• 제목/요약/키워드: Design Wind Speed

검색결과 651건 처리시간 0.028초

Vortex-induced reconfiguration of a tandem arrangement of flexible cylinders

  • Lee, Sang Joon;Kim, Jeong Jae;Yeom, Eunseop
    • Wind and Structures
    • /
    • 제21권1호
    • /
    • pp.25-40
    • /
    • 2015
  • Oscillating motions of flexible cylinders are associated to some extent with the aerodynamic response of plants. Tandem motions of reeds with flexible stems in a colony are experimentally investigated using an array of flexible cylinders made of polydimethylsiloxane (PDMS). Consecutive images of flexible cylinders subjected to oncoming wind are recorded with a high-speed camera. To quantify oscillating motions, the average bending angle and displacement of flexible cylinders are evaluated using point-tracking method and spectral analysis. The tandem motions of flexible cylinders are closely related to the flow characteristics around the cylinders. Thus, the dynamic motions of a tandem arrangement of flexible cylinders are investigated with varying numbers of cylinders arranged in-line, numbers of cylinders in a group (behaving like a single body), and Reynolds numbers (Re). When the number of cylinders in a group increases, the damping effect caused by the support of downstream cylinders is pronounced. These results would be provide useful information on the tandem-arranged design of complex structures and energy harvesting devices.

전기충전소의 경제적 운영을 위한 독립발전 시스템 설계 (Independent Generation System Design for the Economic Management of Electrical Charging Stations)

  • 서진규;김규호;이상봉
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.222-227
    • /
    • 2015
  • This paper presents the optimal energy generation systems for economical EVs(Electric Vehicles) charging stations located in an island area. The system includes grid electricity, diesel generator and renewable energy sources of wind turbines and PV(Photovoltaic) panels. The independent generation system is designed with data resources such as annual average wind speed, solar radiation and the grid electricity price by calculating system cost under different structures. This sensitive analysis on the varying data resources allows for the configuration of the most economical generation system for charging stations by comparing initial capital, operating cost, NPC(Net Present Cost) and COE(Cost of Energy). Depending on the increase of the grid cost, the NPC variation of the most economical system which includes renewable energy generations and grid electricity can be smaller than those of other generation systems.

BIPV 시스템의 효율성 향상을 위한 냉각시스템 설계 (Cooling system Design to improve efficiency of BIPV System)

  • 최정식;고재섭;김도연;정병진;최정훈;정동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.323-326
    • /
    • 2008
  • This paper presents a cooling system using thermoelectron for improving the output of BIPV module. The temperature characteristic in regard to improving the output of BIPV system has rarely teen studied up to now but some researchers only presented the method using a ventilator. The cooling system efficiency of BIPV module applied to a ventilator mainly depends on the weather such as wind, insolation etc. Because the cooling system of BIPV module using a ventilator is so sensitive, that is being set off by wind speed at all time but is unable to operate in the NOCT(Nominal Operating Cell Temperature) which is able to make the maximum output. The paper presents the cooling system using thermoelectron so as to solve such problems. The temperature control of thermoelectron can be controlled independently in the outside environment because that is performed by micro-controller. The temperature control of thermoelectron, also, can be operated around NOCT through algorithm of the temperature control. Therefore, outputs of the whole system increase and the efficiency rises. The paper demonstrates the validity of proposed method by comparing the data obtained through a experiment of the cooling method of BIPV using a ventilator and proposed thermoelectron.

