• 제목/요약/키워드: Desorption gas

검색결과 253건 처리시간 0.03초

Adsorption and Thermal Regeneration of Toluene and Benzene on the Fixed Bed Packed with Activated Carbon and Activated Carbon Fiber

  • Kim, Jong-Hwa;Oh, Ok-Kyun;Haam, Seung-Joo;Lee, Chang-Ha;Kim, Woo-Sik
    • Carbon letters
    • /
    • 제2권1호
    • /
    • pp.44-54
    • /
    • 2001
  • The characteristics of adsorption and desorption of benzene and toluene were investigated at a fixed bed packed with the activated carbon and activated carbon fiber. Through breakthrough experiments under various feed concentration conditions, it was found that the slope of mass transfer zone and the tailing in the breakthrough curves were different from the feed conditions due to different heats of adsorption. In hot nitrogen desorption, the regeneration time and mass transfer zone of the toluene desorption curve were longer than those of the benzene desorption curve because of the difference in adsorption affinity. With an increase in the regeneration temperature, the height of roll-up and the sharpness of desorption curves increased but the regeneration times decreased. The adsorption capacities of the activated carbon and activated carbon fiber after three-time thermal regenerations decreased about 25% and 37% for benzene and 18% and 25% for toluene, respectively. To investigate the effect of the regeneration temperature on the energetic efficiency, the characteristic desorption temperatures of toluene and benzene were investigated by calculating purge gas consumption and temperature.

  • PDF

역류식 충전탑에서 이산화탄소 탈착과 수력학절 거동에 관한 연구 (A Study on Hydraulic Behavior and Desorption of $CO_2$ Gas in the Counter-current Packing Tower)

  • 김석택
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.94-100
    • /
    • 2000
  • This study was carried out to interpret hydraulic behavior and CO2 gas desorption in counter-current packing tower which packed 50mm plastic Hiflow-ring. The results are as follow : To compare with conventional packing, 50mm Hiflow-ring could save energy because of low pressure drop under high load. As relative error between calculated value and investigated value was less than 6% in the loading point and flooding point we found that we are predict results mathematically which occur in packing tower. The unique magnitude of packing which was used are as follows. $C_L=2.1{\times}10^{-4}$, n=0.787 so we can predict efficiency which occur

  • PDF

제올라이트의 아황산가스흡 ${\cdot}$ 탈착특성 (Adsorption characteristics of the zeolite for flue gas desulfurization)

  • 박현희;모세영
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.43-47
    • /
    • 2003
  • The desorption characteristics of NaY zeolite, of which Si/Al ratio is 2.36, was measured at 25${\circ}$C and 150${\circ}$C so as to be used practically as a adsorbent for separation of sulfur oxides from flue gas, for which adsorption and desorption cycles at 25${\circ}$C were repeated four times and that at 150${\circ}$C was done one time. As a result it took 30.8 at 150${\circ}$C and 164.1 minutes in average at 25${\circ}$C to reach equilibrium condition. It means that regeneration of the NaY zeolite can be done below 150${\circ}$C so that zeolite can be used for flue gas desulfurization.

제올라이트 5A와 13X의 저농도 이산화탄소 흡착 및 탈착특성 (Adsorption and Desorption Characteristics of Carbon Dioxide at Low Concentration on Zeolite 5A and 13X)

  • 조영민;이지윤;권순박;박덕신;최진식;이주열
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.191-200
    • /
    • 2011
  • A way to adsorptively remove indoor carbon dioxide at relatively lower concentration under ambient temperature was studied. A small lab-scale carbon dioxide adsorption and desorption reactors were prepared, and 5A and 13X zeolites were packed in this reactors to investigate their adsorption and desorption characteristics. The inflow carbon dioxide concentration was controlled to 5,000 ppm, relatively higher concentration found in indoor spaces with air quality problems, by diluting carbon dioxide with nitrogen gas. The flow rate was varied as 1~5 L/min, and the carbon dioxide concentration after this reactor was constantly monitored to examine the adsorption characteristics. It was found that 5A adsorbed more carbon dioxide than 13X. A lab-scale carbon dioxide desorption reactor was also prepared to investigate the desorption characteristics of zeolites, which is essential for the regeneration of used zeolites. The desorption temperature was varied as $25{\sim}200^{\circ}C$, and the desorption pressure was varied as 0.1~1.0 bar. Carbon dioxide desorbed better at higher temperature, and lower pressure. 5A could be regenerated more than three times by thermal desorption at $180^{\circ}C$. It is required to modify zeolites for higher adsorption and better regeneration performances.

