• Title/Summary/Keyword: Design frequency

Search Result 11,313, Processing Time 0.035 seconds

A UHF-band Passive Temperature Sensor Tag Chip Fabricated in $0.18-{\mu}m$ CMOS Process ($0.18-{\mu}m$ CMOS 공정으로 제작된 UHF 대역 수동형 온도 센서 태그 칩)

  • Pham, Duy-Dong;Hwang, Sang-Kyun;Chung, Jin-Yong;Lee, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.45-52
    • /
    • 2008
  • We investigated the design of an RF-powered, wireless temperature sensor tag chip using $0.18-{\mu}m$ CMOS technology. The transponder generates its own power supply from small incident RF signal using Schottky diodes in voltage multiplier. Ambient temperature is measured using a new low-power temperature-to-voltage converter, and an 8-bit single-slope ADC converts the measured voltage to digital data. ASK demodulator and digital control are combined to identify unique transponder (ID) sent by base station for multi-transponder applications. The measurement of the temperature sensor tag chip showed a resolution of $0.64^{\circ}C/LSB$ in the range from $20^{\circ}C$ to $100^{\circ}C$, which is suitable for environmental temperature monitoring. The chip size is $1.1{\times}0.34mm^2$, and operates at clock frequency of 100 kHz while consuming $64{\mu}W$ power. The temperature sensor required a -11 dBm RF input power, supported a conversion rate of 12.5 k-samples/sec, and a maximum error of $0.5^{\circ}C$.

Design of A Microstrip Linear Tapered Slot Antenna (마이크로스트립 선형 테이퍼형 슬롯 안테나 설계)

  • Jang, Jae-Sam;Kim, Cheol-Bok;Lee, Ho-Sang;Jung, Young-Ho;Jo, Dong-Ki;Lee, Mun-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.5
    • /
    • pp.40-45
    • /
    • 2008
  • In this paper, a microstrip linear tapered slot antenna is designed. A tapered slot antenna(TSA) has many advantages such as low profile, low weight, easy fabrication, and compatibility with monolithic microwave integrated circuits(MMIC). In addition, it has demonstrated multi octave bandwidth, moderately high gain, and symmetrical E- and H-plane beam patterns. A feed network is implemented with transition between a microstrip and a slot line for the microstrip linear tapered slot antenna. The transition is consist of two sides. One side has a microstrip line, the other side has a slot line. The dimensions of the microstrip and slot line are ${\lambda}_m/4$ and ${\lambda}_s/4$ at the center of the cross section of the microstrip and slot line. In order to get broad bandwidth antenna characteristics, the tapered length is chosen as $4{\lambda}_o$ and termination width is chosen as $1.75{\lambda}_o$. Experimental results show that the microstrip tapered slot antenna has symmetrical E- and H-plane beam patterns with around 5GHz of bandwidth at center frequency of 5.0GHz.

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

Design of a Broadband Receiving Active Dipole Antenna Using an Equivalent Model (등가 모델을 이용한 광대역 수신용 능동 다이폴 안테나 설계)

  • Lee, Cheol-Soo;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.23-32
    • /
    • 2008
  • In the VHF range, active antennas are widely used for wideband applications due to their small size. Active antenna consists of antenna elements and amplifiers, which are directly connected to each other. Gain and noise-figure characteristics are very important for good sensitivity performance, because it is located at the front end of a receiving system. In this study, we developed an active dipole antenna with 5:1 bandwidth(100${\sim}$500 MHz), which consists of a dipole antenna and a P-HEMT amplifier. To obtain required performances, the antenna and the amplifier should be designed simultaneously. In order for that, we introduced an equivalent port concept to model the 1-port dipole antenna as an equivalent 2-port system. Using the proposed equivalent port, the performance of the active dipole antenna was simulated by the ADS. In order to measure the gain and noise-figure characteristics of the antenna, we utilized the same concept of the two-port equivalent impedance model. The measurement results for typical gain, NF and VSWR in the required frequency band were 8dBi, 9dB and 1.7:1, respectively. The radiation patterns at the principal planes were same as the typical radiation pattern of a dipole antenna. By comparing the simulation results with measured ones, it is confirmed that the proposed methods works well.

