• Title/Summary/Keyword: Design wind speed

Search Result 657, Processing Time 0.026 seconds

Analysis of Weather Data for Design of Biological Production Facility (생물생산시설 설계용 기상자료 분석)

  • Lee, Suk-Gun;Lee, Jong-Won;Lee, Hyun-Woo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.156-163
    • /
    • 2005
  • This study was attempted to provide some fundamental data for safety structrural design of biological production facility. Wind load and snow load, acting on agricultural structures is working more sensitive than any other load. Therefore, wind speed and snow depth according to return periods for design load estimation were calculated by frequency analysis using the weather data(maximum instantaneous wind speed, maximum wind speed, maximum depth of snow cover and fall) of 68 regions in Korea. Equations for estimating maximum instantaneous wind speed with maximum wind speed were developed for all, inland and seaside regions. The results were about the same as the current eqution in general. Design wind speed and snow depth according to return periods were calculated and Local design wind load and snow load depending on return periods were presented together with iso-wind speed and iso-snow depth maps. The calculated design snow depth by maximum depth of snow cover were higher than design snow depth by maximum depth of snow fall. Considering wind speed and snow depth, protected cultivation is very difficult in Ullungdo, Gangwon seaside and contiguity inland regions, and strong structural design is needed in the west-south seaside against wind speed, and structure design of biological production facility in these regions need special consideration.

  • PDF

Proposal of Return Period and Basic Wind Speed Map to Estimate Wind Loads for Strength Design in Korea (강도설계용 풍하중 평가를 위한 재현기간과 기본풍속지도의 제안)

  • Ha, Young-Cheol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.29-40
    • /
    • 2018
  • Strength design wind loads for the wind resistance design of structures shall be evaluated by the product of wind loads calculated based on the basic wind speed with 100 years return period and the wind load factor 1.3 specified in the provisions of load combinations in Korean Building Code (KBC) 2016. It may be sure that the wind load factor 1.3 in KBC(2016) had not been determined by probabilistic method or empirical method using meteorological wind speed data in Korea. In this paper, wind load factors were evaluated by probabilistic method and empirical method. The annual maximum 10 minutes mean wind speed data at 69 meteorological stations during past 40 years from 1973 to 2012 were selected for this evaluation. From the comparison of the results of those two method, it can be found that the mean values of wind load factors calculated both probability based method and empirical based method were similar at all meteorological stations. When target level of reliability index is set up 2.5, the mean value of wind load factors for all regions should be presented about 1.35. When target level of reliability index is set up 3.0, wind load factor should be presented about 1.46. By using the relationship between importance factor(conversion factor for return period) and wind load factor, the return periods for strength design were estimated and expected wind speeds of all regions accounting for strength design were proposed. It can be found that return period to estimate wind loads for strength design should be 500 years and 800 years in according to target level of reliability index 2.5 and 3.0, respectively. The 500 years basic wind speed map for strength design was suggested and it can be used with a wind load factor 1.0.

Detecting artefacts in analyses of extreme wind speeds

  • Cook, Nicholas J.
    • Wind and Structures
    • /
    • v.19 no.3
    • /
    • pp.271-294
    • /
    • 2014
  • The impact of artefacts in archived wind observations on the design wind speed obtained by extreme value analysis is demonstrated using case studies. A signpost protocol for detecting candidate artefacts is described and its performance assessed by comparing results against previously validated data. The protocol targets artefacts by exploiting the serial correlation between observations. Additional "sieve" algorithms are proposed to identify types of correctable artefact from their "signature" in the data. In extreme value analysis, artefacts displace valid observations only when they are larger, hence always increase the design wind speed. Care must be taken not identify large valid values as artefacts, since their removal will tend to underestimate the design wind speed.

A systematic comparison of the wind profile codifications in the Western Pacific Region

  • Jiayao Wang;Tim K.T. Tse;Sunwei Li;Tsz Kin Chan;Jimmy C.H. Fung
    • Wind and Structures
    • /
    • v.37 no.2
    • /
    • pp.105-115
    • /
    • 2023
  • Structural design includes calculation of the wind speed as one of the major steps in the design process for wind loading. Accurate determination of design wind speed is vital in achieving safety that is consistent with the economy of construction. It is noticeable that many countries and regions such as Hong Kong, Japan and Australia regularly make amendments to improve the accuracy of wind load estimations for their wind codes and standards. This study compares the latest Hong Kong wind code published in 2019, which is generally known as the Code of Practice on Wind Effects in Hong Kong - 2019, with the latest revision of the AIJ Recommendations for Loads on Buildings - 2015 (Japan), and the Australian/New Zealand Standard, AS/NZS 1170.2:2021. The comparisons include the variations between the design wind speed and the vertical profiles of wind speed multipliers. The primary purpose of this study was to show any differences in the basic design wind speed and exposure factor estimations among the three economies located in the Western Pacific Ocean. Subsequently, the reasons for such underlying variations between the three documents, are discussed, together with future development trends.

A design of vertical axis wind power generating system combined with Darrieus-Savonius for adaptation of variable wind speed (다변풍속 적응형 Darrieus-Sauonius 초합 수직푹 풍력발전 시스템의 설계)

  • 서영택;오철수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.185-192
    • /
    • 1996
  • This paper presents a design of vertical axis Darrieus wind turbine combine with Savonius for wind-power generating system to be adapted for variable wind speed. The wind turbine consists of two troposkien- and four Savonius-blades. Darrieus turbine is designed with diameter 9.4[m], chord length 380[mm], tip speed ratio 5. Savonius turbine is designed with diameter 1.8[m], height 2[m], tip speed ratio 0.95. The design of turbine is laid for the main data of rated wind speed 10[m/s], turbine speed 101.4[rpm]. The generating power is estimated to maximum power 20[kW], and this is converted to commercial power line by means of three phase synchronous generator-inverter system. Generating system is designed for operation on VSVF(variable speed variable frequency) condition and constant voltage system.

