• Title/Summary/Keyword: Design of rehabilitation system

Search Result 304, Processing Time 0.022 seconds

The Treatment Strategies of Non-surgical Approach for Dentofacial Asymmetry Patient (치열 안면 비대칭 환자의 비수술적 절충치료의 전략적 접근)

  • Lee, Kyung-Min;Lee, Sang-Min;Yang, Byung-Ho;Yun, Min-Sung;Lee, Ju-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.77-87
    • /
    • 2010
  • Skeletodental asymmetries are common and asymmetric orthodontic treatments are very difficult to correct successfully. The cause of asymmetries can be the skeletal asymmetry, dental, or functional, or combinations of these causes. Skeletodental asymmetries can be the result of congenital factors, such as hemifacial microsomia and environmental factors, such as trauma. Optimal treatment outcome of the severe facial asymmetry requires the orthognathic surgery. Mild asymmetry problem can be treated by only orthodontic treatment. The orthodontic treatment of asymmetry is usually difficult. Facial asymmetry orthodontic treatment are primarily based on proper diagnosis and careful treatment planning. Side effects of asymmetric elastic to treat midline discrepancies are canted occlusal plane, tipped incisors and unesthetic results. In the management of dental arch asymmetries, the clinician should select the appropriate force system and the appliance design necessary to address the asymmetry while minimizing undesirable side effects. This report presents treatment strategies for the treatment of skeletodental asymmetry. In this case report, the clinical case with midline discrepancies treated by optimal mechanics is described. Through diagnosis and strategic treatment mechanics can obtain proper midline correction with minimal side effects.

Design of an Optimal Adaptive Filter for the Cancellation of M-wave in the EMG Controlled Functional Electrical Stimulation for Paralyzed Individuals (마비환자의 근전도제에기능적전기자극을 위한 M-wave 제거용 최적적응필터 설계)

  • Yeom Hojoon;Park Youngcheol;Lee Younghee;Yoon Youngro;Shin Taemin;Yoon Hyoungro
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.479-487
    • /
    • 2004
  • Biopotential signals have been used as command in systems using electrical stimulation of motor nerves to restore movement after an injury to the central nervous system (CNS). In order to use the voluntary EMG (electromyography) among the biopotentials as a control signal for the electrical stimulation of the same muscle for CNS injury patients, it is necessary to remove M-wave of having high magnitude from raw data. We designed an optimal filter for removing the M-wave and preserving the voluntary EMG and showed that the optimal filter is eigen filter. We also proved that the previous method using the prediction error filter(PEF) is a suboptimal filtering in the sense of preserving the voluntary EMG. On basis of the data obtained from a model for M-wave and voluntary EMG and from actual CNS injury patients, with false-positive rate analysis, the proposed adaptive filter showed a very promising performance in comparison with previous method.

Three-Dimensional Finite Element Analysis of Internal Connection Implant System (Gsii$^{(R)}$) According to Three Different Abutments and Prosthetic Design (국산 내부연결형 임플란트시스템(GS II$^{(R)}$)에서 지대주 연결방식에 따른 응력분석에 관한 연구)

  • Jang, Mi-Ra;Kwak, Ju-Hee;Kim, Myung-Rae;Park, Eun-Jin;Park, Ji-Marn;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.179-195
    • /
    • 2010
  • In the internal connection system, the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. The purpose of this study was to assess the loading distributing characteristics of three different abutments for GS II$^{(R)}$ implant fixture(Osstem, Korea) under vertical and inclined loading using finite element analysis. Three finite element models were designed according to three abutments; 2-piece Transfer$^{TM}$ abutment made of pure titanium(GST), 2-piece GoldCast$^{TM}$ abutment made of gold alloy(GSG), 3-piece Convertible$^{TM}$ abutment with external connection(GSC). This study simulated loads of 100N in a vertical direction on the central pit(load 1), on the buccal cusp tip(load 2) and $30^{\circ}$ inward inclined direction on the central pit(load 3), and on the buccal cusp tip(load 4). The following results were obtained. 1. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture and lower stress was taken at the cancellous bone. 2. When off-axis loading was applied, high stress concentration observed in cervical area. 3. GSG showed even stress distribution in crown, abutment and fixture. GST showed high stress concentration in fixture and abutment screw. GSC showed high stress concentration in fixture and abutment. 4. Maximum von Mises stress in the surrounding bone had no difference among three abutment type. In GS II$^{(R)}$ conical implant system, different stress distribution pattern was showed according to the abutment type and the stress-induced pattern at the supporting bone according to the abutment type had no difference among them.

The Public Health Welfare Conception of the Beveridge Report and Its Realization via the NHS (베버리지 보고서의 의료보장 구상과 NHS를 통한 구현)

  • Juneyoub Han;Jiyong Park
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.3
    • /
    • pp.59-104
    • /
    • 2023
  • This essay attempts to analyze the public health welfare conception within the text of the Beveridge Report and its realization via the NHS in Great Britain. Once referring to the influence of the Report to create the foundations of the 20th-century welfare system, the quest to scrutinize the original intentions of the Report and its succession to the NHS is certainly intriguing. Furthermore, when regarding the significance of public health policy for a modern state, the effort to engage in Beveridge's conception and its realization is more than timely. In light of such a premise, this paper indulges in its study by the following methods. First, the historical background of the Report - namely, the role of the spirit of the age and the experience of the Emergency Medical Service are to be analyzed to identify the origins of the welfare policies proposed by Beveridge. Furthermore, the public health welfare conception of the Report conceived from its time is reflected upon by engaging on the goal towards social welfare and public health scheme. Lastly, the aims of the NHS and its management, treatment classification, and rehabilitation program are reviewed for comparative analysis with the Report to survey the realization of Beveridge's design. In this process, this paper not only takes into account the original text of the Report - but also other essential works of law and public policy, including the NHS Constitution for England and the National Health Service Act of 1946. The intentions of this study are not bound by merely coinciding with the Report, but resonate significance via reflecting upon the Beveridgian legacy on the modern welfare state from the current perspective. The structured analysis to research the aims and policies of the Report and to compare them to the reality of the NHS may provide an opportunity to confirm the realization of Beveridge's scheme in British society. In addition, this essay is part of an academic endeavor to critically assess the past and the present of the welfare institution in the public health sector. As such, it is hopeful that the essay sheds light on further studies concerning the constructive remedies of the Korean welfare system as well.