A Design of High Efficiency Distributed Amplifier Using Optimum Transmission Line (최적 전송 선로를 이용한 고효율 분산형 증폭기의 설계)

  • Choi, Heung-Jae;Ryu, Nam-Sik;Jeong, Young-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • In this paper, we propose a numerical analysis on reversed current of distributed amplifier based on transmission line theory and proposed a theory to obtain optimum transmission line length to minimize the reversed currents by cancelling those components. The reversed current is analyzed as being simply absorbed into the terminal resistance in the conventional analysis. In the proposed analysis, however, they are designed to be cancelled by each other with opposite phase by the optimal length of the transmission lint Circuit simulation and implementation using pHEMT transistor were performed to validate the proposed theory with the cutoff frequency of 3.6 GHz. From the measurement, maximum gain of 14.5dB and minimum gain of 12.3dB were achieved In the operation band. Moreover, measured efficiency of the proposed distributed amplifier is 25.6% at 3 GHz, which is 7.6%, higher than the conventional distributed amplifier. Measured output power Is about 10.9dBm, achieving 1.7dB higher output power than the conventional one. Those improvement is thought to be based on the cancellation of refersed current.

The Effects of Child Cardiopulmonary Resuscitation Education for Childcare Teachers with a Video Self-Instruction Program (Video Self-Instruction Program을 이용한 보육교사의 소아심폐소생술 교육의 효과)

  • Kim, Geon-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.2
    • /
    • pp.87-98
    • /
    • 2009
  • Purpose : This study set out to compare the educational effects of a video self-instruction program for child CPR education on childcare teachers by applying the 2006 KACPR Guideline. By adopting the nonequivalent control group posttest quasi-experimental design, the study examined the educational effects on a group that did not receive instructions from the instructor, another group that received his instructions, and the other group that received an extra three-minute practice training session in addition to instructions. Methods : Data were gathered from August 6 to 18, 2008. As for research tools, the Knowledge Instrument of CPR by Connolly (2006) was used along with the National Practice Test Protocol for C1ass 1 Emergency Medical Technicians (2007) and Common Protocol for CPR (2006) to examine the performance of child CPR. By shooting the guide screen of $Resusci^{(R)}$ Junior CPR Manikin of Leardal with a video camera and using the Skill Guide Checklist of the Common Protocol for CPR (2006), the subjects' technical accuracy of chi1d CPR was evaluated. There were three subject groups: 29 childcare teachers randomly assigned to received the video self-instruction program training for chi1d CPR and no instructions from the instructor made up the control group; 22 childcare teachers randomly assigned to received the program training and instructions from the instructor made up experiment group I; 23 childcare teachers randomly assigned to received an extra three-minute practice training session in addition to the program training and the instructions made up experiment group II. The gathered data were analyzed with SPSS/PC+ (Version 14.0) in frequency, percentage, $X^2$-test, ANOVA, Scheffe test. Results : 1) There were no statistically significant differences (F=1.030, p=.362) among the groups in terms of knowledge scores after the child CPR education. 2) There were statistically significant differences (F=13.625, p=.000) among the groups in terms of performance abilities after the child CPR education. 3) There were no statistically significant differences (F=1.610, p=.207) among the groups in terms of technical accuracy of mouth-to-mouth resuscitation after the child CPR education 4) There were no statistically significant differences (F=1.484, p=.234) among the groups in terms of technical accuracy of chest compression after the child CPR education. Conclusion : The results indicate that childcare teachers can improve their performance abilities in child CPR when the instructors are active with their instructions and extra practice hours are secured through a VSI program. It's also needed to provide education with increasing concentration ratio about the items of lower knowledge points in order to help the teachers learn the accurate theory of child CPR. And there should be VSI programs of diverse conditions to increase the effects of child CPR training among childcare teachers.

  • PDF

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

Upper Garment Sizing System for Obese School Boys Based on Somatotype Analysis (학령후기 비만 남아의 체형 분석에 따른 plus-size 남자 아동복 상의 치수 규격 제안)

  • Park, Soon-Jee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.99-112
    • /
    • 2008
  • The increasing rate of obesity in school aged children has become a conspicuous social phenomenon in Korea. This has been linked to greater economic growth, increasingly westernized dietary habits, and a consumer driven society. Given that obesity can lead to social exclusion or unfavorable attention by other students in a school setting, the design of plus-size garments have become important for effective appearance management skills. This research aimed to establish a somatotype database for obese school boys, aged 10 to 12, in order to develop a sizing system for plus-size upper garments. In order to measure somatotype of average and obese school boys, five categories were recorded; height, obesity, length of trunk, thickness of neck and chest. For obese boys, subcutaneous fat thickness and position of B.P/shoulder point factors were recorded. Obesity factor was subdivided into overall and specific ones, and while the deviation of obese body types was severe compared to the average type. Obese body type showed significantly higher measurements in width, girth, thickness. This is linked to the fact that the frequency ratio of obesity increases with age. Stature and chest were chosen as control dimensions for boys' wear. As crosstabulation of stature(5cm interval) and chest girth(2, 3 and 4cm), and stature(5cm interval)/chest girth(3cm interval) sizing system showed, the most effective cover ratio and adaptability to the data distribution $25{\sim}75$ quartile. Based on the findings, 10 sizes were formulated for average body type, while 18 sizes were formulated for obese type, whose size cover ratios were 48% and 62.9%, respectively. The primary ranges of stature were $145cm{\sim}150cm$, while those of chest girth were $79{\sim}82cm$. Each size was declared as "chest-somatotype{A(average)/O(obesity)-stature". This study proposed a plus-size upper garment sizing systems for obese boys, accompanied with reference measurements for suit, casual wear and underwear. The finding showed that the two systems were totally separate and not overlapping, meaning that plus-size sizing system is essential for obese school boys. The obesity type system had more size and wider range specs.