  • PDF

Joint distribution of wind speed and direction in the context of field measurement

  • Wang, Hao;Tao, Tianyou;Wu, Teng;Mao, Jianxiao;Li, Aiqun
    • Wind and Structures
    • /
    • v.20 no.5
    • /
    • pp.701-718
    • /
    • 2015
  • The joint distribution of wind speed and wind direction at a bridge site is vital to the estimation of the basic wind speed, and hence to the wind-induced vibration analysis of long-span bridges. Instead of the conventional way relying on the weather stations, this study proposed an alternate approach to obtain the original records of wind speed and the corresponding directions based on field measurement supported by the Structural Health Monitoring System (SHMS). Specifically, SHMS of Sutong Cable-stayed Bridge (SCB) is utilized to study the basic wind speed with directional information. Four anemometers are installed in the SHMS of SCB: upstream and downstream of the main deck center, top of the north and south tower respectively. Using the recorded wind data from SHMS, the joint distribution of wind speed and direction is investigated based on statistical methods, and then the basic wind speeds in 10-year and 100-year recurrence intervals at these four key positions are calculated. Analytical results verify the reliability of the recorded wind data from SHMS, and indicate that the joint probability model for the extreme wind speed at SCB site fits well with the Weibull model. It is shown that the calculated basic wind speed is reduced by considering the influence of wind direction. Compared to the design basic wind speed in the Specification of China, basic wind speed considering the influence of direction or not is much smaller, indicating a high safety coefficient in the design of SCB. The results obtained in this study can provide not only references for further wind-resistance research of SCB, but also improve the understanding of the safety coefficient for wind-resistance design of other engineering structures in the similar area.

Updates of Korean Design Standard (KDS) on the wind load assessment and performance-based wind design

  • Han Sol Lee;Seung Yong Jeong;Thomas H.-K. Kang
    • Wind and Structures
    • /
    • v.37 no.2
    • /
    • pp.117-131
    • /
    • 2023
  • Korea Design Standard (KDS) will be updated with two major revisions on the assessment of wind load and performance-based wind design (PBWD). Major changes on the wind load assessment are the wind load factor and basic wind speed. Wind load factor in KDS is reduced from 1.3 to 1, and mean recurrence interval (MRI) for basic wind speed increases from 100 years to 500 years considering the reduction of wind load factor. Additional modification is made including pressure coefficient, torsional moment coefficient and spectrum, and aeroelastic instability. Combined effect of the updates of KDS code on the assessment of wind load is discussed with the case study on the specified sites and building. PBWD is newly added in KDS code to consider the cases with various target performance, vortex-induced vibration, aeroelastic instability, or inelastic behavior. Proposed methods and target performance for PBWD in KDS code are introduced.

Design of Speed Controller for Stall Blade Wind Turbine Complying with the Speed Limit During Speed Overshoot (속도 오버슈트 발생 시 제한 속도를 초과하지 않는 실속형 블레이드 풍력터빈의 속도제어기 설계)

  • Kim, Ye-Chan;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.438-445
    • /
    • 2022
  • Blade efficiency decreases when the rotor speed is kept constant even though the wind speed is higher than the rated value. Therefore, a speed controller is used to regulate the rotor speed in the high-wind-speed region. In stall-blade wind turbine, the role of the speed controller is important because precise aerodynamic regulation is unavailable. In this study, an effective parameter design method of a PI speed controller is proposed to limit the speed overshoot of a type 4 wind turbine with stall blades even though wind gust occurs. The proposed method considers the efficiency characteristics of the stall blade and the mechanical inertia of the wind turbine rotor. It determines the bandwidth of the speed controller to comply with the speed limit during generator speed overshoot for the worst case of wind gust. The proposed method is verified through intensive simulations with a MATLAB/SIMULINK model and experimental results obtained using a 3 kW MG set of wind turbine simulator.

Wind load equation for electric power facility design (전력시설물 설계를 위한 풍하중 산정식)

  • Choi, Sang-Hyun;Seo, Kyung-Seok;Lee, Su-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.42-54
    • /
    • 2009
  • The wind load equation for the design of electric power facilities such as electrical pole in railroad is based on the maximum wind velocity without considering regional difference in wind velocities. Also, the use of a different equation to highspeed railroad and the possibility of higher wind speed due to climate change claims a new design equation. In this paper, a wind load equation based on wind speed measurement data to date, which is applicable to both conventional and highspeed railroad is proposed. The proposed equation considers the regional differences in wind speed for economic and effective design, and the possibility of higher wind speed due to climate change.

  • PDF

Reliability of microwave towers against extreme winds

  • Deoliya, Rajesh;Datta, T.K.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.5
    • /
    • pp.555-569
    • /
    • 1998
  • The reliability of antenna tower designed for a n-year design wind speed is determined by considering the variability of the strength of the component members and of the mean wind speed. For obtaining the n-year design wind speed, maximum annual wind speed is assumed to follow Gumbel Type-1 distribution. Following this distribution of the wind speed, the mean and standard deviation of stresses in each component member are worked out. The variability of the strength of members is defined by means of the nominal strength and a coefficient of variation. The probability of failure of the critical members of tower is determined by the first order second moment method (FOSM) of reliability analysis. Using the above method, the reliability against allowable stress failure of the critical members as well as the system reliabilities for a 75 m tall antenna tower, designed for n-year design wind speed, are presented.