• Title/Summary/Keyword: Design connection

Search Result 2,580, Processing Time 0.027 seconds

A Study on the Characteristics of the Connecting Space between Subway & Shopping Area - Focused on the Subway Station in Seoul - (지하철역과 쇼핑센터의 연계공간 구성적 특성에 관한 연구 - 서울시 소재 지하철 역사를 중심으로 -)

  • 이남규
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 2004
  • To realize the above concepts of underground space, several underground facilities are concentrated upon and around subway stations in harmony with underground pedestrian walkways. As a result, the reduction of transit time and pedestrian distance make it easy to get to an object. In this study, underground space is considered not just as pedestrian walkways, but as space for various activities and as a positive element in connection with its circumstances. The purpose of the study is to understand underground space's elements and develop more aesthetic and efficient design of the space to give mental composure and familiarity to users. The development of underground connection space is one of the methods to improve the quality of the whole downtown area. This paper studied the general characteristics of connection space and space improvements after spot inspections and suggested several aspects useful for substantial design as essential data for development of underground connection space.

Seismic Performance of RC Bridge Columns with Longitudinal Steel Lap Splice (겹침이음 상세에 따른 철근콘크리트 교각의 내진성능)

  • 이재훈;손혁수;석상근;정철호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.345-352
    • /
    • 2001
  • Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seisimc performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.

  • PDF

A Study on the Application of Biophilic Design Pattern in Educational space (아동 교육 공간의 바이오필릭 디자인 패턴 적용 분석)

  • Choi, Joo-young;Park, Sung-jun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.27 no.3
    • /
    • pp.3-14
    • /
    • 2020
  • The purpose of this study is to discuss the planning direction of educational spaces to support children's healthy and creative learning based on bio_philic theory. This study analyzed the characteristics of the application of biophilic patterns in children's education space through case analysis. The conclusion of this study is summarized as follows. As a result of the analysis of children's classroom space, the pattern of 'A(Visual connection with nature), F(Dynamic & Diffuse Light), K(Prospect)' shows high application rate, but the pattern of 'C(Non-Rhythmic Sensory Stimuli), G(Connection with Natural Systems), I(Material Connection with Nature)' shows low application rate. In particular, there is a lack of connection with patterns such as hearing, smell, touch, taste stimulation and water experience, and curiosity through exploration of nature about 'B(Non-visual connection with nature), E(Presence of Water), N(Risk/Peril)' changes in nature and ecosystem. In the corridor and rest space, the pattern of 'A(Visual connection with nature), D(Thermal & Airflow Variability), F(Dynamic & Diffuse Light), G(Connection with Natural Systems), K(Prospect)' shows high application rate, but 'B(Non-visual connection with nature)' shows low application rate. In addition, the application of patterns related to the stimulation of curiosity through direct exploration of nature and the exploration of the patterns of 'E(Presence of Water), N(Risk/Peril)' is insufficient. Therefore, in the case of classroom spaces, the active use of nature as it is should be considered within the scope that does not cause visual confusion, and it should provide an area that can be experienced through the five senses. And corridors and rest spaces should be designed to introduce more active natural elements as spaces to recover stress caused by learning. In other words, the characteristics of children's education facilities need to be connected between classroom space, corridor, rest space and external space. This study is meaningful in that it analyzes and derives the application characteristics of 'biophilic design' which affects the 'Attention Restoration' of children's educational spaces through foreign cases.

Design Formula for the Flexural Strength of a Double Split Tee Connection (상·하부 스플릿 T 접합부의 휨강도 설계식)

  • Yang, Jae-Gue;Kim, Joo-Wo;Kim, Yu
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.511-520
    • /
    • 2012
  • The double split Tee connection, a type of full strength-partially restrained connection, has adequate flexural strength according to the changes in the thickness of the T-stub flange and the gauge distance of the high-strength bolts. Moreover, the double split Tee connection is designed and constructed with seismic connections that have enough ductility capacity applicable to ordinary moment frame and special moment frame by grade of steel, size of beam and column and geometric connection shape. However, such a domestic research and a proposal of a suitable design formula about the double split Tee connection are insufficient. Thus, many experimental and analytical studies are in need for the domestic application of the double split Tee connection. Therefore, this study aimed to examine and suggest feasibility of a design formula of the double split Tee connection of FEMA.

Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections

  • Siadat, Hakimeh;Beyabanaki, Elaheh;Mousavi, Niloufar;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS. Two regular platform dental implants, one with external connection ($Br{\aa}nemark$, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Seven titanium and seven customized zirconia abutments were used for each connection design. Measurements of geometry, marginal discrepancy, and rotational freedom were done using video measuring machine. To measure the torque loss, each abutment was torqued to 35 Ncm and then opened by means of a digital torque wrench. Data were analyzed with two-way ANOVA and t-test at ${\alpha}=0.05$ of significance. RESULTS. There were significant differences in the geometrical measurements and rotational freedom between abutments of two connection groups (P<.001). Also, the results showed significant differences between titanium abutments of internal and external connection implants in terms of rotational freedom (P<.001). Not only customized internal abutments but also customized external abutments did not have the exact geometry of prefabricated abutments (P<.001). However, neither connection type (P=.15) nor abutment material (P=.38) affected torque loss. CONCLUSION. Abutments with internal connection showed less rotational freedom. However, better marginal fit was observed in externally connected abutments. Also, customized abutments with either connection could not duplicate the exact geometry of their corresponding prefabricated abutment. However, neither abutment connection nor material affected torque loss values.

Improvement of Shear Connection Design Procedure using Connections Standardization Database (접합부 표준화 데이터베이스를 활용한 전단접합 설계 프로세스 개선)

  • Kim, Hee Dong;Hwang, In Kyu;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.2
    • /
    • pp.81-89
    • /
    • 2014
  • Investigation results on shear connections design procedure which is conducted in Korea show that there are many communication problems between structural engineer and detailer, and there are unnecessary work procedures. To solve conventional connection design procedure problems, improved shear connection design procedure is suggested. Most of suggested design procedure is controlled by structure engineer, and the introduction of connections standardization makes computer aided design possible. Standardized connection details are satisfied with structural safety and constructability, and it improves design efficiency. Many problems which are caused by conventional design procedure are fundamentally blocked by using suggested design procedure.

Topology Optimization of Connection Component System Using Density Distribution Method (밀도분포법을 이용한 부재의 연결구조 최적화)

  • 한석영;유재원
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

Structural performance evaluation of bolted end-plate connections in a half-through railway inclined girder

  • Jung Hyun Kim;Chang Su Shim
    • Steel and Composite Structures
    • /
    • v.49 no.5
    • /
    • pp.473-486
    • /
    • 2023
  • A through-railway bridge with an inclined girder has recently been applied to optimize the cross-section of a slender bridge structure in railway bridges. To achieve the additional cross-section optimization effect by the bolted end-plate connection, it is necessary to investigate the application of the bolted end-plate tension connection between the inclined girder and the crossbeam. This basic study was conducted on the application of the bolted end-plate moment connection of crossbeams to half-through girders with inclined webs. The combined behavior of vertical deflection and rotational behavior was observed due to the effect of the web inclination in the inclined girder where the steel crossbeam was connected to the girder by the bolted end-plate moment connection. Therefore, in the experiment, the deflection of the inclined girder was 1.77-2.93 times greater than that of the vertical girder but the lateral deflection of the inclined girder was 0.4 times less than that of the vertical girder. Moreover, the tensile stress of the upper bolts in the inclined girder with low crossbeams was clearly 0.81 times lower than that of the vertical girder. According to the results, the design formula for vertical girders does not reflect the influence of the web inclination. Therefore, this study proposed the design procedures for the inclined girder to apply the bolted end-plate moment connection of the crossbeam to the inclined girder by reflecting the design change factors according to the effect of the web inclination.

Behavior and design of stainless steel tubular member welded end connections

  • Kiymaz, Guven;Seckin, Edip
    • Steel and Composite Structures
    • /
    • v.17 no.3
    • /
    • pp.253-269
    • /
    • 2014
  • Among the various alternatives to make a steel tubular member connection, making a slotted and gusset plate welded connection is one of the most frequently preferred alternatives. This type of connection is essentially an end connection that is made by slotting the tube longitudinally, inserting the gusset plate and then placing longitudinal fillet welds at the tube-to-plate interface. In this paper an experimental study on the behaviour of such connections in stainless steel is presented. 24 specimens were tested under concentrically applied axial tensile forces for varying tube-to-gusset plate weld lengths. Both circular and box section members were considered in the test program. Load-deformation curves were obtained and comparisons were made in terms of strength and ductility. The results obtained from the study were then critically examined and compared with currently available design guidance for slotted gusset plate welded tubular end connections. It is noted that no specific rules exist in international specifications on structural stainless steel which cover the design of such connections. Therefore, the results of this study are compared with the existing design rules for carbon steel.

An Unequal Divider based on Transmission Line with Periodic Capacitor Shunt Connection (캐패시터가 주기적으로 병렬 연결된 전송선로를 이용한 비대칭 분배기)

  • Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.781-786
    • /
    • 2012
  • In this paper, we propose the design and performance of an unequal divider using transmission line with periodic capacitor shunt connection. To design divider with a high dividing ratio, we limit a high impedance line value to fabricate microstrip line and also, design a low impedance line of below $10{\Omega}$ using periodic capacitor shunt connection. As a design example, a 10:1 ratio divider was designed and measured at center frequency 1 GHz to show the validity of the unequal divider using periodic capacitor shunt connection. Its performance is in good agreements with the simulated results.