Si(100)에 주입된 불활성 기체 이온들의 방출 특성 (Thermal Effusion of Implanted Inert Gas Ions from Si(100))

  • 조삼근
    • 한국진공학회지
    • /
    • 제15권1호
    • /
    • pp.73-80
    • /
    • 2006
  • Si(100)에 주입된 불활성 기체 이온들의 열적 방출 특성을 열탈착(temperature-programmed desorption; TPD) 질량분석법으로 고찰하였다. 약 400K의 표면 온도 조건에서 1keV 비온빔에 시료를 노출시켜 주었을 때, He은 $500\~1100 K$의 넓은 온도 범위에서 Si(100)결정 밖으로 분출되어 나온 반면, Ne, Ar, 및 Kr은 각각 810, 860, 875 K 근처에서 매우 좁은 온도 범위에서 TPD 피크를 나타내며 급격하게 방출되었다. He+ 이온으로 처리된 Si(100)은 표면 원자 구조의 손상이 상대적으로 최소한으로 일어났지만, $Ne^+,\;Ar^+,\;Kr^+$ 등의 이온들로 처리된 경우는 질량이 클수록 표면이 원자 스케일로 더 심하게 손상되었음이 수소 흡탈착 분석 결과로 밝혀졌다. 이온빔에 의한 결정 내부의 결함 생성과 관련하여 이러한 실험적 결과가 시사하는 점들을 논의하였다

Fabrication of In-needle Microextraction Device Using Nichrome Wire Coated with Poly(ethylene glycol) and Poly(dimethylsiloxane) for Determination of Volatile Compounds in Lavender Oils

  • Lee, Eun Ji;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.211-217
    • /
    • 2014
  • A new needle-based device for headspace wire coated in-needle microextraction (HS-WC-INME) was fabricated using a nichrome wire coated with poly(ethylene glycol) (PEG) and poly(dimethylsiloxane) (PDMS) mixture. The proposed needle device was applied for the determination of volatile compounds in lavender and lavandin essential oils by gas chromatography. Fundamental parameters such as needle design, conditions of extraction and desorption were optimized along with the validation of the extraction and desorption efficiency. The optimal conditions were 30 min extraction at $50^{\circ}C$ and 2 min desorption at $240^{\circ}C$. The calibration curves showed good linearity with the suitable values of the coefficients of determination ($r^2$) greater than 0.99. The limits of detection for linalyl acetate, ${\beta}$-caryophyllene, linalool and (+)-limonene were 7.15, 9.04, 10.79 and 22.26 ng, respectively. Analytical recoveries were acceptable in the test samples, varying from 86.7% to 108.0%. The values of relative standard deviations for run to run showed range less than 0.9% while 3.9% through 7.2% for needle to needle. The proposed PEG-PDMS coating could be more suitable than PDMS coating to extract particular polar groups such as alcohols.

Gas Chromatograph에 의한 Arylmethy Halides의 정량 (Determination of Arylmethyl Halides by Gas Chromatograph)

  • 오도석;최호춘
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.25-32
    • /
    • 1994
  • Arylmethyl halides(benzyl chloride, BZYC; benzal chloride, BZYA; benzotrichloride, BZTC) and related compounds(benzyl alcohol, BZYA; benzoyl chloride, BZOC) were determined by GC using capillary column. Detailed results are as follows. 1. Stability In methanol benzotrichloride slowly transferred to benzoyl chloride by hydrolysis(ca. 7.5% for 5 days), but the others were stable. Therefore, benzotrichloride solution should be prepared just before analysis. 2. GC analysis Tenax-GC was used to absorbent and desorption solvents were $CCl_4$ and MeOH. Arylmethyl halides were analyzed within 7.5min without interference with related compounds. The calibration curve(ca. 15-80 ppm in soln), repeatability(n=10) and the desorption efficiency were good. Limit of detection by NIOSH method was about 0.003 ppm for arylmethyl halide, respectively. To analyze arylmethyl halides and related compounds in working places GC using capillary column is anticipated to be used effectively.

  • PDF