  • PDF

경계층 유동의 흡입에 의한 수직충격파 진동저감 (Reduction of Normal Shock-Wave Oscillations by Turbulent Boundary Layer Flow Suction)

  • 김희동
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1229-1237
    • /
    • 1998
  • Experiments of shock-wave/turbulent boundary layer interaction were conducted by using a supersonic wind tunnel. Nominal Mach number was varied in the range of 1.6 to 3.0 by means of different nozzles. The objective of the present study is to investigate the effects of boundary layer suction on normal shock-wave oscillations caused by shock wave/boundary layer interaction in a straight duct. Two-dimensional slits were installed on the top and bottom walls of the duct to bleed turbulent boundary layer flows. The bleed flows were measured by an orifice. The ratio of the bleed mass flow to main mass flow was controlled below the range of 11 per cent. Time-mean and fluctuating wall pressures were measured, and Schlieren optical observations were made to investigate time-mean flow field. Time variations in the shock wave displacement were obtained by a high-speed camera system. The results show that boundary layer suction by slits considerably reduce shock-wave oscillations. For the design Mach number of 2.3, the maximum amplitude of the oscillating shock-wave reduces by about 75% compared with the case of no slit for boundary layer suction.

Experimental Study of the Multi-Row Disk Inlet

  • Maru, Yusuke;Kobayashi, Hiroaki;Kojima, Takoyuki;Sato, Tetsuya;Tanatsugu, Nobuhiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.634-643
    • /
    • 2004
  • In this paper are presented a concept of a new supersonic air inlet, which is designated a Multi-Row Disk (MRD) inlet, aiming at performance improvement under off-design conditions, and results of wind tunnel tests examined performance characteristics of the MRD inlet. The MRD inlet is frequently called ‘a skeleton inlet’ because of its appearance. The performance of a conventional axisymmetric inlet with a solid center body (spike) deteriorates under off-design Mach number conditions. It is due to the fact that total pressure recovery (TPR) governed by the throat area of inlet and mass capture ratio (MCR) governed by an incidence position of an oblique shock from the spike tip into the cowl can not be controlled independently in such air inlet. The MRD inlet has the spike that is composed of a tip cone and several disks arranged downstream of it, based on the experimental fact that several deep cavities on a conical surface have little negative effect on the boundary layer growth. The overall spike length of the MRD inlet is adjustable to the given flight speed by changing space between disks so that a spillage flow can be controlled independently from controlling the throat area. It could be made clear from the result of wind tunnel tests that the MRD inlet improves TPR by 10% compared with a conventional inlet with a solid spike under off-design conditions.

  • PDF

기상현상에 의한 전주 외력의 통계적 분석 (A Statistical Analysis of External Force on Electric Pole due to Meteorological Conditions)

  • 박철영;신창선;조용윤;김영현;박장우
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제6권11호
    • /
    • pp.437-444
    • /
    • 2017
  • 전주(Electric Pole)는 전력 송/배전에 사용되는 지지물로 환경적인 요인의 외력 변화에 민감하다. 전력 설비는 외부 환경변화와 재해로 부터 유지/보수적 관점에서 많은 어려움이 있다. 기상변화는 전주 피해에 주요인으로 작용하며, 경제적으로 미치는 영향이 매우 크다. 가공전선(Aerial Wire)은 온도 영향으로 탄성(Elasticity)변화가 나타나며, 탄성의 변화는 풍속, 풍향 등의 요인에 의해 영향력이 가중된다. 전선에 작용하는 외력은 전주의 피로누적으로 작용된다. 전주의 안전도 평가는 설계 단계에서 이루어지며, 운영중인 전주에 대한 영향도는 고려되지 않는다. 보수/안전성 확보 목적으로 외력의 기상요인 영향도를 분석하는 것은 매우 중요하다. 본 논문에서는 유지/안전성 확보 목적수행을 위해 전주에 설치된 센서노드의 가속도 데이터를 분석하고, 잡음(Noise) 보상 방법으로 칼만필터를 이용했다. 기상 요인별 영향도를 분석하기 위해 고속 푸리에 변환(Fast Fourier Transform)을 수행하고, 주파수 성분별 기상요인 영향도를 분석했다. 영향도 분석 결과 온도, 습도, 일사량, 일조시간, 대기압, 풍향, 풍속의 기상요인 영향이 크게 작용했다. 본 논문에서는 주파수 성분별로 기상요인의 영향도가 다름을 보였으며, 유지보수와 안정성 확보의 목적 달성에 중요한 요소로 작용될 수 있으리라 생각한다.