A Study on Buffeting Responses of a In-service Steel Cable-stayed Bridge Using Full-scale Measurements (실측 데이터를 이용한 공용중인 강사장교의 버페팅 응답 분석)

  • Lee, Deok Keun;Kong, Min Joon;You, Dong Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.349-359
    • /
    • 2016
  • In order to analytically evaluate buffeting responses, the analysis of wind characteristics such as turbulence intensity, turbulence length, gust, roughness coefficient, etc must be a priority. Static aerodynamic force coefficients, flutter coefficients, structural damping ratios, aerodynamic damping ratios and natural frequencies affect the analytical responses. The bridge interested in this paper has being been used for 32 years. As the time passes, current terrain conditions around the bridge are different markedly from the conditions it was built 32 years ago. Also, wind environments were considerably varied by the climate change. For this reason, it is necessary to evaluate the turbulence intensity, length, spectrum and roughness coefficient of the bridge site from full-scale measurements using the structural health monitoring system. The evaluation results indicate that wind characteristics of bridge site is analogous to that of open terrain although the bridge is located on the coastal area. To calculate buffeting responses, the analysis variables such as damping ratios, static aerodynamic force coefficients and natural frequency were evaluated from measured data. The analysis was performed with regard to 4 cases. The evaluated variables from measured data are applied to the first and second analysis cases. And the other analysis cases were performed based on Design Guidelines for Steel Cable Supported Bridges. The calculated responses of each analysis cases are compared with the buffeting response measured at less than 25m/s wind speed. It is verified that the responses by the numerical analysis applying the estimated variables based on full-scale measurements are well agreed with the measured actual buffeting responses under wind speed 25m/s. Also, the extreme wind speed corresponding to a recurrence interval 200 years is derived from Gumbel distribution. The derived wind speed for return period of 200 years is 45m/s. Therefore the buffeting responses at wind speed 45m/s is determined by the analysis applying the estimated variables.

Study on tension-tension fatigue strength properties of underwater welded joints of SM41A-2 Plate-to-Plate (수중용접한 국산 SM41A-2강판의 편진반복 인장하중하의 피로강도특성에 관한 연구)

  • 오세규;박주성;한상덕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.71-81
    • /
    • 1987
  • Nowadays, the high development of industrial technique demands the optimal design of marine structures to be welded under the water, because the underwater welding of the ship hull and marine structures can decrease manpower and cost of production. However there is not available at present any report on fatigue behavior about underwater welded joints. In this paper under tention- tension repeated fatigue stress with frequency of 10 cycles per second by local controlled system, the fatigue strength properties of underwater welded joints of SM41A-2 Plate-to-Plate of 10 mm thickness were experimentally examined. The results obtained were as follows : 1) The fatigue strength of underwater welded joints of SM41A-2 was peaked at the heat input of about 1, 400 joule/mm(180 A, 36 V), while, at the heat input of more than about 1, 100 joule/mm (160 A, 33 V) that of the underwater welds at the higher than cycle of life rather than the lower cycle was higher than that of the base metal but lower than that of the atmosphere welds on account of both cooling and notch effects. 2) The fatigue limit of underwater welds increased with an increase of heat input resulting in a peak of that at the heat input of about 1, 400 joule/mm and then decreased gradually. 3) The fatigue strength at N cycles was peaked between the heat input of about 1, 400 and 1, 700 joule/mm where the strain was rapidly increased. 4) It was confirmed that the optimal zone of heat input condition for obtaining the underwater welds fatigue strength higher than that of the base metal exists, and if out of this zone, the fatigue strength of the underwater welds was lower than that of the base metal because of lack weld penetration, inclusion of slag, voids, etc. 5) By the fatigue test, the underwater welds fractured brittly without visual deformation, so the strain was remarkably less than of the atmosphere welds. 6) The fatigue life factor was peaked at the heat input of about 1, 600 joule/mm (200 A, 36 V) at which the mean strain is a little higher than that of the base metal but quite lower than those of the atmosphere welds, resulting in good underwater welds because both fatigue strength and ductility of the underwater welds are higher than those of the base metal at such heat input.

  • PDF