneurysms using endovascular and surgical techniques, the authors present the case with a review of the related literatures.

Design and Experimental Implementation of Easily Detachable Permanent Magnet Reluctance Wheel for Wall-Climbing Mobile Robot

  • Kim, Jin-Ho;Park, Se-Myung;Kim, Je-Hoon;Lee, Jae-Yong
    • Journal of Magnetics
    • /
    • v.15 no.3
    • /
    • pp.128-131
    • /
    • 2010
  • In this paper, we propose a new design of the permanent magnet reluctance wheel which will make it possible to attach the robot to a vertical plane and move it. In the newly suggested design, a permanent magnet is utilized to enhance the adhesive force during attachment, and an electromagnet is produced to weaken the magnetic field of the permanent magnet and reduce the adhesive force for easier detachment of wheels from steel plates. To characterize the performance of this new wheel design, a 3-D finite element analysis is executed using a commercial FE program. The results show that the adhesive force is reduced effectively by the electromagnet which flows in the reverse direction of the magnetic loop of the permanent magnet when the current is supplied to the coil.

The Clinical Comparative Investigation of Endovascular Treatment Using GDC and Neurosurgical Operation's Decision for Intracranial Aneurysm (뇌동맥류에 대한 방사선학적 중재적 시술과 신경외과학적 수술 선택의 임상적 비교 고찰)

  • Kim Sang Jin;Go Jung Seok;You Sang Jae;Kim Gyeong Sul;Choi Kwang Nam;Lee Yong Woo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.90-96
    • /
    • 2002
  • Purpose : The purpose of this study is to compare and analyze matters related to procedure such as characteristics and conditions etc. of intracranial aneurysm of patients who were treated GDC(Guglielmi Detachable Coil : Endovascular Treatment) and patien

  • PDF