스테인리스 쿨링포그의 온도저감효과 검증을 위한 모델설계 및 실증 실험 (Model Design and Demonstration Test for the Verification of Temperature Reduction Effect of Cooling Fog System with Stainless Steel)

  • 김재경;강준석;김회진
    • 한국환경과학회지
    • /
    • 제29권6호
    • /
    • pp.683-689
    • /
    • 2020
  • According to a NASA Goddard Institute for Space Studies report, temperatures have risen by approximately 1℃ so far, based on temperatures recorded in 1880. The 2003 heatwave in Europe affected approximately 35,000 people across Europe. In this study, a cooling fog, which is used in smart cities, was designed to efficiently reduce the temperature during a heatwave and its pilot test results were interpreted. A model experiment of the cooling fog was conducted using a chamber, in which nano mist spray instruments and spray nozzles were installed. The designed cooling fog chamber model showed a temperature reduction of up to 13.8℃ for artificial pavement and up to 8.0℃ for green surfaces. However, this model was limited by constant wind speed in the experiment. Moreover, if the cooling fog is used when the wind speed is more than 3m/s in the active green zone, the temperature reduction felt by humans is expected to be even greater. As a second study, the effect of cooling fog on temperature reduction was analyzed by installing a pilot test inside the Land Housing Institute (LHI). The data gathered in this research can be useful for the study of heat reduction techniques in urban areas.

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.

쐐기형 레일클램프에서 초기압착력과 지지대의 적정위치사이의 관계 (Relationship between the Initial Clamping Force and the Proper Position of Supporter in the Wedge Type Rail Clamp)

  • 한동섭;이성욱;한근조;이권순
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 추계학술대회 논문집(제1권)
    • /
    • pp.357-362
    • /
    • 2006
  • 쐐기형 레일클램프는 초기에는 작은 압착력으로 레일을 압착하다가 바람이 불면 쐐기작용에 의해 큰 압착력으로 레일을 압착하는 구조를 가지고 있다. 이 때 쐐기작용을 위해 레일클램프는 레일을 따라 이동하게 되는데, 만약 지지대를 설치하지 않으면 밀림거리가 증가하여 구조물을 파괴에 이르게 하는 과부하가 발생하게 되므로 이를 방지하기 위한 지지대를 적절히 설치하여야 한다. 이러한 지지대의 적정위치는 초기압착력과 쐐기각에 따라서 결정되므로, 본 연구에서는 이러한 초기압착력과 지지대의 적정위치사이의 관계에 대하여 살펴보기 위하여 5가지 쐐기각을 설계변수로 하여 유한요소해석을 수행하였다.

  • PDF

쐐기형 레일클램프에서 초기압착력과 지지대의 위치사이의 관계 (Relationship between the Initial Clamping Force and the Position of Supporter in the Wedge Type Rail Clamp)

  • 이성욱;한근조;이권순;한동섭
    • 한국항해항만학회지
    • /
    • 제31권1호
    • /
    • pp.65-70
    • /
    • 2007
  • 쐐기형 레일클램프는 초기에는 작은 압착력으로 레일을 압착하다가 바람이 불면 쐐기작용에 의해 큰 압착력으로 레일을 압착하는 구조를 가지고 있다. 이 때쐐기작용을 위해 레일클램프는 레일을 따라 이동하게 되는데, 만약 지지대를 설치하지 않으면 밀림거리가 증가하여 구조물을 파괴에 이르게 하는 과부하가 발생하게 되므로 이를 방지하기 위한 지지대를 적절히 설치하여야 한다. 이러한 지지대의 적정위치는 초기압착력과 쐐기각에 따라서 결정되므로, 본 연구에서는 이러한 초기압착력과 지지대의 위치사이의 관계에 대하여 살펴보기 위하여 5가지 쐐기각을 설계변수로 하여 유한요소해석을 수행하였다.