• Title/Summary/Keyword: Detachable Biochip

Search Result 2, Processing Time 0.016 seconds

Development of Detachable PDMS/Glass PCR-Chip and It's Application to Detection of Male Infertility (분리식 PDMS/유리 중합효소연쇄반응칩 개발 및 유전적 남성불임 검사에의 응용)

  • Ju, Jin-Kyoung;Hwang, Seung-Young;Ahn, Yoo-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.4
    • /
    • pp.371-377
    • /
    • 2008
  • Our precedent study has reported glass-PDMS (polydimethylsiloxane) based biochip for the gene PCR (polymerase chain reaction). To prevent the contamination of bio sample, the once used biochip must not be used repeatedly. However, the fabrication cost of microheater and microsensor of the biochip was not cheap to use it as a disposable chip. This paper proposes new PCR-chip where the glass substrate integrated with the microheater and microsensor is detachable from the reaction chamber where the sample is injected. That makes it possible to reuse the glass substrate repeatedly. The performance of the proposed detachable PCR-chip was compared with that of the precedent monolithic PCR-chip. The results showed that the SRY (sex determining Y chromosome) gene PCR was successfully performed in the detachable chip compared with the monolithic chip. However, the more efforts to improve the efficiency of surface treatment of PDMS chip are needed to increase the possibility of applying the detachable chip to the detecting of male infertility.

A Study About PDMS-Glass Based Thermopneumatic Micropump Integrated with Check Valve (체크밸브가 달린 열공압 방식의 PDMS-유리마이크로 펌프에 관한 연구)

  • Ko, Young-June;Cho, Woong;Ahn, Yoo-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.720-727
    • /
    • 2008
  • Microfluidic single chip integrating thermopneumatic micropump and micro check valve are developed. The micropump and micorvalve are made of biocompatible materials, glass and PDMS, so as to be applicable to the biochip. By using the passive-type check valve, backward flow and fluid leakage are blocked and flow control is stable and precise. The chip is composed of three PDMS layers and a glass substrate. In the chip, flow channel and pump chamber were made on the PDMS layers by the replica molding technique and pump heater was made on the glass substrate by Cr/Au deposition. Diameter of the pump chamber is 7 mm and the width and depth of the channel are 200 and $180{\mu}m$, respectively. The PDMS layers chip and the heater deposited glass chip are combined by a jig and a clamp for pumping operation, and they are separable so that PDMS chip is used as a disposable but the heater chip is able to be used repeatedly. Pumping performance was simulated by CFD software and investigated experimentally. The performance was the best when the duty ratio of the applied voltage to the heater was 33%.